SRSamuel W. Remedios

Samuel W. Remedios

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Samuel W. Remedios has a total of 83 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    MSRepaint: Multiple Sclerosis Repaint with conditional denoising diffusion implicit model for bidirectional lesion filling and synthesis

    by Jinwei Zhang, Lianrui Zuo, Yihao Liu, Hang Zhang, Samuel W. Remedios, Bennett A. Landman, Peter A. Calabresi, Shiv Saidha, Scott D. Newsome, Dzung L. Pham, et al.

  • Contrast-Invariant Reference-Based Slice Thickness Estimation in MRI via Spectral Matching

    by Samuel W. Remedios, Shuwen Wei, Aaron Carass, Jerry L. Prince, Blake E. Dewey

  • Open Access

    ECLARE: efficient cross-planar learning for anisotropic resolution enhancement

    by Samuel W. Remedios, Shuwen Wei, Shuo Han, Jinwei Zhang, Aaron Carass, Kurt G. Schilling, Dzung L. Pham, Jerry L. Prince, Blake E. Dewey

    PurposeIn clinical imaging, magnetic resonance (MR) image volumes are often acquired as stacks of 2D slices with decreased scan times, improved signal-to-noise ratio, and image contrasts unique to 2D MR pulse sequences. Although this is sufficient for clinical evaluation, automated algorithms designed for 3D analysis perform poorly on multislice 2D MR volumes, especially those with thick slices and gaps between slices. Superresolution (SR) methods aim to address this problem, but previous methods do not address all of the following: slice profile shape estimation, slice gap, domain shift, and noninteger or arbitrary upsampling factors.ApproachWe propose ECLARE (Efficient Cross-planar Learning for Anisotropic Resolution Enhancement), a self-SR method that addresses each of these factors. ECLARE uses a slice profile estimated from the multislice 2D MR volume, trains a network to learn the mapping from low-resolution to high-resolution in-plane patches from the same volume, performs SR with antialiasing, and respects the image FOV during resampling. We compared ECLARE with cubic B-spline interpolation, SMORE, and other contemporary SR methods. We used realistic and representative simulations on human head MR volumes so that quantitative performance against ground truth can be computed. Specifically, healthy T1-w and people with MS T2-w FLAIR datasets were used for evaluations. We used the peak signal-to-noise ratio and structural similarity index measure as signal recovery metrics. We additionally used two independent brain parcellation algorithms, SLANT and SynthSeg, to compute the consistency Dice similarity coefficient and the R2 coefficient of determination, respectively, as comparison metrics.ResultsFor images with up to 5 mm of slice thickness and up to 1.5 mm of gap, ECLARE achieves greater mean PSNR and SSIM compared with other methods. In representative regions of interest, such as the ventricles, caudate, cerebral white matter, and cerebellar white matter, ECLARE performs comparably or better than other approaches. These trends are similar for both investigated datasets.ConclusionsThe use of slice profile estimation, FOV-aware resampling, and self-SR allowed ECLARE to robustly superresolve anisotropic images without the need for external training data. Future work will investigate the utility of ECLARE on other organs, species, modalities, and resolutions. Our code is open-source and available at https://www.github.com/sremedios/eclare.


  • Top Cited Papers
    Open Access

    UNISELF: A unified network with instance normalization and self-ensembled lesion fusion for multiple sclerosis lesion segmentation

    by Jinwei Zhang, Lianrui Zuo, Blake E. Dewey, Samuel W. Remedios, Yihao Liu, Savannah P. Hays, Dzung L. Pham, Ellen M. Mowry, Scott D. Newsome, Peter A. Calabresi, et al.


  • Open Access

    Likelihood-Separable Diffusion Inference for Multi-Image MRI Super-Resolution

    by Samuel W. Remedios, Zhangxing Bian, Shuwen Wei, Aaron Carass, Jerry L. Prince, Blake E. Dewey

    Diffusion models are the current state-of-the-art for solving inverse problems in imaging. Their impressive generative capability allows them to approximate sampling from a prior distribution, which alongside a known likelihood function permits posterior sampling without retraining the model. While recent methods have made strides in advancing the accuracy of posterior sampling, the majority focuses on single-image inverse problems. However, for modalities such as magnetic resonance imaging (MRI), it is common to acquire multiple complementary measurements, each low-resolution along a different axis. In this work, we generalize common diffusion-based inverse single-image problem solvers for multi-image super-resolution (MISR) MRI. We show that the DPS likelihood correction allows an exactly-separable gradient decomposition across independently acquired measurements, enabling MISR without constructing a joint operator, modifying the diffusion model, or increasing network function evaluations. We derive MISR versions of DPS, DMAP, DPPS, and diffusion-based PnP/ADMM, and demonstrate substantial gains over SISR across $4\times/8\times/16\times$ anisotropic degradations. Our results achieve state-of-the-art super-resolution of anisotropic MRI volumes and, critically, enable reconstruction of near-isotropic anatomy from routine 2D multi-slice acquisitions, which are otherwise highly degraded in orthogonal views.

    • 1 January 2026
      • Vol. 301, 604-614
    Open Access

    An Unsupervised Approach for Artifact Severity Scoring in Multi-Contrast MR Images

    by Savannah P. Hays, Lianrui Zuo, Blake E. Dewey, Samuel W. Remedios, Jinwei Zhang, Ellen M. Mowry, Scott D. Newsome, Aaron Carass, Jerry L. Prince

    Quality assurance (QA) in magnetic resonance (MR) imaging is critical but remains a challenging and time-intensive process, particularly when working with large-scale, multi-site imaging datasets. Manual QA methods are subjective, prone to inter-rater variability, and impractical for high-throughput workflows. Existing automated QA methods often lack generalizability to diverse datasets or fail to provide interpretable insights into the causes of poor image quality. To address these limitations, we introduce an unsupervised and interpretable QA framework for multi-contrast MR images that quantifies artifact severity. By assigning a numerical score to each image, our method enables objective, consistent evaluation of image quality and highlights specific levels of artifact presence that can impair downstream analysis. Our framework employs an unsupervised contrastive learning approach, leveraging simulated artifact transformations, including random bias, noise, anisotropy, and ghosting, to train the model without requiring manual labels or preprocessing. A margin-based contrastive loss further enables differentiation between varying levels of artifact severity. We validate our framework using simulated artifacts on a public dataset and real artifacts on a private clinical dataset, demonstrating its robustness and generalizability for automatic MR image QA. By efficiently evaluating image quality and identifying artifacts prior to data processing, our approach streamlines QA workflows and enhances the reliability of subsequent analyses in both research and clinical settings.

  • Exploring the Feasibility of Zero-Shot Super-Resolution in Preclinical Imaging

    by Omar A. M. Gharib, Samuel W. Remedios, Blake E. Dewey, Jerry L. Prince, Aaron Carass

    Preclinical imaging studies are vital to the research, development, and evaluation of new medical therapies. Images acquired during these studies often have high in-plane resolution but low through-plane resolution, resulting in highly anisotropic volumes that hamper downstream volumetric analysis. Additionally, since there are no image acquisition standards across studies, training data for conventional supervised super-resolution (SR) methods is limited. In this work, we compare two SR methods that do not require additional training data. The first is ECLARE, a self-SR approach that creates its own training data from in-plane patches drawn from the anisotropic volume. The second is Biplanar Denoising diffusion null space model (DDNM) Averaging (BiDA), a proposed method leveraging two independently pre-trained denoising diffusion probabilistic models and the DDNM posterior sampling technique. We evaluate both methods first on rat data at two scale factors (\(2.5\times \) and \(5\times \)) and compare signal recovery and downstream task performance. We further evaluate these methods on a different species (mice) to measure their generalizability. Both methods experimentally resulted in good signal recovery performance, but only the images super-resolved by BiDA were accurately skullstripped downstream. Although both methods performed well on the in-domain rat data, BiDA did not fully generalize to the out-of-domain mouse data.


  • Unsupervised OCT Image Interpolation Using Deformable Registration and generative models

    by Shuwen Wei, Samuel W. Remedios, Zhangxing Bian, Shimeng Wang, Junyu Chen, Yihao Liu, Bruno Jedynak, Tin Y. A. Liu, Shiv Saidha, Peter A. Calabresi, et al.

    Optical coherence tomography (OCT) images are often acquired as highly anisotropic volumes, where the scanning step is dense along the fast axis but sparse along the slow axis. This affects image analysis, such as image registration for longitudinal alignment. To create more isotropic volumes, bicubic interpolation can be used along the slow axis, but it generally produces blurry features. Registration-based interpolation can reduce blurriness, but often fails to generate realistic OCT images. Deep generative models can sample realistic images, but lack the structural consistency constraints required for interpolation. In this paper, we propose an unsupervised image interpolation method that combines registration-based interpolation with a deep generative model to overcome their individual limitations and improve the structural accuracy and realism of interpolated OCT images. We compare the proposed method with both bicubic and registration-based interpolation on real OCT datasets, and show that it achieves the best interpolation performance.

  • Cycle-Consistent Zero-Shot Through-Plane Super-Resolution for Anisotropic Head MRI

    by Samuel W. Remedios, Shuwen Wei, Aaron Carass, Blake E. Dewey, Jerry L. Prince

    Magnetic resonance (MR) images are often acquired as aniso-tropic volumes in clinical settings. Such volumes have a worse through-plane resolution than in-plane resolution, hampering results in many processing pipelines that expect isotropic resolutions. Super-resolution (SR) is a promising methodology to address this problem, but there is concern whether the estimated high-resolution (HR) image suffers from egregious hallucinations, especially with deep learning methods that produce aesthetically pleasing results. One approach to restrict the impact of hallucinations is to guarantee that the estimated HR image is exactly cycle-consistent with the low-resolution observation. The denoising diffusion null space model (DDNM) achieves this through a range null space decomposition, but the specific design of the forward map is left to the application. In this work, we analyze the forward problem in 2D MR acquisition and construct an appropriate linear map A. We train a denoising diffusion probabilistic model on T\(_1\)-weighted (T\(_1\)-w) head MR images from multiple datasets and implement DDNM using A for the SR task. We show that the approach yields exact cycle-consistent solutions that are also realistic. We evaluated the approach in a wide variety of T\(_1\)-w MR datasets, including withheld subjects from training sites and two sites outside of the training domain. We achieve excellent qualitative and quantitative results according to both distortion and perceptual metrics.

  • Open Access

    Influence of early through late fusion on pancreas segmentation from imperfectly registered multimodal magnetic resonance imaging

    by Lucas W. Remedios, Han Liu, Samuel W. Remedios, Lianrui Zuo, Adam M. Saunders, Shunxing Bao, Yuankai Huo, Alvin C. Powers, John Virostko, Bennett A. Landman

    PurposeCombining different types of medical imaging data, through multimodal fusion, promises better segmentation of anatomical structures, such as the pancreas. Strategic implementation of multimodal fusion could improve our ability to study diseases such as diabetes. However, where to perform fusion in deep learning models is still an open question. It is unclear if there is a single best location to fuse information when analyzing pairs of imperfectly aligned images or if the optimal fusion location depends on the specific model being used. Two main challenges when using multiple imaging modalities to study the pancreas are (1) the pancreas and surrounding abdominal anatomy have a deformable structure, making it difficult to consistently align the images and (2) breathing by the individual during image collection further complicates the alignment between multimodal images. Even after using state-of-the-art deformable image registration techniques, specifically designed to align abdominal images, multimodal images of the abdomen are often not perfectly aligned. We examine how the choice of different fusion points, ranging from early in the image processing pipeline to later stages, impacts the segmentation of the pancreas on imperfectly registered multimodal magnetic resonance (MR) images.ApproachOur dataset consists of 353 pairs of T2-weighted (T2w) and T1-weighted (T1w) abdominal MR images from 163 subjects with accompanying pancreas segmentation labels drawn mainly based on the T2w images. Because the T2w images were acquired in an interleaved manner across two breath holds and the T1w images on one breath hold, there were three different breath holds impacting the alignment of each pair of images. We used deeds, a state-of-the-art deformable abdominal image registration method to align the image pairs. Then, we trained a collection of basic UNets with different fusion points, spanning from early to late layers in the model, to assess how early through late fusion influenced segmentation performance on imperfectly aligned images. To investigate whether performance differences on key fusion points are generalized to other architectures, we expanded our experiments to nnUNet.ResultsThe single-modality T2w baseline using a basic UNet model had a median Dice score of 0.766, whereas the same baseline on the nnUNet model achieved 0.824. For each fusion approach, we analyzed the differences in performance with Dice residuals, by subtracting the baseline score from the fusion score for each datapoint. For the basic UNet, the best fusion approach was from early/mid fusion and occurred in the middle of the encoder with a median Dice residual of +0.012 compared with the baseline. For the nnUNet, the best fusion approach was early fusion through naïve image concatenation before the model, with a median Dice residual of +0.004 compared with the baseline. After Bonferroni correction, the distributions of the Dice scores for these best fusion approaches were found to be statistically significant (p<0.05) via the paired Wilcoxon signed-rank test against the baseline.ConclusionsFusion in specific blocks can improve performance, but the best blocks for fusion are model-specific, and the gains are small. In imperfectly registered datasets, fusion is a nuanced problem, with the art of design remaining vital for uncovering potential insights. Future innovation is needed to better address fusion in cases of imperfect alignment of abdominal image pairs. The code associated with this project is available here https://github.com/MASILab/influence_of_fusion_on_pancreas_segmentation.