Tonian Robinson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tonian Robinson has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
Andreas Weller
Institut für Geophysik Technische Universität Clausthal Clausthal‐Zellerfeld Germany
1 shared publicationBeth Parker
G360 Institute for Groundwater Research, College of Engineering and Physical Sciences University of Guelph ON Canada
1 shared publication- Carla Rose
G360 Institute for Groundwater Research, College of Engineering and Physical Sciences University of Guelph ON Canada
1 shared publication - Judith Robinson
Pacific Northwest National Laboratory, Richland, USA
1 shared publication - Kristina Keating
Rutgers University Newark Newark NJ USA
1 shared publication - Lee Slater
Department of Earth and Environmental Sciences Rutgers University Newark Newark New Jersey USA
1 shared publication
Latest Publications
- Open Access
- 16 May 2018
- Published by American Geophysical Union (AGU) in Water Resources Research
- Vol. 54 (5) , 3436-3452
On Permeability Prediction From Complex Conductivity Measurements Using Polarization Magnitude and Relaxation Time
Geophysical length scales determined from complex conductivity (CC) measurements can be used to estimate permeability when the electrical formation factor F is known. Two geophysical length scales have been proposed: (1) the specific polarizability normalized by the imaginary conductivity and (2) the time constant multiplied by a diffusion coefficient . The parameters and account for the control of fluid chemistry and/or varying minerology on the geophysical length scale. We evaluated the predictive capability of two CC permeability models: (1) an empirical formulation based on or normalized chargeability and (2) a mechanistic formulation based on . The performance of the CC models was evaluated against measured ; and further compared against that of well‐established estimation equations that use geometric length scales. Both CC models predict permeability within one order of magnitude for a database of 58 sandstone samples, with the exception of samples characterized by high pore volume normalized surface area . Variations in and likely contribute to the poor model performance for the high samples, which contain significant dolomite. Two observations favor the implementation of the ‐based model over the ‐based model for field‐scale estimation: (1) a limited range of variation in relative to and (2) field measurements are less time consuming to acquire relative to . The need for a reliable field‐estimate of limits application of either model, in particular the model due to a high power law exponent associated with .
- 16 May 2018
- Published by American Geophysical Union (AGU) in Water Resources Research
- Vol. 54 (5) , 3436-3452
Open AccessOn Permeability Prediction From Complex Conductivity Measurements Using Polarization Magnitude and Relaxation Time
Geophysical length scales determined from complex conductivity (CC) measurements can be used to estimate permeability when the electrical formation factor F is known. Two geophysical length scales have been proposed: (1) the specific polarizability normalized by the imaginary conductivity and (2) the time constant multiplied by a diffusion coefficient . The parameters and account for the control of fluid chemistry and/or varying minerology on the geophysical length scale. We evaluated the predictive capability of two CC permeability models: (1) an empirical formulation based on or normalized chargeability and (2) a mechanistic formulation based on . The performance of the CC models was evaluated against measured ; and further compared against that of well‐established estimation equations that use geometric length scales. Both CC models predict permeability within one order of magnitude for a database of 58 sandstone samples, with the exception of samples characterized by high pore volume normalized surface area . Variations in and likely contribute to the poor model performance for the high samples, which contain significant dolomite. Two observations favor the implementation of the ‐based model over the ‐based model for field‐scale estimation: (1) a limited range of variation in relative to and (2) field measurements are less time consuming to acquire relative to . The need for a reliable field‐estimate of limits application of either model, in particular the model due to a high power law exponent associated with .