Mallikarjun Sayabanna Holi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Mallikarjun Sayabanna Holi has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Mallikarjunaswamy Shivagangadharaiah Matada
JSS Science and Technology University
7 shared publications Rajesh Raman
Department of Radiodiagnosis, J.S.S. Medical College and Hospital, J.S.S. Academy of Higher Education and Research, Mysuru-570015, India
3 shared publicationsSandhya Dass
2 shared publicationsB.M. Jayadevappa
1 shared publicationDept. Of Ece & Head
1 shared publicationK. Soundara Rajan
VC's Office at Jawaharlal Nehru Technological University, Anantapur(JNTUA), AndhraPradesh, India-515002
1 shared publication
Latest Publications
- Open Access
- 1 June 2026
- Published by Institute of Advanced Engineering and Science in IAES International Journal of Artificial Intelligence (IJ-AI)
- Vol. 15 (3)
Computed tomography imaging radiomics: a novel approach to early-stage non-small cell lung cancer prediction
Radiomics shows promise as non-invasive method for enhancing clinical staging of non-small cell lung cancer (NSCLC) by using quantitative information from computed tomography (CT) scans. This study presents radiomics-based machine learning (ML) approach for staging NSCLC patients into clinical stages I, II, and III based on shape, intensity, and texture features. CT images of 369 NSCLC patients are collected from the cancer imaging archive (TCIA), and extracted 107 radiomic features following image biomarker standardization initiative (IBSI) protocol. The analysis of the sources of variability due to different imaging protocols, using principal component analysis (PCA) and t-distributed stochastic neighbor embedding (t-SNE), showed that these effects were resolved through ComBat harmonization. Recursive feature elimination (RFE) and least absolute shrinkage and selection operator (LASSO) are used for feature selection. Five ML algorithms: logistic regression (LR), support vector machine (SVM), decision tree (DT), random forest (RF), and extreme gradient boosting (XGBoost) were used, with an 80:20 train-test split and 10-fold cross-validation. The classifier is assessed using accuracy, sensitivity, specificity, F1-score, and area under the receiver operating characteristic (AUROC) curve. The RFE and RF classifier combination performed the best with AUROC of 0.9307 and accuracy of 0.8114. This study illustrates the use of radiomics models in non-invasive classification of NSCLC stages and it is role in clinical decision making.
- 1 June 2026
- Published by Institute of Advanced Engineering and Science in IAES International Journal of Artificial Intelligence (IJ-AI)
- Vol. 15 (3)
Open AccessComputed tomography imaging radiomics: a novel approach to early-stage non-small cell lung cancer prediction
Radiomics shows promise as non-invasive method for enhancing clinical staging of non-small cell lung cancer (NSCLC) by using quantitative information from computed tomography (CT) scans. This study presents radiomics-based machine learning (ML) approach for staging NSCLC patients into clinical stages I, II, and III based on shape, intensity, and texture features. CT images of 369 NSCLC patients are collected from the cancer imaging archive (TCIA), and extracted 107 radiomic features following image biomarker standardization initiative (IBSI) protocol. The analysis of the sources of variability due to different imaging protocols, using principal component analysis (PCA) and t-distributed stochastic neighbor embedding (t-SNE), showed that these effects were resolved through ComBat harmonization. Recursive feature elimination (RFE) and least absolute shrinkage and selection operator (LASSO) are used for feature selection. Five ML algorithms: logistic regression (LR), support vector machine (SVM), decision tree (DT), random forest (RF), and extreme gradient boosting (XGBoost) were used, with an 80:20 train-test split and 10-fold cross-validation. The classifier is assessed using accuracy, sensitivity, specificity, F1-score, and area under the receiver operating characteristic (AUROC) curve. The RFE and RF classifier combination performed the best with AUROC of 0.9307 and accuracy of 0.8114. This study illustrates the use of radiomics models in non-invasive classification of NSCLC stages and it is role in clinical decision making.
- 24 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-7
Retrospective methods of Shade correction for Diabetic Retinopathy images
Digital Fundus cameras that provide magnified visibility of the eye fundus are employed for screening of vision-threatening Diabetic Retinopathy (DR) disease. In DR, the retina is damaged because of the fluids leaking from circulatory pathways onto the retina [1]. Prevention and effective treatment of the disease calls for early diagnosis. The visibility of dark lesions such as Microaneurysms (MAs) and dark features such as blood vessels play a major role in assessing retinal image quality. The acquired retinal images are subjected to non-uniform/poor illumination because of which the intensity of the background retina gradually changes across the image [4] and the visibility of MAs is reduced. The peripheral part of the retina is poorly illuminated as compared to the center of the image. This necessitates the equalization of non-uniform illumination for MA detection. The paper focuses on a comparative study of the state of art methodologies for illumination equalization in color fundus images for MA detection. Mean Square Error (MSE), Peak Signal to Noise Ratio (PSNR), and Structural Similarity Index (SSIM) are used as performance parameters for comparison between methods. All shade correction methods are evaluated and assessed on a publicly available e-Ophtha database [21].
- 24 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-7
Retrospective methods of Shade correction for Diabetic Retinopathy images
Digital Fundus cameras that provide magnified visibility of the eye fundus are employed for screening of vision-threatening Diabetic Retinopathy (DR) disease. In DR, the retina is damaged because of the fluids leaking from circulatory pathways onto the retina [1]. Prevention and effective treatment of the disease calls for early diagnosis. The visibility of dark lesions such as Microaneurysms (MAs) and dark features such as blood vessels play a major role in assessing retinal image quality. The acquired retinal images are subjected to non-uniform/poor illumination because of which the intensity of the background retina gradually changes across the image [4] and the visibility of MAs is reduced. The peripheral part of the retina is poorly illuminated as compared to the center of the image. This necessitates the equalization of non-uniform illumination for MA detection. The paper focuses on a comparative study of the state of art methodologies for illumination equalization in color fundus images for MA detection. Mean Square Error (MSE), Peak Signal to Noise Ratio (PSNR), and Structural Similarity Index (SSIM) are used as performance parameters for comparison between methods. All shade correction methods are evaluated and assessed on a publicly available e-Ophtha database [21].
- 30 September 2019
- Published by Blue Eyes Intelligence Engineering and Sciences Engineering and Sciences Publication (BEIESP) in International Journal of Innovative Technology and Exploring Engineering
- Vol. 8 (11) , 620-624
Performance Evaluation of Compressive Sensing Based Compression of Multi-Resolution Ppg Signals Under Wban Environment.
Wireless Body Area Network (WBAN) is a collection of wireless biosensors worn on the body, in which each sensor node is capable of computing and communicating with other nodes or devices like smart phones, Personal Digital Assistant (PDA), hand held devices etc,. The wearable nodes are powered by battery and need to be always functional for continuous remote monitoring of patients which demands that node life time has to be prolonged to the maximum extent. One of the best solutions for this issue is to go for data compression at the node. In this context, Compressive sensing (CS) based energy efficient compression algorithms have been developed and tested for 8 -bit and 10-bit resolution Photoplethesmogram (PPG) signal. Test data have been acquired from normal subjects using Arduino Uno R3. Validation of the algorithm has been carried out by applying on MIMIC-II database and acquired signals. It is found that the CS algorithm reconstruction quality diminishes for low resolution PPG data.
- 30 September 2019
- Published by Blue Eyes Intelligence Engineering and Sciences Engineering and Sciences Publication (BEIESP) in International Journal of Innovative Technology and Exploring Engineering
- Vol. 8 (11) , 620-624
Performance Evaluation of Compressive Sensing Based Compression of Multi-Resolution Ppg Signals Under Wban Environment.
Wireless Body Area Network (WBAN) is a collection of wireless biosensors worn on the body, in which each sensor node is capable of computing and communicating with other nodes or devices like smart phones, Personal Digital Assistant (PDA), hand held devices etc,. The wearable nodes are powered by battery and need to be always functional for continuous remote monitoring of patients which demands that node life time has to be prolonged to the maximum extent. One of the best solutions for this issue is to go for data compression at the node. In this context, Compressive sensing (CS) based energy efficient compression algorithms have been developed and tested for 8 -bit and 10-bit resolution Photoplethesmogram (PPG) signal. Test data have been acquired from normal subjects using Arduino Uno R3. Validation of the algorithm has been carried out by applying on MIMIC-II database and acquired signals. It is found that the CS algorithm reconstruction quality diminishes for low resolution PPG data.
- 5 July 2019
- Published by Bentham Science Publishers Ltd. in Current Medical Imaging
- Vol. 15 (6) , 565-572
Visualization of Cartilage from Knee Joint Magnetic Resonance Images and Quantitative Assessment to Study the Effect of Age, Gender and Body Mass Index (BMI) in Progressive Osteoarthritis (OA)
Background: Osteoarthritis (OA) is a degenerative disease of joint cartilage affecting the elderly people around the world. Visualization and quantification of cartilage is very much essential for the assessment of OA and rehabilitation of the affected people. Magnetic Resonance Imaging (MRI) is the most widely used imaging modality in the treatment of knee joint diseases. But there are many challenges in proper visualization and quantification of articular cartilage using MRI. Volume rendering and 3D visualization can provide an overview of anatomy and disease condition of knee joint. In this work, cartilage is segmented from knee joint MRI, visualized in 3D using Volume of Interest (VOI) approach. Methods: Visualization of cartilage helps in the assessment of cartilage degradation in diseased knee joints. Cartilage thickness and volume were quantified using image processing techniques in OA affected knee joints. Statistical analysis is carried out on processed data set consisting of 110 of knee joints which include male (56) and female (54) of normal (22) and different stages of OA (88). The differences in thickness and volume of cartilage were observed in cartilage in groups based on age, gender and BMI in normal and progressive OA knee joints. Results: The results show that size and volume of cartilage are found to be significantly low in OA as compared to normal knee joints. The cartilage thickness and volume is significantly low for people with age 50 years and above and Body Mass Index (BMI) equal and greater than 25. Cartilage volume correlates with the progression of the disease and can be used for the evaluation of the response to therapies. Conclusion: The developed methods can be used as helping tool in the assessment of cartilage degradation in OA affected knee joint patients and treatment planning.
- 5 July 2019
- Published by Bentham Science Publishers Ltd. in Current Medical Imaging
- Vol. 15 (6) , 565-572
Visualization of Cartilage from Knee Joint Magnetic Resonance Images and Quantitative Assessment to Study the Effect of Age, Gender and Body Mass Index (BMI) in Progressive Osteoarthritis (OA)
Background: Osteoarthritis (OA) is a degenerative disease of joint cartilage affecting the elderly people around the world. Visualization and quantification of cartilage is very much essential for the assessment of OA and rehabilitation of the affected people. Magnetic Resonance Imaging (MRI) is the most widely used imaging modality in the treatment of knee joint diseases. But there are many challenges in proper visualization and quantification of articular cartilage using MRI. Volume rendering and 3D visualization can provide an overview of anatomy and disease condition of knee joint. In this work, cartilage is segmented from knee joint MRI, visualized in 3D using Volume of Interest (VOI) approach. Methods: Visualization of cartilage helps in the assessment of cartilage degradation in diseased knee joints. Cartilage thickness and volume were quantified using image processing techniques in OA affected knee joints. Statistical analysis is carried out on processed data set consisting of 110 of knee joints which include male (56) and female (54) of normal (22) and different stages of OA (88). The differences in thickness and volume of cartilage were observed in cartilage in groups based on age, gender and BMI in normal and progressive OA knee joints. Results: The results show that size and volume of cartilage are found to be significantly low in OA as compared to normal knee joints. The cartilage thickness and volume is significantly low for people with age 50 years and above and Body Mass Index (BMI) equal and greater than 25. Cartilage volume correlates with the progression of the disease and can be used for the evaluation of the response to therapies. Conclusion: The developed methods can be used as helping tool in the assessment of cartilage degradation in OA affected knee joint patients and treatment planning.
- 20 February 2018
- Published by Springer Nature
- p. 528-541
Detection of Menisci Tears in Sports Injured and Pathological Knee Joint Using Image Processing Techniques
- 20 February 2018
- Published by Springer Nature
- p. 528-541
Detection of Menisci Tears in Sports Injured and Pathological Knee Joint Using Image Processing Techniques
- 1 May 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 584-587
Multilayer machine learning algorithm to classify diabetic type on knee dataset
Since last decade, the diabetes risks are increasing in children and adults. Various approaches have been proposed for early detection of the diabetes and prevention on it. Some methods use EMG signals for diabetes classification, due to motion artifacts in the EMG signals during acquisition of signal, these approaches are not able to classify the signal efficiently. To overcome this we propose anew method by considering time domain and frequency domain features of the EMG signals and to perform the classification we use neural network. This method is executed using MATLAB tool and simulation study shows the accuracy of proposed approach is 97.05%.
- 1 May 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 584-587
Multilayer machine learning algorithm to classify diabetic type on knee dataset
Since last decade, the diabetes risks are increasing in children and adults. Various approaches have been proposed for early detection of the diabetes and prevention on it. Some methods use EMG signals for diabetes classification, due to motion artifacts in the EMG signals during acquisition of signal, these approaches are not able to classify the signal efficiently. To overcome this we propose anew method by considering time domain and frequency domain features of the EMG signals and to perform the classification we use neural network. This method is executed using MATLAB tool and simulation study shows the accuracy of proposed approach is 97.05%.
- 1 April 2016
- Published by Wolters Kluwer Health in Journal of Clinical Engineering
- Vol. 41 (2) , 72-82
Classification of Brainstem Auditory Evoked Potentials Using Artificial Neural Network Based on Time and Frequency Domain Features
- 1 April 2016
- Published by Wolters Kluwer Health in Journal of Clinical Engineering
- Vol. 41 (2) , 72-82
Classification of Brainstem Auditory Evoked Potentials Using Artificial Neural Network Based on Time and Frequency Domain Features
- 1 January 2016
- Published by Inderscience Publishers in International Journal of Bioinformatics Research and Applications
- Vol. 12 (1) , 47
Wireless monitoring and analysis of PPG signal for assessment of cardiovascular system in real time
In the present work a simple, non-invasive and portable electro-optical based wireless real-time PPG monitoring system has been developed. The system can be used for monitoring of patient's health status specially those of disabled and suffering from cardiovascular diseases. It records variations in the volume of blood with each heart beat resulting in the form of signal called photoplethysmogram (PPG). System consists of light source and photo-detector packed in the form of probe, fitted to patient's index finger. For remote monitoring of PPG signals, a ZigBee wireless technology is used. The PPG contain rich information about cardiovascular and respiratory systems. From PPG, parameters like pulse rate (PR), average pulse rate (APR), pulse rate variability (PRV) and frequency spectrum were determined for diagnostic purpose. System monitors the patient's health conditions without restricting their movements, hence can be extended beyond hospital limits. Thus, physician can monitor the patient's health status remotely.
- 1 January 2016
- Published by Inderscience Publishers in International Journal of Bioinformatics Research and Applications
- Vol. 12 (1) , 47
Wireless monitoring and analysis of PPG signal for assessment of cardiovascular system in real time
In the present work a simple, non-invasive and portable electro-optical based wireless real-time PPG monitoring system has been developed. The system can be used for monitoring of patient's health status specially those of disabled and suffering from cardiovascular diseases. It records variations in the volume of blood with each heart beat resulting in the form of signal called photoplethysmogram (PPG). System consists of light source and photo-detector packed in the form of probe, fitted to patient's index finger. For remote monitoring of PPG signals, a ZigBee wireless technology is used. The PPG contain rich information about cardiovascular and respiratory systems. From PPG, parameters like pulse rate (PR), average pulse rate (APR), pulse rate variability (PRV) and frequency spectrum were determined for diagnostic purpose. System monitors the patient's health conditions without restricting their movements, hence can be extended beyond hospital limits. Thus, physician can monitor the patient's health status remotely.
- 1 June 2015
- Published by American Scientific Publishers in Journal of Medical Imaging and Health Informatics
- Vol. 5 (3) , 552-560
Knee Joint Menisci Segmentation, Visualization and Quantification Using Seeded Region Growing Algorithm
- 1 June 2015
- Published by American Scientific Publishers in Journal of Medical Imaging and Health Informatics
- Vol. 5 (3) , 552-560
Knee Joint Menisci Segmentation, Visualization and Quantification Using Seeded Region Growing Algorithm
- 11 December 2014
- Published by Springer Nature
- p. 417-425
Quantification and 3D Visualization of Articular Cartilage of Knee Joint Using Image Processing Techniques
- 11 December 2014
- Published by Springer Nature
- p. 417-425
Quantification and 3D Visualization of Articular Cartilage of Knee Joint Using Image Processing Techniques