JRJosé Rosas-Díaz

José Rosas-Díaz

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


José Rosas-Díaz has a total of 55 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    In vitro comparison of pH, solubility, and radiopacity of two dual-cure resin cements

    by Evelyn Aguirre-Gil, Leonor Castro-Ramirez, José Rosas-Díaz, Enrique Yarasca-Berrocal, José Huamani-Echaccaya, Luis Cervantes-Ganoza, César Cayo-Rojas

    Background: Understanding the properties of dual-cure resin cements is essential for ensuring clinical success. The present study compared the pH, solubility, and radiopacity of the dual-cure resin cements NX3 Nexus ® and Variolink N ® . Methods: This in vitro experimental study prepared 30 standardized dual-cure resin cement discs (8 mm diameter × 1 mm thickness). Discs were equally allocated to two groups ( n = 15) —NX3 Nexus ® and Variolink N ® — and, within each cement, randomly assigned to three subgroups for pH, solubility, and radiopacity testing ( n = 5 per subgroup). The non-parametric Mann–Whitney U test was employed for comparisons of solubility and pH, while the parametric Student’s t-test was employed for radiopacity. A significance level of p < 0.05 was considered. Results: Significant differences were observed between NX3 Nexus and Variolink N when comparing pH ( p = 0.008) and radiopacity ( p = 0.026). Both resin cements showed no differences when comparing solubility ( p = 0.841). Conclusion: Under the present in vitro conditions, NX3 Nexus ® and Variolink N ® demonstrated low solubility and comparable pH. Variolink N ® ’s higher radiopacity may aid radiographic detection of excess cement and marginal assessment; thus, it may be preferred when radiographic evaluation is critical, whereas either cement is appropriate otherwise.

  • Open Access

    Repeatability and reproducibility of a new classification for measuring primary stability of dental implants based on progressive insertion torque value: An analytical observational study

    by J. Rosas-Díaz, N. Córdova-Limaylla, Me. Guerrero, J. Palomino-Zorrilla, R. Álvarez-Medina, C. Cayo-Rojas

    Assessing primary stability is critical to predicting dental implant success, yet existing assessments often rely on subjective judgment. This study presents and validates a classification system based on the progressive insertion torque value (PITV) to provide objective, reproducible parameters for guiding prosthetic loading protocols. An analytical observational study was conducted on 1,250 implant torque-curve interpretations. Primary stability was classified into three types according to final insertion torque (IT): high (50 Ncm), moderate (30 to <50 Ncm), and low (<30 Ncm). Types I and II included four PITV subtypes (A-D), while Type III included six subtypes (A-F) based on curve trajectory patterns. Twenty-five dentists were trained in curve interpretation, and intra- and inter-examiner agreement was assessed using Cohen's and Fleiss' kappa statistics and prevalence- and bias-adjusted kappa (PABAK). Predictive validity was assessed using receiver operating characteristic (ROC) analysis (area under the curve [AUC] with 95% confidence intervals). Calibration (intercept and slope) and the Brier score were also computed. Intraexaminer agreement was almost perfect in both general dentists and implant specialists (k = 0.82-0.95). Interexaminer agreement was also almost perfect (general dentists: k = 0.81; specialists: k = 0.89). Overall agreement was k = 0.84 (p < 0.001). The classification showed moderate predictive discrimination (AUC = 0.69, 95% CI: 0.56-0.81). The classification of primary stability based on the progressive insertion torque value in edentulous maxillary ridges showed high intraexaminer and interexaminer reliability in interpreting torque-time curves. Its clinical utility, predictive performance, and prosthetic loading thresholds were not assessed in this study and warrant prospective evaluation.


  • Open Access

    The Influence of the Degree of Dental Implant Insertion Compression on Primary Stability Measured by Resonance Frequency and Progressive Insertion Torque: In Vitro Study

    by José Rosas-Díaz, Maria Eugenia Guerrero, Nancy Córdova-Limaylla, Maisely Galindo-Gómez, Marco García-Luna, César Cayo-Rojas

    Background: This study aimed to evaluate the primary stability, according to the insertion torque value (ITV) and resonance frequency analysis (RFA), of dental implants placed in standardized blocks of bone quality equivalent to type II-A bone, using three surgical undersized protocols of 0.2 mm, 0.5 mm, and 0.8 mm, considering different dental implant diameters and lengths. Methods: One hundred and twenty dental implants (DIs) of different diameters (3.5, 3.8, 4.5, and 5.0 mm) and lengths (8.5, 10.0, 11.5, 13.0, and 15.0 mm) placed in polyurethane blocks equivalent to type II-A bone, according to the Lekholm and Zarb classification modified by Rosas et al., were examined with three surgical protocols of under-milling of 0.2, 0.5, and 0.8 mm. The ITV and the RFA were the determinants of primary stability, and their respective values were recorded as Ncm and the implant stability quotient (ISQ) immediately after the placement of the DIs. These were evaluated according to each surgical insertion protocol, length, and diameter of the DI under a multivariate analysis model (MANOVA). Statistical significance was set at p < 0.05. Results: It was observed that the average of the ITV was significantly higher when a 0.8 mm under-milling protocol was used (63.2 ± 14.9 Ncm) (p < 0.001). However, the ITV was significantly lower when a 0.2 mm under-milling protocol was used (25.1 ± 8.3 Ncm) (p < 0.001). On the other hand, the ISQ did not present significant differences (p = 0.166) when comparing the 0.2 (67.6 ISQ ± 5.4 ISQ), 0.5 (65.8 ISQ ± 3.4 ISQ), and 0.8 (65.7 ISQ ± 4.0 ISQ) under-milling protocols in the evaluation of the primary stability of the dental implant. The multivariate effect size (ηp2 = 0.639) indicated that the variability detected in the insertion torque and the ISQ, at the same time, was explained by 63.9% (p < 0.001) due only to the compression protocol, while the implant diameter explained this variability by 27.0% (ηp2 = 0.270) (p < 0.001) and the implant length only significantly explained this variability by 12.1% (ηp2 = 0.121) (p = 0.030). Finally, any interaction between the compression protocol, implant diameter, and length did not influence insertion torque variability or the ISQ (p > 0.05). Conclusions: It can be concluded that when the surgical protocol for subpreparation is optimal according to the prepared bone bed, regardless of the diameter or length of the dental implant used, primary stability was assured according to the ITV and the RFA in 63.9%. This finding allows us to recommend carrying out a correct analysis of bone quality in order to subsequently select the most appropriate surgical protocol for the subpreparation of the bone bed to achieve better primary stability of the dental implant.


  • Open Access

    The Importance of Bone Quality Diagnostics in Preventing Displacement of Dental Implants within the Mandibular Body: A Case Report

    by José Rosas-Díaz, Maria Eugenia Guerrero, Maisely Galindo-Gómez, Marco García-Luna, Edwin Espinoza-Figini, César Cayo-Rojas

    Among the immediate complications that can occur after dental implant placement, accidental displacement within the medullary spaces of the mandibular body is a rare clinical situation. This case report describes implant displacements in the posterior mandibular region and emphasizes the importance of assessing bone density and mandibular medullary patterns prior to implant placement according to a new classification by Lekholm and Zarb modified by Rosas et al. The case reports reported three implant displacements in type II bone of the mandibular body, as classified by Lekholm and Zarb. Following the complication, the bone was reclassified as II-B according to the modification by Rosas et al. The implants were extracted from three female patients aged from 37 to 75 years, with only one having a medical history. All complications were treated and resolved without any alteration after implant removal. To reduce the risk of intraoperative complications that affect the primary stability of dental implants, such as implant migration in the mandibular body, it is important to consider factors that may affect the mechanical locking of the implant at the time of placement, such as the pattern and thickness of the bony trabeculae and the size of the medullary spaces in areas of anatomical risk. For this purpose, we recommend using the modified Lekholm and Zarb classification by Rosas et al. This classification considers the trabecular bone biotype, which helps in planning the surgical approach procedure and establishing a regenerative protocol to minimize the risk of complications with the inferior dental nerve.


  • Open Access

    Importance of local and systemic factors in preventing implant displacement in the mandibular body: a scoping review of existing literature

    by José Rosas-Díaz, Maria Eugenia Guerrero, Diana Castillo-Andamayo, Maisely Galindo-Gómez, Marco García-Luna, Luis Cervantes-Ganoza, César Cayo-Rojas

    The aim of this research was to analyse the current literature on displaced dental implants in the mandibular body, including local and systemic variables related to their cause, and to identify the most frequent location. The study conducted a search of three databases (Pubmed, Scopus, and Web of Science) using specific index terms such as ‘dental implant’, ‘displacement’, ‘dislocation’, ‘displaced’, and ‘mandible’. The analysis focused on the direction of displacement and the characteristics of the bone tissue (bone quality, density, and quantity) in cases where dental implants were displaced. A total of 371 articles were obtained. Thirteen of these articles were selected and read in full. To define bone quality, the Lekholm and Zarb classification, modified by Rosas et al., was used. The type II-B bone, which is characterized by thick cortical bone surrounding cancellous bone with extremely wide medullary spaces, presented the largest number of complications. Twenty-two cases were found in which the displacement direction was horizontal. Of these, four were displaced vestibularly, fourteen lingually, and four remained in the center. Additionally, 24 cases presented vertical displacement, with 12 displaced towards the inferior border of the mandible, 9 towards the middle or adjacent to the inferior dental nerve canal, and 3 above the inferior dental nerve canal. The accidental displacement of implants within the mandibular body is associated with various risk factors, including the characteristics of the bony trabeculum and the size of the medullary spaces. It is reasonable to suggest that only an adequate pre-surgical diagnostic evaluation, with the help of high-resolution tomographic images that allow a previous evaluation of these structures, will help to have better control over the other factors, thus minimizing the risk of displacement.


  • Open Access

    Effect of fibrin-rich plasma and collagen sponge on healing of the palatal mucosa

    by R. Alvarez-Medina, Me. Guerrero, Ne. Córdova-Limaylla, Le. López-Llamosas, Jl. Huamaní-Echaccaya, Jj. Palomino-Zorrilla, Jc. Rosas-Díaz

    The purpose was to evaluate the variation in thickness and early healing of the donor area of the palate with the placement of a collagen sponge and the use of fibrin-rich plasma (L-PRF). Thirty patients who required mucogingival surgery treatment were selected and distributed into 2 groups. After obtaining the free palate graft, L-PRF was placed in Group A, and a collagen sponge was placed in Group B. The healing process of the palate was evaluated at 24 hours and 7, 14, 21 and 28 days postsurgery. The thickness of the donor area (palate) was evaluated using an acrylic splint. These measurements were made before and 4 months after surgery. In the collagen sponge group, less gain of the palatal mucosa was observed, with a mean difference of 0.1 ± 0.8 mm (CI: −0.341–0.518) (p=0.691), whereas in the fibrin-rich plasma group, a mean difference of 0.0 ± 0.5 mm (CI: −0.229–0.229) (p=0.934) was found; however, when comparing the gain of the palatal mucosa in both groups, no significant difference was observed (p=0.932). The healing index at 24 hours indicated the presence of clots, on Day 28 vascularisation and total epithelialisation (100.0%), and finally, the collagen sponge group on Day 14 presented 93.3% partial vascularisation of connective tissue and 33.3% L-PRF (p=0.001). There was no statistically significant difference in the thickness of the palatal mucosa after the use of L-PRF and the collagen sponge. Key words:Palate thickness, connective tissue graft, fibrin-rich plasma, collagen sponge, palate healing.


  • Open Access

    Resonance frequency analysis mapping during implant healing using a nanostructured hydroxyapatite surface

    by José Carlos Rosas-Díaz, Violeta Malpartida-Carrillo, Nancy Edith Córdova-Limaylla, Maria Eugenia Guerrero, Jerson Jimmy Palomino-Zorrilla, Luis Adolfo Cervantes-Ganoza, César Félix Cayo-Rojas

    Aim: Stability measured by resonance frequency analysis (RFA) is an important factor to be considered in the success of dental implant treatments, which can be evaluated from the implant stability quotient (ISQ). The aim of the present case series was to map the RFA during healing of implants with nanostructured hydroxyapatite surface to describe the behavior of ISQ values related to individual factors. Materials and Methods: Twenty-three implants were placed in eight patients by conventional surgical protocol, and ISQ values were monitored from the day of implant placement until week 20. To obtain the ISQ values, an Osstell device was used and the placed implants were grouped in proportional amounts to describe the ISQ behavior considering the length (≤10 or >10 mm), the diameter (3.5 or 4.3 mm), the insertion torque (10 mm, diameter 4.3 mm, and insertion torque ≥40 N-cm showed the highest ISQ values. Conclusions: A decrease in the ISQ values of dental implants with nanostructured hydroxyapatite surface was evidenced between weeks 2 and 3 considering length, diameter, insertion torque, and maxillary or mandibular placement site.


  • Open Access

    Repeatability and Reproducibility of a Modified Lekholm and Zarb Bone Quality Classification Based on Cone Beam Computed Tomography: An Observatsion Study

    by José C. Rosas-Díaz, Nancy E. Córdova-Limaylla, Jerson J. Palomino-Zorrilla, Maria E. Guerrero, Rubén Carreteros, Luis A. Cervantes-Ganoza, César F. Cayo-Rojas

    Aim: We propose a modified Lekholm and Zarb classification that considers all possible combinations of cortical and cancellous bone to provide parameters that favor greater repeatability and reproducibility. Materials and Methods: This observational and analytical study consisted of a sample of 50 cone beam computed tomography (CBCT) scans. Two new types (V and VI), three subtypes to type II (II-A, II-B, and II-C), and two subtypes to type III (III-A and III-B) were added to the original bone quality classification. The new types refer to regenerated bone (type V) and bone with some pathology (type VI). The subtypes are described as type II-A: thick cortical surrounding the abundant cancellous bone with sharp trabeculae throughout the image and presence of small and visible medullary spaces; type II-B: thick cortical surrounding the abundant cancellous bone with predominance of diffuse trabeculae in the basal bone and predominant presence of wide and visible medullary spaces; type II-C: thick cortical surrounding the abundant cancellous bone with predominance of very thick and sharp trabeculae in the basal third as well as presence of small and visible medullary spaces; type III-A: thin cortical surrounding the abundant cancellous bone with sharp trabeculae throughout the image and presence of small and visible medullary spaces; type III-B: thin cortical surrounding the abundant cancellous bone with predominance of diffuse trabeculae and presence of diffuse medullary spaces. Five dental specialists were trained in the use of the modified classification and were provided with CBCT-sectioned images of edentulous jaws for classification. Each specialist classified the images twice at a 7-day interval. The strength of intra-examiner and inter-examiner agreement was measured with Cohen’s and Fleiss’ kappa index, respectively. In addition, the agreement between both classifications was analyzed. All data were analyzed at a 95% confidence level, considering a P-value P < 0.05) in all five specialists, with the kappa index [k] ranging from 0.91 [95% confidence interval (CI): 0.82–0.99) to 0.95 (95% CI: 0.89–1.00). Furthermore, substantial inter-examiner concordance (k=0.76; 95% CI: 0.73–0.79) was significant (P < 0.05). Conclusion: The high repeatability and reproducibility of the modified Lekholm and Zarb classification on CBCT suggest its applicability to distinguish between the various combinations of cortical and cancellous bone and help to define treatment appropriately to optimize results.


  • Open Access

    Effect of Abutment Geometry and Luting Agents on the Vertical Marginal Discrepancy of Cast Copings on Implant Abutments: An In Vitro Study

    by Jose Rosas, Frank Mayta-Tovalino, Violeta Malpartida-Carrillo, Arnaldo Munive Degregori, Roman Mendoza, Maria E. Guerrero

    Aim. Vertical marginal discrepancy (VMD) influences the success of implant-supported restorations. However, there is little literature that has investigated the influence of geometry and cementing agent on changes in VMD of metal copings on implant abutments. The objective was to evaluate the effect of the geometry of the abutment and cementing agents on VMD. Methods. Cast copings were cemented on implant abutments customized cylindrical (4, 5.5, and 7 mm) and on hexagonal implant abutments (4 mm) cemented or uncemented molded copings were placed (n = 4, totally 64 samples) with different luting agents. The VMD of the copings were measured in the coping-abutment interface at three reference points using a stereomicroscope. The independent Student’s t test was used for comparison between the two different abutment walls. The post hoc statistical analysis was performed by the Tukey test. Results. There was a significant VMD increase between noncemented and cemented cast copings using different luting agents. Abutment geometry and luting agents significantly influenced the VMD . Cylindrical abutment at 7 mm in height cemented with different luting agent tested showed significantly higher VMD values than cylindrical abutments of 4 mm . Hexagonal abutments with a 4 mm height showed significantly higher VMD values than cylindrical 4 mm abutments using zinc oxide noneugenol and glass ionomer cements . Conclusions. Abutment geometry and luting agents influence the VMD of cast copings cemented on implant abutment. The higher the cylindrical abutment, the greater the VMD, and hexagonal wall abutments promote greater marginal gap.


  • Open Access

    Management of Peri-implant Mucositis of Multiple Osseointegrated Implants Using a Modified Free Gingival Graft “Punch Technique” in the Total Edentulous Area

    by Frank Mayta-Tovalino, José Rosas, Franco Mauricio, Silvia Luza, Daniel Alvitez-Temoche, Cesar Mauricio-Vilchez

    The purpose of this case report was to describe a technique to modify the free gingival graft by perforations within the graft to guarantee a horizontal increase in the keratinized mucosa in the anteroinferior sector of a total edentulous mandible after osseointegration of previously placed dental implants in a hybrid prosthesis protocol. A 71-year-old male underwent free modified gingival graft surgery with perforations at the level of each implant. At 3 months, the mucosa appeared to be healthy and keratinized, especially at a horizontal level around the implants previously diagnosed with mucositis, providing the patient with satisfactory results. Finally, the hybrid prosthesis was cleaned and polished due to the presentation of a hard plate at the level of the abutments. Within the limitations of this case report, further research is needed to evaluate the long-term efficacy of this modification to the free gingival graft.