Jeffrey B. Fortin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jeffrey B. Fortin has a total of 86 co-authors. Here are the top co-authors by number of shared publications:
T.-M. Lu
Center for Integrated Electronics and Electronics Manufacturing, Rensselaer Polytechnic Institute, Troy, New York 12180
6 shared publicationsK. Subramanian
3 shared publicationsA. Kumar
Department of Physics, State University of New York at Albany, Albany, NY 12222, USA
2 shared publications- Alberto Albinati
Department of Chemistry, University of Milan, via C. Golgi 19, Milan 20133, Italy
2 shared publications B. Wang
Rensselaer Polytechnic Institute
2 shared publicationsC. Jin
Texas Instrument, Dallas, TX 75265, USA
2 shared publications
Latest Publications
- 5 June 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 6 (3) , 618-622
Scalable vertical diaphragm pressure sensors: device and process Design, Design for packaging
We present a design, process How, and packaging scheme for a novel three-dimensional capacitive microelectromechanical systems pressure sensor [1], [10]. These sensors present a paradigm shift in pressure sensor technology. They contain an array of vertical diaphragms perpendicular to the wafer plane where each pair of diaphragms requires orders of magnitude lower footprint than traditional in-plane sensors. The sensor can be arrayed or scaled up for increased sensitivity and can be absolute, gauge or differential. Fabrication requires 2-4 masks, depending on process How and has been greatly simplified, without reduction in performance, for high yield and low cost. Multiple geometries have been modeled with sensitivities reaching several fF/kPa and temperature coefficient of sensitivity better than conventional devices. Pressure and electrical ports are individually interchangeable between front and back sides. This allows for a simple design that has only Si facing the sensing environment and the electrical connections on the backside, thus enabling simple packaging for both pressure and electrical ports.
- 5 June 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 6 (3) , 618-622
Scalable vertical diaphragm pressure sensors: device and process Design, Design for packaging
We present a design, process How, and packaging scheme for a novel three-dimensional capacitive microelectromechanical systems pressure sensor [1], [10]. These sensors present a paradigm shift in pressure sensor technology. They contain an array of vertical diaphragms perpendicular to the wafer plane where each pair of diaphragms requires orders of magnitude lower footprint than traditional in-plane sensors. The sensor can be arrayed or scaled up for increased sensitivity and can be absolute, gauge or differential. Fabrication requires 2-4 masks, depending on process How and has been greatly simplified, without reduction in performance, for high yield and low cost. Multiple geometries have been modeled with sensitivities reaching several fF/kPa and temperature coefficient of sensitivity better than conventional devices. Pressure and electrical ports are individually interchangeable between front and back sides. This allows for a simple design that has only Si facing the sensing environment and the electrical connections on the backside, thus enabling simple packaging for both pressure and electrical ports.
- 1 January 2006
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 119 (1) , 394-405
A hydromechanical biomimetic cochlea: Experiments and models
The construction, measurement, and modeling of an artificial cochlea (ACochlea) are presented in this paper. An artificial basilar membrane (ABM) was made by depositing discrete Cu beams on a piezomembrane substrate. Rather than two fluid channels, as in the mammalian cochlea, a single fluid channel was implemented on one side of the ABM, facilitating the use of a laser to detect the ABM vibration on the other side. Measurements were performed on both the ABM and the ACochlea. The measurement results on the ABM show that the longitudinal coupling on the ABM is very strong. Reduced longitudinal coupling was achieved by cutting the membrane between adjacent beams using a laser. The measured results from the ACochlea with a laser-cut ABM demonstrate cochlear-like features, including traveling waves, sharp high-frequency rolloffs, and place-specific frequency selectivity. Companion computational models of the mechanical devices were formulated and implemented using a circuit simulator. Experimental data were compared with simulation results. The simulation results from the computational models of the ABM and the ACochlea are similar to their experimental counterparts.
- 1 January 2006
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 119 (1) , 394-405
A hydromechanical biomimetic cochlea: Experiments and models
The construction, measurement, and modeling of an artificial cochlea (ACochlea) are presented in this paper. An artificial basilar membrane (ABM) was made by depositing discrete Cu beams on a piezomembrane substrate. Rather than two fluid channels, as in the mammalian cochlea, a single fluid channel was implemented on one side of the ABM, facilitating the use of a laser to detect the ABM vibration on the other side. Measurements were performed on both the ABM and the ACochlea. The measurement results on the ABM show that the longitudinal coupling on the ABM is very strong. Reduced longitudinal coupling was achieved by cutting the membrane between adjacent beams using a laser. The measured results from the ACochlea with a laser-cut ABM demonstrate cochlear-like features, including traveling waves, sharp high-frequency rolloffs, and place-specific frequency selectivity. Companion computational models of the mechanical devices were formulated and implemented using a circuit simulator. Experimental data were compared with simulation results. The simulation results from the computational models of the ABM and the ACochlea are similar to their experimental counterparts.
- 1 September 2003
- Published by Springer Nature in Journal of Electronic Materials
- Vol. 32 (9) , 925-931
Stability of fluorinated parylenes to oxygen reactive-ion etching under aluminum, aluminum oxide, and tantalum nitride overlayers
- 1 September 2003
- Published by Springer Nature in Journal of Electronic Materials
- Vol. 32 (9) , 925-931
Stability of fluorinated parylenes to oxygen reactive-ion etching under aluminum, aluminum oxide, and tantalum nitride overlayers
- 1 January 2003
- Published by ASME International
- p. 183-192
MEMS Microvalve for Harsh Environment
There is a need for small valves which control flow at high temperature and pressure for a number of commercial and military applications. However, traditional solenoid actuated valves are typically expensive, heavy and subject to undesirable electrical and mechanical failure modes. Micromachining techniques, commonly used in the electronics industry, are finding more and more applications for Micro Electro Mechanical Systems (MEMS). Most of the previous work in the area of MEMS valves has been limited to low pressure/low temperature flows at ambient conditions. In this presentation, the development and testing of a two stage MEMS diaphragm valve that is capable of operating at high temperature and pressure gas flows is presented. Valve requirements, tolerances and thermal management are considered in the design. Valve fabrication processes, such as Reactive Ion Etching (RIE) and laser ablation, are discussed in detail. Issues related to the actuation of the microvalve are also discussed, including two approaches based on shape memory alloy and piezoelectric materials. Modeling and test results are presented throughout to identify successes and lessons learned.
- 1 January 2003
- Published by ASME International
- p. 183-192
MEMS Microvalve for Harsh Environment
There is a need for small valves which control flow at high temperature and pressure for a number of commercial and military applications. However, traditional solenoid actuated valves are typically expensive, heavy and subject to undesirable electrical and mechanical failure modes. Micromachining techniques, commonly used in the electronics industry, are finding more and more applications for Micro Electro Mechanical Systems (MEMS). Most of the previous work in the area of MEMS valves has been limited to low pressure/low temperature flows at ambient conditions. In this presentation, the development and testing of a two stage MEMS diaphragm valve that is capable of operating at high temperature and pressure gas flows is presented. Valve requirements, tolerances and thermal management are considered in the design. Valve fabrication processes, such as Reactive Ion Etching (RIE) and laser ablation, are discussed in detail. Issues related to the actuation of the microvalve are also discussed, including two approaches based on shape memory alloy and piezoelectric materials. Modeling and test results are presented throughout to identify successes and lessons learned.
- 30 April 2002
- Published by American Chemical Society (ACS) in Chemistry of Materials
- Vol. 14 (5) , 1945-1949
A Model for the Chemical Vapor Deposition of Poly(para-xylylene) (Parylene) Thin Films
- 30 April 2002
- Published by American Chemical Society (ACS) in Chemistry of Materials
- Vol. 14 (5) , 1945-1949
A Model for the Chemical Vapor Deposition of Poly(para-xylylene) (Parylene) Thin Films
- 1 October 2001
- Published by Elsevier in Thin Solid Films
- Vol. 397 (1-2) , 223-228
Ultraviolet radiation induced degradation of poly-para-xylylene (parylene) thin films
- 1 October 2001
- Published by Elsevier in Thin Solid Films
- Vol. 397 (1-2) , 223-228
Ultraviolet radiation induced degradation of poly-para-xylylene (parylene) thin films
- 1 September 2001
- Published by Elsevier in Thin Solid Films
- Vol. 396 (1-2) , 5-8
Thermal stability of xerogel films
- 1 September 2001
- Published by Elsevier in Thin Solid Films
- Vol. 396 (1-2) , 5-8
Thermal stability of xerogel films
- 1 January 2001
- Published by Springer Nature
- p. 232-234
Dielectric Property Measurement of Sub-micron Thin Film by Differential Time-domain Spectroscopy
- 1 January 2001
- Published by Springer Nature
- p. 232-234
Dielectric Property Measurement of Sub-micron Thin Film by Differential Time-domain Spectroscopy