Winarto Winarto
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Winarto Winarto has a total of 83 co-authors. Here are the top co-authors by number of shared publications:
- Ario Sunar Baskoro
Department of Mechanical Engineering, Faculty of Engineering, Universitas Indonesia, Depok, Indonesia
5 shared publications Herry Oktadinata
Universitas Indonesia
5 shared publicationsGandjar Kiswanto
Universitas Indonesia
4 shared publications- Nofrijon Sofyan
Department of Metallurgical and Materials Engineering, Faculty of Engineering, Universitas Indonesia, Depok 16424, Indonesia
4 shared publications Ario Sunar Baskoro
Universitas Indonesia
2 shared publicationsDedi Priadi
2 shared publications
Latest Publications
- 25 June 2026
- Published by Trans Tech Publications, Ltd. in Materials Science Forum
- Vol. 1195, 23-32
Mechanical Properties and Microstructural Analysis of AISI 304 and Duplex 2550 Welded by GTAW and SMAW Techniques
This study investigates the mechanical properties and microstructure of dissimilar welds between AISI 304 and Duplex 2550 using GTAW and SMAW processes with filler metals ER309 and E309-16. The weld joint exhibited a tensile strength of 508.7 MPa, lower than AISI 304's minimum of 515 MPa and Duplex 2550's 760 MPa, primarily due to the heat-affected zone (HAZ). Significant differences in hardness were observed, with the weld metal averaging 194.8 HV, compared to 181.9 HV and 229.9 HV for the HAZ of AISI 304 and Duplex 2550, respectively. Charpy tests indicated reduced impact energy and absorption in the weld metal and HAZ compared to the base metal. XRD analysis revealed the formation of intermetallic phases, including chi (χ), sigma (σ), and carbides in the weld metal, which compromised mechanical properties and corrosion resistance.
- 25 June 2026
- Published by Trans Tech Publications, Ltd. in Materials Science Forum
- Vol. 1195, 23-32
Mechanical Properties and Microstructural Analysis of AISI 304 and Duplex 2550 Welded by GTAW and SMAW Techniques
This study investigates the mechanical properties and microstructure of dissimilar welds between AISI 304 and Duplex 2550 using GTAW and SMAW processes with filler metals ER309 and E309-16. The weld joint exhibited a tensile strength of 508.7 MPa, lower than AISI 304's minimum of 515 MPa and Duplex 2550's 760 MPa, primarily due to the heat-affected zone (HAZ). Significant differences in hardness were observed, with the weld metal averaging 194.8 HV, compared to 181.9 HV and 229.9 HV for the HAZ of AISI 304 and Duplex 2550, respectively. Charpy tests indicated reduced impact energy and absorption in the weld metal and HAZ compared to the base metal. XRD analysis revealed the formation of intermetallic phases, including chi (χ), sigma (σ), and carbides in the weld metal, which compromised mechanical properties and corrosion resistance.
- 22 June 2026
- Published by Trans Tech Publications, Ltd. in Key Engineering Materials
- Vol. 1058, 111-125
Preliminary Study of the Wire Filler Selection of Gas Metal Arc Welding-Additive Manufacturing (GMAW-AM) on Aluminum Alloys
Wire arc additive manufacturing (WAAM) with the Gas Metal Arc Welding (GMAW) method has a high deposit rate. It is more efficient and capable of producing small and medium-sized components economically. In addition to parameter selection, the WAAM process is also influenced by the choice of the filler wire types to determine the process stability, quality of the results, and desired dimensions. Filler wire selection in the WAAM process is important because it uses aluminum alloys commonly used in ER4043 and ER5356 fillers. This research method employs experiments using ER4043 and ER5356 filler wires and AA6061 substrate to determine suitable parameters for a stable WAAM process. It then measures bead dimensions, surface roughness, and tests for damage-free operation using dye penetrant. The experimental results obtained using the ER4043 wire with a diameter of 1 mm, a current of 80 A, and a voltage of 14 V were unstable. In contrast, using the ER5356 filler, the stable experimental process. The arc length affects the bead geometry. Some of the impacts that occur due to the arc length are defects such as porosity, protrusions, and collapse areas in the final bead area, as well as the absence of fusion defects on the bead edges.
- 22 June 2026
- Published by Trans Tech Publications, Ltd. in Key Engineering Materials
- Vol. 1058, 111-125
Preliminary Study of the Wire Filler Selection of Gas Metal Arc Welding-Additive Manufacturing (GMAW-AM) on Aluminum Alloys
Wire arc additive manufacturing (WAAM) with the Gas Metal Arc Welding (GMAW) method has a high deposit rate. It is more efficient and capable of producing small and medium-sized components economically. In addition to parameter selection, the WAAM process is also influenced by the choice of the filler wire types to determine the process stability, quality of the results, and desired dimensions. Filler wire selection in the WAAM process is important because it uses aluminum alloys commonly used in ER4043 and ER5356 fillers. This research method employs experiments using ER4043 and ER5356 filler wires and AA6061 substrate to determine suitable parameters for a stable WAAM process. It then measures bead dimensions, surface roughness, and tests for damage-free operation using dye penetrant. The experimental results obtained using the ER4043 wire with a diameter of 1 mm, a current of 80 A, and a voltage of 14 V were unstable. In contrast, using the ER5356 filler, the stable experimental process. The arc length affects the bead geometry. Some of the impacts that occur due to the arc length are defects such as porosity, protrusions, and collapse areas in the final bead area, as well as the absence of fusion defects on the bead edges.
- Open Access
- 1 January 2026
- Published by Wiley in Advances in Materials Science and Engineering
- Vol. 2026 (1)
Subcritical Thermal Degradation of SA210 Grade A1 Ferritic–Pearlitic Steel: Microstructural Evolution, Hardness Loss, and Strength Reduction
Ferritic–pearlitic boiler tube steel undergoes progressive microstructural degradation during subcritical overheating, impairing mechanical integrity well before severe wall thinning occurs. To quantify this degradation trajectory, we established a stage‐resolved framework linking subcritical thermal exposure, microstructural degradation, Vickers hardness loss, and tensile strength reduction in SA210 Grade A1 boiler tube steel. Isothermal annealing was conducted at 600, 660, and 720°C. Holding times reached up to 100 h at 600°C and 660°C, and up to 30 h at 720°C, producing degradation states ranging from the intact as‐received condition to an advanced carbide‐degraded morphology, classified under the Toft–Marsden six‐stage scheme. Higher temperature severely compressed the degradation timeline. Reaching Stage D required 100 h at 600°C, 30 h at 660°C, and merely 1 h at 720°C. Image analysis revealed a reduction in the pearlite‐derived dark constituent area fraction from 25.44% ± 2.27% in the as‐received condition to 11.63% ± 1.55% at Stage F, tracking the dissolution and spheroidization of continuous pearlite colonies. Ferrite grain coarsening remained minor, with the ASTM grain size number shifting from G = 9.49 ± 0.04 to G = 9.16 ± 0.03. Mechanically, median hardness fell from 167.9 HV to 121.8 HV, corresponding to a 27.4% loss, alongside a 29.55% drop in mean UTS (508.02 ± 9.71 MPa to 357.92 ± 14.61 MPa). A temperature–logarithmic time regression modeled the hardness loss with R 2 = 0.965, indicating that a 60°C thermal increment produced a softening effect equivalent to a tenfold increase in dwelling time. Relative UTS loss scaled proportionally with relative hardness loss, following ΔUTS (%) = 0.989Δ H (%) − 0.194, with R 2 = 0.962. When integrated with metallographic staging and thermal history, hardness testing serves as a robust quantitative proxy for nondestructive strength assessment in degraded boiler tubes.
- 1 January 2026
- Published by Wiley in Advances in Materials Science and Engineering
- Vol. 2026 (1)
Open AccessSubcritical Thermal Degradation of SA210 Grade A1 Ferritic–Pearlitic Steel: Microstructural Evolution, Hardness Loss, and Strength Reduction
Ferritic–pearlitic boiler tube steel undergoes progressive microstructural degradation during subcritical overheating, impairing mechanical integrity well before severe wall thinning occurs. To quantify this degradation trajectory, we established a stage‐resolved framework linking subcritical thermal exposure, microstructural degradation, Vickers hardness loss, and tensile strength reduction in SA210 Grade A1 boiler tube steel. Isothermal annealing was conducted at 600, 660, and 720°C. Holding times reached up to 100 h at 600°C and 660°C, and up to 30 h at 720°C, producing degradation states ranging from the intact as‐received condition to an advanced carbide‐degraded morphology, classified under the Toft–Marsden six‐stage scheme. Higher temperature severely compressed the degradation timeline. Reaching Stage D required 100 h at 600°C, 30 h at 660°C, and merely 1 h at 720°C. Image analysis revealed a reduction in the pearlite‐derived dark constituent area fraction from 25.44% ± 2.27% in the as‐received condition to 11.63% ± 1.55% at Stage F, tracking the dissolution and spheroidization of continuous pearlite colonies. Ferrite grain coarsening remained minor, with the ASTM grain size number shifting from G = 9.49 ± 0.04 to G = 9.16 ± 0.03. Mechanically, median hardness fell from 167.9 HV to 121.8 HV, corresponding to a 27.4% loss, alongside a 29.55% drop in mean UTS (508.02 ± 9.71 MPa to 357.92 ± 14.61 MPa). A temperature–logarithmic time regression modeled the hardness loss with R 2 = 0.965, indicating that a 60°C thermal increment produced a softening effect equivalent to a tenfold increase in dwelling time. Relative UTS loss scaled proportionally with relative hardness loss, following ΔUTS (%) = 0.989Δ H (%) − 0.194, with R 2 = 0.962. When integrated with metallographic staging and thermal history, hardness testing serves as a robust quantitative proxy for nondestructive strength assessment in degraded boiler tubes.
- 19 October 2025
- Published by Springer Nature
- p. 41-54
Microstructural and Mechanical Characterization of HiMn-Hard Faced with Two Types of Buffer Layer on Q55 Railroads
- 19 October 2025
- Published by Springer Nature
- p. 41-54
Microstructural and Mechanical Characterization of HiMn-Hard Faced with Two Types of Buffer Layer on Q55 Railroads
- Open Access
- 3 July 2024
- Published by EDP Sciences
- Vol. 543, 03006
Effect of Post-Weld Treatment on the Microstructure and Mechanical Properties of Austempered FeNiCr Steel Welded Joint
This study investigated isothermally treated FeNiCr structural steel welded joints. The base metal contains various phases which are dominated by a mixture of bainite and martensite. Joining this steel can be challenging since it has high carbon equivalent values and high hardness. Shielded metal arc welding (SMAW) with austenitic stainless-steel electrodes is used to avoid cold cracking. After the welding process, the samples were subjected to three various post-weld temperatures: 425°C, 475°C, and 525°C. From the tensile test results, the tensile strength of welded joint shows an increase as the temperatures increase. The highest value is reached for a joint sample which treated at 525°C, with a tensile strength of 680 MPa. Conversely, the highest elongation is obtained by the 425°C post-treated sample, which is 14%. The microstructure in the weld metal (WM) area shows a formation of δ-ferrite, whereas the HAZ and BM areas show the presence of bainite and martensite tempered phases with various plate densities, plate size, and plate shapes depending on its post-treatment temperatures, which then affect the value of the hardness.
- 3 July 2024
- Published by EDP Sciences
- Vol. 543, 03006
Open AccessEffect of Post-Weld Treatment on the Microstructure and Mechanical Properties of Austempered FeNiCr Steel Welded Joint
This study investigated isothermally treated FeNiCr structural steel welded joints. The base metal contains various phases which are dominated by a mixture of bainite and martensite. Joining this steel can be challenging since it has high carbon equivalent values and high hardness. Shielded metal arc welding (SMAW) with austenitic stainless-steel electrodes is used to avoid cold cracking. After the welding process, the samples were subjected to three various post-weld temperatures: 425°C, 475°C, and 525°C. From the tensile test results, the tensile strength of welded joint shows an increase as the temperatures increase. The highest value is reached for a joint sample which treated at 525°C, with a tensile strength of 680 MPa. Conversely, the highest elongation is obtained by the 425°C post-treated sample, which is 14%. The microstructure in the weld metal (WM) area shows a formation of δ-ferrite, whereas the HAZ and BM areas show the presence of bainite and martensite tempered phases with various plate densities, plate size, and plate shapes depending on its post-treatment temperatures, which then affect the value of the hardness.
- Open Access
- 4 July 2023
- Published by Universitas Indonesia in Journal of Materials Exploration and Findings
- Vol. 2 (2) , 4
Effect of Heat Input on Microstructure and Mechanical Properties of Submerged Arc Welded SM570-TMC Steel
SM570TMC is high-strength steel (HSS), which is commonly used in structures that require higher-strength components. In this research, submerged arc welding (SAW)-welded SM570 TMC steels' microstructure and mechanical characteristics were examined. SM570 plates with 12mm thickness were multi-pass welded by using a 3.0 mm diameter of ESAB OK Autrod 13.40 (AWS A5.23: EG) filler metal. The joint design is a single V multi-pass butt weld with a backing strip. Two welded joints were prepared by using heat inputs of 2.2 and 2.9 kJ/mm. The microstructures of two welded joints were observed by using optical microscopy and scanning electron microscope (SEM). Hardness tests were performed in the weld metal, heat-affected zone, and base metal. The mechanical properties of welded joints were assessed using the tensile test and Charpy V notch impact test in HAZ and weld metal areas. The result showed that the strength of joints is satisfactory with no fracture in weld metal while the impact energy of weld metal and HAZ is acceptable for lower temperature application.
- 4 July 2023
- Published by Universitas Indonesia in Journal of Materials Exploration and Findings
- Vol. 2 (2) , 4
Open AccessEffect of Heat Input on Microstructure and Mechanical Properties of Submerged Arc Welded SM570-TMC Steel
SM570TMC is high-strength steel (HSS), which is commonly used in structures that require higher-strength components. In this research, submerged arc welding (SAW)-welded SM570 TMC steels' microstructure and mechanical characteristics were examined. SM570 plates with 12mm thickness were multi-pass welded by using a 3.0 mm diameter of ESAB OK Autrod 13.40 (AWS A5.23: EG) filler metal. The joint design is a single V multi-pass butt weld with a backing strip. Two welded joints were prepared by using heat inputs of 2.2 and 2.9 kJ/mm. The microstructures of two welded joints were observed by using optical microscopy and scanning electron microscope (SEM). Hardness tests were performed in the weld metal, heat-affected zone, and base metal. The mechanical properties of welded joints were assessed using the tensile test and Charpy V notch impact test in HAZ and weld metal areas. The result showed that the strength of joints is satisfactory with no fracture in weld metal while the impact energy of weld metal and HAZ is acceptable for lower temperature application.
- Open Access
- 20 June 2023
- Published by Universitas Nusantara PGRI Kediri in Jurnal Mesin Nusantara
- Vol. 6 (1)
Mechanical Properties Of Welding API 5l X-65 Cladded UNS N08825 Material Due To The Effect of Welding Repair
This study evaluate the mechanical characteristics and microstructure of API 5L X-65-clad UNS N08825 during repair welding. Gas tungsten arc welding (GTAW) and shielded metal arc welding were used in combination to carry out the welding and the repair welding (SMAW). Filler metals ER NiCrMo3 and E NiCrMo3 were used throughout the GTAW and SMAW welding processes. The first specimen served as the primary focus, after which the weld areas of the remaining four specimens were ground, re-beveled, and then re-welded using the same parameters. It performed tensile testing, bending tests, Impact Charpy tests, macro photography tests, and Vickers hardness tests. Repairs weld carried out, the heat-affected zone's hardness in the capping region increased. The findings of the tensile test demonstrate that the tensile strength is not considerably impacted by the welding repair at any particular welding repair location. The biggest decline in the number is caused by the welding repair at PTR 2, which is 0.83 percent. The heat affected area (FL) value decreased by 10.44 percent according to the charpy impact test results. The PTR 1 and PTR 2 areas in the weld metal area had the lowest charpy impact test results, respectively, of 88 J and 258 J.
- 20 June 2023
- Published by Universitas Nusantara PGRI Kediri in Jurnal Mesin Nusantara
- Vol. 6 (1)
Open AccessMechanical Properties Of Welding API 5l X-65 Cladded UNS N08825 Material Due To The Effect of Welding Repair
This study evaluate the mechanical characteristics and microstructure of API 5L X-65-clad UNS N08825 during repair welding. Gas tungsten arc welding (GTAW) and shielded metal arc welding were used in combination to carry out the welding and the repair welding (SMAW). Filler metals ER NiCrMo3 and E NiCrMo3 were used throughout the GTAW and SMAW welding processes. The first specimen served as the primary focus, after which the weld areas of the remaining four specimens were ground, re-beveled, and then re-welded using the same parameters. It performed tensile testing, bending tests, Impact Charpy tests, macro photography tests, and Vickers hardness tests. Repairs weld carried out, the heat-affected zone's hardness in the capping region increased. The findings of the tensile test demonstrate that the tensile strength is not considerably impacted by the welding repair at any particular welding repair location. The biggest decline in the number is caused by the welding repair at PTR 2, which is 0.83 percent. The heat affected area (FL) value decreased by 10.44 percent according to the charpy impact test results. The PTR 1 and PTR 2 areas in the weld metal area had the lowest charpy impact test results, respectively, of 88 J and 258 J.
- Open Access
- 9 May 2023
- Published by Universitas Nusantara PGRI Kediri in Jurnal Mesin Nusantara
- Vol. 6 (1)
Comparison study of conventional underwater electrodes and electrodes with additional modification of mg
The influence of water depth, microstructure, chemical composition, welding defects, and mechanical properties affect underwater welding. In addition, the determination of electrodes for underwater welding requires unique properties, including being able to cause arcing and slag to grow on the surface of metal deposits which can protect against the effects of oxides and low hydrogen solubility. The electrodes must meet the AWS D3.6M underwater welding specification standard. In this study, the steel plate material used in AH-36 and implemented for underwater wet welding by comparing two electrodes, namely E6013 with additional Mg modifications and Broco E70XX electrodes specifically for underwater wet welding, the other Mg on E6013 rutile electrodes with modification 1 ( 3% Mg) and Modification 2 (5% Mg). The welding method with a heat input of 1.5 kJ/mm with 130 A and 2.5 kJ/mm with 140 A is carried out at 5m. The radiographic test results showed that the welded specimens at a depth of 5m showed imperfect penetration defects. It may be due to the effect of significant pressure and higher cooling rate that the weld melt cannot penetrate completely into the parent material. The tensile test results also showed an insignificant increase in the strength of the underwater welding, and the elongation was quite significant. Occurs at the E6013 electrode with modification 1 (3% Mg) and Modification 2 (5% Mg). The increase is not too significant. Penetration is not perfect. Due to significant pressure and a higher cooling rate, the molten weld cannot penetrate completely into the parent material. However, for testing the Broco E70XX electrode where there is no change in microstructure, such as electrodes modified with magnesium where only grain growth occurs, and there is Spheroidite which makes the microstructure related to mechanical properties, namely ductile.
- 9 May 2023
- Published by Universitas Nusantara PGRI Kediri in Jurnal Mesin Nusantara
- Vol. 6 (1)
Open AccessComparison study of conventional underwater electrodes and electrodes with additional modification of mg
The influence of water depth, microstructure, chemical composition, welding defects, and mechanical properties affect underwater welding. In addition, the determination of electrodes for underwater welding requires unique properties, including being able to cause arcing and slag to grow on the surface of metal deposits which can protect against the effects of oxides and low hydrogen solubility. The electrodes must meet the AWS D3.6M underwater welding specification standard. In this study, the steel plate material used in AH-36 and implemented for underwater wet welding by comparing two electrodes, namely E6013 with additional Mg modifications and Broco E70XX electrodes specifically for underwater wet welding, the other Mg on E6013 rutile electrodes with modification 1 ( 3% Mg) and Modification 2 (5% Mg). The welding method with a heat input of 1.5 kJ/mm with 130 A and 2.5 kJ/mm with 140 A is carried out at 5m. The radiographic test results showed that the welded specimens at a depth of 5m showed imperfect penetration defects. It may be due to the effect of significant pressure and higher cooling rate that the weld melt cannot penetrate completely into the parent material. The tensile test results also showed an insignificant increase in the strength of the underwater welding, and the elongation was quite significant. Occurs at the E6013 electrode with modification 1 (3% Mg) and Modification 2 (5% Mg). The increase is not too significant. Penetration is not perfect. Due to significant pressure and a higher cooling rate, the molten weld cannot penetrate completely into the parent material. However, for testing the Broco E70XX electrode where there is no change in microstructure, such as electrodes modified with magnesium where only grain growth occurs, and there is Spheroidite which makes the microstructure related to mechanical properties, namely ductile.
- Open Access
- 22 September 2022
- Published by Lembaga Penelitian dan Pengabdian kepada Masyarakat ITS in International Journal of Marine Engineering Innovation and Research
- Vol. 7 (3)
Crack Analysis Due to Fatigue Load During Subsea Pipeline Installation
Most of the subsea pipelines in Indonesia are installed using the S-Lay method with the pipelay barges equipped with mooring spreads, tensioners, and stinger. During the subsea pipeline installation, static loads occur due to the pipeline configuration from the firing line of the pipelay barge up to the seabed. The pipe will experience axial tension and bending moment in two critical areas: overbend and sagbend. In addition, fatigue loads occur during subsea pipeline installation due to environmental loads (i.e., currents and waves). Defects that are found after welding will grow due to these fatigue loads. Crack analysis with a fracture mechanic approach known as Engineering Critical Assessment (ECA) is carried out by considering the fatigue load due to significant wave height variations for 0.5m, 1.0m, and 1.8m. BS 7910 is used as a standard reference to determine the allowable defects criteria for external and internal flaws. The depth of the defect (a) is simulated from a depth of 1mm – 3mm. The analysis found that the allowable defect length is decreased by 12.7% - 25.0% from a significant wave height of 0.5m to 1.8m for the external surface flaw. While for an internal surface flaw, the allowable defect length is decreased by 5.9% - 13.6% from a significant wave height of 0.5m to 1.8m. These results can be used as a basis for subsea pipeline installation contractors to perform fatigue load sensitivity and optimize the allowable defects based on the actual wave load at the site.
- 22 September 2022
- Published by Lembaga Penelitian dan Pengabdian kepada Masyarakat ITS in International Journal of Marine Engineering Innovation and Research
- Vol. 7 (3)
Open AccessCrack Analysis Due to Fatigue Load During Subsea Pipeline Installation
Most of the subsea pipelines in Indonesia are installed using the S-Lay method with the pipelay barges equipped with mooring spreads, tensioners, and stinger. During the subsea pipeline installation, static loads occur due to the pipeline configuration from the firing line of the pipelay barge up to the seabed. The pipe will experience axial tension and bending moment in two critical areas: overbend and sagbend. In addition, fatigue loads occur during subsea pipeline installation due to environmental loads (i.e., currents and waves). Defects that are found after welding will grow due to these fatigue loads. Crack analysis with a fracture mechanic approach known as Engineering Critical Assessment (ECA) is carried out by considering the fatigue load due to significant wave height variations for 0.5m, 1.0m, and 1.8m. BS 7910 is used as a standard reference to determine the allowable defects criteria for external and internal flaws. The depth of the defect (a) is simulated from a depth of 1mm – 3mm. The analysis found that the allowable defect length is decreased by 12.7% - 25.0% from a significant wave height of 0.5m to 1.8m for the external surface flaw. While for an internal surface flaw, the allowable defect length is decreased by 5.9% - 13.6% from a significant wave height of 0.5m to 1.8m. These results can be used as a basis for subsea pipeline installation contractors to perform fatigue load sensitivity and optimize the allowable defects based on the actual wave load at the site.
- Open Access
- 3 February 2020
- Published by Pesatuan Dokter Spesialis Mata Indonesia in Ophthalmologica Indonesiana
- Vol. 46 (1) , 40
Karakteristik Klinis Kasus Pterygium di Rumah Sakit Dr. Kariadi
Pendahuluan dan Tujuan: Pterigium adalah jaringan fibrovaskular berwarna merah muda yang tumbuh pada konjungtiva. Tujuan dari penelitian ini adalah untuk melaporkan kasus pterigium di RS Kariadi Semarang. Metode: Penelitian retrospektif ini merupakan tinjauan rekam medis pasien yang datang ke bagian Oftalmologi RS Kariadi Semarang sejak bulan Maret 2012-Februari 2017. Usia, jenis kelamin, pekerjaan, lateralisasi, lokasi pterigium, terapi, kekambuhan, ketajaman visus, dan komplikasi dikumpulkan. Analisis statistik deskriptif digunakan untuk menganalisis profil demografi dan klinis pasien. Hasil: Tujuh puluh enam pasien dilibatkan dalam penelitian; 61,8% perempuan dan 31,2% laki-laki. Rerata usia adalah 46,04 ± 12,76 tahun (rentang 18-65 tahun). Sebagian besar pasien adalah ibu rumah tangga (30,3%) dan pekerja swasta (25%). Pterigium unilateral didapatkan pada 56% pasien dan 90,79% berlokasi disisi nasal. Limbal-conjunctival autograft dilakukan pada 25% pasien. Lima pasien (6,4%) mengalami kekambuhan, 2 pasien graft (4,7%) kambuh pada tahun ketiga 3 pasien tanpa graft (5,1%) mengalami kekambuhan pada tahun pertama. Koreksi tajam penglihatan terbaik antara 6/6 hingga 6/18 sebelum dan setelah perawatan didapatkan pada 40,7% dan 55,26% pasien. Komplikasi antara lain kekambuhan (6,58%) dan gangguan refraksi pasca operasi (5,26%). Kesimpulan: Sebagian besar pasien pterygium adalah wanita dan ibu rumah tangga. Sebagian besar pasien memiliki pterigium unilateral pada sisi nasal. Eksisi dengan limbal-conjunctival autograft adalah terapi yang paling sering dilakukan. Kekambuhan didapatkan lebih tinggi pada operasi tanpa graft (bare sclera) dibandingkan dengan graft.
- 3 February 2020
- Published by Pesatuan Dokter Spesialis Mata Indonesia in Ophthalmologica Indonesiana
- Vol. 46 (1) , 40
Open AccessKarakteristik Klinis Kasus Pterygium di Rumah Sakit Dr. Kariadi
Pendahuluan dan Tujuan: Pterigium adalah jaringan fibrovaskular berwarna merah muda yang tumbuh pada konjungtiva. Tujuan dari penelitian ini adalah untuk melaporkan kasus pterigium di RS Kariadi Semarang. Metode: Penelitian retrospektif ini merupakan tinjauan rekam medis pasien yang datang ke bagian Oftalmologi RS Kariadi Semarang sejak bulan Maret 2012-Februari 2017. Usia, jenis kelamin, pekerjaan, lateralisasi, lokasi pterigium, terapi, kekambuhan, ketajaman visus, dan komplikasi dikumpulkan. Analisis statistik deskriptif digunakan untuk menganalisis profil demografi dan klinis pasien. Hasil: Tujuh puluh enam pasien dilibatkan dalam penelitian; 61,8% perempuan dan 31,2% laki-laki. Rerata usia adalah 46,04 ± 12,76 tahun (rentang 18-65 tahun). Sebagian besar pasien adalah ibu rumah tangga (30,3%) dan pekerja swasta (25%). Pterigium unilateral didapatkan pada 56% pasien dan 90,79% berlokasi disisi nasal. Limbal-conjunctival autograft dilakukan pada 25% pasien. Lima pasien (6,4%) mengalami kekambuhan, 2 pasien graft (4,7%) kambuh pada tahun ketiga 3 pasien tanpa graft (5,1%) mengalami kekambuhan pada tahun pertama. Koreksi tajam penglihatan terbaik antara 6/6 hingga 6/18 sebelum dan setelah perawatan didapatkan pada 40,7% dan 55,26% pasien. Komplikasi antara lain kekambuhan (6,58%) dan gangguan refraksi pasca operasi (5,26%). Kesimpulan: Sebagian besar pasien pterygium adalah wanita dan ibu rumah tangga. Sebagian besar pasien memiliki pterigium unilateral pada sisi nasal. Eksisi dengan limbal-conjunctival autograft adalah terapi yang paling sering dilakukan. Kekambuhan didapatkan lebih tinggi pada operasi tanpa graft (bare sclera) dibandingkan dengan graft.