Yibin Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yibin Zhang has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Jianfeng Xu
State Key Laboratory of Intelligent Manufacturing Equipment and Technology, School of Mechanical Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074, China
4 shared publications - Qiyu Peng
Institute of Biomedical Engineering, Shenzhen Bay Laboratory, Shenzhen, China
4 shared publications - Siwei Xie
Institute of Biomedical Engineering, Shenzhen Bay Laboratory, Shenzhen, China
3 shared publications - Xi Zhang
School of Mechanical Science and Engineering, Huazhong University of Science and Technology, Wuhan, China
3 shared publications - Hongsen Yu
School of Mechanical Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074, China
2 shared publications - Huiping Zhao
Institute of Biomedical Engineering, Shenzhen Bay Laboratory, Shenzhen, China
2 shared publications
Latest Publications
- 4 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 10 (4) , 574-581
DOI Self-Calibration Method Based on Intrinsic Radiation for Positron Emission Tomography
Depth-of-interaction (DOI) decoding can reduce localization errors in the Line-of-response (LOR), thereby improving positron emission tomography (PET) image quality, especially in high-resolution PET, long-axial PET, and small-aperture PET systems. Current PET detectors are capable of achieving high-resolution DOI decoding, but most methods rely on collimation calibration for each detector. Calibrating all detectors is labor-intensive and complicates subsequent system maintenance. We aim to achieve DOI collimation for PET detectors based on the intrinsic radiation of 176Lu, which allows us to omit the complex step of calibrating DOI for all detectors. This approach allows DOI calibration to be performed automatically during each system operation, simplifying system maintenance. The pixelated LYSO detector in this study consists of LYSO pixels with dimensions of 2 × 2 × 20 mm3. The detector is arranged in an 8×10 array configuration. We obtained the relationship between intrinsic radiation and DOI through Monte Carlo simulations, and the relationship between the MPPC signal ratio (the relative proportion of light detected by different MPPCs from the same crystal, which changes with DOI) and intrinsic radiation through experiments. This allowed us to establish a conversion function between DOI and the MPPC signal ratio. We verified the DOI resolution through collimation testing and demonstrated the improvement in image quality of the DOI self-calibration based on intrinsic radiation method using the Derenzo phantom experiment. We validated the DOI resolution of our method through mechanical collimation experiments at depths of 4 mm, 10 mm, and 16 mm, achieving an average DOI resolution full width at half maximum (FWHM) of 5.2 mm and a Mean Absolute Error (MAE) of 3.6 mm. The images reconstructed with DOI correction obtained through self-collimation demonstrated significantly improved signal-to-noise ratio and spatial resolution compared to images without DOI correction. Specifically, the spatial resolution at an offset of 45 mm improved from 3.0 mm to 2.1 mm. The DOI self-calibration method based on intrinsic radiation provides a practical and efficient solution for calibrating PET detectors without the need to add complex hardware. It should be noted that this method is only applicable to PET systems with detectors employing LSO or LYSO, and therefore this method is based on spontaneous emission of 176Lu. This method has the potential to improve the image quality of PET systems and can be readily integrated into existing detector designs.
- 4 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 10 (4) , 574-581
DOI Self-Calibration Method Based on Intrinsic Radiation for Positron Emission Tomography
Depth-of-interaction (DOI) decoding can reduce localization errors in the Line-of-response (LOR), thereby improving positron emission tomography (PET) image quality, especially in high-resolution PET, long-axial PET, and small-aperture PET systems. Current PET detectors are capable of achieving high-resolution DOI decoding, but most methods rely on collimation calibration for each detector. Calibrating all detectors is labor-intensive and complicates subsequent system maintenance. We aim to achieve DOI collimation for PET detectors based on the intrinsic radiation of 176Lu, which allows us to omit the complex step of calibrating DOI for all detectors. This approach allows DOI calibration to be performed automatically during each system operation, simplifying system maintenance. The pixelated LYSO detector in this study consists of LYSO pixels with dimensions of 2 × 2 × 20 mm3. The detector is arranged in an 8×10 array configuration. We obtained the relationship between intrinsic radiation and DOI through Monte Carlo simulations, and the relationship between the MPPC signal ratio (the relative proportion of light detected by different MPPCs from the same crystal, which changes with DOI) and intrinsic radiation through experiments. This allowed us to establish a conversion function between DOI and the MPPC signal ratio. We verified the DOI resolution through collimation testing and demonstrated the improvement in image quality of the DOI self-calibration based on intrinsic radiation method using the Derenzo phantom experiment. We validated the DOI resolution of our method through mechanical collimation experiments at depths of 4 mm, 10 mm, and 16 mm, achieving an average DOI resolution full width at half maximum (FWHM) of 5.2 mm and a Mean Absolute Error (MAE) of 3.6 mm. The images reconstructed with DOI correction obtained through self-collimation demonstrated significantly improved signal-to-noise ratio and spatial resolution compared to images without DOI correction. Specifically, the spatial resolution at an offset of 45 mm improved from 3.0 mm to 2.1 mm. The DOI self-calibration method based on intrinsic radiation provides a practical and efficient solution for calibrating PET detectors without the need to add complex hardware. It should be noted that this method is only applicable to PET systems with detectors employing LSO or LYSO, and therefore this method is based on spontaneous emission of 176Lu. This method has the potential to improve the image quality of PET systems and can be readily integrated into existing detector designs.
- 26 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-10
Depth of Interaction in PET Detector Design: Performance Optimization With Light-Sharing Window
The spatial resolution and image quality of positron emission tomography (PET) scanners are significantly affected by the uncertainties in the depth-of-interaction (DOI) measurement in PET detectors. The existing methods for implementing the DOI measurements mainly include dual-layer and dual-end crystal detectors. However, dual-layer crystal detectors have poor DOI resolution and limited performance improvement, whereas dual-end crystal detectors have a complex structure and high cost. To address these shortcomings, this paper proposes a cost-effective detector with a light-sharing window comprising a simple structure and good DOI resolution. The proposed detector leverages the ratio of photons passing through the internal light-sharing window at different interaction depths to determine the DOI. The proposed design is validated using an LYSO scintillation crystal detector, with a single crystal of size 2 mm × 2 mm × 20 mm, and a feedforward neural network. The results show that the DOI resolution achieve a full-width at half-maximum of 3.0 mm and a mean absolute error of 2.1 mm, which significantly improves the PET image quality. Moreover, the results also indicate a direct correlation between the energy and time resolution of the detector and the DOI. Furthermore, the results show that the proposed detector calibrates energy and time measurements through DOI, thus improving its performance and providing better PET image quality. The methods and results presented in this study can help in further improving the performance of PET detectors and PET scanners.
- 26 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-10
Depth of Interaction in PET Detector Design: Performance Optimization With Light-Sharing Window
The spatial resolution and image quality of positron emission tomography (PET) scanners are significantly affected by the uncertainties in the depth-of-interaction (DOI) measurement in PET detectors. The existing methods for implementing the DOI measurements mainly include dual-layer and dual-end crystal detectors. However, dual-layer crystal detectors have poor DOI resolution and limited performance improvement, whereas dual-end crystal detectors have a complex structure and high cost. To address these shortcomings, this paper proposes a cost-effective detector with a light-sharing window comprising a simple structure and good DOI resolution. The proposed detector leverages the ratio of photons passing through the internal light-sharing window at different interaction depths to determine the DOI. The proposed design is validated using an LYSO scintillation crystal detector, with a single crystal of size 2 mm × 2 mm × 20 mm, and a feedforward neural network. The results show that the DOI resolution achieve a full-width at half-maximum of 3.0 mm and a mean absolute error of 2.1 mm, which significantly improves the PET image quality. Moreover, the results also indicate a direct correlation between the energy and time resolution of the detector and the DOI. Furthermore, the results show that the proposed detector calibrates energy and time measurements through DOI, thus improving its performance and providing better PET image quality. The methods and results presented in this study can help in further improving the performance of PET detectors and PET scanners.
- Open Access
Development and Evaluation of a Dual-Layer-Offset PET Detector Constructed with Different Reflectors
Dual-layer-offset or multi-layer-offset design of a PET detector can improve spatial resolution while maintaining high sensitivity. In this study, three dual-layer-offset LYSO detectors with three different reflectors (ESR, Toray, and BaSO4) were developed. The top layer consisted of a 17 × 17 array of crystals 1 × 1 × 6.5 mm3 in size and the bottom layer consisted of an 18 × 18 array of crystals 1 × 1 × 9.5 mm3 in size. Neither light guides nor optical glue were used between the two layers of crystals. A custom-designed electronics system, composed of a 6 × 6 SiPM array, two FPC cables, and a custom-designed data processing module, was used to read out signals. An optimized interaction-decoding algorithm using the center of gravity to determine the position and threshold of analog signals for timing methods was applied to generate decoding flood histograms. The detector performances, in terms of peak to valley ratio of the flood histograms and energy resolutions, were calculated and compared. The dual-layer-offset PET detector constructed with BaSO4 reflectors performed much better than the other two reflectors in both crystal identification and energy resolution. The average peak-to-valley ratio and the energy resolution were approximately 7 and 11%, respectively. In addition, the crystals in the bottom layer showed better performance at crystal identification than those in the top layer. This study can act as a reference providing guidance in choosing scintillator reflectors for multi-layer dedicated DOI detectors designed for small-animal PET imaging.
Open AccessDevelopment and Evaluation of a Dual-Layer-Offset PET Detector Constructed with Different Reflectors
Dual-layer-offset or multi-layer-offset design of a PET detector can improve spatial resolution while maintaining high sensitivity. In this study, three dual-layer-offset LYSO detectors with three different reflectors (ESR, Toray, and BaSO4) were developed. The top layer consisted of a 17 × 17 array of crystals 1 × 1 × 6.5 mm3 in size and the bottom layer consisted of an 18 × 18 array of crystals 1 × 1 × 9.5 mm3 in size. Neither light guides nor optical glue were used between the two layers of crystals. A custom-designed electronics system, composed of a 6 × 6 SiPM array, two FPC cables, and a custom-designed data processing module, was used to read out signals. An optimized interaction-decoding algorithm using the center of gravity to determine the position and threshold of analog signals for timing methods was applied to generate decoding flood histograms. The detector performances, in terms of peak to valley ratio of the flood histograms and energy resolutions, were calculated and compared. The dual-layer-offset PET detector constructed with BaSO4 reflectors performed much better than the other two reflectors in both crystal identification and energy resolution. The average peak-to-valley ratio and the energy resolution were approximately 7 and 11%, respectively. In addition, the crystals in the bottom layer showed better performance at crystal identification than those in the top layer. This study can act as a reference providing guidance in choosing scintillator reflectors for multi-layer dedicated DOI detectors designed for small-animal PET imaging.
- Open Access
Optical Simulation and Experimental Assessment with Time–Walk Correction of TOF–PET Detectors with Multi-Ended Readouts
As a commonly used solution, the multi-ended readout can measure the depth-of-interaction (DOI) for positron emission tomography (PET) detectors. In the present study, the effects of the multi-ended readout design were investigated using the leading-edge discriminator (LED) triggers on the timing performance of time-of-flight (TOF) PET detectors. At the very first, the photon transmission model of the four detectors, namely, single-ended readout, dual-ended readout, side dual-ended readout, and triple-ended readout, was established in Tracepro. The optical simulation revealed that the light output of the multi-ended readout was higher. Meanwhile, the readout circuit could be triggered earlier. Especially, in the triple-ended readout, the light output at 0.5 ns was observed to be nearly twice that of the single-ended readout after the first scintillating photon was generated. Subsequently, a reference detector was applied to test the multi-ended readout detectors that were constructed from a 6 × 6 × 25 mm3 LYSO crystal. Each module is composed of a crystal coupled with multiple SiPMs. Accordingly, its timing performance was improved by approximately 10% after the compensation of fourth-order polynomial fitting. Finally, the compensated full-width-at-half-maximum (FWHM) coincidence timing resolutions (CTR) of the dual-ended readout, side dual-ended readout, and triple-ended readout were 216.9 ps, 231.0 ps, and 203.6 ps, respectively.
Open AccessOptical Simulation and Experimental Assessment with Time–Walk Correction of TOF–PET Detectors with Multi-Ended Readouts
As a commonly used solution, the multi-ended readout can measure the depth-of-interaction (DOI) for positron emission tomography (PET) detectors. In the present study, the effects of the multi-ended readout design were investigated using the leading-edge discriminator (LED) triggers on the timing performance of time-of-flight (TOF) PET detectors. At the very first, the photon transmission model of the four detectors, namely, single-ended readout, dual-ended readout, side dual-ended readout, and triple-ended readout, was established in Tracepro. The optical simulation revealed that the light output of the multi-ended readout was higher. Meanwhile, the readout circuit could be triggered earlier. Especially, in the triple-ended readout, the light output at 0.5 ns was observed to be nearly twice that of the single-ended readout after the first scintillating photon was generated. Subsequently, a reference detector was applied to test the multi-ended readout detectors that were constructed from a 6 × 6 × 25 mm3 LYSO crystal. Each module is composed of a crystal coupled with multiple SiPMs. Accordingly, its timing performance was improved by approximately 10% after the compensation of fourth-order polynomial fitting. Finally, the compensated full-width-at-half-maximum (FWHM) coincidence timing resolutions (CTR) of the dual-ended readout, side dual-ended readout, and triple-ended readout were 216.9 ps, 231.0 ps, and 203.6 ps, respectively.