YDYiping P. Du

Yiping P. Du

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Yiping P. Du has a total of 118 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Unsupervised segmentation of dynamic pulmonary MRI using cross-modality adaptation with annotated CT images

    by Zijun Wu, Ziwei Zhang, Zhijun Wang, Zekang Ding, Li Fan, Yiping P. Du

    Purpose Accurate segmentation of lung parenchyma in dynamic pulmonary magnetic resonance imaging (MRI) is required for clinical diagnosis and treatment planning. However, supervised deep learning algorithms rely on annotated datasets, which are scarce for pulmonary MRI. This study aims to leverage existing annotated computed tomography (CT) data to enable unsupervised segmentation of pulmonary MRI. Methods A new framework was proposed for unsupervised segmentation of pulmonary MRI. First, a masked autoencoder is pretrained to learn modality-invariant features. Next, an initial segmenter is trained using labeled CT images, combined with a temporal consistency loss on 4D MR images. The initial segmenter generates predictions for MR images, which are further processed through a select-and-refine pipeline to produce high-quality pseudolabels. Finally, a final segmenter is trained using the pseudolabeled MRI, combined with the temporal consistency constraint. Results The model was trained using 31 unlabeled 4D MR images and 30 labeled CT images, and evaluated on 20 and 12 4D MR images acquired from two different centers. The proposed method achieves accurate and robust segmentation of lung parenchyma and outperforms state-of-the-art cross-modality methods, with Dice scores of 97.75 ± 0.57% and 97.72 ± 0.55%, and average surface distances of 1.80 ± 1.40 mm and 1.34 ± 0.69 mm across the two test sets. Conclusion The proposed method effectively transfers segmentation knowledge from CT to MRI, enabling accurate segmentation of lung parenchyma. By eliminating the dependency on MRI annotations, our technique offers a practical and promising solution for segmentation of dynamic pulmonary MRI.

  • ST-DAGCN: Spatial-Temporal Directed Acyclic Graph Convolutional Networks for End-to-End Joint Effective Connectivity Learning and Resting-State fMRI Classification

    by Rui Yang, Wenrui Dai, Huajun She, Yiping P. Du, Dapeng Wu, Hongkai Xiong

    Building comprehensive brain connectomes has proved of fundamental importance in resting-state fMRI (rs-fMRI) analysis. Based on the foundation of brain network, spatial-temporal-based graph convolutional networks have dramatically improved the performance of deep learning methods in rs-fMRI time series classification. However, existing works either pre-define the brain network as the correlation matrix derived from the raw time series or jointly learn the connectome and model parameters without any topology constraint. These methods could suffer from degraded classification performance caused by the deviation from the intrinsic brain connectivity and lack biological interpretability of demonstrating the causal structure (i.e., effective connectivity) among brain regions. Moreover, most existing methods for effective connectivity learning are unaware of the downstream classification task and cannot sufficiently exploit useful rs-fMRI label information. To address these issues in an end-to-end manner, we model the brain network as a directed acyclic graph (DAG) to discover direct causal connections between brain regions and propose Spatial-Temporal DAG Convolutional Network (ST-DAGCN) to jointly infer effective connectivity and classify rs-fMRI time series by learning brain representations based on nonlinear structural equation model. The optimization problem is formulated into a continuous program and solved with score-based learning method via gradient descent. We evaluate ST-DAGCN on three public rs-fMRI databases. Experiments show that ST-DAGCN outperforms existing models by evident margins in rs-fMRI classification and simultaneously learns meaningful edges of effective connectivity that help understand brain activity patterns and pathological mechanisms in brain disease.


  • Open Access

    Multimodal Location-Dependent Biomechanical Characterization and Numerical Modeling of Inhomogeneous Median Nerve in Carpal Tunnel

    by Lu Yu, Linjing Peng, Jingyi Jia, Yu Wei, Yiping Du, Yaokai Gan, Zhe Xu, Yifei Yao

    This study assessed location-dependent inhomogeneity in the intracarpal median nerve of healthy subjects using a multimodal framework integrating subject-specific finite element analysis (FEA), ultrasound, and diffusion tensor imaging (DTI). Dynamic B-mode ultrasonography tracked segmental nerve displacement during finger flexion in subjects, with axial strain quantified via speckle cross-correlation. Cross-sectional ultrasound measured nerve cross-sectional area and flattening ratio. Twelve subject-specific FEA models analyzed stress distributions in the nerve, while DTI evaluated diffusion tensor of the median nerve indicating microstructural properties. Correlations between biomechanical and microstructural parameters were examined. Results showed that cross-sectional area, axial strain, von Mises stress, maximum principal stress, and frictional anisotropy of the median nerve decreased from the carpal tunnel inlet to outlet. Strong and significant correlations (r>0.8, P<0.05) were found among these parameters. Our findings in healthy individuals suggest that segmental nerve displacement creates localized strain, particularly at the carpal tunnel inlet. These potential biomechanical vulnerabilities could contribute to the initiation or progression of Carpal Tunnel Syndrome, a hypothesis requiring further clinical investigation.


  • Open Access

    Separation of Water Components from Multi-Echo MRI Data Using Deep Learning-Assisted Subspace Modeling

    by Ruihao Liu, Yudu Li, Yue Guan, Ziwen Ke, Shuoyun Feng, Weijun Tang, Yiping P. Du, Yao Li, Zhi-Pei Liang

    MRI data acquired using multi-echo spin-echo or gradient-echo sequences contain "encoded" water signals from various tissue compartments, i.e., myelin, axon, and extracellular space. Accurate separation of these components is desirable for tissue characterization in healthy and diseased states. However, this signal decomposition problem is very challenging because the encoding matrix is highly ill-conditioned and as a result, its solution is often sensitive to noise and practical data perturbations (e.g., B0 field inhomogeneity). This paper presents a new method to address this problem, which synergistically integrates physics-based spatiotemporal priors and machine learning to constrain the variations allowed for each water component while providing flexibility to capture subject- and experiment-dependent signal changes. Specifically, we introduced a probabilistic union-of-subspaces model with pre-learned spectral bases to enforce temporal constraints while incorporating spatial priors derived from deep learning-based image translation. To further accommodate subject- and experiment-specific signal variations, a generalized series model was employed to adapt the pre-learned subspace model to a specific dataset. With the proposed model and learned priors, water separation was done under the Bayesian statistical framework. Numerical simulations and experimental evaluations demonstrated that the proposed method significantly improved the accuracy of the estimated myelin, axonal, and extracellular water components. The new method will enhance the practical utility of multi-component water imaging for basic neuroscience and clinical applications and also provide a useful framework for separating overlapping spatiotemporal signals.

  • Open Access

    Information-Theoretic Analysis of Multimodal Image Translation

    by Ruihao Liu, Yudu Li, Yao Li, Yiping P. Du, Zhi-Pei Liang

    Multimodal image translation has found useful applications in solving several medical imaging problems. In this paper, we presented a systematic analysis of multimodal images and machine learning-based image translation from an information-theoretic perspective. Specifically, we analyzed the amount of mutual information that exists in some commonly used multimodal images. This analysis revealed varying structural correlation across modalities and tissue-dependence of mutual information. We also analyzed the amount of information transferred and gained in multimodal image translation and provided an upper bound on the information gain. Information-theoretic measures were also proposed to assess the effectiveness of an image translator, and the uncertainty associated with image translation. Numerical results were presented to demonstrate the information gain in practical multimodal image translation, and to validate the proposed upper bound on information gain and the translation error predictor. Finally, several potential applications of our analysis results were discussed, including the image denoising and reconstruction using side information generated by image translation. The findings from this study may prove useful for guiding the further development and application of multimodal image translation.


  • A Quadruple-Tuned RF Coil System for ¹H/¹⁹F/²³Na/³¹P Synchronous MR Imaging and Spectroscopy at 3 T

    by Xing Yang, Feng Du, Zekang Ding, Bei Liu, Kai Wang, Liwen Wan, Yiping P. Du, Xiaoliang Zhang, Xin Liu, Hairong Zheng, et al.

    The simultaneous acquisition of biological information at different levels of tumor molecular targets, energy metabolism, ion perturbations and structural function is significant for tumor research, as MRI and MRS are crucial tools for comprehensive characterization of tumor pathology and monitoring tumor treatment response. As critical component of RF signal acquisition, the RF transceivers provide the detection capability of signals. Most of the acquisitions for detecting weak nuclei mainly use double tuned probes or RF coils and multi-tuned coils with limitation. There is currently no reported quadruple-tuned multi-channel RF coil design to support simultaneous imaging of four nuclei for animal studies at 3 T. In this work, we developed an innovative quadruple-tuned multi-channel transceiver coil array for synchronous 1H/19F/23Na/31P MR imaging in animals at 3.0 T, which provided a potential tool for tumor research at different levels of tumor molecular targets, energy metabolism, ion perturbations and structural function in MRI application. In contrast to receive-only RF coils, the proposed RF coil system supports multichannel parallel excitation and parallel reception for all four nuclei (1H, 19F, 23Na, 31P) and enables B1+ shimming to control the transmit field distribution. In order to maximize the SNR for all nuclei, detuning control strategy was innovatively utilized to counteract the electromagnetic interference in the RF system. Bench tests and numerical simulations were conducted to assess the performance of the developed quadruple-tuned RF coil system. The phantom and in vivo imaging experiments were performed on a 3T scanner with multi-nuclear imaging capability to evaluate the practicability of our developed design, where SNR of the quadruple-tuned coil was compared with 1H/19F doubletuned coil array, 23Na /31P single-tuned coil arrays. The results demonstrated that the proposed quadruple-tuned RF coil system possessed high sensitivity and relatively homogeneous RF transmission and reception profiles with the ability to image 1H, 19F, 23Na, and 31P synchronously, which has the potential to simultaneously provide physical, biochemical, functional information for tumor research in addition to structural information.


  • Acquisition Acceleration of Ultra-Low Field MRI With Parallel Imaging and Compressed Sensing in Microtesla Fields

    by Huaiming Wang, Wenlong Feng, Xue Ren, Quan Tao, Liangliang Rong, Yiping P. Du, Hui Dong

    Objective: In recent years, ultra-low field (ULF) magnetic resonance imaging (MRI) has gained widespread attention due to its advantages, such as low cost, light weight, and portability. However, the low signal-to-noise ratio (SNR) leads to a long scan time. Herein, we study the acceleration performance of parallel imaging (PI) and compressed sensing (CS) in different k-space sampling strategies at 0.12 mT. Methods: This study employs phantoms to assess the efficiency of acceleration methods at ULF MRI, in which signals are detected by ultra-sensitive superconducting quantum interference devices (SQUIDs). We compare the performance of fast Fourier transform (FFT), generalized auto-calibrating partially parallel acquisitions (GRAPPA), and eigenvector-based SPIRiT (ESPIRiT) in Cartesian sampling, while also evaluating non-uniform FFT (NUFFT), GRAPPA operator gridding, and ESPIRiT in non-Cartesian sampling. We design a resolution phantom to investigate the effectiveness of these methods in maintaining image resolution. Results: In Cartesian sampling, GRAPPA and ESPIRiT jointly regularized by total variation and ℓ1-norm (TVJℓ1-ESPIRiT) methods reconstructed good-quality phantom images with an acceleration factor of R = 2. In contrast, TVJℓ1-ESPIRiT exhibited improved image quality and much less signal loss even for R = 4. In radial sampling, TVJℓ1-ESPIRiT reduced the acquisition time to 1.69 minutes at R = 4, with a respective improvement of 12.26 dB in peak SNR compared to NUFFT. The resolution phantom imaging showed that the reconstructions by PI and CS maintained the original resolution of 2 mm. Conclusion and significance: This study improves the practicality of ULF MRI at microtesla fields by implementing imaging acceleration with PI and CS in different k-space sampling.


  • Open Access

    Accelerated Free-Breathing Phase Contrast Cardiovascular MRI using Spatial-Temporal Dictionary Learning Neural

    by Sifan Wu, Huajun She, Zhijun Wang, Li Tong, Zhenkui Wang, Yiping Du

    The study presents a novel phase-contrast MRI (PC-MRI) reconstruction framework, employing spatial-temporal dictionary learning neural networks (stDLNN), to tackle the issues of artifacts and noise in undersampled radial acquisitions of dynamic PC images. By integrating dictionary learning and deep learning, the proposed method aims to improve reconstruction accuracy. Comparative results reveal the stDLNN-based approach outperforms existing methods in velocity-encoded image reconstruction and velocity map quality, even at high acceleration rates. This advancement in PC-MRI reconstruction holds promise for real-time imaging, with potential implications for enhancing clinical applications and advancing PC-MRI reconstruction techniques.