Márcio de Castro Ferreira
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Márcio de Castro Ferreira has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Marcelo Seiji Kubota
Departamento de Ortopedia e Traumatologia, Escola Paulista de Medicina, Universidade Federal de São Paulo, São Paulo, SP, Brasil
6 shared publications - Carlos Eduardo da Silveira Franciozi
Departamento de Ortopedia e Traumatologia, Escola Paulista de Medicina, Universidade Federal de São Paulo, São Paulo, SP, Brasil
5 shared publications - Enzo Salviato Mameri
Departamento de Ortopedia, Escola Paulista de Medicina Universidade Federal de São Paulo São Paulo Brazil
5 shared publications - Marcus Vinicius Malheiros Luzo
Grupo de Cirurgia do Joelho, Departamento de Ortopedia e Traumatologia, Escola Paulista de Medicina, Universidade Federal de São Paulo, São Paulo, SP, Brasil
5 shared publications - Leonardo Augusto Melo de Andrade
Universidade Federal de São Paulo, São Paulo, SP, Brazil
2 shared publications - Luiz Felipe Morlin Ambra
Grupo de Cirurgia do Joelho, Departamento de Ortopedia e Traumatologia, Escola Paulista de Medicina, Universidade Federal de São Paulo, São Paulo, SP, Brasil
2 shared publications
Latest Publications
- Open Access
- 19 January 2026
- Published by Science Publishing Group in Advances in Surgical Sciences
- Vol. 14 (1) , 1-9
Epidemiological Profile of Hysterectomies Within the Public Health System Across Different Regions of Brazil Between 2013 and 2023
Objective: To evaluate the assistive care profile of hysterectomies, including the average length of hospital stay, average cost per procedure, and mortality rate among the five Brazilian regions. Methods: A total of 740,528 procedures were selected, encompassing the number of hospitalizations, average procedure cost, average length of stay, and mortality rate for total, subtotal, vaginal, puerperal, and videolaparoscopic hysterectomies performed in each unit of the Federation between January 2013 and December 2023. Results: Total hysterectomy was the most prevalent (78.30%), while puerperal hysterectomy was the least prevalent (0.80%). The Northeast region performed the most hysterectomies (42.6%), and the Central-West region performed the fewest (9.20%). Puerperal hysterectomy had the longest hospital stay (5.1 days), the highest mortality rate (567.15/10,000), and the highest average cost (R$1,504.00). Videolaparoscopic hysterectomy was of low prevalence, despite being the least invasive, having the lowest mortality rate (2.91/10,000), and the shortest length of stay (2.30 days). It was the second procedure with the lowest average cost (R$624.00), preceded by vaginal hysterectomy (R$597.00). Conclusion: The region with the highest number of procedures was the Northeast, with total hysterectomy being the most prevalent type across Brazil. Puerperal hysterectomy presented the longest average length of stay, the highest average cost, and the highest mortality rate, and was most prevalent in the Southeast region. Videolaparoscopic hysterectomy had the shortest average length of stay and the lowest mortality rate.
- 19 January 2026
- Published by Science Publishing Group in Advances in Surgical Sciences
- Vol. 14 (1) , 1-9
Open AccessEpidemiological Profile of Hysterectomies Within the Public Health System Across Different Regions of Brazil Between 2013 and 2023
Objective: To evaluate the assistive care profile of hysterectomies, including the average length of hospital stay, average cost per procedure, and mortality rate among the five Brazilian regions. Methods: A total of 740,528 procedures were selected, encompassing the number of hospitalizations, average procedure cost, average length of stay, and mortality rate for total, subtotal, vaginal, puerperal, and videolaparoscopic hysterectomies performed in each unit of the Federation between January 2013 and December 2023. Results: Total hysterectomy was the most prevalent (78.30%), while puerperal hysterectomy was the least prevalent (0.80%). The Northeast region performed the most hysterectomies (42.6%), and the Central-West region performed the fewest (9.20%). Puerperal hysterectomy had the longest hospital stay (5.1 days), the highest mortality rate (567.15/10,000), and the highest average cost (R$1,504.00). Videolaparoscopic hysterectomy was of low prevalence, despite being the least invasive, having the lowest mortality rate (2.91/10,000), and the shortest length of stay (2.30 days). It was the second procedure with the lowest average cost (R$624.00), preceded by vaginal hysterectomy (R$597.00). Conclusion: The region with the highest number of procedures was the Northeast, with total hysterectomy being the most prevalent type across Brazil. Puerperal hysterectomy presented the longest average length of stay, the highest average cost, and the highest mortality rate, and was most prevalent in the Southeast region. Videolaparoscopic hysterectomy had the shortest average length of stay and the lowest mortality rate.
- Open Access
- 1 August 2025
- Published by Georg Thieme Verlag KG in Revista Brasileira de Ortopedia
- Vol. 60 (04) , 001-016
Análise antropométrica dos implantes nacionais e importados de artroplastia total de joelho na população brasileira
Resumo: Avaliar a conformidade anatômica de 25 implantes de artroplastia total de joelho (ATJ) à morfologia de joelhos na população brasileira feminina e masculina. Foram analisados 500 exames de ressonância de joelhos de 250 mulheres e 250 homens. As medidas anteroposterior (AP) e mediolateral (ML) dos fêmures, tíbias, e implantes foram tomadas a fim de obter correspondência morfológica. As divergências médias das medidas AP e ML entre as morfologias articulares e os implantes analisados foram as seguintes: fêmures femininos 4,48 mm; fêmures masculinos 4,89 mm; tíbia feminina 3,63 mm; e tíbia masculina 6,11 mm. Os implantes com melhor adaptação AP versus ML foram: Medacta Sphere para o fêmur feminino; Stryker Triathlon para fêmur o masculino; Smith & Nephew Legion para tíbia feminina; e Zimmer Persona para a tíbia masculina. Na comparação da melhor relação de implantes femorais e tibiais para o sexo feminino, observou-se que o United Orthopedic U2 apresentou a melhor pontuação estatística, seguido dos implantes Aesculap Columbus e Smith & Nephew Legion. Para os homens, o melhor escore foi encontrado no Zimmer Persona, Microport Advance e Smith & Nephew Legion. A pior relação feminina foi com o Peter Brehm BPK-S, e a masculina, com o Orthovasive Indus. Os implantes estudados foram satisfatórios para a cobertura óssea articular dos joelhos de brasileiros de ambos os sexos submetidos à ATJ. No entanto, também foram encontrados resultados com diferenças maiores do que 10 mm na maioria dos implantes. Isso ressalta a necessidade de atenção dos cirurgiões para realizar um bom planejamento para a escolha dos implantes. Demonstrou-se que os implantes importados eram mais customizáveis do que os nacionais na população brasileira.
- 1 August 2025
- Published by Georg Thieme Verlag KG in Revista Brasileira de Ortopedia
- Vol. 60 (04) , 001-016
Open AccessAnálise antropométrica dos implantes nacionais e importados de artroplastia total de joelho na população brasileira
Resumo: Avaliar a conformidade anatômica de 25 implantes de artroplastia total de joelho (ATJ) à morfologia de joelhos na população brasileira feminina e masculina. Foram analisados 500 exames de ressonância de joelhos de 250 mulheres e 250 homens. As medidas anteroposterior (AP) e mediolateral (ML) dos fêmures, tíbias, e implantes foram tomadas a fim de obter correspondência morfológica. As divergências médias das medidas AP e ML entre as morfologias articulares e os implantes analisados foram as seguintes: fêmures femininos 4,48 mm; fêmures masculinos 4,89 mm; tíbia feminina 3,63 mm; e tíbia masculina 6,11 mm. Os implantes com melhor adaptação AP versus ML foram: Medacta Sphere para o fêmur feminino; Stryker Triathlon para fêmur o masculino; Smith & Nephew Legion para tíbia feminina; e Zimmer Persona para a tíbia masculina. Na comparação da melhor relação de implantes femorais e tibiais para o sexo feminino, observou-se que o United Orthopedic U2 apresentou a melhor pontuação estatística, seguido dos implantes Aesculap Columbus e Smith & Nephew Legion. Para os homens, o melhor escore foi encontrado no Zimmer Persona, Microport Advance e Smith & Nephew Legion. A pior relação feminina foi com o Peter Brehm BPK-S, e a masculina, com o Orthovasive Indus. Os implantes estudados foram satisfatórios para a cobertura óssea articular dos joelhos de brasileiros de ambos os sexos submetidos à ATJ. No entanto, também foram encontrados resultados com diferenças maiores do que 10 mm na maioria dos implantes. Isso ressalta a necessidade de atenção dos cirurgiões para realizar um bom planejamento para a escolha dos implantes. Demonstrou-se que os implantes importados eram mais customizáveis do que os nacionais na população brasileira.
- Open Access
- 1 August 2025
- Published by Georg Thieme Verlag KG in Revista Brasileira de Ortopedia
- Vol. 60 (04) , 001-016
Anthropometric Analysis of Brazilian and Imported Total Knee Arthroplasty Implants in the Brazilian Population
To evaluate the anatomical conformity of 25 total knee arthroplasty (TKA) implants to the knee morphology of the Brazilian female and male population. We analyzed 500 magnetic resonance imaging (MRI) scans of knees from 250 women and 250 men. We collected data on anteroposterior (AP) and mediolateral (ML) measurements of femurs, tibias, and implants to assess their morphological correspondence. The mean AP versus ML divergence between joint morphologies and the implants was as follows: 4.48 mm for female femurs; 4.89 mm for male femurs; 3.63 mm for female tibias; and 6.11 mm for male tibias. The implants with the best AP versus ML adaptation were: Medacta Sphere for female femurs; Stryker Triathlon for male femurs; Smith & Nephew Legion for female tibias; and Zimmer Persona for male tibias. When comparing the best femoral and tibial implant ratios for female subjects, the United Orthopedic U2 presented the best statistical score, followed by the Aesculap Columbus and Smith &Nephew Legion implants. For male patients, the implants with the highest scores were the Zimmer Persona, the Microport Advance, and the Smith & Nephew Legion. The worst ratios were found in the Peter Brehm BPK-S for female individuals and the Orthovasive Indus for male subjects. The implants studied presented satisfactory results for bone coverage of the knees of Brazilian subjects of both genders undergoing TKA. However, we also found differences higher than 10 mm in most implants. This finding highlights that surgeons must carefully plan the TKA during implant selection. Imported implants proved to be more customizable than Brazilian ones in this population.
- 1 August 2025
- Published by Georg Thieme Verlag KG in Revista Brasileira de Ortopedia
- Vol. 60 (04) , 001-016
Open AccessAnthropometric Analysis of Brazilian and Imported Total Knee Arthroplasty Implants in the Brazilian Population
To evaluate the anatomical conformity of 25 total knee arthroplasty (TKA) implants to the knee morphology of the Brazilian female and male population. We analyzed 500 magnetic resonance imaging (MRI) scans of knees from 250 women and 250 men. We collected data on anteroposterior (AP) and mediolateral (ML) measurements of femurs, tibias, and implants to assess their morphological correspondence. The mean AP versus ML divergence between joint morphologies and the implants was as follows: 4.48 mm for female femurs; 4.89 mm for male femurs; 3.63 mm for female tibias; and 6.11 mm for male tibias. The implants with the best AP versus ML adaptation were: Medacta Sphere for female femurs; Stryker Triathlon for male femurs; Smith & Nephew Legion for female tibias; and Zimmer Persona for male tibias. When comparing the best femoral and tibial implant ratios for female subjects, the United Orthopedic U2 presented the best statistical score, followed by the Aesculap Columbus and Smith &Nephew Legion implants. For male patients, the implants with the highest scores were the Zimmer Persona, the Microport Advance, and the Smith & Nephew Legion. The worst ratios were found in the Peter Brehm BPK-S for female individuals and the Orthovasive Indus for male subjects. The implants studied presented satisfactory results for bone coverage of the knees of Brazilian subjects of both genders undergoing TKA. However, we also found differences higher than 10 mm in most implants. This finding highlights that surgeons must carefully plan the TKA during implant selection. Imported implants proved to be more customizable than Brazilian ones in this population.
- Open Access
- 1 August 2025
- Published by Georg Thieme Verlag KG in Revista Brasileira de Ortopedia
- Vol. 60 (04) , 001-005
Determination of Knee Joint Line Positioning by Femoral Bicondylar and Epicondylar Distances in the Brazilian Population
To determine the positioning of the knee joint line height based on anatomical references, that is, the distance of the femoral condylar bicortical axis and the medial and lateral epicondylar distances in the Brazilian population. We analyzed 500 magnetic resonance imaging tests of the knees of 250 women and 250 men to measure the condylar bicortical axis (CBA) and the distance of the joint height to the medial epicondyle (MED) and to the lateral epicondyle (LED). The mean age of the patients was 50.91 years old, with a standard deviation (SD) of ± 14.76. The mean CBA distance was 72.11 ± 5.93 mm. The mean MED and LED values were 33.39 ± 3.50 mm and 26.32 ± 4.08 mm, respectively. The formulas to estimate the distance of the joint line from the medial and lateral epicondyles were MED = 0.4618 x CBA and LED = 0.3615 x CBA for male subjects and MED = 0.4653 x CBA and LED = 0.3767 x CBA for female subjects using a 95% confidence interval. The distance to the femoral CBA can be a reference for determining the joint line positioning from the distances of the medial and lateral femoral epicondyles.
- 1 August 2025
- Published by Georg Thieme Verlag KG in Revista Brasileira de Ortopedia
- Vol. 60 (04) , 001-005
Open AccessDetermination of Knee Joint Line Positioning by Femoral Bicondylar and Epicondylar Distances in the Brazilian Population
To determine the positioning of the knee joint line height based on anatomical references, that is, the distance of the femoral condylar bicortical axis and the medial and lateral epicondylar distances in the Brazilian population. We analyzed 500 magnetic resonance imaging tests of the knees of 250 women and 250 men to measure the condylar bicortical axis (CBA) and the distance of the joint height to the medial epicondyle (MED) and to the lateral epicondyle (LED). The mean age of the patients was 50.91 years old, with a standard deviation (SD) of ± 14.76. The mean CBA distance was 72.11 ± 5.93 mm. The mean MED and LED values were 33.39 ± 3.50 mm and 26.32 ± 4.08 mm, respectively. The formulas to estimate the distance of the joint line from the medial and lateral epicondyles were MED = 0.4618 x CBA and LED = 0.3615 x CBA for male subjects and MED = 0.4653 x CBA and LED = 0.3767 x CBA for female subjects using a 95% confidence interval. The distance to the femoral CBA can be a reference for determining the joint line positioning from the distances of the medial and lateral femoral epicondyles.
- Open Access
- 1 August 2025
- Published by Georg Thieme Verlag KG in Revista Brasileira de Ortopedia
- Vol. 60 (04) , 001-005
Determinação do posicionamento da linha articular do joelho por meio das distâncias bicondilar femoral e epicondilar na população brasileira
Resumo: Determinar o posicionamento da altura da linha articular de joelhos a partir das referências anatômicas da distância do eixo bicortical condilar femoral e das distâncias epicondilares medial e lateral na população brasileira. Foram analisados 500 exames de ressonância magnética de joelhos de 250 mulheres e 250 homens submetidos às mensurações das medidas do eixo bicortical condilar (EBC), da distância da altura articular do epicôndilo medial (DEM) e da distância do epicôndilo lateral (DEL). A média de idade dos pacientes analisados foi de 50,91 ± 14,76 anos. A distância média do EBC foi 72,11 ± 5,93mm. As DEMs e DELs médias foram 33,39 ± 3,50mm e 26,32 ± 4,08mm. As fórmulas encontradas para estimar a distância da linha articular a partir do epicôndilo medial e lateral nos homens foram DEM = 0,4618 x EBC e DEL = 0,3615 x EBC e, nas mulheres, DEM = 0,4653 x EBC e DEL = 0,3767 x EBC para intervalo de confiança de 95%. A distância do EBC femoral pode ser usada como referência para a determinação do posicionamento da linha articular a partir das distâncias dos epicôndilos femorais medial e lateral.
- 1 August 2025
- Published by Georg Thieme Verlag KG in Revista Brasileira de Ortopedia
- Vol. 60 (04) , 001-005
Open AccessDeterminação do posicionamento da linha articular do joelho por meio das distâncias bicondilar femoral e epicondilar na população brasileira
Resumo: Determinar o posicionamento da altura da linha articular de joelhos a partir das referências anatômicas da distância do eixo bicortical condilar femoral e das distâncias epicondilares medial e lateral na população brasileira. Foram analisados 500 exames de ressonância magnética de joelhos de 250 mulheres e 250 homens submetidos às mensurações das medidas do eixo bicortical condilar (EBC), da distância da altura articular do epicôndilo medial (DEM) e da distância do epicôndilo lateral (DEL). A média de idade dos pacientes analisados foi de 50,91 ± 14,76 anos. A distância média do EBC foi 72,11 ± 5,93mm. As DEMs e DELs médias foram 33,39 ± 3,50mm e 26,32 ± 4,08mm. As fórmulas encontradas para estimar a distância da linha articular a partir do epicôndilo medial e lateral nos homens foram DEM = 0,4618 x EBC e DEL = 0,3615 x EBC e, nas mulheres, DEM = 0,4653 x EBC e DEL = 0,3767 x EBC para intervalo de confiança de 95%. A distância do EBC femoral pode ser usada como referência para a determinação do posicionamento da linha articular a partir das distâncias dos epicôndilos femorais medial e lateral.
- Open Access
- 16 January 2025
- Published by Georg Thieme Verlag KG in Revista Brasileira de Ortopedia
- Vol. 60 (01) , 001-007
Morfologia do fêmur distal em uma população brasileira: Desafiando o uso universal de 3° de rotação externa
Resumo: Objetivo Avaliar, em uma população brasileira, o ângulo de rotação externa entre o eixo transepicondilar (ETE) e o eixo condilar posterior (ECP), a fim de estipular se o uso universal de 3° de rotação externa do componente femoral é apropriado neste grupo de pacientes na artroplastia total do joelho (ATJ). Métodos O ângulo de rotação externa foi medido em 167 imagens de ressonância magnéticas utilizando-se 4 métodos diferentes para o ECP, de acordo com os pontos de referências posteriores: medida A – proeminências condrais; medida B – proeminências ósseas; medida C – proeminências ósseas lateral e condral medial; e medida D – proeminências condral lateral e óssea medial. As medidas obtidas foram comparadas estatisticamente com os valores tradicionais de rotação externa de 3° empregados na ATJ. Resultados As médias do ângulo de rotação externa para as medidas A,B,C,D foram de 5,44° ± 2,39°, 4,94° ± 2,10°, 8,56° ± 2° e 2,33° ± 2°, respectivamente. Todos os métodos de medição resultaram em diferenças significativas em relação ao valor universal de 3° (p > 0,0001). Diferenças estatísticas foram encontradas em todas as comparações intergrupos entre os métodos de medição (p > 0,0001), exceto na comparação entre as medidas A e B (p = 0,1614). Conclusão Utilizando um ponto de referência condral ou ósseo para o ECP, o ETE na população brasileira estudada apresentou aproximadamente 5° de rotação externa. A rotação tradicional do componente femoral de 3° em relação ao ECP pode ser insuficiente na população brasileira, sobretudo no joelho valgo. Assim, enfatizamos a importância de uma abordagem individualizada para alcançar o alinhamento rotacional ideal dos componentes na ATJ.
- 16 January 2025
- Published by Georg Thieme Verlag KG in Revista Brasileira de Ortopedia
- Vol. 60 (01) , 001-007
Open AccessMorfologia do fêmur distal em uma população brasileira: Desafiando o uso universal de 3° de rotação externa
Resumo: Objetivo Avaliar, em uma população brasileira, o ângulo de rotação externa entre o eixo transepicondilar (ETE) e o eixo condilar posterior (ECP), a fim de estipular se o uso universal de 3° de rotação externa do componente femoral é apropriado neste grupo de pacientes na artroplastia total do joelho (ATJ). Métodos O ângulo de rotação externa foi medido em 167 imagens de ressonância magnéticas utilizando-se 4 métodos diferentes para o ECP, de acordo com os pontos de referências posteriores: medida A – proeminências condrais; medida B – proeminências ósseas; medida C – proeminências ósseas lateral e condral medial; e medida D – proeminências condral lateral e óssea medial. As medidas obtidas foram comparadas estatisticamente com os valores tradicionais de rotação externa de 3° empregados na ATJ. Resultados As médias do ângulo de rotação externa para as medidas A,B,C,D foram de 5,44° ± 2,39°, 4,94° ± 2,10°, 8,56° ± 2° e 2,33° ± 2°, respectivamente. Todos os métodos de medição resultaram em diferenças significativas em relação ao valor universal de 3° (p > 0,0001). Diferenças estatísticas foram encontradas em todas as comparações intergrupos entre os métodos de medição (p > 0,0001), exceto na comparação entre as medidas A e B (p = 0,1614). Conclusão Utilizando um ponto de referência condral ou ósseo para o ECP, o ETE na população brasileira estudada apresentou aproximadamente 5° de rotação externa. A rotação tradicional do componente femoral de 3° em relação ao ECP pode ser insuficiente na população brasileira, sobretudo no joelho valgo. Assim, enfatizamos a importância de uma abordagem individualizada para alcançar o alinhamento rotacional ideal dos componentes na ATJ.
- Open Access
- 1 January 2024
- Published by FapUNIFESP (SciELO) in Acta Ortopedica Brasileira
- Vol. 32 (1) , e269506
BENEFITS OF A CLINICAL PATHWAY IN TOTAL KNEE ARTHROPLASTY
Objective: Demonstrate whether a multiprofessional Clinical Pathway Program in Total Knee Arthroplasty (CPPA) contributesto optimizing hospital care. Method: Retrospective study of medical data of care indicators in 310 patients divided into two groups: A- who underwent arthroplasty in the last biennium before the introduction of the CPPA (n=144) and group B- who underwent TKA in the biennium after the introduction of the CPPA (n=166). Results: Postoperative showed a significant difference in favor of group B over group A for hospitalization time in days 4.33 ± 2.79 and 5.4 ± 1.67 (p<0.001), time of prophylactic antibiotic in hours 28.13 ± 33.77 and 81.49 ± 40.91 (p<0.001), referral to the intensive care unit 40.9% and 73.4% (p<0.001), initiation of thromboprophylaxis within 24 hours 97.9% and 82.5% (p<0.001), use of elastic stockings and/or intermittent compression prescribed for thromboprophylaxis 89.5% and 31.2% (p<0.001), initiation of rehabilitation within 24 hours 90.1% and 66.1% (p<0.001), readmissions within 30 days 4.1% and 3% (p = 0.76), readmissions 90 days 2.7% and 6.6% (p = 0.183), transfusions 5.5% and 15.2% (p = 0.033). Conclusion: The implementation of a multiprofessional CPPA contributed to the implementation of care protocols, favoring greater patient safety. Level of Evidence III; Retrospective Comparative Study.
- 1 January 2024
- Published by FapUNIFESP (SciELO) in Acta Ortopedica Brasileira
- Vol. 32 (1) , e269506
Open AccessBENEFITS OF A CLINICAL PATHWAY IN TOTAL KNEE ARTHROPLASTY
Objective: Demonstrate whether a multiprofessional Clinical Pathway Program in Total Knee Arthroplasty (CPPA) contributesto optimizing hospital care. Method: Retrospective study of medical data of care indicators in 310 patients divided into two groups: A- who underwent arthroplasty in the last biennium before the introduction of the CPPA (n=144) and group B- who underwent TKA in the biennium after the introduction of the CPPA (n=166). Results: Postoperative showed a significant difference in favor of group B over group A for hospitalization time in days 4.33 ± 2.79 and 5.4 ± 1.67 (p<0.001), time of prophylactic antibiotic in hours 28.13 ± 33.77 and 81.49 ± 40.91 (p<0.001), referral to the intensive care unit 40.9% and 73.4% (p<0.001), initiation of thromboprophylaxis within 24 hours 97.9% and 82.5% (p<0.001), use of elastic stockings and/or intermittent compression prescribed for thromboprophylaxis 89.5% and 31.2% (p<0.001), initiation of rehabilitation within 24 hours 90.1% and 66.1% (p<0.001), readmissions within 30 days 4.1% and 3% (p = 0.76), readmissions 90 days 2.7% and 6.6% (p = 0.183), transfusions 5.5% and 15.2% (p = 0.033). Conclusion: The implementation of a multiprofessional CPPA contributed to the implementation of care protocols, favoring greater patient safety. Level of Evidence III; Retrospective Comparative Study.
- Open Access
- 21 June 2021
- Published by Georg Thieme Verlag KG in Revista Brasileira de Ortopedia
- Vol. 56 (06) , 747-760
Tradução e adaptação transcultural para a língua portuguesa do Questionário Banff para Instabilidade Patelar
Objetivo Realizar a tradução para a língua portuguesa falada no Brasil e a adaptação transcultural do questionário Banff para Instabilidade Patelar. Métodos A tradução e adaptação transcultural seguiu o processo de validação linguístico proposto por diretrizes internacionais, que consiste em seis etapas: tradução, síntese, retrotradução, revisão pelo comitê de especialistas, pré-teste, e apresentação do relatório final aos autores do questionário original. Foram incluídos no estudo pacientes alfabetizados, com diagnóstico de instabilidade patelar recorrente, com mais de 12 anos de idade, que assinaram ou tiveram o termo de consentimento livre e esclarecido assinado por um responsável legal. Foram excluídos do estudo pacientes portadores de comorbidades neurológicas ou sistêmicas. Resultados Um total de 62 pacientes (18 homens e 44 mulheres) foram incluídos no estudo. Durante os processos de tradução e harmonização das retrotraduções, foram observadas discrepâncias, que foram modificadas sem necessidade de reformulação. Não foram necessárias substituições na versão do pré-teste. Conclusão O Questionário Banff para Instabilidade Patelar foi traduzido e adaptado transculturalmente para a língua portuguesa falada no Brasil com sucesso, podendo ser utilizado para a avaliação de pacientes portadores de instabilidade patelar falantes desta língua. * Trabalho realizado pelo Departamento de Ortopedia e Traumatologia, Escola Paulista de Medicina, Universidade Federal de São Paulo, São Paulo, SP, Brasil. Received: 23 April 2020 Accepted: 16 September 2020 Article published online: 21 June 2021 © 2021. Sociedade Brasileira de Ortopedia e Traumatologia. This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commecial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/) Thieme Revinter Publicações Ltda. Rua do Matoso 170, Rio de Janeiro, RJ, CEP 20270-135, Brazil
- 21 June 2021
- Published by Georg Thieme Verlag KG in Revista Brasileira de Ortopedia
- Vol. 56 (06) , 747-760
Open AccessTradução e adaptação transcultural para a língua portuguesa do Questionário Banff para Instabilidade Patelar
Objetivo Realizar a tradução para a língua portuguesa falada no Brasil e a adaptação transcultural do questionário Banff para Instabilidade Patelar. Métodos A tradução e adaptação transcultural seguiu o processo de validação linguístico proposto por diretrizes internacionais, que consiste em seis etapas: tradução, síntese, retrotradução, revisão pelo comitê de especialistas, pré-teste, e apresentação do relatório final aos autores do questionário original. Foram incluídos no estudo pacientes alfabetizados, com diagnóstico de instabilidade patelar recorrente, com mais de 12 anos de idade, que assinaram ou tiveram o termo de consentimento livre e esclarecido assinado por um responsável legal. Foram excluídos do estudo pacientes portadores de comorbidades neurológicas ou sistêmicas. Resultados Um total de 62 pacientes (18 homens e 44 mulheres) foram incluídos no estudo. Durante os processos de tradução e harmonização das retrotraduções, foram observadas discrepâncias, que foram modificadas sem necessidade de reformulação. Não foram necessárias substituições na versão do pré-teste. Conclusão O Questionário Banff para Instabilidade Patelar foi traduzido e adaptado transculturalmente para a língua portuguesa falada no Brasil com sucesso, podendo ser utilizado para a avaliação de pacientes portadores de instabilidade patelar falantes desta língua. * Trabalho realizado pelo Departamento de Ortopedia e Traumatologia, Escola Paulista de Medicina, Universidade Federal de São Paulo, São Paulo, SP, Brasil. Received: 23 April 2020 Accepted: 16 September 2020 Article published online: 21 June 2021 © 2021. Sociedade Brasileira de Ortopedia e Traumatologia. This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commecial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/) Thieme Revinter Publicações Ltda. Rua do Matoso 170, Rio de Janeiro, RJ, CEP 20270-135, Brazil