Hasan Mollaee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hasan Mollaee has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Seyyed Morteza Ghamari
School of Engineering Edith Cowan University Perth Australia
6 shared publications - Fatemeh Khavari
Department of Electrical and Control Engineering Shahrood University of Technology Shahrood Iran
3 shared publications - Seyyed Amirhossein Saadat
Faculty of Electrical and Robotic Engineering Shahrood University of Technology Shahrood Semnan Iran
3 shared publications - Hossein Gholizadeh Narm
Shahrood University of Technology
1 shared publication Mohammd Abdollahzadeh
Department of Control Engineering Shahid Beheshti University Tehran Iran
1 shared publication- Patrick Wheeler
University of Nottingham
1 shared publication
Latest Publications
- Open Access
- 12 April 2023
- Published by Institution of Engineering and Technology (IET) in IET Control Theory & Applications
- Vol. 17 (9) , 1132-1143
Design of a novel robust type‐2 fuzzy‐based adaptive backstepping controller optimized with antlion algorithm for buck converter
A type‐2 fuzzy logic‐based adaptive backstepping control (T2F‐ABSC) approach is presented for a DC/DC Buck converter. Lyapunov‐based backstepping control (BSC), which can guarantee convergence along with asymptotic stability of the system. Also, the black‐box technique is applied for the proposed system, which does not require an accurate mathematical model resulting in a lower computational burden, easy implementation, and lower dependency on the states of the model. On the other hand, for wider ranges of disturbances, including parametric variations, load uncertainty, supply voltage variation, and noise, this approach shows an unsuitable practical application based on its fixed gain values; therefore, the control parameters need to be optimized again to provide ideal operations. Type‐2 fuzzy structure is adopted here to optimize the gains of the ABSM in challenging conditions. Type‐2 fuzzy (T2F) has higher efficiency and faster dynamics with more adaptability to the system. To enhance the performance of the T2F, antlion optimization (ALO) has been used in this structure. ALO is a modern nature‐inspired algorithm, and it has some advantages over other optimizing algorithms. Furthermore, it has ability to find optimal answers in a shorter time, more accurately in contrast to the other optimization algorithms and is used to tune the membership function parameters of the (T2F) under the diverse search spaces. To depict the strength of the designed work, fuzzy‐PID and backstepping schemes proposed to carry out an analysis with this work.
- 12 April 2023
- Published by Institution of Engineering and Technology (IET) in IET Control Theory & Applications
- Vol. 17 (9) , 1132-1143
Open AccessDesign of a novel robust type‐2 fuzzy‐based adaptive backstepping controller optimized with antlion algorithm for buck converter
A type‐2 fuzzy logic‐based adaptive backstepping control (T2F‐ABSC) approach is presented for a DC/DC Buck converter. Lyapunov‐based backstepping control (BSC), which can guarantee convergence along with asymptotic stability of the system. Also, the black‐box technique is applied for the proposed system, which does not require an accurate mathematical model resulting in a lower computational burden, easy implementation, and lower dependency on the states of the model. On the other hand, for wider ranges of disturbances, including parametric variations, load uncertainty, supply voltage variation, and noise, this approach shows an unsuitable practical application based on its fixed gain values; therefore, the control parameters need to be optimized again to provide ideal operations. Type‐2 fuzzy structure is adopted here to optimize the gains of the ABSM in challenging conditions. Type‐2 fuzzy (T2F) has higher efficiency and faster dynamics with more adaptability to the system. To enhance the performance of the T2F, antlion optimization (ALO) has been used in this structure. ALO is a modern nature‐inspired algorithm, and it has some advantages over other optimizing algorithms. Furthermore, it has ability to find optimal answers in a shorter time, more accurately in contrast to the other optimization algorithms and is used to tune the membership function parameters of the (T2F) under the diverse search spaces. To depict the strength of the designed work, fuzzy‐PID and backstepping schemes proposed to carry out an analysis with this work.
- Open Access
- 12 May 2022
- Published by Institution of Engineering and Technology (IET) in IET Power Electronics
- Vol. 15 (13) , 1365-1379
Self‐tuning regulator adaptive controller design for DC‐DC boost converter with a novel robust improved identification method
The design of a self‐tuning regulator adaptive controller is presented for Boost converter using Pulse Width Modulation, which has been improved in dynamic with a novel Robust Improved Exponential Regressive Least Square identification scheme. Regarding the negative influences of harmful disturbances on the converters, the Minimum Degree Pole Placement technique is designed using an adaptive mechanism with an online identification technique, which is simple in structure and can provide more accurate parametric estimation and better efficiency in challenging situations, particularly against noise. Based on the right half‐plane zero structure of the Boost converter, the open‐loop system is called a non‐minimum phase system which creates some challenging constraints for the controller design. The primary objective of designing a feedback loop controller is to ensure the stability of the system and appropriate regulation within a pre‐determined range of operating conditions. This controller considers the system as a black‐box structure; thus, the mathematical model of the system is not needed. This benefit can decrease the computational burden, and provides faster dynamics along with ease of implementation. Finally, the strength of this control strategy is tested by experimental and simulation results in different conditions.
- 12 May 2022
- Published by Institution of Engineering and Technology (IET) in IET Power Electronics
- Vol. 15 (13) , 1365-1379
Open AccessSelf‐tuning regulator adaptive controller design for DC‐DC boost converter with a novel robust improved identification method
The design of a self‐tuning regulator adaptive controller is presented for Boost converter using Pulse Width Modulation, which has been improved in dynamic with a novel Robust Improved Exponential Regressive Least Square identification scheme. Regarding the negative influences of harmful disturbances on the converters, the Minimum Degree Pole Placement technique is designed using an adaptive mechanism with an online identification technique, which is simple in structure and can provide more accurate parametric estimation and better efficiency in challenging situations, particularly against noise. Based on the right half‐plane zero structure of the Boost converter, the open‐loop system is called a non‐minimum phase system which creates some challenging constraints for the controller design. The primary objective of designing a feedback loop controller is to ensure the stability of the system and appropriate regulation within a pre‐determined range of operating conditions. This controller considers the system as a black‐box structure; thus, the mathematical model of the system is not needed. This benefit can decrease the computational burden, and provides faster dynamics along with ease of implementation. Finally, the strength of this control strategy is tested by experimental and simulation results in different conditions.
- Open Access
- 13 February 2022
- Published by Institution of Engineering and Technology (IET) in IET Control Theory & Applications
- Vol. 16 (5) , 485-495
Adaptive backstepping controller design on Buck converter with a novel improved identification method
An adaptive backstepping method is presented by this paper for a DC–DC Buck converter utilising a strategy for system identification with pulse width modulation in the presence of parametric uncertainties, load variations, and high variance noises. In this control structure, the system is assumed as a black‐box block that can decrease the computational burden providing faster dynamics. An adaptive mechanism is adopted for the BSM using the Lyapunov definition, providing robust dynamics for the controller against various disturbances. In addition, a novel improved exponential recursive least‐squares identification algorithm is proposed, which shows higher robustness in parametric estimations and can decrease the negative impact of disrupting factors on the estimator. Moreover, a particle swarm optimisation algorithm‐based PID controller is designed to be compared with the proposed controller. Finally, the merits of the presented controller are validated for various working conditions through simulations and experiments. It can be seen that the adaptive backstepping method with the improved identification technique provides much better results with faster dynamics.
- 13 February 2022
- Published by Institution of Engineering and Technology (IET) in IET Control Theory & Applications
- Vol. 16 (5) , 485-495
Open AccessAdaptive backstepping controller design on Buck converter with a novel improved identification method
An adaptive backstepping method is presented by this paper for a DC–DC Buck converter utilising a strategy for system identification with pulse width modulation in the presence of parametric uncertainties, load variations, and high variance noises. In this control structure, the system is assumed as a black‐box block that can decrease the computational burden providing faster dynamics. An adaptive mechanism is adopted for the BSM using the Lyapunov definition, providing robust dynamics for the controller against various disturbances. In addition, a novel improved exponential recursive least‐squares identification algorithm is proposed, which shows higher robustness in parametric estimations and can decrease the negative impact of disrupting factors on the estimator. Moreover, a particle swarm optimisation algorithm‐based PID controller is designed to be compared with the proposed controller. Finally, the merits of the presented controller are validated for various working conditions through simulations and experiments. It can be seen that the adaptive backstepping method with the improved identification technique provides much better results with faster dynamics.
- Top Cited PapersOpen Access
- 7 December 2021
- Published by Institution of Engineering and Technology (IET) in IET Control Theory & Applications
- Vol. 16 (3) , 340-352
Fractional‐order fuzzy PID controller design on buck converter with antlion optimization algorithm
The design of a Fractional‐Order fuzzy‐based PID (FO‐F‐PID) control structure is presented for Buck converter in the presence of harmful disturbances. A fractional‐order proportional‐integral‐derivative (FO‐PID) control scheme is utilized initially to damp the oscillations and remove the steady‐state error. To increase the tendency rate of the error to zero, the FO‐PID method is applied to a fuzzy‐logic‐based compensatory stage. At the same time, the fuzzy part gathers the data based on the error and error derivative. The FO‐PID control scheme has the capability to enhance the robustness of the control technique against disturbances and parametric variations. Furthermore, to optimize the control parameters, an efficient algorithm so‐called Antlion Optimization (ALO) algorithm, is used. Utilizing the ALO algorithm for tuning the FO‐PID gains depicts more accurate responses in solving constrained problems with diverse search spaces. Considering numerous disturbances on DC‐DC converters, an FO‐F‐PID controller can be an appropriate alternative since it is more robust against load variations and noise. Moreover, PSO‐PID and FO‐PSO‐PID controllers are designed to drive a comparison between them. Finally, the merits of the presented controller are validated for various scenarios. It can be seen that the FO‐F‐ALO‐PID method provides much better results with faster dynamics. Matlab‐Simulink environment is used for the simulations, and the experimental results are tested by the micro‐processor to validate the superiority of the proposed method.
- 7 December 2021
- Published by Institution of Engineering and Technology (IET) in IET Control Theory & Applications
- Vol. 16 (3) , 340-352
Top Cited PapersOpen AccessFractional‐order fuzzy PID controller design on buck converter with antlion optimization algorithm
The design of a Fractional‐Order fuzzy‐based PID (FO‐F‐PID) control structure is presented for Buck converter in the presence of harmful disturbances. A fractional‐order proportional‐integral‐derivative (FO‐PID) control scheme is utilized initially to damp the oscillations and remove the steady‐state error. To increase the tendency rate of the error to zero, the FO‐PID method is applied to a fuzzy‐logic‐based compensatory stage. At the same time, the fuzzy part gathers the data based on the error and error derivative. The FO‐PID control scheme has the capability to enhance the robustness of the control technique against disturbances and parametric variations. Furthermore, to optimize the control parameters, an efficient algorithm so‐called Antlion Optimization (ALO) algorithm, is used. Utilizing the ALO algorithm for tuning the FO‐PID gains depicts more accurate responses in solving constrained problems with diverse search spaces. Considering numerous disturbances on DC‐DC converters, an FO‐F‐PID controller can be an appropriate alternative since it is more robust against load variations and noise. Moreover, PSO‐PID and FO‐PSO‐PID controllers are designed to drive a comparison between them. Finally, the merits of the presented controller are validated for various scenarios. It can be seen that the FO‐F‐ALO‐PID method provides much better results with faster dynamics. Matlab‐Simulink environment is used for the simulations, and the experimental results are tested by the micro‐processor to validate the superiority of the proposed method.
- Open Access
- 2 July 2021
- Published by Institution of Engineering and Technology (IET) in IET Power Electronics
- Vol. 14 (11) , 1960-1972
Adaptive neuro‐fuzzy inference systems (ANFIS) controller design on single‐phase full‐bridge inverter with a cascade fractional‐order PID voltage controller
Adaptive neuro‐fuzzy inference system (ANFIS) technique is a significant alternative of research which is structured with a combination of two soft‐computing strategies of fuzzy logic and artificial neural network. The design of ANFIS controller for a single‐phase full‐bridge inverter with pulse width modulation is demonstrated here in the presence of different disturbances. Moreover, an LC filter is designed to decrease the disturbing harmonics which the stability of the filter can be noted as an important issue. Based on the fuzzy C‐mean clustering method used for decreasing fuzzy rules, the computational burden has been improved resulting in faster dynamic performance. This method considers the system as a black‐box structure which omits the need for an exact model of system and can be an appropriate technique for ill‐defined systems. Additionally, to deal with the variations of supply DC voltage, a fractional‐order proportional‐integral‐derivative controller is designed which is tuned by particle swarm optimiser algorithm and can generate a sinusoidal reference for the system input. This double‐loop control technique is known as cascade control strategy. It can be seen that ANFIS scheme provides appropriate results with less computational burden and simple structure with optimised responses in challenging conditions. The capability of the proposed method is validated for different operating conditions through simulation and experimental results.
- 2 July 2021
- Published by Institution of Engineering and Technology (IET) in IET Power Electronics
- Vol. 14 (11) , 1960-1972
Open AccessAdaptive neuro‐fuzzy inference systems (ANFIS) controller design on single‐phase full‐bridge inverter with a cascade fractional‐order PID voltage controller
Adaptive neuro‐fuzzy inference system (ANFIS) technique is a significant alternative of research which is structured with a combination of two soft‐computing strategies of fuzzy logic and artificial neural network. The design of ANFIS controller for a single‐phase full‐bridge inverter with pulse width modulation is demonstrated here in the presence of different disturbances. Moreover, an LC filter is designed to decrease the disturbing harmonics which the stability of the filter can be noted as an important issue. Based on the fuzzy C‐mean clustering method used for decreasing fuzzy rules, the computational burden has been improved resulting in faster dynamic performance. This method considers the system as a black‐box structure which omits the need for an exact model of system and can be an appropriate technique for ill‐defined systems. Additionally, to deal with the variations of supply DC voltage, a fractional‐order proportional‐integral‐derivative controller is designed which is tuned by particle swarm optimiser algorithm and can generate a sinusoidal reference for the system input. This double‐loop control technique is known as cascade control strategy. It can be seen that ANFIS scheme provides appropriate results with less computational burden and simple structure with optimised responses in challenging conditions. The capability of the proposed method is validated for different operating conditions through simulation and experimental results.
- Open Access
- 21 June 2021
- Published by Institution of Engineering and Technology (IET) in IET Power Electronics
- Vol. 14 (11) , 1920-1935
A novel adaptive cascade controller design on a buck–boost DC–DC converter with a fractional‐order PID voltage controller and a self‐tuning regulator adaptive current controller
The design of a cascade controller is demonstrated for a buck–boost converter that is combined with two control loops consisting of inner and outer controllers. The outer loop is implemented by a fractional‐order proportional‐integrated‐derivative (FO‐PID) controller that works as a voltage controller and generates a reference current for the inner control loop. To provide faster dynamic performance for inner loop, a self‐tuning regulator adaptive controller, which tries to regulates the current with the help of a novel improved exponential regressive least square identification in an online technique, is designed. Moreover, in the outer loop, to tune the gains of the FO‐PID controller, a novel algorithm of antlion optimizer algorithm is used that offers many benefits in comparison with other algorithms. The system provided by the boost mode is a non‐minimum phase system, which creates challenges for designing a stable controller. In addition, a single loop controller is proposed based on a PID controller tuned by a particle swarm optimization algorithm to be compared with the cascade controller. Cascade loop can present significant benefits to the controller such as better disturbance rejection. Finally, the strength of the presented cascade control scheme is verified in different performing situations by real‐time experiments.
- 21 June 2021
- Published by Institution of Engineering and Technology (IET) in IET Power Electronics
- Vol. 14 (11) , 1920-1935
Open AccessA novel adaptive cascade controller design on a buck–boost DC–DC converter with a fractional‐order PID voltage controller and a self‐tuning regulator adaptive current controller
The design of a cascade controller is demonstrated for a buck–boost converter that is combined with two control loops consisting of inner and outer controllers. The outer loop is implemented by a fractional‐order proportional‐integrated‐derivative (FO‐PID) controller that works as a voltage controller and generates a reference current for the inner control loop. To provide faster dynamic performance for inner loop, a self‐tuning regulator adaptive controller, which tries to regulates the current with the help of a novel improved exponential regressive least square identification in an online technique, is designed. Moreover, in the outer loop, to tune the gains of the FO‐PID controller, a novel algorithm of antlion optimizer algorithm is used that offers many benefits in comparison with other algorithms. The system provided by the boost mode is a non‐minimum phase system, which creates challenges for designing a stable controller. In addition, a single loop controller is proposed based on a PID controller tuned by a particle swarm optimization algorithm to be compared with the cascade controller. Cascade loop can present significant benefits to the controller such as better disturbance rejection. Finally, the strength of the presented cascade control scheme is verified in different performing situations by real‐time experiments.