Héctor Sanz-Fraile
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Héctor Sanz-Fraile has a total of 42 co-authors. Here are the top co-authors by number of shared publications:
- Jorge Otero
Unit of Biophysics and Bioengineering, School of Medicine and Health Sciences, University of Barcelona, Casanova 143, 08036 Barcelona, Spain
4 shared publications - Ramon Farré
Unitat de Biofísica i Bioenginyeria, Facultat de Medicina i Ciències de la Salut, Universitat de Barcelona, Barcelona, Spain
4 shared publications - Anna Ulldemolins
Unitat de Biofísica i Bioenginyeria, Facultat de Medicina i Ciències de la Salut, Universitat de Barcelona, 08036 Barcelona, Spain
3 shared publications - Isaac Almendros
Universitat de Barcelona, Spain
3 shared publications - Bryan Falcones
Universitat de Barcelona, Barcelona, Spain
2 shared publications - Daniel Navajas
Unitat de Biofísica i Bioenginyeria, Facultat de Medicina i Ciències de la Salut, Universitat de Barcelona, 08036 Barcelona, Spain
2 shared publications
Latest Publications
- Open Access
- 17 September 2026
- Published by Springer Nature in Applied Microbiology and Biotechnology
Design and sterilization of 3D-printed glass-bottomed multiwells for cell culture and immunostaining
3D printers are increasingly found in wet laboratories, allowing researchers to print devices for their research needs. To make those devices suitable for cell culture, they should ideally be sterilized following protocols used in cell biology labs. Simultaneously, any sterilization protocol should maintain the mechanical stability of the printed device. Here we have studied two 3D printing materials, Poly-Lactic Acid (PLA) polymers and Acrylonitrile Butadiene Styrene (ABS)-like Photopolymer resins, which are prevalently used in 3D printing. We have subjected 3D-printed specimens of each material to UV light exposure, ethanol immersion and autoclaving, and have verified their mechanical stability at the macro- and nanoscales using tensile testing and nanoindentation. ABS-like resin (0.31 ± 0.07 GPa) remained mechanically viable after UV illumination (1.19 ± 0.02 GPa) or autoclaving (0.36 ± 0.05 GPa), but deteriorated when submerged in ethanol (0.01 ± 0.00 GPa). Nevertheless, sterilized ABS-printed devices probed to be toxic to cells, an effect that could not be prevented when switching to the inert Formlabs Grey resin. On the other hand, PLA specimens (1.22 ± 0.09 GPa) remained mechanically viable after ethanol (1.23 ± 0.15 GPa) and UV (1.21 ± 0.01 GPa) challenge but deteriorated in the autoclave (0.75 ± 0.20 GPa). This effect was prevented when switching to Heat-Treated PLA (HTPLA) polymers (1.07 ± 0.13 GPa). Sterilization of HTPLA-printed devices with a sequence of autoclave, ethanol and UV treatments deemed them suitable for long-term cell culture, as confirmed by measuring cell morphologies and doubling times (21.06 ± 4.66 h). Altogether, we provide here designs for in-house 3D-printing and assembly of glass-bottomed multiwells based on HTPLA and detail optimal sterilization protocols for their use in long-term cell culture and immunostaining. Key points: • 3D printers can be used to create reusable culture devices • 3D-printed materials can be sterilized to be used as culture vessels • Standard sterilization already used in the lab can be used with 3D-printed materials
- 17 September 2026
- Published by Springer Nature in Applied Microbiology and Biotechnology
Open AccessDesign and sterilization of 3D-printed glass-bottomed multiwells for cell culture and immunostaining
3D printers are increasingly found in wet laboratories, allowing researchers to print devices for their research needs. To make those devices suitable for cell culture, they should ideally be sterilized following protocols used in cell biology labs. Simultaneously, any sterilization protocol should maintain the mechanical stability of the printed device. Here we have studied two 3D printing materials, Poly-Lactic Acid (PLA) polymers and Acrylonitrile Butadiene Styrene (ABS)-like Photopolymer resins, which are prevalently used in 3D printing. We have subjected 3D-printed specimens of each material to UV light exposure, ethanol immersion and autoclaving, and have verified their mechanical stability at the macro- and nanoscales using tensile testing and nanoindentation. ABS-like resin (0.31 ± 0.07 GPa) remained mechanically viable after UV illumination (1.19 ± 0.02 GPa) or autoclaving (0.36 ± 0.05 GPa), but deteriorated when submerged in ethanol (0.01 ± 0.00 GPa). Nevertheless, sterilized ABS-printed devices probed to be toxic to cells, an effect that could not be prevented when switching to the inert Formlabs Grey resin. On the other hand, PLA specimens (1.22 ± 0.09 GPa) remained mechanically viable after ethanol (1.23 ± 0.15 GPa) and UV (1.21 ± 0.01 GPa) challenge but deteriorated in the autoclave (0.75 ± 0.20 GPa). This effect was prevented when switching to Heat-Treated PLA (HTPLA) polymers (1.07 ± 0.13 GPa). Sterilization of HTPLA-printed devices with a sequence of autoclave, ethanol and UV treatments deemed them suitable for long-term cell culture, as confirmed by measuring cell morphologies and doubling times (21.06 ± 4.66 h). Altogether, we provide here designs for in-house 3D-printing and assembly of glass-bottomed multiwells based on HTPLA and detail optimal sterilization protocols for their use in long-term cell culture and immunostaining. Key points: • 3D printers can be used to create reusable culture devices • 3D-printed materials can be sterilized to be used as culture vessels • Standard sterilization already used in the lab can be used with 3D-printed materials
- Open Access
Characterization of Bioinks Prepared via Gelifying Extracellular Matrix from Decellularized Porcine Myocardia
Since the emergence of 3D bioprinting technology, both synthetic and natural materials have been used to develop bioinks for producing cell-laden cardiac grafts. To this end, extracellular-matrix (ECM)-derived hydrogels can be used to develop scaffolds that closely mimic the complex 3D environments for cell culture. This study presents a novel cardiac bioink based on hydrogels exclusively derived from decellularized porcine myocardium loaded with human-bone-marrow-derived mesenchymal stromal cells. Hence, the hydrogel can be used to develop cell-laden cardiac patches without the need to add other biomaterials or use additional crosslinkers. The scaffold ultrastructure and mechanical properties of the bioink were characterized to optimize its production, specifically focusing on the matrix enzymatic digestion time. The cells were cultured in 3D within the developed hydrogels to assess their response. The results indicate that the hydrogels fostered inter-cell and cell-matrix crosstalk after 1 week of culture. In conclusion, the bioink developed and presented in this study holds great potential for developing cell-laden customized patches for cardiac repair.
Open AccessCharacterization of Bioinks Prepared via Gelifying Extracellular Matrix from Decellularized Porcine Myocardia
Since the emergence of 3D bioprinting technology, both synthetic and natural materials have been used to develop bioinks for producing cell-laden cardiac grafts. To this end, extracellular-matrix (ECM)-derived hydrogels can be used to develop scaffolds that closely mimic the complex 3D environments for cell culture. This study presents a novel cardiac bioink based on hydrogels exclusively derived from decellularized porcine myocardium loaded with human-bone-marrow-derived mesenchymal stromal cells. Hence, the hydrogel can be used to develop cell-laden cardiac patches without the need to add other biomaterials or use additional crosslinkers. The scaffold ultrastructure and mechanical properties of the bioink were characterized to optimize its production, specifically focusing on the matrix enzymatic digestion time. The cells were cultured in 3D within the developed hydrogels to assess their response. The results indicate that the hydrogels fostered inter-cell and cell-matrix crosstalk after 1 week of culture. In conclusion, the bioink developed and presented in this study holds great potential for developing cell-laden customized patches for cardiac repair.
- Open Access
Characterization of 3D Printed Metal-PLA Composite Scaffolds for Biomedical Applications
Three-dimensional printing is revolutionizing the development of scaffolds due to their rapid-prototyping characteristics. One of the most used techniques is fused filament fabrication (FFF), which is fast and compatible with a wide range of polymers, such as PolyLactic Acid (PLA). Mechanical properties of the 3D printed polymeric scaffolds are often weak for certain applications. A potential solution is the development of composite materials. In the present work, metal-PLA composites have been tested as a material for 3D printing scaffolds. Three different materials were tested: copper-filled PLA, bronze-filled PLA, and steel-filled PLA. Disk-shaped samples were printed with linear infill patterns and line spacing of 0.6, 0.7, and 0.8 mm, respectively. The porosity of the samples was measured from cross-sectional images. Biocompatibility was assessed by culturing Human Bone Marrow-Derived Mesenchymal Stromal on the surface of the printed scaffolds. The results showed that, for identical line spacing value, the highest porosity corresponded to bronze-filled material and the lowest one to steel-filled material. Steel-filled PLA polymers showed good cytocompatibility without the need to coat the material with biomolecules. Moreover, human bone marrow-derived mesenchymal stromal cells differentiated towards osteoblasts when cultured on top of the developed scaffolds. Therefore, it can be concluded that steel-filled PLA bioprinted parts are valid scaffolds for bone tissue engineering.
Open AccessCharacterization of 3D Printed Metal-PLA Composite Scaffolds for Biomedical Applications
Three-dimensional printing is revolutionizing the development of scaffolds due to their rapid-prototyping characteristics. One of the most used techniques is fused filament fabrication (FFF), which is fast and compatible with a wide range of polymers, such as PolyLactic Acid (PLA). Mechanical properties of the 3D printed polymeric scaffolds are often weak for certain applications. A potential solution is the development of composite materials. In the present work, metal-PLA composites have been tested as a material for 3D printing scaffolds. Three different materials were tested: copper-filled PLA, bronze-filled PLA, and steel-filled PLA. Disk-shaped samples were printed with linear infill patterns and line spacing of 0.6, 0.7, and 0.8 mm, respectively. The porosity of the samples was measured from cross-sectional images. Biocompatibility was assessed by culturing Human Bone Marrow-Derived Mesenchymal Stromal on the surface of the printed scaffolds. The results showed that, for identical line spacing value, the highest porosity corresponded to bronze-filled material and the lowest one to steel-filled material. Steel-filled PLA polymers showed good cytocompatibility without the need to coat the material with biomolecules. Moreover, human bone marrow-derived mesenchymal stromal cells differentiated towards osteoblasts when cultured on top of the developed scaffolds. Therefore, it can be concluded that steel-filled PLA bioprinted parts are valid scaffolds for bone tissue engineering.
- Open Access
Bioprintable Lung Extracellular Matrix Hydrogel Scaffolds for 3D Culture of Mesenchymal Stromal Cells
Mesenchymal stromal cell (MSC)-based cell therapy in acute respiratory diseases is based on MSC secretion of paracrine factors. Several strategies have proposed to improve this are being explored including pre-conditioning the MSCs prior to administration. We here propose a strategy for improving the therapeutic efficacy of MSCs based on cell preconditioning by growing them in native extracellular matrix (ECM) derived from the lung. To this end, a bioink with tunable stiffness based on decellularized porcine lung ECM hydrogels was developed and characterized. The bioink was suitable for 3D culturing of lung-resident MSCs without the need for additional chemical or physical crosslinking. MSCs showed good viability, and contraction assays showed the existence of cell–matrix interactions in the bioprinted scaffolds. Adhesion capacity and length of the focal adhesions formed were increased for the cells cultured within the lung hydrogel scaffolds. Also, there was more than a 20-fold increase of the expression of the CXCR4 receptor in the 3D-cultured cells compared to the cells cultured in plastic. Secretion of cytokines when cultured in an in vitro model of lung injury showed a decreased secretion of pro-inflammatory mediators for the cells cultured in the 3D scaffolds. Moreover, the morphology of the harvested cells was markedly different with respect to conventionally (2D) cultured MSCs. In conclusion, the developed bioink can be used to bioprint structures aimed to improve preconditioning MSCs for therapeutic purposes.
Open AccessBioprintable Lung Extracellular Matrix Hydrogel Scaffolds for 3D Culture of Mesenchymal Stromal Cells
Mesenchymal stromal cell (MSC)-based cell therapy in acute respiratory diseases is based on MSC secretion of paracrine factors. Several strategies have proposed to improve this are being explored including pre-conditioning the MSCs prior to administration. We here propose a strategy for improving the therapeutic efficacy of MSCs based on cell preconditioning by growing them in native extracellular matrix (ECM) derived from the lung. To this end, a bioink with tunable stiffness based on decellularized porcine lung ECM hydrogels was developed and characterized. The bioink was suitable for 3D culturing of lung-resident MSCs without the need for additional chemical or physical crosslinking. MSCs showed good viability, and contraction assays showed the existence of cell–matrix interactions in the bioprinted scaffolds. Adhesion capacity and length of the focal adhesions formed were increased for the cells cultured within the lung hydrogel scaffolds. Also, there was more than a 20-fold increase of the expression of the CXCR4 receptor in the 3D-cultured cells compared to the cells cultured in plastic. Secretion of cytokines when cultured in an in vitro model of lung injury showed a decreased secretion of pro-inflammatory mediators for the cells cultured in the 3D scaffolds. Moreover, the morphology of the harvested cells was markedly different with respect to conventionally (2D) cultured MSCs. In conclusion, the developed bioink can be used to bioprint structures aimed to improve preconditioning MSCs for therapeutic purposes.
- Open Access
Experimental Setting for Applying Mechanical Stimuli to Study the Endothelial Response of Ex Vivo Vessels under Realistic Pathophysiological Environments
This paper describes the design, construction and testing of an experimental setting, making it possible to study the endothelium under different pathophysiological conditions. This novel experimental approach allows the application of the following stimuli to an ex vivo vessel in a physiological bath: (a) a realistic intravascular pressure waveform defined by the user; (b) shear stress in the endothelial layer since, in addition to the pressure waveform, the flow through the vessel can be independently controlled by the user; (c) conditions of hypo/hyperoxia and hypo/hypercapnia in an intravascular circulating medium. These stimuli can be applied alone or in different combinations to study possible synergistic or antagonistic effects. The setting performance is illustrated by a proof of concept in an ex vivo rabbit aorta. The experimental setting is easy to build by using very low-cost materials widely available. Online Supplement files provide all the technical information (e.g., circuits, codes, 3D printer drivers) following an open-source hardware approach for free replication.
Open AccessExperimental Setting for Applying Mechanical Stimuli to Study the Endothelial Response of Ex Vivo Vessels under Realistic Pathophysiological Environments
This paper describes the design, construction and testing of an experimental setting, making it possible to study the endothelium under different pathophysiological conditions. This novel experimental approach allows the application of the following stimuli to an ex vivo vessel in a physiological bath: (a) a realistic intravascular pressure waveform defined by the user; (b) shear stress in the endothelial layer since, in addition to the pressure waveform, the flow through the vessel can be independently controlled by the user; (c) conditions of hypo/hyperoxia and hypo/hypercapnia in an intravascular circulating medium. These stimuli can be applied alone or in different combinations to study possible synergistic or antagonistic effects. The setting performance is illustrated by a proof of concept in an ex vivo rabbit aorta. The experimental setting is easy to build by using very low-cost materials widely available. Online Supplement files provide all the technical information (e.g., circuits, codes, 3D printer drivers) following an open-source hardware approach for free replication.
- 1 March 2020
- Published by SAGE Publications in Tissue Engineering Part A
- Vol. 26 (5-6) , 358-370
Silk-Reinforced Collagen Hydrogels with Raised Multiscale Stiffness for Mesenchymal Cells 3D Culture
Type I collagen hydrogels are of high interest in tissue engineering. With the evolution of 3D bioprinting technologies, a high number of collagen-based scaffolds have been reported for the development of 3D cell cultures. A recent proposal was to mix collagen with silk fibroin derived from Bombyx Mori silkworm. Nevertheless, due to the difficulties in the preparation and the characteristics of the protein, several problems like phase separation and collagen denaturation appears during the procedure. Therefore, the common solution is to diminish the concentration of collagen although in that way the most biologically relevant component is reduced. In the present work, we present a new, simple and effective method to develop a collagen-silk hybrid hydrogel with high collagen concentration and with increased stiffness approaching that of natural tissues, which could be of high interest for the development of cardiac patches for myocardial regeneration and for preconditioning of mesenchymal stem cells to improve their therapeutic potential. Sericin in the silk was preserved by using a physical solubilizing procedure which results in a preserved fibrous structure of type I collagen, as shown by ultrastructural imaging. The macro- and micromechanical properties of the hybrid hydrogels measured by tensile stretch and Atomic Force Microscopy respectively, showed a more than two-fold stiffening as compared with collagen-only hydrogels. Rheological measurements showed improved printability properties for the developed biomaterial. The suitability of the hydrogels for 3D cell culture was assessed by 3D bioprinting bone marrow-derived mesenchymal stem cells cultured within the scaffolds. The result was a biomaterial with improved printability characteristics that better resembled the mechanical properties of natural soft tissues while preserving biocompatibility owing to the high concentration of collagen.
- 1 March 2020
- Published by SAGE Publications in Tissue Engineering Part A
- Vol. 26 (5-6) , 358-370
Silk-Reinforced Collagen Hydrogels with Raised Multiscale Stiffness for Mesenchymal Cells 3D Culture
Type I collagen hydrogels are of high interest in tissue engineering. With the evolution of 3D bioprinting technologies, a high number of collagen-based scaffolds have been reported for the development of 3D cell cultures. A recent proposal was to mix collagen with silk fibroin derived from Bombyx Mori silkworm. Nevertheless, due to the difficulties in the preparation and the characteristics of the protein, several problems like phase separation and collagen denaturation appears during the procedure. Therefore, the common solution is to diminish the concentration of collagen although in that way the most biologically relevant component is reduced. In the present work, we present a new, simple and effective method to develop a collagen-silk hybrid hydrogel with high collagen concentration and with increased stiffness approaching that of natural tissues, which could be of high interest for the development of cardiac patches for myocardial regeneration and for preconditioning of mesenchymal stem cells to improve their therapeutic potential. Sericin in the silk was preserved by using a physical solubilizing procedure which results in a preserved fibrous structure of type I collagen, as shown by ultrastructural imaging. The macro- and micromechanical properties of the hybrid hydrogels measured by tensile stretch and Atomic Force Microscopy respectively, showed a more than two-fold stiffening as compared with collagen-only hydrogels. Rheological measurements showed improved printability properties for the developed biomaterial. The suitability of the hydrogels for 3D cell culture was assessed by 3D bioprinting bone marrow-derived mesenchymal stem cells cultured within the scaffolds. The result was a biomaterial with improved printability characteristics that better resembled the mechanical properties of natural soft tissues while preserving biocompatibility owing to the high concentration of collagen.