Nur Çobanoğlu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Nur Çobanoğlu has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
Ziya Haktan Karadeniz
4 shared publications- Ziya Haktan Karadeniz
İzmir Institute of Technology
4 shared publications - Alpaslan Turgut
Department of Mechanical Engineering, Dokuz Eylul University, Izmir, Turkey
2 shared publications Alper Mete Genç
Izmir Katip Celebi Univ, Grad Sch Nat & Appl Sci, TR-35620 Izmir, Turkey
2 shared publications- Matthias H. Buschmann
Institut für Luft- und Kältetechnik gGmbH Dresden, Dresden, Germany
2 shared publications - Patrice Estellé
Univ Rennes, LGCGM, Rennes, France
2 shared publications
Latest Publications
- 1 April 2026
- Published by Springer Nature
- p. 271-280
Numerical Investigation of Ventilation Design Effects on Exposure Equality in Ventilated Classrooms
- 1 April 2026
- Published by Springer Nature
- p. 271-280
Numerical Investigation of Ventilation Design Effects on Exposure Equality in Ventilated Classrooms
- Open Access
- 11 June 2024
- Published by Gumushane University Journal of Science and Technology Institute in Gümüşhane Üniversitesi Fen Bilimleri Enstitüsü Dergisi
Düşük maliyetli ve özel tasarım çift ışınlı optik cımbızın performans özellikleri
Bu çalışmada, mikron boyutundaki partikülleri yakalamak ve manipüle etmek için paralel olarak konumlandırılmış iki adet He-Ne lazer (λ=632.8 nm) kullanan düşük bütçeli ve özel tasarlanmış bir optik cımbız geliştirilmiştir. Bu kapsamda örnek olarak sudaki polistiren boncuklar ve yoğurt kültüründeki maya hücreleri kullanılmıştır. Bu optik cımbızın özelliklerini belirlemek için sertlik ve yakalama kuvveti, Lazer 1, Lazer 2 ve her iki lazerin aynı anda kullanıldığı durum için Brownian Hareketi yöntemi kullanılarak belirlenmiştir. Optik bileşenlerde yapılan küçük ayarlamalar yakalama kuvvetini etkileyerek Lazer 2'nin yakalama kuvvetinin daha düşük olmasına neden olmuştur. Ek olarak, saçılma ortamının viskozitesinin yakalama kuvveti üzerinde önemli bir etkisi vardır; yoğurt kültürünün daha yüksek viskozitesi, maya hücrelerinin her iki lazerin aynı anda kullanılmasıyla yakalanmasını önlemektedir. İki lazerin paralel olarak kullanılması, bir lazerin parçacıkları yakalamak ve hareket ettirmek için kullanılırken diğerinin birden fazla parçacığı yakalamak için kullanılmasını sağlamaktadır. Farklı çalışma ortamlarında performansı incelenen bu özel tasarım optik cımbız, viskozite ölçümleri, hücre içi incelemeler, gıda mühendisliği ve ilaç dağıtım sistemleri gibi yaşambilim alanlarında uygulanma potansiyeline sahiptir.
- 11 June 2024
- Published by Gumushane University Journal of Science and Technology Institute in Gümüşhane Üniversitesi Fen Bilimleri Enstitüsü Dergisi
Open AccessDüşük maliyetli ve özel tasarım çift ışınlı optik cımbızın performans özellikleri
Bu çalışmada, mikron boyutundaki partikülleri yakalamak ve manipüle etmek için paralel olarak konumlandırılmış iki adet He-Ne lazer (λ=632.8 nm) kullanan düşük bütçeli ve özel tasarlanmış bir optik cımbız geliştirilmiştir. Bu kapsamda örnek olarak sudaki polistiren boncuklar ve yoğurt kültüründeki maya hücreleri kullanılmıştır. Bu optik cımbızın özelliklerini belirlemek için sertlik ve yakalama kuvveti, Lazer 1, Lazer 2 ve her iki lazerin aynı anda kullanıldığı durum için Brownian Hareketi yöntemi kullanılarak belirlenmiştir. Optik bileşenlerde yapılan küçük ayarlamalar yakalama kuvvetini etkileyerek Lazer 2'nin yakalama kuvvetinin daha düşük olmasına neden olmuştur. Ek olarak, saçılma ortamının viskozitesinin yakalama kuvveti üzerinde önemli bir etkisi vardır; yoğurt kültürünün daha yüksek viskozitesi, maya hücrelerinin her iki lazerin aynı anda kullanılmasıyla yakalanmasını önlemektedir. İki lazerin paralel olarak kullanılması, bir lazerin parçacıkları yakalamak ve hareket ettirmek için kullanılırken diğerinin birden fazla parçacığı yakalamak için kullanılmasını sağlamaktadır. Farklı çalışma ortamlarında performansı incelenen bu özel tasarım optik cımbız, viskozite ölçümleri, hücre içi incelemeler, gıda mühendisliği ve ilaç dağıtım sistemleri gibi yaşambilim alanlarında uygulanma potansiyeline sahiptir.
- Open Access
- 20 April 2022
- Published by Elsevier in International Journal of Thermofluids
- Vol. 14
The developing flow characteristics of water - ethylene glycol mixture based Fe3O4 nanofluids in eccentric annular ducts in low temperature applications
- 20 April 2022
- Published by Elsevier in International Journal of Thermofluids
- Vol. 14
Open AccessThe developing flow characteristics of water - ethylene glycol mixture based Fe3O4 nanofluids in eccentric annular ducts in low temperature applications
- 1 January 2021
- Published by Old City Publishing, Inc in High Temperatures-High Pressures
- Vol. 50 (4-5) , 453-466
Volume-independent contact angle prediction
HTHP Home • Issue Contents • Forthcoming Papers Special Issue 20th Symposium of the Korean Society of Thermophysical Properties (KSTP 20) Guest Editor Yeon Suk Choi p. 243 Editorial Yeon Suk Choi F…
- 1 January 2021
- Published by Old City Publishing, Inc in High Temperatures-High Pressures
- Vol. 50 (4-5) , 453-466
Volume-independent contact angle prediction
HTHP Home • Issue Contents • Forthcoming Papers Special Issue 20th Symposium of the Korean Society of Thermophysical Properties (KSTP 20) Guest Editor Yeon Suk Choi p. 243 Editorial Yeon Suk Choi F…
- 9 August 2020
- Published by Taylor & Francis in Science and Technology for the Built Environment
- Vol. 27 (1) , 85-97
Investigation of performance improvement of a household freezer by using natural circulation loop
Growing number of household refrigerators and freezers also increase the overall energy consumption and number of household refrigerators have grown nearly 3% per year. On the other hand, investigations showed that household refrigerators have a significant technical energy saving potential of up to 30-40%. In this study, a single-phase natural circulation loop is considered as a suction line heat exchanger between the high and low pressure sides of conventional refrigeration cycle of a household chest freezer. The potential heat transfer by the single-phase natural circulation loop is studied by a CFD analysis, considering the possible temperature range for refrigeration cycle and geometrical parameters that affect the loop performance. The performance map of this refrigeration cycle is presented for different compressor suction and discharge pressures (LP/HP), discharge temperatures (T2) and different compressor speeds. The results indicate that the most amount of heat transfer is obtained for the single-phase natural circulation loop with aspect ratio of 0.8 and pipe diameter of 6.53 mm. Moreover, the single-phase natural circulation loop provides 11.5% efficiency improvement for the household freezer for maximum compressor speed at lowest T2 and LP/HP. Considering reduction in required compressor work, SPNCmL assisted refrigeration system has a wider operating range.
- 9 August 2020
- Published by Taylor & Francis in Science and Technology for the Built Environment
- Vol. 27 (1) , 85-97
Investigation of performance improvement of a household freezer by using natural circulation loop
Growing number of household refrigerators and freezers also increase the overall energy consumption and number of household refrigerators have grown nearly 3% per year. On the other hand, investigations showed that household refrigerators have a significant technical energy saving potential of up to 30-40%. In this study, a single-phase natural circulation loop is considered as a suction line heat exchanger between the high and low pressure sides of conventional refrigeration cycle of a household chest freezer. The potential heat transfer by the single-phase natural circulation loop is studied by a CFD analysis, considering the possible temperature range for refrigeration cycle and geometrical parameters that affect the loop performance. The performance map of this refrigeration cycle is presented for different compressor suction and discharge pressures (LP/HP), discharge temperatures (T2) and different compressor speeds. The results indicate that the most amount of heat transfer is obtained for the single-phase natural circulation loop with aspect ratio of 0.8 and pipe diameter of 6.53 mm. Moreover, the single-phase natural circulation loop provides 11.5% efficiency improvement for the household freezer for maximum compressor speed at lowest T2 and LP/HP. Considering reduction in required compressor work, SPNCmL assisted refrigeration system has a wider operating range.
- Open Access
Effect of Nanofluid Thermophysical Properties on the Performance Prediction of Single-Phase Natural Circulation Loops
Specifying nanofluids’ thermophysical properties correctly is crucial for correct interpretation of a system’s thermo-hydraulic performance and faster market-uptake of nanofluids. Although, experimental and theoretical studies have been conducted on nanofluids’ thermophysical properties; their order-of-magnitude change is still a matter of debate. This numerical study aims to reveal the sensitivity of single phase natural circulation loops (SPNCL), which are the passive systems widely used in solar thermal and nuclear applications, to thermophysical property inputs by evaluating the effects of measured and predicted nanofluid thermophysical properties on the SPNCL characteristics and performance for the first time. Performance and characteristics of an SPNCL working with water-based-Al2O3 nanofluid (1–3 vol.%) for heating applications is evaluated for different pipe diameters (3–6 mm). The thermal conductivity effect on SPNCL characteristics is found to be limited. However, viscosity affects the SPNCL characteristics significantly for the investigated cases. In this study, Grm ranges are 1.93 × 107–9.45 × 108 for measured thermophysical properties and 1.93 × 107–9.45 × 108 for predicted thermophysical properties. Thermo-hydraulic performance is evaluated by dimensionless heat transfer coefficients which is predicted within an error band of ±7% for both the predicted and measured thermophysical properties of the data. A Nu correlation is introduced for the investigated SPNCL model, which is useful for implementing the SPNCL into a thermal system.
Open AccessEffect of Nanofluid Thermophysical Properties on the Performance Prediction of Single-Phase Natural Circulation Loops
Specifying nanofluids’ thermophysical properties correctly is crucial for correct interpretation of a system’s thermo-hydraulic performance and faster market-uptake of nanofluids. Although, experimental and theoretical studies have been conducted on nanofluids’ thermophysical properties; their order-of-magnitude change is still a matter of debate. This numerical study aims to reveal the sensitivity of single phase natural circulation loops (SPNCL), which are the passive systems widely used in solar thermal and nuclear applications, to thermophysical property inputs by evaluating the effects of measured and predicted nanofluid thermophysical properties on the SPNCL characteristics and performance for the first time. Performance and characteristics of an SPNCL working with water-based-Al2O3 nanofluid (1–3 vol.%) for heating applications is evaluated for different pipe diameters (3–6 mm). The thermal conductivity effect on SPNCL characteristics is found to be limited. However, viscosity affects the SPNCL characteristics significantly for the investigated cases. In this study, Grm ranges are 1.93 × 107–9.45 × 108 for measured thermophysical properties and 1.93 × 107–9.45 × 108 for predicted thermophysical properties. Thermo-hydraulic performance is evaluated by dimensionless heat transfer coefficients which is predicted within an error band of ±7% for both the predicted and measured thermophysical properties of the data. A Nu correlation is introduced for the investigated SPNCL model, which is useful for implementing the SPNCL into a thermal system.
- Open Access
Prediction of Contact Angle of Nanofluids by Single-Phase Approaches
Wettability is the ability of the liquid to contact with the solid surface at the surrounding fluid and its degree is defined by contact angle (CA), which is calculated with balance between adhesive and cohesive forces on droplet surface. Thermophysical properties of the droplet, the forces acting on the droplet, atmosphere surrounding the droplet and the substrate surface are the main parameters affecting on CA. With nanofluids (NF), nanoparticle concentration and size and shape can modify the contact angle and thus wettability. This study investigates the validity of single-phase CA correlations for several nanofluids with different types of nanoparticles dispersed in water. Geometrical parameters of sessile droplet (height of the droplet, wetting radius and radius of curvature at the apex) are used in the tested correlations, which are based on force balance acting on the droplet surface, energy balance, spherical dome approach and empirical expression, respectively. It is shown that single-phase models can be expressed in terms of Bond number, the non-dimensional droplet volume and two geometrical similarity simplexes. It is demonstrated that they can be used successfully to predict CA of dilute nanofluids’ at ambient conditions. Besides evaluation of CA, droplet shape is also well predicted for all nanofluid samples with ±5% error.
Open AccessPrediction of Contact Angle of Nanofluids by Single-Phase Approaches
Wettability is the ability of the liquid to contact with the solid surface at the surrounding fluid and its degree is defined by contact angle (CA), which is calculated with balance between adhesive and cohesive forces on droplet surface. Thermophysical properties of the droplet, the forces acting on the droplet, atmosphere surrounding the droplet and the substrate surface are the main parameters affecting on CA. With nanofluids (NF), nanoparticle concentration and size and shape can modify the contact angle and thus wettability. This study investigates the validity of single-phase CA correlations for several nanofluids with different types of nanoparticles dispersed in water. Geometrical parameters of sessile droplet (height of the droplet, wetting radius and radius of curvature at the apex) are used in the tested correlations, which are based on force balance acting on the droplet surface, energy balance, spherical dome approach and empirical expression, respectively. It is shown that single-phase models can be expressed in terms of Bond number, the non-dimensional droplet volume and two geometrical similarity simplexes. It is demonstrated that they can be used successfully to predict CA of dilute nanofluids’ at ambient conditions. Besides evaluation of CA, droplet shape is also well predicted for all nanofluid samples with ±5% error.
- 1 July 2019
- Published by Elsevier in Journal of Colloid and Interface Science
- Vol. 547, 393-406
The contact angle of nanofluids as thermophysical property
- 1 July 2019
- Published by Elsevier in Journal of Colloid and Interface Science
- Vol. 547, 393-406
The contact angle of nanofluids as thermophysical property
- 18 June 2019
- Published by Taylor & Francis
- p. 59-76
Nanofluid-Based Single-Phase Natural Circulation Loops
Heat transfer problems arise in all scales from macro to micro. Although the heat transfer density has been increasing due to high technology devices and forced convection systems are much more visible, passive cooling solutions are still attracting attention. Natural circulation loops (NCLs) are one of the passive systems which can transfer heat from a hot medium to a cold one by natural convection. They use buoyancy force due to the density gradients instead of mechanical forces for heat transfer. Density gradient can be caused by temperature gradient in single-phase NCLs (SPNCLs) and phase change in two-phase NCLs. SPNCLs have advantages of simplicity, easy control, enhanced safety, and reliability in comparison with two-phase NCLs.
- 18 June 2019
- Published by Taylor & Francis
- p. 59-76
Nanofluid-Based Single-Phase Natural Circulation Loops
Heat transfer problems arise in all scales from macro to micro. Although the heat transfer density has been increasing due to high technology devices and forced convection systems are much more visible, passive cooling solutions are still attracting attention. Natural circulation loops (NCLs) are one of the passive systems which can transfer heat from a hot medium to a cold one by natural convection. They use buoyancy force due to the density gradients instead of mechanical forces for heat transfer. Density gradient can be caused by temperature gradient in single-phase NCLs (SPNCLs) and phase change in two-phase NCLs. SPNCLs have advantages of simplicity, easy control, enhanced safety, and reliability in comparison with two-phase NCLs.