Mark Robert Stone
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Mark Robert Stone has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Kevin G. Thompson
Research Institute for Sport and Exercise, University of Canberra, Canberra, Australia
8 shared publications Alan St Clair Gibson
7 shared publications- Kevin Thomas
Department of Sport, Exercise and Rehabilitation, Northumbria University, Newcastle-upon-Tyne, UK
7 shared publications Les Ansley
4 shared publicationsKeiran J. Henderson
Human Performance, Exercise and Wellbeing Centre, Buckinghamshire New University, Queen Alexandra Road, High Wycombe, Buckinghamshire, HP11 2JZ, UK
3 shared publications- Michael Wilkinson
Northumbria University, Newcastle upon Tyne, UK
3 shared publications
Latest Publications
- Open Access
- 6 September 2022
- Published by Springer Nature in Sport Sciences for Health
- Vol. 19 (4) , 1109-1117
Reliability of electromyography during 2000 m rowing ergometry
Purpose: This study aimed to investigate the reliability of surface electromyography (EMG) assessed at seven muscles during three repeated 2000 m rowing ergometer sessions. Methods: Twelve male well-trained rowers participated in a repeated measures design, performing three 2000 m rowing ergometer sessions interspersed by 3–7 days (S1, S2, S3). Surface electrodes were attached to the gastrocnemius, biceps femoris, gluteus maximus, erector spinae, vastus medialis, rectus abdominis and latissimus dorsi for EMG analysis. Results: No differences existed between 2000 m sessions for EMG amplitude for any of the seven muscles (p = 0.146–0.979). Mean coefficient of variation of EMG for 6 of 7 muscles was ‘acceptable’ (12.3–18.6%), although classed as ‘weak’ for gastrocnemius (28.6%). Mean intra-class correlation coefficient values across muscles ranged from ‘moderate’ to ‘very large’ (0.31–0.89). Within-session EMG activation rates of vastus medialis were greater during 0–500 m and 1500–2000 m segments, compared with 500–1000 m and 1000–1500 m (p < 0.05). Values for biceps femoris and gluteus maximus were significantly higher during 1500–2000 m compared to 500–1000 m and 1000–1500 m (p < 0.05). The general pattern was for higher activation rates during 0–500 m and 1500–2000 m compared to 500–1000 m and 1000–1500 m. However, there were no between-sessions differences in EMG for any of the 500 m segments (p > 0.05). Conclusion: Reliability of EMG values over repeated 2000 m sessions was generally ‘acceptable’. However, EMG was seemingly not sensitive enough to detect potential changes in neural activation between-sessions, with respect to changes in pacing strategy.
- 6 September 2022
- Published by Springer Nature in Sport Sciences for Health
- Vol. 19 (4) , 1109-1117
Open AccessReliability of electromyography during 2000 m rowing ergometry
Purpose: This study aimed to investigate the reliability of surface electromyography (EMG) assessed at seven muscles during three repeated 2000 m rowing ergometer sessions. Methods: Twelve male well-trained rowers participated in a repeated measures design, performing three 2000 m rowing ergometer sessions interspersed by 3–7 days (S1, S2, S3). Surface electrodes were attached to the gastrocnemius, biceps femoris, gluteus maximus, erector spinae, vastus medialis, rectus abdominis and latissimus dorsi for EMG analysis. Results: No differences existed between 2000 m sessions for EMG amplitude for any of the seven muscles (p = 0.146–0.979). Mean coefficient of variation of EMG for 6 of 7 muscles was ‘acceptable’ (12.3–18.6%), although classed as ‘weak’ for gastrocnemius (28.6%). Mean intra-class correlation coefficient values across muscles ranged from ‘moderate’ to ‘very large’ (0.31–0.89). Within-session EMG activation rates of vastus medialis were greater during 0–500 m and 1500–2000 m segments, compared with 500–1000 m and 1000–1500 m (p < 0.05). Values for biceps femoris and gluteus maximus were significantly higher during 1500–2000 m compared to 500–1000 m and 1000–1500 m (p < 0.05). The general pattern was for higher activation rates during 0–500 m and 1500–2000 m compared to 500–1000 m and 1000–1500 m. However, there were no between-sessions differences in EMG for any of the 500 m segments (p > 0.05). Conclusion: Reliability of EMG values over repeated 2000 m sessions was generally ‘acceptable’. However, EMG was seemingly not sensitive enough to detect potential changes in neural activation between-sessions, with respect to changes in pacing strategy.
- Open Access
- 9 September 2019
- Published by Wiley in Translational Sports Medicine
- Vol. 3 (1) , 9-15
A neuromuscular training program enhances dynamic neuromuscular control and physical performance in court‐sport athletes
- 9 September 2019
- Published by Wiley in Translational Sports Medicine
- Vol. 3 (1) , 9-15
Open AccessA neuromuscular training program enhances dynamic neuromuscular control and physical performance in court‐sport athletes
- 6 December 2017
- Published by Springer Nature in European Journal of Applied Physiology
- Vol. 118 (2) , 339-347
The use of the CR-10 scale to allow self-regulation of isometric exercise intensity in pre-hypertensive and hypertensive participants
Isometric exercise (IE) has been shown to lower blood pressure (BP). Using equipment with force output displays, intensity is usually regulated at 30% maximal voluntary contraction (MVC); however, the cost of programmable equipment and their requirement for maximal contractions presents limitations. A simple, cost-effective alternative deserves investigation. The purpose of this study was (1) to explore the relationship between %MVC, change in systolic BP (ΔSBP), and perceived exertion (CR-10) and (2) to assess the validity of self-regulation of intensity during isometric hand-grip exercise.
- 6 December 2017
- Published by Springer Nature in European Journal of Applied Physiology
- Vol. 118 (2) , 339-347
The use of the CR-10 scale to allow self-regulation of isometric exercise intensity in pre-hypertensive and hypertensive participants
Isometric exercise (IE) has been shown to lower blood pressure (BP). Using equipment with force output displays, intensity is usually regulated at 30% maximal voluntary contraction (MVC); however, the cost of programmable equipment and their requirement for maximal contractions presents limitations. A simple, cost-effective alternative deserves investigation. The purpose of this study was (1) to explore the relationship between %MVC, change in systolic BP (ΔSBP), and perceived exertion (CR-10) and (2) to assess the validity of self-regulation of intensity during isometric hand-grip exercise.
- 1 August 2017
- Published by Wolters Kluwer Health in Blood Pressure Monitoring
- Vol. 22 (4) , 244-245
Response to
- 1 August 2017
- Published by Wolters Kluwer Health in Blood Pressure Monitoring
- Vol. 22 (4) , 244-245
Response to
- 1 June 2017
- Published by Wolters Kluwer Health in Blood Pressure Monitoring
- Vol. 22 (3) , 169-172
Reproducibility of 24-h ambulatory blood pressure and measures of autonomic function
Determining the number of familiarization sessions required for accurate recordings of ambulatory blood pressure monitoring and autonomic function is a prerequisite for the appropriate design of intervention studies. The benefit of familiarization trials remains largely unexplored. The objective of the current investigation was to assess the reproducibility of 24-h ambulatory blood pressure, 24-h heart rate variability (HRV) and resting measurements of HRV and blood pressure variability (BPV). Eleven prehypertensive and hypertensive adults participated. Ambulatory blood pressure and HRV were measured across 24 h on four occasions. In addition, 5-min resting measures of HRV and BPV were recorded and analysed. Variability between consecutive pairs of trials was calculated. The typical error induced by ambulatory recordings of systolic blood pressure reduced over time (3.8–2.8 mmHg). The greatest effect of familiarization was observed at night. Ambulatory HRV was more reproducible than resting measures. The most reproducible markers were root mean square of successive differences [coefficient of variation (CV): 13.2–10%] and high frequency normalized units (CV: 15.2–6.4%), with the percentage of adjacent NN intervals differing by more than 50 ms showing the poorest reproducibility (CV: 23.9–20.7%). Overall BPV (SD) was more reproducible than the frequency domain low frequency component. Familiarization trials are required for the most accurate recordings of both 24-h ambulatory blood pressure monitoring and HRV. Ambulatory HRV provide superior reproducibility to resting measurements.
- 1 June 2017
- Published by Wolters Kluwer Health in Blood Pressure Monitoring
- Vol. 22 (3) , 169-172
Reproducibility of 24-h ambulatory blood pressure and measures of autonomic function
Determining the number of familiarization sessions required for accurate recordings of ambulatory blood pressure monitoring and autonomic function is a prerequisite for the appropriate design of intervention studies. The benefit of familiarization trials remains largely unexplored. The objective of the current investigation was to assess the reproducibility of 24-h ambulatory blood pressure, 24-h heart rate variability (HRV) and resting measurements of HRV and blood pressure variability (BPV). Eleven prehypertensive and hypertensive adults participated. Ambulatory blood pressure and HRV were measured across 24 h on four occasions. In addition, 5-min resting measures of HRV and BPV were recorded and analysed. Variability between consecutive pairs of trials was calculated. The typical error induced by ambulatory recordings of systolic blood pressure reduced over time (3.8–2.8 mmHg). The greatest effect of familiarization was observed at night. Ambulatory HRV was more reproducible than resting measures. The most reproducible markers were root mean square of successive differences [coefficient of variation (CV): 13.2–10%] and high frequency normalized units (CV: 15.2–6.4%), with the percentage of adjacent NN intervals differing by more than 50 ms showing the poorest reproducibility (CV: 23.9–20.7%). Overall BPV (SD) was more reproducible than the frequency domain low frequency component. Familiarization trials are required for the most accurate recordings of both 24-h ambulatory blood pressure monitoring and HRV. Ambulatory HRV provide superior reproducibility to resting measurements.
- Open Access
- 9 March 2017
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 12 (3) , e0173120
Exploring the performance reserve: Effect of different magnitudes of power output deception on 4,000 m cycling time-trial performance
The aim of the present study was to investigate whether a magnitude of deception of 5% in power output would lead to a greater reduction in the amount of time taken for participants to complete a 4000 m cycling TT than a magnitude of deception of 2% in power output, which we have previously shown can lead to a small change in 4000 m cycling TT performance. Ten trained male cyclists completed four, 4000 m cycling TTs. The first served as a habituation and the second as a baseline for future trials. During trials three and four participants raced against a pacer which was set, in a randomized order, at a mean power output equal to 2% (+2% TT) or 5% (+5% TT) higher than their baseline performance. However participants were misled into believing that the power output of the pacer was an accurate representation of their baseline performance on both occasions. Cardiorespiratory responses were recorded throughout each TT, and used to estimate energy contribution from aerobic and anaerobic metabolism. Participants were able to finish the +2% TT in a significantly shorter duration than at baseline (p = 0.01), with the difference in performance likely attributable to a greater anaerobic contribution to total power output (p = 0.06). There was no difference in performance between the +5% TT and +2% TT or baseline trials. Results suggest that a performance reserve is conserved, involving anaerobic energy contribution, which can be utilised given a belief that the exercise will be sustainable however there is an upper limit to how much deception can be tolerated. These findings have implications for performance enhancement in athletes and for our understanding of the nature of fatigue during high-intensity exercise.
- 9 March 2017
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 12 (3) , e0173120
Open AccessExploring the performance reserve: Effect of different magnitudes of power output deception on 4,000 m cycling time-trial performance
The aim of the present study was to investigate whether a magnitude of deception of 5% in power output would lead to a greater reduction in the amount of time taken for participants to complete a 4000 m cycling TT than a magnitude of deception of 2% in power output, which we have previously shown can lead to a small change in 4000 m cycling TT performance. Ten trained male cyclists completed four, 4000 m cycling TTs. The first served as a habituation and the second as a baseline for future trials. During trials three and four participants raced against a pacer which was set, in a randomized order, at a mean power output equal to 2% (+2% TT) or 5% (+5% TT) higher than their baseline performance. However participants were misled into believing that the power output of the pacer was an accurate representation of their baseline performance on both occasions. Cardiorespiratory responses were recorded throughout each TT, and used to estimate energy contribution from aerobic and anaerobic metabolism. Participants were able to finish the +2% TT in a significantly shorter duration than at baseline (p = 0.01), with the difference in performance likely attributable to a greater anaerobic contribution to total power output (p = 0.06). There was no difference in performance between the +5% TT and +2% TT or baseline trials. Results suggest that a performance reserve is conserved, involving anaerobic energy contribution, which can be utilised given a belief that the exercise will be sustainable however there is an upper limit to how much deception can be tolerated. These findings have implications for performance enhancement in athletes and for our understanding of the nature of fatigue during high-intensity exercise.
- 1 March 2016
- Published by Human Kinetics in International Journal of Sports Physiology and Performance
- Vol. 11 (2) , 273-275
Asymmetry of Cerebral Hemodynamic Response to Incremental Cycling Exercise
Purpose: Exercise is known to result in hemodynamic changes in the bilateral prefrontal cortex. The aim of this study was to investigate hemodynamic changes in right and left hemispheres of the prefrontal cortex (PFC) during incremental cycling exercise.Methods: After 10 min rest, 9 participants (mean age 26.6 ± 2.5 y, mass 77.5 ± 9.7 kg, stature 1.79 ± 0.9 m) cycled at 100–150 W for 4 min. Thereafter, resistance was increased by 25 W every 4 min until exhaustion (EXH). Respiratory exchange and concentrations of oxy- ([HbO2]), deoxy- ([(HHb]), and total hemoglobin ([Hbtot]) in the PFC were continuously measured. Data were averaged for 60 s at rest and preceding ventilatory threshold 1 (VT1), VT2, and volitional EXH and after 5 min recovery. Subjective ratings of affect were measured at VT1, VT2, VT1 minus 25 W (VT1-25W), and VT2 plus 25 W (VT2+25W).Results: There were no between-hemispheres differences in [HbO2] or [Hbtot] at rest, VT1, or recovery or in [HHb] at any point. Right-hemisphere [HbO2] and [Hbtot] were significantly greater than left at VT2 (P = .01 and P = .02) and EXH (P = .03 and P = .02). Affect was significantly greater at VT1-25W vs VT2 and VT2+25W and at VT1 and VT2 vs VT2+25W (P < .01–.03).Conclusions: To the authors’ knowledge, this is the first study to describe an exercise-state-dependent change in PFC asymmetry during incremental exercise. The asymmetry detected coincided with a decrease in affect scores in agreement with the PFC-asymmetry hypothesis.
- 1 March 2016
- Published by Human Kinetics in International Journal of Sports Physiology and Performance
- Vol. 11 (2) , 273-275
Asymmetry of Cerebral Hemodynamic Response to Incremental Cycling Exercise
Purpose: Exercise is known to result in hemodynamic changes in the bilateral prefrontal cortex. The aim of this study was to investigate hemodynamic changes in right and left hemispheres of the prefrontal cortex (PFC) during incremental cycling exercise.Methods: After 10 min rest, 9 participants (mean age 26.6 ± 2.5 y, mass 77.5 ± 9.7 kg, stature 1.79 ± 0.9 m) cycled at 100–150 W for 4 min. Thereafter, resistance was increased by 25 W every 4 min until exhaustion (EXH). Respiratory exchange and concentrations of oxy- ([HbO2]), deoxy- ([(HHb]), and total hemoglobin ([Hbtot]) in the PFC were continuously measured. Data were averaged for 60 s at rest and preceding ventilatory threshold 1 (VT1), VT2, and volitional EXH and after 5 min recovery. Subjective ratings of affect were measured at VT1, VT2, VT1 minus 25 W (VT1-25W), and VT2 plus 25 W (VT2+25W).Results: There were no between-hemispheres differences in [HbO2] or [Hbtot] at rest, VT1, or recovery or in [HHb] at any point. Right-hemisphere [HbO2] and [Hbtot] were significantly greater than left at VT2 (P = .01 and P = .02) and EXH (P = .03 and P = .02). Affect was significantly greater at VT1-25W vs VT2 and VT2+25W and at VT1 and VT2 vs VT2+25W (P < .01–.03).Conclusions: To the authors’ knowledge, this is the first study to describe an exercise-state-dependent change in PFC asymmetry during incremental exercise. The asymmetry detected coincided with a decrease in affect scores in agreement with the PFC-asymmetry hypothesis.
- 1 March 2015
- Published by Wolters Kluwer Health in Medicine & Science in Sports & Exercise
- Vol. 47 (3) , 537-546
Central and Peripheral Fatigue in Male Cyclists after 4-, 20-, and 40-km Time Trials
Ale cyclists completed 4-, 20-, and 40-km simulated time trials (TTs). Pre- and immediately post-TT (30 min)....
- 1 March 2015
- Published by Wolters Kluwer Health in Medicine & Science in Sports & Exercise
- Vol. 47 (3) , 537-546
Central and Peripheral Fatigue in Male Cyclists after 4-, 20-, and 40-km Time Trials
Ale cyclists completed 4-, 20-, and 40-km simulated time trials (TTs). Pre- and immediately post-TT (30 min)....
- 2 October 2013
- Published by Springer Nature in European Journal of Applied Physiology
- Vol. 113 (12) , 3001-3010
The effect of an even-pacing strategy on exercise tolerance in well-trained cyclists
Purpose Previous research has suggested that the optimal pacing strategy for self-paced exercise lasting >4 min is a uniform distribution of work, but this posit is not well established for prolonged endurance events. This study examined the utility of even pacing during 20 km cycling time trials (TTs). Methods Fifteen well-trained male cyclists (\(\dot{V}\)O2max = 4.80 ± 0.38 L min−1) completed three best effort self-paced (SP) simulated 20 km TTs, followed by two even-paced trials. In one even-paced trial, participants cycled to exhaustion (EPtlim) at a fixed intensity equivalent to their best SP performance. In the other EP trial, participants were instructed to maintain this target intensity for a distance of 20 km, but the actual intensity was free to vary depending on the effort and cadence of the cyclist (EP-maintained). Cardiorespiratory, blood lactate and perceptual (RPE and affect) measures were assessed throughout. Results Nine out of fifteen cyclists failed the EPtlim task, completing 51–83 % (10.3–15.3 km) of the work done in their SP trial. Failure as a result of even pacing was associated with a faster rise in blood lactate, attainment of a higher relative intensity during SP and a moderate fast starting strategy. This failure was independent of the nature of the even-paced task. Conclusion By adopting an uneven, parabolic distribution of work, cyclists in this study were able to achieve an average intensity during self-paced exercise in excess of their maximum sustainable power output. A subsequent matched even-paced bout resulted in cumulative metabolic stress that could not be managed by moment-to-moment changes in power output. These results challenge the notion that strict even pacing is optimal for endurance time trial events.- 2 October 2013
- Published by Springer Nature in European Journal of Applied Physiology
- Vol. 113 (12) , 3001-3010
The effect of an even-pacing strategy on exercise tolerance in well-trained cyclists
Purpose Previous research has suggested that the optimal pacing strategy for self-paced exercise lasting >4 min is a uniform distribution of work, but this posit is not well established for prolonged endurance events. This study examined the utility of even pacing during 20 km cycling time trials (TTs). Methods Fifteen well-trained male cyclists (\(\dot{V}\)O2max = 4.80 ± 0.38 L min−1) completed three best effort self-paced (SP) simulated 20 km TTs, followed by two even-paced trials. In one even-paced trial, participants cycled to exhaustion (EPtlim) at a fixed intensity equivalent to their best SP performance. In the other EP trial, participants were instructed to maintain this target intensity for a distance of 20 km, but the actual intensity was free to vary depending on the effort and cadence of the cyclist (EP-maintained). Cardiorespiratory, blood lactate and perceptual (RPE and affect) measures were assessed throughout. Results Nine out of fifteen cyclists failed the EPtlim task, completing 51–83 % (10.3–15.3 km) of the work done in their SP trial. Failure as a result of even pacing was associated with a faster rise in blood lactate, attainment of a higher relative intensity during SP and a moderate fast starting strategy. This failure was independent of the nature of the even-paced task. Conclusion By adopting an uneven, parabolic distribution of work, cyclists in this study were able to achieve an average intensity during self-paced exercise in excess of their maximum sustainable power output. A subsequent matched even-paced bout resulted in cumulative metabolic stress that could not be managed by moment-to-moment changes in power output. These results challenge the notion that strict even pacing is optimal for endurance time trial events.- 1 March 2012
- Published by Wolters Kluwer Health in Medicine & Science in Sports & Exercise
- Vol. 44 (3) , 534-541
Effects of Deception on Exercise Performance
Ed male cyclists each completed four 4000-m time trials. The first trial was a habituation and the data from the second trial was used to form a baseline (BL). During trials 3 and 4, participants raced against an avatar, which they were informed represented their BL performance. However, whereas one of these trials was an accurate (ACC) representation of BL, the power output in the other trial was set at 102% of BL and formed the deception condition (DEC). Oxygen uptake and RER were measured continuously and used to determine aerobic and anaerobic contributions to power output. Results There was a significant difference between trials for time to completion (F = 15.3, P = 0.00). Participants completed DEC more quickly than BL (90% CI = 2.1–10.1 s) and ACC (90% CI = 1.5–5.4 s) and completed ACC more quickly than BL (90% CI = 0.5–4.8 s). The difference in performance between DEC and ACC was attributable to a greater anaerobic contribution to power output at 90% of the total distance (F = 5.3, P = 0.02, 90% CI = 4–37 W). Conclusions The provision of surreptitiously augmented feedback derived from a previous performance reduces time taken for cyclists to accomplish a time trial of known duration. This suggests that cyclists operate with a metabolic reserve even during maximal time trials and that this reserve can be accessed after deception....
- 1 March 2012
- Published by Wolters Kluwer Health in Medicine & Science in Sports & Exercise
- Vol. 44 (3) , 534-541
Effects of Deception on Exercise Performance
Ed male cyclists each completed four 4000-m time trials. The first trial was a habituation and the data from the second trial was used to form a baseline (BL). During trials 3 and 4, participants raced against an avatar, which they were informed represented their BL performance. However, whereas one of these trials was an accurate (ACC) representation of BL, the power output in the other trial was set at 102% of BL and formed the deception condition (DEC). Oxygen uptake and RER were measured continuously and used to determine aerobic and anaerobic contributions to power output. Results There was a significant difference between trials for time to completion (F = 15.3, P = 0.00). Participants completed DEC more quickly than BL (90% CI = 2.1–10.1 s) and ACC (90% CI = 1.5–5.4 s) and completed ACC more quickly than BL (90% CI = 0.5–4.8 s). The difference in performance between DEC and ACC was attributable to a greater anaerobic contribution to power output at 90% of the total distance (F = 5.3, P = 0.02, 90% CI = 4–37 W). Conclusions The provision of surreptitiously augmented feedback derived from a previous performance reduces time taken for cyclists to accomplish a time trial of known duration. This suggests that cyclists operate with a metabolic reserve even during maximal time trials and that this reserve can be accessed after deception....