Su-Ann Chong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Su-Ann Chong has a total of 70 co-authors. Here are the top co-authors by number of shared publications:
- Daniel Rutte
Geologie TU Bergakademie Freiberg Freiberg Germany
3 shared publications - Jonathan Troy Morrell
Los Alamos National Laboratory
3 shared publications Bruce Hannan
2 shared publicationsChristopher Montcalm
2 shared publicationsJason Hayward
2 shared publicationsRichard Riedel
2 shared publications
Latest Publications
- 1 March 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (3)
Scintillator-based Timepix3 detector for neutron spin-echo techniques using intensity modulation
A scintillator-based Timepix3 (TPX3) detector was developed to resolve the high-frequency modulation of a neutron beam in both spatial and temporal domains, as required for neutron spin-echo experiments. In this system, light from a scintillator is manipulated with an optical lens and is intensified using an image intensifier, making it detectable with the TPX3 chip. Two different scintillators, namely, 6LiF:ZnS(Ag) and 6LiI:Eu, were investigated to achieve the high resolution needed for spin-echo modulated small-angle neutron scattering (SEMSANS) and modulation of intensity with zero effort (MIEZE). The methodology for conducting event-mode analysis is described, including the optimization of clustering parameters for both scintillators. The detector with both scintillators was characterized with respect to detection efficiency, spatial resolution, count rate, uniformity, and γ-sensitivity. The 6LiF:ZnS(Ag) scintillator-based detector achieved a spatial resolution of 200 μm and a count rate capability of 1.1 × 105 cps, while the 6LiI:Eu scintillator-based detector demonstrated a spatial resolution of 250 μm and a count rate capability exceeding 2.9 × 105 cps. Furthermore, high-frequency intensity modulations in both spatial and temporal domains were successfully observed, confirming the suitability of this detector for SEMSANS and MIEZE techniques, respectively.
- 1 March 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (3)
Scintillator-based Timepix3 detector for neutron spin-echo techniques using intensity modulation
A scintillator-based Timepix3 (TPX3) detector was developed to resolve the high-frequency modulation of a neutron beam in both spatial and temporal domains, as required for neutron spin-echo experiments. In this system, light from a scintillator is manipulated with an optical lens and is intensified using an image intensifier, making it detectable with the TPX3 chip. Two different scintillators, namely, 6LiF:ZnS(Ag) and 6LiI:Eu, were investigated to achieve the high resolution needed for spin-echo modulated small-angle neutron scattering (SEMSANS) and modulation of intensity with zero effort (MIEZE). The methodology for conducting event-mode analysis is described, including the optimization of clustering parameters for both scintillators. The detector with both scintillators was characterized with respect to detection efficiency, spatial resolution, count rate, uniformity, and γ-sensitivity. The 6LiF:ZnS(Ag) scintillator-based detector achieved a spatial resolution of 200 μm and a count rate capability of 1.1 × 105 cps, while the 6LiI:Eu scintillator-based detector demonstrated a spatial resolution of 250 μm and a count rate capability exceeding 2.9 × 105 cps. Furthermore, high-frequency intensity modulations in both spatial and temporal domains were successfully observed, confirming the suitability of this detector for SEMSANS and MIEZE techniques, respectively.
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
High Data-Rate Neutron-Sensitive Pixelated Detector Using Silicon Photomultiplier
We report on the design and performance of a neutron-sensitive pixelated detector using an array of silicon photomultiplier (SiPM) sensors. The proof-of-concept design consists of an 8 × 8 array of SiPM sensors coupled with an 8 × 8 array of 6 Li-enriched glass scintillator (GS20) cubes. Each scintillator cube, of size 2 mm × 2 mm × 2 mm, is placed directly over each element in the sensor array. Each sensor is read out and processed using a simple comparator for pulse height discrimination. Individual counts are then recorded using a Xilinx ZYNQ-based system on chip. Tests performed at the Double-Axis Diffractometer (2X-C) and the High-Resolution Neutron Powder Diffractometer (PSD) beamlines at Missouri University Research Reactor (MURR) show a linear response of individual sensor element up to 100 kHz over an area of 0.2 cm × 0.2 cm, which is equivalent to 2.5 MHz/cm 2 . The detector efficiency at a neutron wavelength of 4.1 A was measured to be 74.6% relative to the˚ detection efficiency of a 1-inch diameter 10-atm 3 He gas detector. The pixel crosstalk was estimated to be less than 3%. The gamma sensitivity was measured to be 1 × 10 −3 using calibrated 60 Co gamma source at the optimal discriminator setting of the detector.
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
High Data-Rate Neutron-Sensitive Pixelated Detector Using Silicon Photomultiplier
We report on the design and performance of a neutron-sensitive pixelated detector using an array of silicon photomultiplier (SiPM) sensors. The proof-of-concept design consists of an 8 × 8 array of SiPM sensors coupled with an 8 × 8 array of 6 Li-enriched glass scintillator (GS20) cubes. Each scintillator cube, of size 2 mm × 2 mm × 2 mm, is placed directly over each element in the sensor array. Each sensor is read out and processed using a simple comparator for pulse height discrimination. Individual counts are then recorded using a Xilinx ZYNQ-based system on chip. Tests performed at the Double-Axis Diffractometer (2X-C) and the High-Resolution Neutron Powder Diffractometer (PSD) beamlines at Missouri University Research Reactor (MURR) show a linear response of individual sensor element up to 100 kHz over an area of 0.2 cm × 0.2 cm, which is equivalent to 2.5 MHz/cm 2 . The detector efficiency at a neutron wavelength of 4.1 A was measured to be 74.6% relative to the˚ detection efficiency of a 1-inch diameter 10-atm 3 He gas detector. The pixel crosstalk was estimated to be less than 3%. The gamma sensitivity was measured to be 1 × 10 −3 using calibrated 60 Co gamma source at the optimal discriminator setting of the detector.
- Open Access
- 6 September 2019
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 5 (9) , eaaw5526
Boutique neutrons advance 40 Ar/ 39 Ar geochronology
Use of deuteron-deuteron fusion neutrons may substantially improve applicability and accuracy of the 40 Ar/ 39 Ar technique.
- 6 September 2019
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 5 (9) , eaaw5526
Open AccessBoutique neutrons advance 40 Ar/ 39 Ar geochronology
Use of deuteron-deuteron fusion neutrons may substantially improve applicability and accuracy of the 40 Ar/ 39 Ar technique.
- Open Access
- 25 April 2019
- Published by American Physical Society (APS) in Physical Review C
- Vol. 99 (4) , 044612
Possible evidence of nonstatistical properties in the cross sectionThe and cross sections at incident neutron energies between 2.42 and 2.74 MeV were measured using the Berkeley High Flux Neutron Generator. The cross sections for were more than a factor of 3 to 5 less than all of the values in the neutron absorption data libraries, while the cross sections are in reasonable agreement with the data libraries. The measured energy-differential cross section is consistent with a single resonance with a width of 293(46) keV. This result suggests that, despite the high incident neutron energy, any attempt to model cross sections in the vicinity of the shell gap requires a resolved resonance approach rather than a Hauser-Feshbach approach.- 25 April 2019
- Published by American Physical Society (APS) in Physical Review C
- Vol. 99 (4) , 044612
Open AccessPossible evidence of nonstatistical properties in the cross sectionThe and cross sections at incident neutron energies between 2.42 and 2.74 MeV were measured using the Berkeley High Flux Neutron Generator. The cross sections for were more than a factor of 3 to 5 less than all of the values in the neutron absorption data libraries, while the cross sections are in reasonable agreement with the data libraries. The measured energy-differential cross section is consistent with a single resonance with a width of 293(46) keV. This result suggests that, despite the high incident neutron energy, any attempt to model cross sections in the vicinity of the shell gap requires a resolved resonance approach rather than a Hauser-Feshbach approach.