Akam Saeidi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Akam Saeidi has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Elham Mahmoudi
Institute of Health Research , Dental Materials Research Center , Babol University of Medical Sciences , Babol 47745 , Iran , mubabol.ac.ir
3 shared publications - Hemmat Gholinia
Health Research Institute, Babol University of Medical Sciences, Babol, Iran
2 shared publications - Zahra Sadat Madani
Dental Materials Research Center, Health Research Institute, Babol University of Medical Sciences, Babol, IR Iran
2 shared publications - Ali Bijani
Social Determinant of Health Research Center, Babol University of Medical Sciences, Babol, Iran
1 shared publication - Arezoo Mirzaei Sadeghloo
Student Research Committee, Babol University of Medical Sciences, Babol, Mazandaran, Iran, mubabol.ac.ir
1 shared publication - Azam Haddadi
Department of Endodontics, Dental Research Center, Mazandaran University of Medical Sciences, Sari, Iran
1 shared publication
Latest Publications
- 1 June 2026
- Published by InkVista Publishing House
- Vol. 11 (2) , 97-106
Efficacy of ProTaper, M3, and Edge Endo Rotary Files for Removal of Root Canal Filling Materials: An Ex Vivo Study Using CBCT
- 1 June 2026
- Published by InkVista Publishing House
- Vol. 11 (2) , 97-106
Efficacy of ProTaper, M3, and Edge Endo Rotary Files for Removal of Root Canal Filling Materials: An Ex Vivo Study Using CBCT
- Open Access
- 1 January 2026
- Published by Wiley in Journal of Chemistry
- Vol. 2026 (1) , 6072815
Ziziphus spina-christi Nanoemulsion Enhances the Antibacterial Activity on Enterococcus faecalis Biofilm
This study aimed to investigate the antimicrobial and antibiofilm properties of hydroalcoholic extracts derived from the Ziziphus spina-christi ( Z. spina ) extract and Z. spina nanoemulsion ( Z. spina nano) against the bacterium Enterococcus faecalis . Z. spina nanoparticles were prepared and characterized using SEM, DLS, and zeta potential analyses. High‐performance liquid chromatography was used to identify and quantify rutin flavonoid. The antimicrobial and antibiofilm activities of the Z. spina extract, Z. spina nano, and sodium hypochlorite (NaOCl 5.25%) were evaluated against clinical isolates of E. faecalis obtained from infected root canals. The results showed that the Z. spina extract contained rutin flavonoid (3.7%). The nanoemulsion exhibited enhanced antimicrobial activity, requiring approximately threefold‐lower concentrations than the crude extract to inhibit bacterial growth. In addition, treatment with Z. spina extract and nanoemulsion significantly reduced biofilm formation compared with untreated controls, with mean inhibition values of 45.60% ± 2 and 59.70% ± 2.5, respectively. Although the antimicrobial potency of Z. spina formulations was lower than that of conventional irrigants, nanoformulation improved their antibacterial and antibiofilm performance. The findings suggest that Z. spina nano may serve as a promising adjunct natural antimicrobial candidate for endodontic applications; however, further studies under clinically relevant conditions and comprehensive biocompatibility assessments are required before clinical translation.
- 1 January 2026
- Published by Wiley in Journal of Chemistry
- Vol. 2026 (1) , 6072815
Open AccessZiziphus spina-christi Nanoemulsion Enhances the Antibacterial Activity on Enterococcus faecalis Biofilm
This study aimed to investigate the antimicrobial and antibiofilm properties of hydroalcoholic extracts derived from the Ziziphus spina-christi ( Z. spina ) extract and Z. spina nanoemulsion ( Z. spina nano) against the bacterium Enterococcus faecalis . Z. spina nanoparticles were prepared and characterized using SEM, DLS, and zeta potential analyses. High‐performance liquid chromatography was used to identify and quantify rutin flavonoid. The antimicrobial and antibiofilm activities of the Z. spina extract, Z. spina nano, and sodium hypochlorite (NaOCl 5.25%) were evaluated against clinical isolates of E. faecalis obtained from infected root canals. The results showed that the Z. spina extract contained rutin flavonoid (3.7%). The nanoemulsion exhibited enhanced antimicrobial activity, requiring approximately threefold‐lower concentrations than the crude extract to inhibit bacterial growth. In addition, treatment with Z. spina extract and nanoemulsion significantly reduced biofilm formation compared with untreated controls, with mean inhibition values of 45.60% ± 2 and 59.70% ± 2.5, respectively. Although the antimicrobial potency of Z. spina formulations was lower than that of conventional irrigants, nanoformulation improved their antibacterial and antibiofilm performance. The findings suggest that Z. spina nano may serve as a promising adjunct natural antimicrobial candidate for endodontic applications; however, further studies under clinically relevant conditions and comprehensive biocompatibility assessments are required before clinical translation.
- Open Access
- 1 January 2025
- Published by Wiley in International Journal of Dentistry
- Vol. 2025 (1)
Correlation of Bond Strength and Dentinal Tubule Penetration Evaluation of Four Different Endodontic Sealers: AH Plus, MTA Fillapex, Endoseal MTA, and Endoseal TCS (Maruchi): An In Vitro Study
Background: The sealer’s penetration into dentinal tubules creates a physical barrier that entombs any remaining bacteria and increases the surface contact with the root canal walls. This study aimed to evaluate the dentinal tubule penetration and push‐out bond strength of four sealers and to assess the correlation between penetration depth and bond strength. Methods: In this in vitro study, 40 human single‐rooted anterior teeth were divided into four groups based on the sealer type and obturated using the single cone technique. Three slices of 1 ± 0.1 mm thickness were then prepared from each tooth at three regions—coronal, middle, and apical thirds—perpendicular to the longitudinal axis of the root. The depth and percentage of sealer penetration into the dentinal tubules were measured using confocal laser scanning microscopy (CLSM) on the prepared slices. To assess the bond strength of the sealers to dentin walls, a push‐out bond strength test was performed using a universal testing machine. Data were analyzed using SPSS software through ANOVA, Tukey post hoc and Pearson’s correlation tests. A p ‐value of p < 0.001 for all). Additionally, a significant correlation was found between bond strength and penetration percentage for AH Plus ( p = 0.046 and r = 0.366), between bond strength and both penetration extent ( p = 0.013 and r = 0.448) and penetration percentage ( p = 0.001 and r = 0.572) for Endoseal MTA, and between bond strength and penetration extent for Endoseal TCS ( p = 0.001 and r = 0.57). Conclusion: Calcium silicate‐based sealers (Endoseal MTA and Endoseal TCS) achieved the greatest penetration, whereas AH Plus demonstrated the highest bond strength. The positive correlations observed suggest that dentinal tubule penetration may contribute to stronger bonding for specific sealers.
- 1 January 2025
- Published by Wiley in International Journal of Dentistry
- Vol. 2025 (1)
Open AccessCorrelation of Bond Strength and Dentinal Tubule Penetration Evaluation of Four Different Endodontic Sealers: AH Plus, MTA Fillapex, Endoseal MTA, and Endoseal TCS (Maruchi): An In Vitro Study
Background: The sealer’s penetration into dentinal tubules creates a physical barrier that entombs any remaining bacteria and increases the surface contact with the root canal walls. This study aimed to evaluate the dentinal tubule penetration and push‐out bond strength of four sealers and to assess the correlation between penetration depth and bond strength. Methods: In this in vitro study, 40 human single‐rooted anterior teeth were divided into four groups based on the sealer type and obturated using the single cone technique. Three slices of 1 ± 0.1 mm thickness were then prepared from each tooth at three regions—coronal, middle, and apical thirds—perpendicular to the longitudinal axis of the root. The depth and percentage of sealer penetration into the dentinal tubules were measured using confocal laser scanning microscopy (CLSM) on the prepared slices. To assess the bond strength of the sealers to dentin walls, a push‐out bond strength test was performed using a universal testing machine. Data were analyzed using SPSS software through ANOVA, Tukey post hoc and Pearson’s correlation tests. A p ‐value of p < 0.001 for all). Additionally, a significant correlation was found between bond strength and penetration percentage for AH Plus ( p = 0.046 and r = 0.366), between bond strength and both penetration extent ( p = 0.013 and r = 0.448) and penetration percentage ( p = 0.001 and r = 0.572) for Endoseal MTA, and between bond strength and penetration extent for Endoseal TCS ( p = 0.001 and r = 0.57). Conclusion: Calcium silicate‐based sealers (Endoseal MTA and Endoseal TCS) achieved the greatest penetration, whereas AH Plus demonstrated the highest bond strength. The positive correlations observed suggest that dentinal tubule penetration may contribute to stronger bonding for specific sealers.
- Open Access
- 31 August 2021
- Published by Hindawi Limited in International Journal of Biomaterials
- Vol. 2021, 1-6
Comparison of Rat Connective Tissue Response to BioMTA, Angelus MTA, and Root MTA
Due to the widespread use of MTA in dentistry and various brands of this product, we decided to compare the three brands available in the country market by their biocompatibility. We divided 20 male Wistar rats into four groups. After local anesthesia and washing, we made two incisions on both sides (4 incisions in total). The experimental groups were Angelus MTA (Angelus, Brazil), BioMTA (CERKAMED, Poland), Root MTA (Dr. Lotfi, Tabriz, Iran), and the control group. The resulting paste was placed in a tube and implanted subcutaneously into male Wistar rats. Wistar rats were sacrificed 7, 15, 30, and 60 days later, with high anesthetic doses. The sample implanted in 10% formalin was stabilized after tissue processing and H&E staining under a microscope. The inflammatory reaction in the tissues received different scores at the beginning of the tube opening. BioMTA had the highest inflammatory response among the groups, but the difference was not statistically significant ( > 0.05). Also, there was no significant difference between the groups’ granulation and calcification ( < 0.05). There was a significant difference between BioMTA, Angelus MTA, Root MTA, and control groups in fibrous capsule formation ( < 0.05). Angelus MTA showed the lowest mean fibrous capsule formation in all periods. The effects of Angelus MTA, Root MTA, and BioMTA on connective tissue were investigated and compared. According to this study, these materials have good biocompatibility. According to the findings and statistical analysis, Angelus MTA has the most biocompatibility.
- 31 August 2021
- Published by Hindawi Limited in International Journal of Biomaterials
- Vol. 2021, 1-6
Open AccessComparison of Rat Connective Tissue Response to BioMTA, Angelus MTA, and Root MTA
Due to the widespread use of MTA in dentistry and various brands of this product, we decided to compare the three brands available in the country market by their biocompatibility. We divided 20 male Wistar rats into four groups. After local anesthesia and washing, we made two incisions on both sides (4 incisions in total). The experimental groups were Angelus MTA (Angelus, Brazil), BioMTA (CERKAMED, Poland), Root MTA (Dr. Lotfi, Tabriz, Iran), and the control group. The resulting paste was placed in a tube and implanted subcutaneously into male Wistar rats. Wistar rats were sacrificed 7, 15, 30, and 60 days later, with high anesthetic doses. The sample implanted in 10% formalin was stabilized after tissue processing and H&E staining under a microscope. The inflammatory reaction in the tissues received different scores at the beginning of the tube opening. BioMTA had the highest inflammatory response among the groups, but the difference was not statistically significant ( > 0.05). Also, there was no significant difference between the groups’ granulation and calcification ( < 0.05). There was a significant difference between BioMTA, Angelus MTA, Root MTA, and control groups in fibrous capsule formation ( < 0.05). Angelus MTA showed the lowest mean fibrous capsule formation in all periods. The effects of Angelus MTA, Root MTA, and BioMTA on connective tissue were investigated and compared. According to this study, these materials have good biocompatibility. According to the findings and statistical analysis, Angelus MTA has the most biocompatibility.
- Open Access
- 24 December 2014
- Vol. 10 (1) , 44-8
A CBCT Assessment of Apical Transportation in Root Canals Prepared with Hand K-Flexofile and K3 Rotary Instruments.
Apical transportation changes the physical shape and physiologic environment of the root canal terminus. The aim of the present experimental study was to determine the extent of apical transportation after instrumentation with hand K-Flexofile and K3 rotary instruments by means of cone-beam computed tomography (CBCT). Forty mesiobuccal root canals of maxillary first molars, with 19-22 mm length and 20-40(°) canal curvature, were selected and assigned into two preparation groups. The first group was prepared with K-Flexofile with passive step-back technique and the second group was prepared with K3 rotary instruments. Pre and post instrumentation CBCT images were taken under similar conditions. The amount of root canal transportation was evaluated by Mann-Whitney U test and the chi-square test was used for the qualitative evaluation. The amounts of apical canal transportation with the K3 and K-Flexofile instruments were 0.105±0.088 and 0.150±0.127 mm, respectively with no statistically significant differences. In the manual technique, 25% of the canals had no apical transportation; while 30% of the canals in the K3 group were transportation free. Both systems were able to preserve the initial curvature of the canals and both had sufficient accuracy. Preparation with K3 rotary instruments resulted in apical transportation similar to that of K-Flexofile.
- 24 December 2014
- Vol. 10 (1) , 44-8
Open AccessA CBCT Assessment of Apical Transportation in Root Canals Prepared with Hand K-Flexofile and K3 Rotary Instruments.
Apical transportation changes the physical shape and physiologic environment of the root canal terminus. The aim of the present experimental study was to determine the extent of apical transportation after instrumentation with hand K-Flexofile and K3 rotary instruments by means of cone-beam computed tomography (CBCT). Forty mesiobuccal root canals of maxillary first molars, with 19-22 mm length and 20-40(°) canal curvature, were selected and assigned into two preparation groups. The first group was prepared with K-Flexofile with passive step-back technique and the second group was prepared with K3 rotary instruments. Pre and post instrumentation CBCT images were taken under similar conditions. The amount of root canal transportation was evaluated by Mann-Whitney U test and the chi-square test was used for the qualitative evaluation. The amounts of apical canal transportation with the K3 and K-Flexofile instruments were 0.105±0.088 and 0.150±0.127 mm, respectively with no statistically significant differences. In the manual technique, 25% of the canals had no apical transportation; while 30% of the canals in the K3 group were transportation free. Both systems were able to preserve the initial curvature of the canals and both had sufficient accuracy. Preparation with K3 rotary instruments resulted in apical transportation similar to that of K-Flexofile.