Lanting Ji
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Lanting Ji has a total of 51 co-authors. Here are the top co-authors by number of shared publications:
- Xiaoqiang Sun
Jilin University
11 shared publications Xibin Wang
10 shared publications- Yunji Yi
College of Integrated Circuits and Optoelectronic Chips, Shenzhen Technology University, Shenzhen 518118, China
10 shared publications - Chi Wu
Southern Marine Science and Engineering Guangdong Laboratory (Guangzhou), Guangzhou, Guangdong, China
9 shared publications Fei Wang
9 shared publicationsGuobing He
Jilin University
9 shared publications
Latest Publications
- 10 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 43 (22) , 10312-10321
High-Resolution Silicon-Based Optical Fabry-Perot Sensing System for Seawater Temperature Measurement
This paper presents a high-precision temperature sensing system for in-situ monitoring of the deep-sea environments. The system utilizes a silicon-based Fabry-Perot interferometer as its sensing probe and employs a current-modulated distributed feedback laser to generate a linearly periodic wavelength-varying light source. The absorption line of H13C14N gas cell is used as a reference for real-time laser wavelength calibration. Laboratory test results indicate that the sensor has a sensitivity of 75 pm/°C and a resolution of 6.2×10-5°C with a dynamic range of 0 to 35°C. A watertight and pressure-resistant packaging structure was designed and fabricated, capable of enduring hydrostatic pressures up to 115 MPa, as verified through laboratory-simulated pressure tests, thus guaranteeing the system's adaptability to deep-sea environments. Field tests were conducted in the South China Sea, encompassing both short-term profile tests and long-term bottom-sitting tests, with comparative experiments performed against an SBE37 Conductivity-Temperature-Depth (CTD) sensor. The test results demonstrated consistent temperature measurement details between the sensor and the CTD, exhibiting excellent long-term stability and reliability. The system features a simple structure, high resolution, rendering it a promising tool for oceanographic research, resource exploration, and deep-sea environmental monitoring.
- 10 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 43 (22) , 10312-10321
High-Resolution Silicon-Based Optical Fabry-Perot Sensing System for Seawater Temperature Measurement
This paper presents a high-precision temperature sensing system for in-situ monitoring of the deep-sea environments. The system utilizes a silicon-based Fabry-Perot interferometer as its sensing probe and employs a current-modulated distributed feedback laser to generate a linearly periodic wavelength-varying light source. The absorption line of H13C14N gas cell is used as a reference for real-time laser wavelength calibration. Laboratory test results indicate that the sensor has a sensitivity of 75 pm/°C and a resolution of 6.2×10-5°C with a dynamic range of 0 to 35°C. A watertight and pressure-resistant packaging structure was designed and fabricated, capable of enduring hydrostatic pressures up to 115 MPa, as verified through laboratory-simulated pressure tests, thus guaranteeing the system's adaptability to deep-sea environments. Field tests were conducted in the South China Sea, encompassing both short-term profile tests and long-term bottom-sitting tests, with comparative experiments performed against an SBE37 Conductivity-Temperature-Depth (CTD) sensor. The test results demonstrated consistent temperature measurement details between the sensor and the CTD, exhibiting excellent long-term stability and reliability. The system features a simple structure, high resolution, rendering it a promising tool for oceanographic research, resource exploration, and deep-sea environmental monitoring.
- Open Access
- 6 September 2024
- Published by MDPI AG in Journal of Marine Science and Engineering
- Vol. 12 (9) , 1569
In Situ Measurement of Deep-Sea Salinity Using Optical Salinometer Based on Michelson Interferometer
Ocean salinity plays an important role in oceanographic research as one of the fundamental parameters. An optical salinometer based on the Michelson interferometer (MI) suitable for in situ measurement in deep-sea environments is proposed in this work, and it features real-time calibration and multichannel multiplexing using the frequency modulated continuous wave (FMCW) technique. The symmetrical sapphire structure used to withstand deep-sea pressure can not only achieve automatic temperature compensation, but also counteract the changes in optical path length under deep-sea pressure. A model formula suitable for optical salinity demodulation is proposed through the nonlinear least squares fitting method. In vertical profile testing, the optical salinometer demonstrated remarkable tracking performance, achieving an error of less than 0.001 psu. The sensor displays a stable salinity demodulation error within ±0.002 psu during a three-month long-term test at a depth of 4000 m. High stability and resolution make this optical salinometer have broad development prospects in ocean observation.
- 6 September 2024
- Published by MDPI AG in Journal of Marine Science and Engineering
- Vol. 12 (9) , 1569
Open AccessIn Situ Measurement of Deep-Sea Salinity Using Optical Salinometer Based on Michelson Interferometer
Ocean salinity plays an important role in oceanographic research as one of the fundamental parameters. An optical salinometer based on the Michelson interferometer (MI) suitable for in situ measurement in deep-sea environments is proposed in this work, and it features real-time calibration and multichannel multiplexing using the frequency modulated continuous wave (FMCW) technique. The symmetrical sapphire structure used to withstand deep-sea pressure can not only achieve automatic temperature compensation, but also counteract the changes in optical path length under deep-sea pressure. A model formula suitable for optical salinity demodulation is proposed through the nonlinear least squares fitting method. In vertical profile testing, the optical salinometer demonstrated remarkable tracking performance, achieving an error of less than 0.001 psu. The sensor displays a stable salinity demodulation error within ±0.002 psu during a three-month long-term test at a depth of 4000 m. High stability and resolution make this optical salinometer have broad development prospects in ocean observation.
- 16 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (1) , 390-397
High-Resolution Michelson Salinometer Based on Frequency-Modulated Continuous-Wave Interferometry
A novel Michelson salinometer is designed and experimentally demonstrated based on laser frequency-modulated continuous wave (FMCW) technique and cross-correlation algorithm. By modulating the driving current of the distributed feedback laser with FMCW signal, the lasing wavelength changes periodically and scans through the reference and sensing probes. The absorption peak of HF gas is used as reference to calibrate the drift of the laser wavelength in real time to improve the measurement stability. Standard seawater was diluted by titration to evaluate its salinity sensing performance. Experimental results show that the sensor has a resolution of 5×10 -4 g/kg with a measuring range from 26 to 40 g/kg. This sensor, boasting a simple and robust structure, possesses potential application in deep-ocean environments.
- 16 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (1) , 390-397
High-Resolution Michelson Salinometer Based on Frequency-Modulated Continuous-Wave Interferometry
A novel Michelson salinometer is designed and experimentally demonstrated based on laser frequency-modulated continuous wave (FMCW) technique and cross-correlation algorithm. By modulating the driving current of the distributed feedback laser with FMCW signal, the lasing wavelength changes periodically and scans through the reference and sensing probes. The absorption peak of HF gas is used as reference to calibrate the drift of the laser wavelength in real time to improve the measurement stability. Standard seawater was diluted by titration to evaluate its salinity sensing performance. Experimental results show that the sensor has a resolution of 5×10 -4 g/kg with a measuring range from 26 to 40 g/kg. This sensor, boasting a simple and robust structure, possesses potential application in deep-ocean environments.
- 13 June 2023
- Published by Springer Nature in Optical and Quantum Electronics
- Vol. 55 (8) , 1-11
Parametric study on the bimetallic cladding silica waveguide surface plasmon resonance sensor
- 13 June 2023
- Published by Springer Nature in Optical and Quantum Electronics
- Vol. 55 (8) , 1-11
Parametric study on the bimetallic cladding silica waveguide surface plasmon resonance sensor
- 15 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (9) , 9280-9286
Seawater Temperature Measurement System Based on Wavelength Sweeping and Cross Correlation Algorithm
A real-time seawater temperature measurement system based on a wavelength swept distributed feedback laser is developed. The π phase shifted Fiber Bragg grating with a narrow bandwidth of 12 pm is used as the sensing probe. The wavelength is swept by linearly and periodically modulating the driving current of laser with a sawtooth wave signal. The absorption line of H13C14N gas cell provides a standard wavelength to calibrate the swept wavelength in real time to reduces the measurement error induced by the noises or drifts of the laser. Resonance difference between the measurement and the reference in time domain is obtained via a series of digital signal processing such as normalization, derivation, low-pass filtering and cross-correlation operation. Experimental results show that, the sensitivity of the sensor is 16.22 pm/°C, the dynamic range is about 55 °C, the resolution is as high as 0.002 °C, and the thermal response time is ~50 ms. The sensor system is compact, simple, high-resolution and large-dynamic range that has potential application for ocean temperature monitoring.
- 15 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (9) , 9280-9286
Seawater Temperature Measurement System Based on Wavelength Sweeping and Cross Correlation Algorithm
A real-time seawater temperature measurement system based on a wavelength swept distributed feedback laser is developed. The π phase shifted Fiber Bragg grating with a narrow bandwidth of 12 pm is used as the sensing probe. The wavelength is swept by linearly and periodically modulating the driving current of laser with a sawtooth wave signal. The absorption line of H13C14N gas cell provides a standard wavelength to calibrate the swept wavelength in real time to reduces the measurement error induced by the noises or drifts of the laser. Resonance difference between the measurement and the reference in time domain is obtained via a series of digital signal processing such as normalization, derivation, low-pass filtering and cross-correlation operation. Experimental results show that, the sensitivity of the sensor is 16.22 pm/°C, the dynamic range is about 55 °C, the resolution is as high as 0.002 °C, and the thermal response time is ~50 ms. The sensor system is compact, simple, high-resolution and large-dynamic range that has potential application for ocean temperature monitoring.
- 7 March 2023
- Published by Optica Publishing Group in Optics Express
- Vol. 31 (6) , 10358-10367
High-resolution fiber grating pressure sensor with in-situ calibration for deep sea exploration
A high-resolution and wide-range pressure sensor based on π phase-shifted fiber Bragg grating (π-FBG) encapsulated with metal thin-walled cylinder is reported. The sensor has been tested with a wavelength-sweeping distributed feedback laser, photodetector and a H13C14N gas cell. To perceive temperature and pressure synchronously, a pair of π-FBGs are glued on the outer wall of the thin-walled cylinder along the circumferential direction with different angles. The interference of temperature is effectively corrected by a high-precision calibration algorithm. The reported sensor has a sensitivity of 4.42 pm/MPa, a resolution of 0.036% full scale (F.S.), and a repeatability error of 0.045% F.S. in the range of 0-110 MPa that corresponds to an ocean depth resolution of 5 m and a measurement range of eleven thousand meters to cover the deepest trench of the Ocean. The sensor features simplicity, good repeatability, and practicability.
- 7 March 2023
- Published by Optica Publishing Group in Optics Express
- Vol. 31 (6) , 10358-10367
High-resolution fiber grating pressure sensor with in-situ calibration for deep sea exploration
A high-resolution and wide-range pressure sensor based on π phase-shifted fiber Bragg grating (π-FBG) encapsulated with metal thin-walled cylinder is reported. The sensor has been tested with a wavelength-sweeping distributed feedback laser, photodetector and a H13C14N gas cell. To perceive temperature and pressure synchronously, a pair of π-FBGs are glued on the outer wall of the thin-walled cylinder along the circumferential direction with different angles. The interference of temperature is effectively corrected by a high-precision calibration algorithm. The reported sensor has a sensitivity of 4.42 pm/MPa, a resolution of 0.036% full scale (F.S.), and a repeatability error of 0.045% F.S. in the range of 0-110 MPa that corresponds to an ocean depth resolution of 5 m and a measurement range of eleven thousand meters to cover the deepest trench of the Ocean. The sensor features simplicity, good repeatability, and practicability.
- Open Access
- 30 September 2022
- Published by Springer Nature in Research Square
Parametric study on the bimetallic cladding silica waveguide surface plasmon resonance sensor
SPR is dedicated to the measurement of liquid refractive index. Compared with near-infrared and infrared bands, the absorption coefficient of water to visible red band is relatively low. We propose the scheme of silica on silicon and bimetallic layer, which not only reduces the light absorption of water, but also achieves higher sensing performance. In this paper, a parametric study on the bimetallic silver-gold film silica waveguide surface plasmon resonance sensor is performed by using finite element method. Red light that has a low transmission loss in water is adopted as the signal. Magnesium fluoride located between the waveguide and metal film functions as a low RI buffer layer to better couple waveguide mode and SPP mode. The effects of waveguide geometric parameters and operating wavelength on the sensing performance are investigated. Simulation results show that the buffer layer, Cr adhesion layer, operating wavelength and the Ag to Au ratio have a significant influence on surface plasmon resonance. At a bimetal thickness of Au(7nm)Ag(35nm), the sensitivity is as high as 4285 dB/RIU within the refractive index range from 1.358 to 1.365.
- 30 September 2022
- Published by Springer Nature in Research Square
Open AccessParametric study on the bimetallic cladding silica waveguide surface plasmon resonance sensor
SPR is dedicated to the measurement of liquid refractive index. Compared with near-infrared and infrared bands, the absorption coefficient of water to visible red band is relatively low. We propose the scheme of silica on silicon and bimetallic layer, which not only reduces the light absorption of water, but also achieves higher sensing performance. In this paper, a parametric study on the bimetallic silver-gold film silica waveguide surface plasmon resonance sensor is performed by using finite element method. Red light that has a low transmission loss in water is adopted as the signal. Magnesium fluoride located between the waveguide and metal film functions as a low RI buffer layer to better couple waveguide mode and SPP mode. The effects of waveguide geometric parameters and operating wavelength on the sensing performance are investigated. Simulation results show that the buffer layer, Cr adhesion layer, operating wavelength and the Ag to Au ratio have a significant influence on surface plasmon resonance. At a bimetal thickness of Au(7nm)Ag(35nm), the sensitivity is as high as 4285 dB/RIU within the refractive index range from 1.358 to 1.365.
- 24 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (24) , 27482-27488
High-Resolution and Large-Dynamic-Range π-Phase-Shifted FBG Sensor by a Current Modulated Diode Laser
We present a high-resolution and large dynamic range$\pi $ -phase-shifted fiber Bragg grating ($\pi $ -PSFBG) temperature sensor. A current modulated laser diode with a linearized optical frequency sweep is used to interrogate the sensor. The sensor is comprised of a$\pi $ -PSFBG sensing head and an HCN gas cell. The gas cell functions as an absolute frequency reference to compensate for the laser frequency drift. The reflection spectrum is sent to a lock-in amplifier to generate the error signal, proportional to the first order derivative of the spectrum. The center frequency difference that carries sensing information between the$\pi $ -PSFBG and HCN gas cell is calculated by cross-correlation of their error signals. A sinusoidal modulation enables to move the data processing from low-frequency stage to high-frequency stage, by phase-sensitive detection and low-pass filtering, the interferences caused by laser intensity noises and electronic devices’ noises are significantly reduced. In the experiment, a frequency resolution of 3.696 MHz with a 55 GHz mode-hop-free tuning range, is achieved, corresponding to a temperature resolution of 2.6 mK with a dynamic range from 5 to 40 °C.- 24 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (24) , 27482-27488
High-Resolution and Large-Dynamic-Range π-Phase-Shifted FBG Sensor by a Current Modulated Diode Laser
We present a high-resolution and large dynamic range$\pi $ -phase-shifted fiber Bragg grating ($\pi $ -PSFBG) temperature sensor. A current modulated laser diode with a linearized optical frequency sweep is used to interrogate the sensor. The sensor is comprised of a$\pi $ -PSFBG sensing head and an HCN gas cell. The gas cell functions as an absolute frequency reference to compensate for the laser frequency drift. The reflection spectrum is sent to a lock-in amplifier to generate the error signal, proportional to the first order derivative of the spectrum. The center frequency difference that carries sensing information between the$\pi $ -PSFBG and HCN gas cell is calculated by cross-correlation of their error signals. A sinusoidal modulation enables to move the data processing from low-frequency stage to high-frequency stage, by phase-sensitive detection and low-pass filtering, the interferences caused by laser intensity noises and electronic devices’ noises are significantly reduced. In the experiment, a frequency resolution of 3.696 MHz with a 55 GHz mode-hop-free tuning range, is achieved, corresponding to a temperature resolution of 2.6 mK with a dynamic range from 5 to 40 °C.- Open Access
- 21 February 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (4) , 1897
A Broadband Polarization-Insensitive Graphene Modulator Based on Dual Built-in Orthogonal Slots Plasmonic Waveguide
A broadband polarization-insensitive graphene modulator has been proposed. The dual built-in orthogonal slots waveguide allows polarization independence for the transverse electric (TE) mode and the transverse magnetic (TM) mode. Due to the introduction of metal slots in both the vertical and horizontal directions, the optical field as well as the electro-absorption of graphene are enhanced by the plasmonic effect. The proposed electro-optic modulator shows a modulation depth of 0.474 and 0.462 dB/μm for two supported modes, respectively. An ultra-low effective index difference of 0.001 can be achieved within the wavelength range from 1100 to 1900 nm. The 3 dB-bandwidth is estimated to be 101 GHz. The power consumption is 271 fJ/bit at a modulation length of 20 μm. The proposed modulator provides high speed broadband solutions in microwave photonic systems.
- 21 February 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (4) , 1897
Open AccessA Broadband Polarization-Insensitive Graphene Modulator Based on Dual Built-in Orthogonal Slots Plasmonic Waveguide
A broadband polarization-insensitive graphene modulator has been proposed. The dual built-in orthogonal slots waveguide allows polarization independence for the transverse electric (TE) mode and the transverse magnetic (TM) mode. Due to the introduction of metal slots in both the vertical and horizontal directions, the optical field as well as the electro-absorption of graphene are enhanced by the plasmonic effect. The proposed electro-optic modulator shows a modulation depth of 0.474 and 0.462 dB/μm for two supported modes, respectively. An ultra-low effective index difference of 0.001 can be achieved within the wavelength range from 1100 to 1900 nm. The 3 dB-bandwidth is estimated to be 101 GHz. The power consumption is 271 fJ/bit at a modulation length of 20 μm. The proposed modulator provides high speed broadband solutions in microwave photonic systems.
- 1 November 2019
- Published by Elsevier in Optics Communications
- Vol. 451, 41-45
Compact six-mode (de)multiplexer based on cascaded asymmetric Y-junctions with mode rotators
- 1 November 2019
- Published by Elsevier in Optics Communications
- Vol. 451, 41-45
Compact six-mode (de)multiplexer based on cascaded asymmetric Y-junctions with mode rotators