Padmavathy Bakthavathsalam
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Padmavathy Bakthavathsalam has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
- J. Justin Gooding
University of New South Wales
6 shared publications - Vinoth Kumar Rajendran
Department of Molecular Sciences, Macquarie University, Sydney, Australia
4 shared publications - Anwar Sunna
Australian Research Council Industrial Transformation Training Centre for Facilitated Advancement of Australia’s Bioactives (FAAB), Sydney, Australia
2 shared publications - Baquir Mohammed Jaffar Ali
Department of Green Energy Technology, Pondicherry University, Kalapet, Puducherry-605014, India
2 shared publications Peter L. Bergquist
2 shared publications- Richard David Tilley
School of Chemistry, University of New South Wales, Sydney, NSW 2052, Australia
2 shared publications
Latest Publications
- 1 December 2020
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 169, 112612
Single particle detection of protein molecules using dark-field microscopy to avoid signals from nonspecific adsorption
- 1 December 2020
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 169, 112612
Single particle detection of protein molecules using dark-field microscopy to avoid signals from nonspecific adsorption
- 17 December 2019
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 12 (3) , 1680-1687
Optical tweezers-based characterisation of gold core–satellite plasmonic nano-assemblies incorporating thermo-responsive polymers
We report on the characterisation of the optical properties and dynamic behaviour of optically trapped single stimuli-responsive plasmonic nanoscale assemblies. Nano-assemblies consist of a core–satellite arrangement where the constituent nanoparticles are connected by the thermoresponsive polymer, poly(DEGA-co-OEGA). The optical tweezers allow the particles to be held isolated in solution and interrogated using dark-field spectroscopy. Additionally, controlling the optical trapping power provides localised heating for probing the thermal response of the nanostructures. Our results identify a number of distinct core–satellite configurations that can be stably trapped, which are verified using finite element modelling. Laser heating of the nanostructures through the trapping laser yields irreversible modification of the arrangement, as observed through the scattering spectrum. We consider which factors may be responsible for the observed behaviour in the context of the core–satellite geometry, polymer–solvent interaction, and the bonding of the nanoparticles.
- 17 December 2019
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 12 (3) , 1680-1687
Optical tweezers-based characterisation of gold core–satellite plasmonic nano-assemblies incorporating thermo-responsive polymers
We report on the characterisation of the optical properties and dynamic behaviour of optically trapped single stimuli-responsive plasmonic nanoscale assemblies. Nano-assemblies consist of a core–satellite arrangement where the constituent nanoparticles are connected by the thermoresponsive polymer, poly(DEGA-co-OEGA). The optical tweezers allow the particles to be held isolated in solution and interrogated using dark-field spectroscopy. Additionally, controlling the optical trapping power provides localised heating for probing the thermal response of the nanostructures. Our results identify a number of distinct core–satellite configurations that can be stably trapped, which are verified using finite element modelling. Laser heating of the nanostructures through the trapping laser yields irreversible modification of the arrangement, as observed through the scattering spectrum. We consider which factors may be responsible for the observed behaviour in the context of the core–satellite geometry, polymer–solvent interaction, and the bonding of the nanoparticles.
- 1 November 2019
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 298
Smartphone detection of antibiotic resistance using convective PCR and a lateral flow assay
- 1 November 2019
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 298
Smartphone detection of antibiotic resistance using convective PCR and a lateral flow assay
- 18 September 2019
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 144 (21) , 6225-6230
The use of a personal glucose meter for detecting procalcitonin through glucose encapsulated within liposomes
A glucose meter-based immunosensing platform that allows the quantification of procalcitonin in whole blood samples at clinically-relevant concentrations.
- 18 September 2019
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 144 (21) , 6225-6230
The use of a personal glucose meter for detecting procalcitonin through glucose encapsulated within liposomes
A glucose meter-based immunosensing platform that allows the quantification of procalcitonin in whole blood samples at clinically-relevant concentrations.
- 1 June 2019
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 134, 68-75
A portable nucleic acid detection system using natural convection combined with a smartphone
- 1 June 2019
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 134, 68-75
A portable nucleic acid detection system using natural convection combined with a smartphone
- 5 September 2018
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 34 (49) , 14817-14824
DNA-Hybridization Detection on Si(100) Surfaces Using Light-Activated Electrochemistry: A Comparative Study between Bovine Serum Albumin and Hexaethylene Glycol as Antifouling Layers
Light can be used to spatially resolve electrochemical measurements on a semiconductor electrode. This phenomenon has been explored to detect DNA hybridization with light-addressable potentiometric sensors and, more recently, with light-addressable amperometric sensors based on organic-monolayer-protected Si(100). Here, a contribution to the field is presented by comparing sensing performances when bovine serum albumin (BSA) and hexaethylene glycol (OEG6) are employed as antifouling layers that resist nonspecific adsorption to the DNA-modified interface on Si(100) devices. What is observed is that both sensors based on BSA or OEG6 initially allow electrochemical distinction among complementary, noncomplementary, and mismatched DNA targets. However, only surfaces based on OEG6 can sustain electroactivity over time. Our results suggest that this relates to accelerated SiOx formation occasioned by BSA proteins adsorbing on monolayer-protected Si(100) surfaces. Therefore, DNA biosensors were analytically explored on low-doped Si(100) electrodes modified on the molecular level with OEG6 as an antifouling layer. First, light-activated electrochemical responses were recorded over a range of complementary DNA target concentrations. A linear semilog relation was obtained from 1.0 × 10–11 to 1.0 × 10–6 mol L–1 with a correlation coefficient of 0.942. Then, measurements with three independent surfaces indicated a relative standard deviation of 4.5%. Finally, selectivity tests were successfully performed in complex samples consisting of a cocktail mixture of four different DNA sequences. Together, these results indicate that reliable and stable light-activated amperometric DNA sensors can be achieved on Si(100) by employing OEG6 as an antifouling layer.
- 5 September 2018
- Published by American Chemical Society (ACS) in Langmuir
- Vol. 34 (49) , 14817-14824
DNA-Hybridization Detection on Si(100) Surfaces Using Light-Activated Electrochemistry: A Comparative Study between Bovine Serum Albumin and Hexaethylene Glycol as Antifouling Layers
Light can be used to spatially resolve electrochemical measurements on a semiconductor electrode. This phenomenon has been explored to detect DNA hybridization with light-addressable potentiometric sensors and, more recently, with light-addressable amperometric sensors based on organic-monolayer-protected Si(100). Here, a contribution to the field is presented by comparing sensing performances when bovine serum albumin (BSA) and hexaethylene glycol (OEG6) are employed as antifouling layers that resist nonspecific adsorption to the DNA-modified interface on Si(100) devices. What is observed is that both sensors based on BSA or OEG6 initially allow electrochemical distinction among complementary, noncomplementary, and mismatched DNA targets. However, only surfaces based on OEG6 can sustain electroactivity over time. Our results suggest that this relates to accelerated SiOx formation occasioned by BSA proteins adsorbing on monolayer-protected Si(100) surfaces. Therefore, DNA biosensors were analytically explored on low-doped Si(100) electrodes modified on the molecular level with OEG6 as an antifouling layer. First, light-activated electrochemical responses were recorded over a range of complementary DNA target concentrations. A linear semilog relation was obtained from 1.0 × 10–11 to 1.0 × 10–6 mol L–1 with a correlation coefficient of 0.942. Then, measurements with three independent surfaces indicated a relative standard deviation of 4.5%. Finally, selectivity tests were successfully performed in complex samples consisting of a cocktail mixture of four different DNA sequences. Together, these results indicate that reliable and stable light-activated amperometric DNA sensors can be achieved on Si(100) by employing OEG6 as an antifouling layer.
- 1 September 2018
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 268, 255-263
Locked nucleic acid molecular beacon for multiplex detection of loop mediated isothermal amplification
- 1 September 2018
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 268, 255-263
Locked nucleic acid molecular beacon for multiplex detection of loop mediated isothermal amplification
- 13 August 2018
- Published by Wiley in Reviews in Medical Virology
- Vol. 28 (5) , e1995
Systematic review of the impact of point‐of‐care testing for influenza on the outcomes of patients with acute respiratory tract infection
Summary: Acute respiratory tract infections are a major cause of morbidity and mortality and represent a significant burden on the health care system. Laboratory testing is required to definitively distinguish infecting influenza virus from other pathogens, resulting in prolonged emergency department (ED) visits and unnecessary antibiotic use. Recently available rapid point‐of‐care tests (POCT) may allow for appropriate use of antiviral and antibiotic treatments and decrease patient lengths of stay.We undertook a systematic review to assess the effect of POCT for influenza on three outcomes: (1) antiviral prescription, (2) antibiotic prescription, and (3) patient length of stay in the ED.The databases Medline and Embase were searched using MeSH terms and keywords for influenza, POCT, antivirals, antibiotics, and length of stay.Amongst 245 studies screened, 30 were included. The majority of papers reporting on antiviral prescription found that a positive POCT result significantly increased use of antivirals for influenza compared with negative POCT results and standard supportive care. A positive POCT result also led to decreased antibiotic use. The results of studies assessing the effect of POCT on ED length of stay were not definitive.The studies assessed in this systematic review support the use of POCT for diagnosis of influenza in patients suffering an acute respiratory infection. Diagnosis using POCT may lead to more appropriate prescription of treatments for infectious agents. Further studies are needed to assess the effect of POCT on the length of stay in ED.
- 13 August 2018
- Published by Wiley in Reviews in Medical Virology
- Vol. 28 (5) , e1995
Systematic review of the impact of point‐of‐care testing for influenza on the outcomes of patients with acute respiratory tract infection
Summary: Acute respiratory tract infections are a major cause of morbidity and mortality and represent a significant burden on the health care system. Laboratory testing is required to definitively distinguish infecting influenza virus from other pathogens, resulting in prolonged emergency department (ED) visits and unnecessary antibiotic use. Recently available rapid point‐of‐care tests (POCT) may allow for appropriate use of antiviral and antibiotic treatments and decrease patient lengths of stay.We undertook a systematic review to assess the effect of POCT for influenza on three outcomes: (1) antiviral prescription, (2) antibiotic prescription, and (3) patient length of stay in the ED.The databases Medline and Embase were searched using MeSH terms and keywords for influenza, POCT, antivirals, antibiotics, and length of stay.Amongst 245 studies screened, 30 were included. The majority of papers reporting on antiviral prescription found that a positive POCT result significantly increased use of antivirals for influenza compared with negative POCT results and standard supportive care. A positive POCT result also led to decreased antibiotic use. The results of studies assessing the effect of POCT on ED length of stay were not definitive.The studies assessed in this systematic review support the use of POCT for diagnosis of influenza in patients suffering an acute respiratory infection. Diagnosis using POCT may lead to more appropriate prescription of treatments for infectious agents. Further studies are needed to assess the effect of POCT on the length of stay in ED.
- 3 April 2014
- Published by Springer Nature in Microchimica Acta
- Vol. 181 (15-16) , 1815-1821
Smartphone based bacterial detection using biofunctionalized fluorescent nanoparticles
- 3 April 2014
- Published by Springer Nature in Microchimica Acta
- Vol. 181 (15-16) , 1815-1821
Smartphone based bacterial detection using biofunctionalized fluorescent nanoparticles
- 23 July 2013
- Published by Springer Nature in Microchimica Acta
- Vol. 180 (13-14) , 1241-1248
Immunomagnetic nanoparticle based quantitative PCR for rapid detection of Salmonella
- 23 July 2013
- Published by Springer Nature in Microchimica Acta
- Vol. 180 (13-14) , 1241-1248
Immunomagnetic nanoparticle based quantitative PCR for rapid detection of Salmonella