AAAbdulhadi Alhelwani

Abdulhadi Alhelwani

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Abdulhadi Alhelwani has a total of 4 co-authors. Here are the top co-authors by number of shared publications:

  • Constantinus Politis

    OMFS IMPATH Research Group, Department of Imaging & Pathology, Faculty of Medicine, KU Leuven & Oral and Maxillofacial Surgery, University Hospitals Leuven, Leuven, Belgium

    1 shared publication
  • Elke Van De Casteele

    OMFS IMPATH Research Group, Department of Imaging & Pathology, Faculty of Medicine, KU Leuven & Oral and Maxillofacial Surgery, University Hospitals Leuven, Leuven, Belgium

    1 shared publication
  • Eman Shaheen

    Katholieke Univ Leuven, Fac Med, Dept Imaging & Pathol, OMFS IMPATH Res Grp, Leuven, Belgium

    1 shared publication
  • Reinhilde Jacobs

    OMFS-IMPATH Research Group, Department of Imaging and Pathology, Catholic University Leuven, Leuven, Belgium

    1 shared publication

Latest Publications

  • Open Access

    Evaluation of Dimensional Changes of 3D Printed Models After Sterilization: A Pilot Study

    by Eman Shaheen, Abdulhadi Alhelwani, Elke Van De Casteele, Constantinus Politis, Reinhilde Jacobs

    Objectives: To assess the effect of two of the most commonly used sterilization techniques on 3D printed clinical objects. Materials & Methods: The two sterilization methods used in our hospital and investigated in this paper are: Steam heat and Gas plasma. Three objects were printed and tested in this study: a tooth replica, an orthognathic final splint, a surgical cutting guide for the purpose of mandible reconstruction. For each of the 3 objects, 4 copies were made: one original STL object, one copy of the object pre-sterilization, one copy of post-steam heat sterilization, and one copy of post-gas plasma sterilization. Each printed object was scanned using a high resolution CBCT protocol and the compared (morphologically and volumetrically). Results: At the level of volumetric changes, no difference was found between pre and post-sterilization for both methods evaluated. As for the morphological changes, only differences were noticed with the orthognathic splint object indicating deformation of the printed splints after sterilization. Larger differences were observed with heat sterilization, making it less reliable. Conclusion: Sterilization of dental objects to be used in a clinical setting may lead to deformation of the printed model, especially for heat sterilization. Further investigations are needed to confirm these findings.