KJKai Jin

Kai Jin

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Kai Jin has a total of 47 co-authors. Here are the top co-authors by number of shared publications:

  • Hanbin Ma

    University of Electronic Science and Technology of China

    6 shared publications
  • Siyi Hu

    Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences

    3 shared publications
  • Jinhua Li

    Nanophotonics and Biophotonics Key Laboratory of Jilin Province, School of Physics, Changchun University of Science and Technology 1 , Changchun, Jilin 130022

    2 shared publications
  • Siyi Hu

    Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China

    2 shared publications
  • Anqi Ding

    Department of Analytical Chemistry & Division of Antitumor Pharmacology, State Key Laboratory of Drug Research, Shanghai Institute of Materia Medica, Chinese Academy of Sciences, Shanghai 201203, China

    1 shared publication
  • Arokia Nathan

    School of Information Science and Engineering, Shandong University, Qingdao, China

    1 shared publication

Latest Publications

  • Tailing-Actuated Interfacial Liquid Mixing (TAIL-Mix) Enables Efficient Nucleic Acid Extraction and Integrated HPV Genotyping on a Digital Microfluidics Platform

    by Jiajian Ji, Xinpei Pang, Jinxin Fu, Maolin Zhang, Kai Jin, Hanbin Ma, Ruhong Yan, Siyi Hu, Qian Mei

    High-risk human papillomavirus (HPV) genotyping is essential for risk-stratified cervical cancer screening. However, current laboratory workflows remain multistep, instrument-intensive, and difficult to scale up for high-throughput multiplex testing. Here we present an active-matrix digital microfluidic (AM-DMF) platform for high-throughput HPV genotyping, utilizing a tailing-actuated interfacial liquid mixing (TAIL-Mix) strategy to enable highly efficient nucleic acid extraction and robust downstream amplification. The AM-DMF chip features a 921,600-electrode array that uses programmable, time-sequenced electrode actuation to stretch and retract droplets. This mechanism generates TAIL-Mix, significantly enhancing mixing efficiency under low-Reynolds-number conditions. Through combined COMSOL simulations and OpenCV-based image analysis, we determined that optimal TAIL-Mix parameters (a tailing distance of 7–8 pixels; 1.5 steps s–1) achieve a homogeneous state (mixing index ≥ 0.9) within 2 s, superior to traditional schemes. This enhanced mixing proved to be critical for high-performance processing, enabling magnetic-bead DNA extraction with 75% DNA recovery while reducing the protocol time to 26 min and the sample input to 1.5 μL of sample (100-fold reduction compared with conventional protocols). By integrating TAIL-Mix-enhanced extraction, thermal cycling, and 21-plex end point fluorescence readout on a single chip, the platform successfully performs parallel 21-genotype PCR analysis for two samples. In a clinical cohort of 20 cervical samples, the AM-DMF assay shows 100% sensitivity and 100% specificity relative to qPCR. Ultimately, this TAIL-Mix-empowered AM-DMF system offers a robust solution for low-reagent consumption, high-throughput clinical diagnostics.

  • Open Access

    AM-DMF-SCP-pro: An Ultrafast and Streamlined Nanolitre-Scale Lab-on-a-Chip Platform for Single-Cell Proteomics and Tumor Microenvironment Profiling

    by Kai Jin, Zhicheng Yang, Anqi Ding, Rong Wang, Yifan Ma, Yuqiu Wang, Minchu Tang, Yong Wu, Qian Liu, Jiajian Ji, et al.

    Single-cell proteomics (SCP) remains constrained by slow sample preparation and background interference in low-input, multistep workflows, limiting its broader practical use in complex biological samples. Here we report AM-DMF-SCP-pro, a streamlined active-matrix digital microfluidic workflow that enables rapid on-chip lysis and digestion in 6 nL droplets within a closed nanolitre-confined microenvironment. AM-DMF-SCP-pro reduces total sample-preparation time to as little as 30 min, including a 15 min digestion step, while maintaining quantitative reproducibility and digestion performance. Systematic optimization of mass spectrometry acquisition and nanolitre-scale digestion conditions enables deeper, more sensitive and lower-background proteome profiling from ultra-low peptide inputs. In murine tumor samples, AM-DMF-SCP-pro reliably resolves immune and tumor compartments, identifies treatment-associated tumor cell states and enables quantitative analysis of neutrophil-associated proteomic signatures. These results establish AM-DMF-SCP-pro as a practical workflow for rapid, low-background single-cell proteome profiling in complex biological samples.


  • Open Access

    A universal model for continuous “one-to-two” high-efficient droplet generation in digital microfluidics

    by Chenxuan Hu, Kai Jin, Hanbin Ma

    High-efficient droplet generation is crucial in microfluidics platforms in bio-applications. Among the microfluidic techniques, digital microfluidics, although with the capability of programmatically manipulating the droplets, is less effective in high-throughput droplets generation. In this Letter, a continuous “one-to-two” droplet generation strategy on digital microfluidics platform is achieved with an exponential generation efficiency, while overcoming the restriction on the droplet geometries (aspect ratio) in a wide range. An energy-based sub-droplet generation model is also proposed, as an expansion to the previous Laplace pressure-based geometrical model. The electrical parameters are taken into computing the sub-droplet generation on digital microfluidics from the aspect of energy. The proposed continuous “one-to-two” droplet generation strategy can generate sub-droplets with a minimized electrodes' number while with a higher energy input in each operation. The exponential efficiency will open the era for high-throughput droplets' application developments in digital microfluidics.


  • “One-to-three” droplet generation in digital microfluidics for parallel chemiluminescence immunoassays

    by Kai Jin, Chenxuan Hu, Siyi Hu, Chengyou Hu, Jinhua Li, Hanbin Ma

    In digital microfluidics, droplet generation is a fundamental operation for quantitative liquid manipulation. The generation of well-defined micro-droplets on a chip with restricted device geometries has become a real obstacle for digital microfluidics platforms to be used in parallel for in vitro diagnostic applications. Here, we propose a “one-to-three” droplet splitting technique that is able to generate sub-microlitre droplets beyond the “well-known” geometry limit in electrowetting-on-dielectric digital microfluidics. Accordingly, we realized an on-chip magnetic bead chemiluminescence immunoassay for parallel detection with the “one-to-three” technique. With the help of the generated micro droplets, we were able to retain the magnetic beads by a significantly reduced magnetic force. We have shown the detection of five B-type natriuretic peptide analyte samples on a single chip for around 10 minutes. The correlation coefficient of the calibration curve was 0.9942, and the detection limit was lower than 5 pg mL−1.


  • Large-area manufacturable active matrix digital microfluidics platform for high-throughput biosample handling

    by H. Ma, S. Shi, K. Jin, D. Wang, S. Hu, Y. Su, Y. Zhang, J. Li, Z. Liu, C. Jiang, et al.

    We present an active-matrix digital microfluidics platform for bio-sample handling, which demonstrates extension of the ubiquitous and highly-scalable flat-panel technology from displays to bio-applications, and leverage the well-established a-Si thin-film transistor (TFT) manufacturing facilities and excess capacity. The fabricated chip contains 32 × 32 pixels in an active area of 10 cm 2 , which can be individually or simultaneously addressed. Generation and manipulation of liquid droplets at single pixel level with the volume coefficient of variation around 1% is demonstrated. Such performance is substantial improvement over current state-of-the-art (9-pixel resolution and 4% variation). This work opens new possibilities for on-chip in vitro diagnostics in point-of-care testing.


  • A Zero-Dimensional Velocity-Composition-Frequency Probability Density Function Model for Compression-Ignition Engine Simulation

    by Chandan Paul, Kai Jin, Navin Fogla, Kevin Roggendorf, Syed Wahiduzzaman

    Numerical simulation of in-cylinder processes can significantly reduce the development and refinement costs of engines. While it can be argued that higher fidelity models improve accuracy of prediction, it comes at the expense of high computational cost. In this respect, a 3D analysis of in-cylinder processes may not be feasible for evaluating large number of design and operating conditions. The situation can be more foreboding for transient simulations. In the current work a phenomenological combustion modeling approach is explored that can be implemented in a lower fidelity modeling framework and can approach the accuracy of higher dimensional models with significant reduction in computational cost. The proposed model uses transported probability density function (tPDF) method within a 0D framework to provide a computationally efficient solution while capturing the essential physics of in-cylinder combustion. Scalar mixing is accounted for by a modified Euclidean Minimum Spanning Tree (EMST) mixing model. A new model has been formulated to calculate the mixing timescale using the velocity-composition-frequency (VCF) tPDF method. Numerical comparisons have been performed for two engines: one with a 3D-CFD simulated diesel engine to compare the in-cylinder composition and thermal stratification, and one with a diesel engine where measured data is available over a range of operating conditions encompassing a range of speed, load, and exhaust-gas recirculation (EGR). A 42-species chemical mechanism including thermal NO is used to represent the gas-phase chemistry. The proposed 0D-VCF model predicted pressure, heat-release-rate, equivalence-ratio vs temperature distribution, and NOx are compared to the 3D-CFD data, as well as to the experimentally measured data. The proposed model was able to capture the 3D-CFD trend of equivalence-ratio vs temperature distribution at different crank-angle degrees quite accurately. The 0D-VCF model computed pressure and heat-release-rate along with the NOx showed reasonable agreement with the experiment. In summary, the proposed 0D numerical model has the potential to provide a computationally less expensive alternative to a 3D numerical simulation for estimating engine performance and engine-out emission quantities when transient or large number of operating points are to be simulated.


  • Disposable impedance-based immunosensor array with direct-laser writing platform

    by Kai Jin, Siyi Hu, Yang Su, Chao Yang, Jinhua Li, Hanbin Ma


  • Numerical Simulation of a Gas Bubble Rising in Power-Law Fluids Using a Sharp Surface Force Implementation

    by Purushotam Kumar, Kai Jin, Surya Pratap Vanka

    In this paper, we have applied a recently-developed numerical technique to study the three-dimensional dynamics of a confined air bubble rising in shear thinning and shear-thickening power-law fluids. The method is a blend of Volume of Fluid and Level Set methods and incorporates a Sharp Surface Force Method (SSF) for surface tension forces by solving a second Pressure Poisson Equation (PPE). The gas-liquid interface is captured by an equation for the liquid volume fraction and advected using the geometry reconstruction method. The interface normal and curvature are computed using level-set and height function methods. The accurate representation of the interface and interfacial forces significantly suppressed the spurious velocities commonly observed with conventional volume of fluid method and the Continuum Surface Force (CSF). The algorithm is implemented in a in-house code called CUFLOW and runs on multiple GPUs platform. We explored the effects of fluid rheology, Bond number, and wall confinement on bubble’s transient shape, rise velocity, rise path, and generated vortex structures. The power-law index is varied from 0.25 to 1.50 covering shear-thinning and shear-thickening regimes. Three Bond numbers (Bo = 2, 10 and 50) and three confinement ratios (Cr = 4, 6 and 8) are considered, and their impacts on bubble’s dynamics are analyzed. For the range of parameters examined here, bubble motion in a shear-thinning fluid is seen to be unsteady with significant shape oscillations. The bubble rises with a secondary motion in the cross-sectional plane along with its primary vertical rise. However, in the Newtonian and shear-thickening fluids, the bubble’s shape is seen to reach a steady-state in a relatively short time and rise with only minor deviations from the vertical path.