JLJiahao Liu

Jiahao Liu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jiahao Liu has a total of 70 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A New Target Domain One-Class Learning Bearing Fault Detection Framework

    by Chang Liu, Ziqian He, Qian Xiang, Chen Li, Xiben Jiao, Wei He, Le Jin, Yuanchao Yu, Ye Liu, Jiahao Liu, et al.

    Bearing fault detection is essential for machinery health management. An issue of existing work is that the network trained with a publicly available dataset (source domain) often has a large accuracy drop when applied to a target machine (target domain), since the source domain and target domain originate from different machines, and thus exhibit significant differences in data distribution. Besides, in real industrial processes, collecting large amounts of fault data from the target machine is unrealistic. To address the above issues, a target domain one-class learning bearing fault detection framework (TDOCL-BFDF) is proposed in this article inspired by the distribution discrepancy between the normal and the fault data. Firstly, a new three-stage training-initializing scheme, which fully utilizes data from source and target domains, is designed for the TDOCL-BFDF to extract features from the target normal data and increase the distribution discrepancy between the normal and the fault data. Secondly, a Gaussian fault detector (GFD)—serving as a critical performance-enhancing module of the TDOCL-BFDF model is proposed to mitigate the scale imbalance across the dimensions of latent features. The proposed framework is evaluated using four bearing datasets (three public and one in-house dataset) and achieves an accuracy of 0.990-1.0 in all the fault detection tasks. The results show that the TDOCL-BFDF outperforms other state-of-the-art methods and manifests the great potential of the proposed TDOCL-BFDF for real industrial application scenarios.

  • A High-Accuracy and Ultra-Energy-Efficient Cardiac Arrhythmia Classification Processor for Wearable Intelligent ECG Monitoring

    by Jiahao Liu, Ziyi Xie, Xiao Liu, Xu Wang, Jianbiao Xiao, Chaozheng Guo, Jiajing Fan, Qingsong Liu, Zhen Zhu, Sixu Li, et al.

    Wearable intelligent electrocardiography (ECG) sensors with integrated cardiac arrhythmia classification processors have been used to detect and classify arrhythmia, alerting users to potential cardiac diseases. While state-of-the-art arrhythmia classification processors employ neural networks (NNs), the high computational complexity of NNs results in significant energy consumption, limiting the model size and classification performance of NNs. Additionally, inter-patient variation in ECG can lead to accuracy degradation when applying a trained NN to patients whose ECG features differ from those in the training dataset. In this work, we propose an ultra-energy-efficient cardiac arrhythmia classification processor incorporating three key technologies: 1) heartbeat difference-based classification to improve accuracy under inter-patient variation and reduce energy consumption; 2) event-driven NN computation with shared feature extraction to reduce energy consumption; and 3) an adaptive NN wake-up technique to reduce energy consumption while maintaining accuracy. The design was fabricated using 55-nm CMOS process technology and evaluated using the MIT-BIH arrhythmia dataset. For arrhythmia classification, it demonstrates an energy consumption of $0.09~{\mu }$ J per classification with 98.7%/96.6% accuracy for intra-patient and inter-patient testing, respectively.


  • A High Accuracy and Ultra-Energy-Efficient Zero-Shot-Retraining Seizure Detection Processor

    by Jiahao Liu, Xiao Liu, Xu Wang, Ziyi Xie, Chaozheng Guo, Zirui Zhong, Jiajing Fan, Hui Qiu, Yiming Xu, Huajing Qin, et al.

    Recently, wearable devices integrating seizure detection processors have been developed to detect seizures in real time for alerting, recording, or in-device treatment purposes. High accuracy and low energy consumption are paramount for seizure detection processors. Many existing seizure detection processors are able to achieve high accuracy when large amounts of seizure data from the test patient is available for the training, which requires the test patient to undergo time-consuming and costly hospitalization due to the low occurrence of seizure data and therefore is impractical. This work proposes a high-accuracy and ultra-energy-efficient zero-shot-retraining seizure detection processor that requires no seizure data from the test patient for retraining. Two novel techniques have been proposed to improve the accuracy and reduce energy consumption, including a hybrid-feature-driven adaptive processing architecture with on-chip learning for improving the accuracy against inter-patient variation and reduce the classification energy consumption and a learning-based adaptive channel selection technique to identify the redundant electroencephalogram (EEG) channels for further energy saving while maintaining high accuracy. The proposed seizure detection processor has been implemented and fabricated in 55-nm CMOS technology. It demonstrates high sensitivity (i.e., 100% event-based sensitivity) and specificity (i.e., 94%) with extremely low energy consumption (i.e., $0.07~\mu $ J/classification and $0.1~\mu $ J/learning) while requiring no seizure data from the test patient for retraining, outperforming the state-of-the-art designs.


  • A High Accuracy and Real-Time sEMG-Based Hand Gesture Classifier Using LDA-Based Template Matching With Adaptive Majority Vote and Online Data Augmentation

    by Haiting Li, Yushan Li, Jiexun Luo, Xiben Jiao, Jiahao Liu, Liang Zhou, Liang Chang, Jun Zhou

    Surface electromyography (sEMG)-based gesture classification is promising in many emerging applications such as prosthetic control and Augmented Reality (AR) / Virtual Reality (VR). While many existing sEMG-based hand gesture classifiers achieve high intra-session accuracy, they show very low inter-session and inter-subject accuracy which are more important in practical use. Another issue of the existing works is the usage of deep neural networks increases the accuracy but also brings up the complexity, making real-time classification difficult especially on embedded systems. In this work, an sEMG-based hand gesture classifier with high inter-session, inter-subject accuracy and real-time performance is proposed. A linear discriminant analysis (LDA)-based template matching method is proposed to improve the inter-session and inter-subject accuracy while maintaining low complexity. An adaptive window-size majority vote method and a calibration-oriented online data augmentation method are proposed to further improve the accuracy. The proposed classifier has been implemented on both GPU and FPGA-based embedded system demonstrating real-time performance. Compared to the state-of-the-art works, the proposed classifier achieves higher inter-session and inter-subject accuracy of 78.0% and 78.9% on Ninapro DB6 (95.2% and 96.6% on CapgMyo DB-b) with shorter classification time of 6.5ms on Ninapro DB6 (4.9ms on CapgMyo DB-b).


  • An Ultra-Low Power Reconfigurable Biomedical AI Processor With Adaptive Learning for Versatile Wearable Intelligent Health Monitoring

    by Jiahao Liu, Jiajing Fan, Zirui Zhong, Hui Qiu, Jianbiao Xiao, Yong Zhou, Zhen Zhu, Guanghai Dai, Ning Wang, Qingsong Liu, et al.

    Wearable intelligent health monitoring devices with on-device biomedical AI processor can be used to detect the abnormity in users' biomedical signals (e.g., ECG arrythmia classification, EEG-based seizure detection). This requires ultra-low power and reconfigurable biomedical AI processor to support battery-supplied wearable devices and versatile intelligent health monitoring applications while achieving high classification accuracy. However, existing designs have issues in meeting one or more of the above requirements. In this work, a reconfigurable biomedical AI processor (named BioAIP) is proposed, mainly featuring: 1) a reconfigurable biomedical AI processing architecture to support versatile biomedical AI processing. 2) an event-driven biomedical AI processing architecture with approximate data compression to reduce the power consumption. 3) an AI-based adaptive-learning architecture to address patient-to-patient variation and improve the classification accuracy. The design has been implemented and fabricated using a 65nm CMOS process technology. It has been demonstrated with three typical biomedical AI applications, including ECG arrythmia classification, EEG-based seizure detection and EMG-based hand gesture recognition. Compared with the state-of-the-art designs optimized for single biomedical AI tasks, the BioAIP achieves the lowest energy per classification among the designs with similar accuracy, while supporting various biomedical AI tasks.


  • Transposable 9T-SRAM Computation-In-Memory for on-Chip Learning With Probability-Based Single-Slope SAR Hybrid ADC for Edge Devices

    by Yong-Jun Jo, Xin Zhang, Jiahao Liu, Jun Zhou, Yuanjin Zheng, Tony Tae-Hyoung Kim

    This work proposes a two-way transposable SRAM computation-in-memory (CIM) macro for inference and training in convolutional neural networks (CNNs). A novel 9T SRAM bitcell conducts local two-way computing without shared processing units, achieving higher processing throughput from every bit-cell operating in one CIM cycle. This work also proposes a probabilitybased single-slope (SS) and successive approximation (SAR) hybrid analog-to-digital converter (ADC) for energy efficiency improvement by utilizing the probability density function of multiply-and-accumulation (MAC). The proposed ADC also supports the ReLU-based zero skip function without additional circuitry. The prototype was fabricated in 180nm CMOS technology and achieved an energy efficiency of 6.61 (1.65) TOPS/W for inference (training).


  • Open Access

    A High Accuracy & Ultra-Low Power ECG-Derived Respiration Estimation Processor for Wearable Respiration Monitoring Sensor

    by Jiajing Fan, Siqi Yang, Jiahao Liu, Zhen Zhu, Jianbiao Xiao, Liang Chang, Shuisheng Lin, Jun Zhou

    The respiratory rate is widely used for evaluating a person’s health condition. Compared to other invasive and expensive methods, the ECG-derived respiration estimation is a more comfortable and affordable method to obtain the respiration rate. However, the existing ECG-derived respiration estimation methods suffer from low accuracy or high computational complexity. In this work, a high accuracy and ultra-low power ECG-derived respiration estimation processor has been proposed. Several techniques have been proposed to improve the accuracy and reduce the computational complexity (and thus power consumption), including QRS detection using refractory period refreshing and adaptive threshold EDR estimation. Implemented and fabricated using a 55 nm processing technology, the proposed processor achieves a low EDR estimation error of 0.73 on CEBS database and 1.2 on MIT-BIH Polysomnographic Database while demonstrating a record-low power consumption (354 nW) for the respiration monitoring, outperforming the existing designs. The proposed processor can be integrated in a wearable sensor for ultra-low power and high accuracy respiration monitoring.


  • An Ultra-Energy-Efficient and High Accuracy ECG Classification Processor With SNN Inference Assisted by On-Chip ANN Learning

    by Ruixin Mao, Sixu Li, Zhaomin Zhang, Zihan Xia, Jianbiao Xiao, Zixuan Zhu, Jiahao Liu, Weiwei Shan, Liang Chang, Jun Zhou

    The ECG classification processor is a key component in wearable intelligent ECG monitoring devices which monitor the ECG signals in real time and detect the abnormality automatically. The state-of-the-art ECG classification processors for wearable intelligent ECG monitoring devices are faced with two challenges, including ultra-low energy consumption demand and high classification accuracy demand against patient-to-patient variability. To address the above two challenges, in this work, an ultra-energy-efficient ECG classification processor with high classification accuracy is proposed. Several design techniques have been proposed, including a reconfigurable SNN/ANN inference architecture for reducing energy consumption while maintaining classification accuracy, a reconfigurable on-chip learning architecture for improving the classification accuracy against patent-to-patient variability, and a dual-purpose binary encoding scheme of ECG heartbeats for further reducing the energy consumption. Fabricated with a 28nm CMOS technology, the proposed design consumes extremely low classification energy (0.3μJ) while achieving high classification accuracy (97.36%) against patient-to-patient variability, outperforming several state-of-the-art designs.