Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Budi Azhari has a total of 36 co-authors. Here are the top co-authors by number of shared publications:

  • Edwar Yazid

    Research Center of Smart Mechatronics, National Research and Innovation Agency (BRIN)

    6 shared publications
  • Fransisco Danang Wijaya

    Universitas Gadjah Mada

    4 shared publications
  • Aji Nasirohman Pakha

    National Cheng Kung University

    2 shared publications
  • F. Danang Wijaya

    Department of Electrical Engineering, Gadjah Mada University, Yogyakarta

    2 shared publications
  • M. Luthfi Ramadiansyah

    Smart Mechatronics Research Center, National Research and Innovation Agency (BRIN), Jl. Sangkuriang, Dago, Coblong, Bandung, Jawa Barat, Indonesia 40135

    2 shared publications
  • Merry Indahsari Devi

    Smart Mechatronics Research Center, National Research and Innovation Agency (BRIN), Jl. Sangkuriang, Dago, Coblong, Bandung, Jawa Barat, Indonesia 40135

    2 shared publications

Latest Publications

  • Open Access

    Design of switched reluctance motor as actuator in an end-effector-based wrist rehabilitation robot

    by Budi Azhari, Muhammad Fathul Hikmawan, Aditya Sukma Nugraha, Edwar Yazid, Aji Nasirohman Pakha, Catur Hilman Adritya Haryo Bhakti Baskoro, Rahmat Rahmat, Mohamad Luthfi Ramadiansyah

    The non-communicable diseases have become the top cause of global mortality. One of them is stroke, which also become the first cause of disability worldwide. To help rehabilitate the upper extremities function of stroke survivors, a rehabilitation aid robot is developed, also to bridge the gap between patient and medical staff numbers. An end-effector-based rehabilitation robot is one proposed device. In this case, a switched reluctance motor (SRM) can be utilized as the actuator for its simplicity, robustness, high low-speed torque, and low cost. Thus, this paper proposes a design of SRM to be used as the actuator of an end-effector-based wrist rehabilitation robot. The proposed design is made based on the required torque. To extract the outputs, calculation and simulation using finite element magnetic FEMM 4.2 are conducted. The results show that the SRM produces enough torque, according to references. Moreover, rotor tooth width reduction is not preferred, as it increases the negative torque even though it raises the saliency ratio and cuts the mass of the motor.


  • Fabrication and characterization of PZT / PVDF composite films for force sensor applications

    by Suprapto, Yung Ting, Hariyanto Gunawan, Edwar Yazid, Aditya Sukma Nugraha, Budi Azhari, M Luthfi Ramadiansyah, M Fathul Hikmawan, Jubaidah

    This study explored the impact of hot press parameters on lead zirconate titanate (PZT)/poly(vinylidene fluoride) (PVDF) composite films designed for force‐sensing applications. The systematic fraction (PZT/PVDF), pressure, temperature, and time during hot pressing processes are subject to variation. The focus is on the resulting composite film thickness and its subsequent influence on the piezoelectric properties, which are essential for the performance of force sensors. The present study investigated the characteristics and performance of PZT/PVDF composite films with fraction ratios 2/5, 5/5, and 7/3 and hot pressure of 10, 40, and 60 MPa and temperature at 150 °C for 2 h. The characterization of these films was conducted using X‐ray diffraction, Fourier transform infrared spectroscopy, atomic force microscopy, and scanning electron microscopy. The piezoelectric properties ( d 33 and d 31 ) were measured using impact and extraction tests to evaluate the performance of films with applied forces. The results show that the highest piezoelectric coefficients ( d 33 and d 31 ) were determined to be 35.8 and 12.60 pC N −1 , with fraction ratios of 7/3 and 2/5. The study revealed a positive correlation between the PZT/PVDF ratio and sensitivity, indicating that an increase in the ratio leads to an increase in sensitivity. Conversely, a negative relationship was observed between the impact load and the sensor sensitivity, suggesting that an increase in the impact load results in a sensitivity decrease. The results of this work demonstrate the great potential of piezoelectric PZT/PVDF composite films in force sensors for small load applications. © 2024 Society of Chemical Industry.


  • Optimization of Banjo fitting components geometry for pressure drop minimization in the pressure-amplifier system for vehicle suspension piezoelectric energy harvester

    by Muhammad Fathul Hikmawan, Endro Junianto, Edwar Yazid, Budi Azhari, Merry Indahsari Devi, M. Luthfi Ramadiansyah

    Banjo fittings are hydraulic line connection mechanisms that are usually used to connect rigid parts with other flexible parts at high pressure lines. However, Banjo fittings are hydraulic line connection mechanisms that are usually used to connect rigid parts with other flexible parts at high pressure lines. However,

  • Domestic component level assessment of a BLDC motor prototype for EV based on regulations in Indonesia

    by Budi Azhari, Merry Indahsari Devi, Aji Nasirohman Pakha, Muhammad Fathul Hikmawan, Edwar Yazid, M. Luthfi Ramadiansyah

    Brushless DC (BLDC) Motor is a widely employed type of actuator for electric vehicles (EV), because of its performance excellence compared to other types of mot Brushless DC (BLDC) Motor is a widely employed type of actuator for electric vehicles (EV), because of its performance excellence compared to other types of mot

  • Open Access

    Performance of Linear Generator Designs for Direct Drive Wave Energy Converter under Unidirectional Long-Crested Random Waves

    by Budi Azhari, Fransisco Danang Wijaya, Edwar Yazid

    For generating electricity, direct-drive wave energy converters (WECs) with linear permanent magnet generators (LPMGs) have advantages in terms of efficiency, simplicity, and force-to-weight ratio over WEC with rotary generators. However, the converter’s work under approaching-real wave conditions should be investigated. This paper studies the performance of a pico-scale WEC with two different LPMGs under unidirectional long-crested random waves. Different significant wave heights (using data in the Southern Ocean of Yogyakarta, Indonesia) and peak frequencies are tested. The JONSWAP energy spectrum is used to extract the wave elevations, while the MSS toolbox in MATLAB Simulink is employed to solve the floater’s dynamic responses. Next, the translator movements are extracted and combined with the flux distribution from FEMM simulation and analytical calculation, and the output powers are obtained. An experiment is conducted to test the output under constant speed. The results show for both designs, different tested significant wave height values produce higher output powers than peak frequency variation, but there is no specific trend on them. Meanwhile, the peak frequency is inversely proportional to the output power. Elimination of the non-facing events results in increasing output power under both parameters’ variation, with higher significant wave height resulting in a bigger increase. The semi iron-cored LPMG produces lower power loss and higher efficiency.


  • Stator Teeth Model for Optimum Flat Linear Permanent Magnet Generators

    by Budi Azhari, Edwar Yazid

    Direct-drive wave energy converter (WEC) with linear permanent magnet generators (LPMG) has been recognized as an efficient system to convert wave energy to electrical energy. However, it suffers from a significant cogging force during its translator movement. Any attempts to reduce the force should also consider the effects on the electrical output as well as the overall dimension. As teeth salient ends affect the magnetic flux flow, its configuration can impact the cogging force but also induced voltage. Hence, this paper presents several design alternatives of teeth salient ends’ shape to achieve optimum cogging force and output voltage without changing the overall size. The voltage and cogging force from different models are extracted by using finite element magnetic-based simulation and analytical calculation. The results show that flat, outward-trapezoid, and outward-quarter rounded salient end models bring the optimum induced voltage and cogging force.

  • Dynamic Inductance Simulation of a Linear Permanent Magnet Generator Under Different Magnet Configurations

    by Budi Azhari, Edwar Yazid, Merry Indahsari Devi

    Recently, some innovations have been applied to the linear permanent magnet generator (LPMG). They are including the introduction of high-remanence rare-earth magnets and the use of different magnet configurations. However, these actions also affect the flow and distribution of the magnetic flux. Under the load condition, the load current will also generate reverse flux. The flux resultant then affects the coil parameters; the significant one is the coil inductance. Since it is influential to the output voltage and output power profiles, the impact study of the permanent magnet settings under load condition is essential. Hence this paper presents the inductance profile study of the LMPG with different magnet configurations. After presenting the initial designs, several magnet settings including the material and configuration were varied. Finite element magnetic simulation and analytical calculations were then performed to obtain the inductance profile of the LPMG. The results show that the inductance value varies with change in load current and magnet position. The different magnet materials (SmCo 30 and N35) do not significantly affect the inductance. Meanwhile, different magnet configuration (radial, axial, halbach) results in different inductance trends.


  • Open Access

    Quasi-flat linear PM generator optimization using simulated annealing algorithm for WEC in Indonesia

    by Budi Azhari, Fransisco Danang Wijaya

    Linear permanent magnet generator (LPMG) is an essential component in recent wave energy converter (WEC) which exploits wave’s heave motion. It could be classified into tubular-type, flat-tricore type, and quasi-flat type. In previous researches, these three models have been studied and designed for pico-scale WEC. Design optimization has further been conducted for flat-tricore LPMG, by using simulated annealing (SA) algorithm. It modified some parameters to minimize the resulted copper loss. This paper aims to optimize a quasi-flat LPMG design by applying SA algorithm. The algorithm would readjust the initial LPMG parts dimension. Then, the output of the optimized design would be analyzed and compared. The results showed that the optimization could reduce the copper loss by up to 73.64 % and increase the efficiency from 83.2 % to 95.57 %. For various load resistances, the optimized design also produces larger efficiency. However, the optimized design has a larger size and produces larger cogging force than the initial design.


  • Performance of Wave Energy Converter using Linear Permanent Magnet Generator under Regular Wave Condition

    by Budi Azhari, Edwar Yazid

    This paper analyzes the performance of point absorber wave energy converter (WEC) system using linear permanent magnet generator (LPMG) under regular wave condition. First, a WEC design was modeled. It consists of a floater as wave's mechanical energy capturer, coupled to an LPMG as power take-off system. Then, operation of the WEC system was simulated. In this case, parametric study was carried out to analyze work of the WEC system under selected wave scenario. Magnitude of some wave parameters including its amplitude, frequency, and wavelength were successively varied, as their particular influences toward output power of the system would be investigated. During each variation, resulted flux linkage from LPMG operations were obtained from simulation using finite element software of FEMM. Later, output electrical power of the LPMG could be analytically calculated and presented. The results show that the wave amplitude is directly proportional to operation speed but is inversely proportional to output continuity. In this case, large wave amplitude produces larger but disjointed output power, while small amplitude results smaller but continuous output power. Moreover, the wave frequency determines magnitude and output power spectrum -or sum of output power during certain time interval-, in positive relation. On the other hand, the wavelength is inversely proportional to the wave frequency, so it has opposite relation to the output power spectrum. However, for equal frequency, the wavelength only affects phase shift of the output power.


  • Performance Analysis of Stand-alone Axial Flux Permanent Magnet Generator Connected to Inductive-load

    by Ketut Wirtayasa, Pudji Irasari, Muhammad Kasim, Puji Widiyanto, Muhammad Fathul Hikmawan, Budi Azhari

    Electricity is one of the most important sources of energy in the world. Its use is increasing rapidly for home appliances and industrial apparatus to support every activity in both developed and developing countries. Small-scale, distributed and autonomous power system are all developed in concern about the energy conservation as well as environmental problems. The effect of the home appliances and industrial apparatus which are classified as inductive-loads causes the terminal voltage of the generator to decrease significantly. This paper describes the performance analysis of the generator by using the analytical method when the generator is connected to the inductive-loads. To maintain the voltage regulation not exceed 10% under the influence of the inductive-loads, the designer of the generator must calculate the performance of the generator first before it will be made. The analysis results show that the generator is in good condition when supply the inductive-load at its rated value.