Jaromíra Hrdá
Jaromíra Hrdá has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Jaromír Hrdý
Institute of Physics, Academy of Sciences of the Czech Republic, Na Slovance 2, 18221 Praha 8, Czech Republic
5 shared publications - Peter Oberta
Rigaku Innovative Technologies Europe s.r.o. 5 , Dolní Břežany 252 41
2 shared publications - Andreas K. Freund
Consultant, 40 Rue Auguste Poirson, 33000 Bordeaux, France
1 shared publication - Eric Ziegler
European Synchrotron Radiation Facility, CS 40220, F-38043 Grenoble Cedex 9, France
1 shared publication F. Franc
Institute of Physics, Academy of Sciences of the Czech Republic, Na Slovance 2, 18221 Praha 8, Czech Republic
1 shared publication- Gwladys Steciuk
Institut Jean Lamour Université De Lorraine, CNRS Nancy France
1 shared publication
Latest Publications
- Top Cited Papers
- 1 August 2019
- Published by International Union of Crystallography (IUCr) in Acta crystallographica Section B, Structural science, crystal engineering and materials
- Vol. 75 (4) , 512-522
Specifics of the data processing of precession electron diffraction tomography data and their implementation in the program PETS2.0
Electron diffraction tomography (EDT) data are in many ways similar to X-ray diffraction data. However, they also present certain specifics. One of the most noteworthy is the specific rocking curve observed for EDT data collected using the precession electron diffraction method. This double-peaked curve (dubbed `the camel') may be described with an approximation based on a circular integral of a pseudo-Voigt function and used for intensity extraction by profile fitting. Another specific aspect of electron diffraction data is the high likelihood of errors in the estimation of the crystal orientation, which may arise from the inaccuracies of the goniometer reading, crystal deformations or crystal movement during the data collection. A method for the refinement of crystal orientation for each frame individually is proposed based on the least-squares optimization of simulated diffraction patterns. This method provides typical angular accuracy of the frame orientations of less than 0.05°. These features were implemented in the computer program PETS 2.0. The implementation of the complete data processing workflow in the program PETS and the incorporation of the features specific for electron diffraction data is also described.
- 1 August 2019
- Published by International Union of Crystallography (IUCr) in Acta crystallographica Section B, Structural science, crystal engineering and materials
- Vol. 75 (4) , 512-522
Top Cited PapersSpecifics of the data processing of precession electron diffraction tomography data and their implementation in the program PETS2.0
Electron diffraction tomography (EDT) data are in many ways similar to X-ray diffraction data. However, they also present certain specifics. One of the most noteworthy is the specific rocking curve observed for EDT data collected using the precession electron diffraction method. This double-peaked curve (dubbed `the camel') may be described with an approximation based on a circular integral of a pseudo-Voigt function and used for intensity extraction by profile fitting. Another specific aspect of electron diffraction data is the high likelihood of errors in the estimation of the crystal orientation, which may arise from the inaccuracies of the goniometer reading, crystal deformations or crystal movement during the data collection. A method for the refinement of crystal orientation for each frame individually is proposed based on the least-squares optimization of simulated diffraction patterns. This method provides typical angular accuracy of the frame orientations of less than 0.05°. These features were implemented in the computer program PETS 2.0. The implementation of the complete data processing workflow in the program PETS and the incorporation of the features specific for electron diffraction data is also described.
- 1 October 2016
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 834, 169-174
The X-ray bichromator – Theory and alignment
- 1 October 2016
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 834, 169-174
The X-ray bichromator – Theory and alignment
- 1 January 2016
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 807, 61-63
Two (and more) sharp X-ray wavelengths in one beam
- 1 January 2016
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 807, 61-63
Two (and more) sharp X-ray wavelengths in one beam
- 12 November 2011
- Published by International Union of Crystallography (IUCr) in Journal of Applied Crystallography
- Vol. 44 (6) , 1169-1172
Self-filtering extremely inclined X-ray crystal monochromator
It is shown that an extremely inclined X-ray double-crystal monochromator can diffract a beam with the required wavelength and at the same time may reflect a great deal of unwanted radiation in a broad range of Bragg angles. This is a generalization of the idea of Cowan & Brennan [Rev. Sci. Instrum.(1989),60, 1987–1990], which partially solves the radiation heat load problem. The properties of such a device are discussed. It is shown that in some cases the diffracted beam may be significantly broadened as a result of refraction effects. In these cases a four-crystal arrangement or an additional mirror is necessary.
- 12 November 2011
- Published by International Union of Crystallography (IUCr) in Journal of Applied Crystallography
- Vol. 44 (6) , 1169-1172
Self-filtering extremely inclined X-ray crystal monochromator
It is shown that an extremely inclined X-ray double-crystal monochromator can diffract a beam with the required wavelength and at the same time may reflect a great deal of unwanted radiation in a broad range of Bragg angles. This is a generalization of the idea of Cowan & Brennan [Rev. Sci. Instrum.(1989),60, 1987–1990], which partially solves the radiation heat load problem. The properties of such a device are discussed. It is shown that in some cases the diffracted beam may be significantly broadened as a result of refraction effects. In these cases a four-crystal arrangement or an additional mirror is necessary.
- 1 December 2006
- Published by Springer Nature in Czechoslovak Journal of Physics
- Vol. 56 (12) , 1421-1427
Harmonic-free channel-cut x-ray crystal monochromator with focusing effect
- 1 December 2006
- Published by Springer Nature in Czechoslovak Journal of Physics
- Vol. 56 (12) , 1421-1427
Harmonic-free channel-cut x-ray crystal monochromator with focusing effect
- 6 May 2005
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 38 (10A) , A223-A226
Influence of the crystal-surface unevenness on the angular spread of an x-ray diffracted beam
- 6 May 2005
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 38 (10A) , A223-A226
Influence of the crystal-surface unevenness on the angular spread of an x-ray diffracted beam
- 31 December 2003
- Published by SPIE-Intl Soc Optical Eng
- p. 109-114
Influence of crystal surface roughness on the angular spread of x-ray diffracted beam
One of the factors influencing the focus size in diffractive-refractive optics is the quality of diffracting surface. If the surface is uneven, then the diffraction at each point of the surface is a combination of an asymmetric and inclined diffraction (general asymmetric diffraction). This somewhat deviates and spreads the diffracted beam. The integration over the surface hit by an incident beam gives the angular spread of the diffracted beam. It is shown that in some cases (highly asymmetric, highly inclined cut) the etched surface may create the spread of the diffracted beam, such that it causes a significant broadening of the focus. In this case a mechanical-chemical polishing is necessary.
- 31 December 2003
- Published by SPIE-Intl Soc Optical Eng
- p. 109-114
Influence of crystal surface roughness on the angular spread of x-ray diffracted beam
One of the factors influencing the focus size in diffractive-refractive optics is the quality of diffracting surface. If the surface is uneven, then the diffraction at each point of the surface is a combination of an asymmetric and inclined diffraction (general asymmetric diffraction). This somewhat deviates and spreads the diffracted beam. The integration over the surface hit by an incident beam gives the angular spread of the diffracted beam. It is shown that in some cases (highly asymmetric, highly inclined cut) the etched surface may create the spread of the diffracted beam, such that it causes a significant broadening of the focus. In this case a mechanical-chemical polishing is necessary.
- Open Access
- 25 October 2001
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 8 (6) , 1203-1206
First observation of meridional focusing of an X-ray beam using diffraction by a crystal with a transverse groove
The possibility of concentrating a synchrotron X-ray beam using diffraction by a single crystal with a properly designed transverse groove on its surface, suggested earlier, has been studied experimentally. Here, the first experimental demonstration of this effect is reported, performed on beamline BM5 at the ESRF. The experimental result confirms the theoretical model.
- 25 October 2001
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 8 (6) , 1203-1206
Open AccessFirst observation of meridional focusing of an X-ray beam using diffraction by a crystal with a transverse groove
The possibility of concentrating a synchrotron X-ray beam using diffraction by a single crystal with a properly designed transverse groove on its surface, suggested earlier, has been studied experimentally. Here, the first experimental demonstration of this effect is reported, performed on beamline BM5 at the ESRF. The experimental result confirms the theoretical model.
- 1 March 2000
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 7 (2) , 78-80
Meridional focusing of X-rays diffracted onto a single crystal with a transversal groove (Bragg-diffraction asymmetric lens)
It is shown that a properly designed transversal groove machined into the surface of a single-crystal monochromator may concentrate (focus) the diffracted radiation meridionally. From this result and from previous papers on the Bragg-diffraction inclined lens it follows that a properly designed depression fabricated into the surface of a single-crystal monochromator should provide two-dimensional focusing of a diffracted synchrotron radiation beam.
- 1 March 2000
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 7 (2) , 78-80
Meridional focusing of X-rays diffracted onto a single crystal with a transversal groove (Bragg-diffraction asymmetric lens)
It is shown that a properly designed transversal groove machined into the surface of a single-crystal monochromator may concentrate (focus) the diffracted radiation meridionally. From this result and from previous papers on the Bragg-diffraction inclined lens it follows that a properly designed depression fabricated into the surface of a single-crystal monochromator should provide two-dimensional focusing of a diffracted synchrotron radiation beam.