Dmitriy V. Melnikov
Research Subjects
Dmitriy V. Melnikov has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
- Natalia Evgenievna Manturova
N.I. Pirogov Russian National Research Medical University
6 shared publications - U.A. Gotovtseva
Institute of Plastic Surgery and Cosmetology
3 shared publications - A.E. Shpitser
Institute of Plastic Surgery and Cosmetology
2 shared publications - A.E. Tserr
Institute of Plastic Surgery and Cosmetology
2 shared publications - Artyom V. Belyakov
Institute of Plastic Surgery and Cosmetology
2 shared publications - D.I. Kiseleva
Pirogov Russian National Research Medical University
2 shared publications
Latest Publications
- 21 May 2026
- Published by Media Sphere Publishing Group in Plastic Surgery and Aesthetic Medicine
- No. 2
Study of cutaneous sensitivity of the nipple-areolar complex using Semmes—Weinstein monofilaments in patients after breast reduction surgery
Objective. To evaluate and compare the frequency of tactile sensitivity disruptions in NAC among patients after reduction mammoplasty based on the type of pedicle used. Material and methods. The study included 100 patients (average age 46.4 years, average BMI 26.4 kg/m²) who underwent reduction mammoplasty from 2023 to 2026. A lateral pedicle was used in 40% of the cases, a medial pedicle in 30%, and upper and lower pedicles in 15% each. Tactile sensitivity was assessed postoperatively at six months using Semmes—Weinstein monofilaments. The evaluation was conducted at five control points on the NAC. A loss of sensitivity was defined as the absence of pressure sensation during three consecutive tests at least at one point. Results. The lowest frequency of sensitivity loss was found in the group with the lateral vascular pedicle at 7.5%. In the medial pedicle group the rate was 76.7%, the upper and lower groups showing 46.7% and 33.3%, respectively. Statistical analysis confirmed a significantly lower risk of sensitivity loss with the lateral pedicle compared to the medial (p<0.001), upper (p<0.05), and lower (p<0.05) pedicles. Discussion. These findings align with anatomical studies, which indicate that the primary source of innervation of the NAC (in 93% of cases) is the lateral cutaneous branch of the fourth intercostal nerve. The use of a lateral pedicle minimizes damage to these nerves. Additionally, existing literature highlights variability in the recovery times of sensitivity and the dependency of outcomes on the selected surgical technique. Conclusion. Lateral dermoglandular pedicle demonstrates significantly better results in maintaining tactile sensitivity of the NAC during the postoperative period compared other pedicles. The choice of the type of vascular pedicle should be made individually, taking into account the anatomical characteristics.
- 21 May 2026
- Published by Media Sphere Publishing Group in Plastic Surgery and Aesthetic Medicine
- No. 2
Study of cutaneous sensitivity of the nipple-areolar complex using Semmes—Weinstein monofilaments in patients after breast reduction surgery
Objective. To evaluate and compare the frequency of tactile sensitivity disruptions in NAC among patients after reduction mammoplasty based on the type of pedicle used. Material and methods. The study included 100 patients (average age 46.4 years, average BMI 26.4 kg/m²) who underwent reduction mammoplasty from 2023 to 2026. A lateral pedicle was used in 40% of the cases, a medial pedicle in 30%, and upper and lower pedicles in 15% each. Tactile sensitivity was assessed postoperatively at six months using Semmes—Weinstein monofilaments. The evaluation was conducted at five control points on the NAC. A loss of sensitivity was defined as the absence of pressure sensation during three consecutive tests at least at one point. Results. The lowest frequency of sensitivity loss was found in the group with the lateral vascular pedicle at 7.5%. In the medial pedicle group the rate was 76.7%, the upper and lower groups showing 46.7% and 33.3%, respectively. Statistical analysis confirmed a significantly lower risk of sensitivity loss with the lateral pedicle compared to the medial (p<0.001), upper (p<0.05), and lower (p<0.05) pedicles. Discussion. These findings align with anatomical studies, which indicate that the primary source of innervation of the NAC (in 93% of cases) is the lateral cutaneous branch of the fourth intercostal nerve. The use of a lateral pedicle minimizes damage to these nerves. Additionally, existing literature highlights variability in the recovery times of sensitivity and the dependency of outcomes on the selected surgical technique. Conclusion. Lateral dermoglandular pedicle demonstrates significantly better results in maintaining tactile sensitivity of the NAC during the postoperative period compared other pedicles. The choice of the type of vascular pedicle should be made individually, taking into account the anatomical characteristics.
- 21 May 2026
- Published by Media Sphere Publishing Group in Plastic Surgery and Aesthetic Medicine
- No. 2
Postoperative complications in patients with breast hypertrophy following reduction mammoplasty depending on vascular pedicle
Objective. To compare the incidence of postoperative complications associated with reduction mammoplasty depending on pedicle (lateral, medial, upper, and lower). Material and methods. A prospective study involved 100 patients with breast hypertrophy (mean age 46.4 years, mean BMI 26.4 kg/m²) who underwent reduction mammoplasty between 2023 and 2026. Lateral pedicle was used in 40% of patients, medial pedicle in 30%, upper and lower pedicles in 15% each. The follow-up period was 12 months and included clinical examinations, palpation and breast ultrasound. Complications included hematomas, necrosis of NAC, delayed wound healing, loss of NAC sensitivity, liponecrosis / cysts and infectious complications. Results. The most common complication across all groups was loss of NAC sensitivity. Lateral pedicle significantly reduced the risks of various complications compared to other pedicles. There was lower risk of lost NAC sensitivity compared to all other pedicle types (p<0.05), lower risk of partial NAC necrosis and delayed wound healing compared to medial pedicle (p<0.05), lower risk of liponecrosis/cysts compared to medial and upper pedicles (p<0.05), and lower risk of infectious complications compared to upper and lower pedicles (p0.05). These findings align with global data on high incidence of complications associated with lower pedicle. However, there are few researches comparing lateral pedicle with others. Our results demonstrate the advantages of lateral pedicle in preserving sensitivity and preventing ischemic and infectious complications. Conclusion. Lateral pedicle in reduction mammoplasty is associated with significantly lower rate of postoperative complications compared to medial, upper and lower pedicles. Nevertheless, choice of technique should be individual.
- 21 May 2026
- Published by Media Sphere Publishing Group in Plastic Surgery and Aesthetic Medicine
- No. 2
Postoperative complications in patients with breast hypertrophy following reduction mammoplasty depending on vascular pedicle
Objective. To compare the incidence of postoperative complications associated with reduction mammoplasty depending on pedicle (lateral, medial, upper, and lower). Material and methods. A prospective study involved 100 patients with breast hypertrophy (mean age 46.4 years, mean BMI 26.4 kg/m²) who underwent reduction mammoplasty between 2023 and 2026. Lateral pedicle was used in 40% of patients, medial pedicle in 30%, upper and lower pedicles in 15% each. The follow-up period was 12 months and included clinical examinations, palpation and breast ultrasound. Complications included hematomas, necrosis of NAC, delayed wound healing, loss of NAC sensitivity, liponecrosis / cysts and infectious complications. Results. The most common complication across all groups was loss of NAC sensitivity. Lateral pedicle significantly reduced the risks of various complications compared to other pedicles. There was lower risk of lost NAC sensitivity compared to all other pedicle types (p<0.05), lower risk of partial NAC necrosis and delayed wound healing compared to medial pedicle (p<0.05), lower risk of liponecrosis/cysts compared to medial and upper pedicles (p<0.05), and lower risk of infectious complications compared to upper and lower pedicles (p0.05). These findings align with global data on high incidence of complications associated with lower pedicle. However, there are few researches comparing lateral pedicle with others. Our results demonstrate the advantages of lateral pedicle in preserving sensitivity and preventing ischemic and infectious complications. Conclusion. Lateral pedicle in reduction mammoplasty is associated with significantly lower rate of postoperative complications compared to medial, upper and lower pedicles. Nevertheless, choice of technique should be individual.
- 21 May 2026
- Published by Media Sphere Publishing Group in Plastic Surgery and Aesthetic Medicine
- No. 2
Fascioglandular flap in T-inverted augmentation mastopexy: a prospective comparison of implant-associated complications and lower pole stability
Objective. To evaluate the effect of split-thickness fascioglandular flap (SFGF) on lower pole stability and complication rate after T-inverted augmentation mastopexy. Material and methods. A prospective study included 96 patients who underwent T-inverted augmentation mastopexy between May 2023 and March 2025. Patients were divided into two groups: the SFGF group (n=47) and the control group (n=49) with classical technique without autologous tissue support. Both groups were comparable in age, body mass index, and implant volume. The follow-up period was 12 months. The incidence of implant-associated complications (ptosis recurrence, bottoming-out, protrusion, implant migration, inframammary fold asymmetry) and dynamics of nipple-to-inframammary fold distance (N-IMF) were assessed. Results. In early postoperative period, no differences in N-IMF were found between groups (p>0.05). After the 3rd month, there were significant between-group differences (p<0.001) that persisted until 12 months. N-IMF increment over the follow-up period was +0.8 and +2.5 cm in both groups, respectively. The overall complication rate was lower in the SFGF group — 4 (8.5%) vs 19 (38.8%) in the control group (p<0.001). Lower pole stability was achieved in 91.5% and 63.3% of patients, respectively (p=0.001). Conclusion. Split-thickness fascioglandular flap is associated with greater lower pole stability and lower complication rate. These results require confirmation in larger studies with long-term follow-up.
- 21 May 2026
- Published by Media Sphere Publishing Group in Plastic Surgery and Aesthetic Medicine
- No. 2
Fascioglandular flap in T-inverted augmentation mastopexy: a prospective comparison of implant-associated complications and lower pole stability
Objective. To evaluate the effect of split-thickness fascioglandular flap (SFGF) on lower pole stability and complication rate after T-inverted augmentation mastopexy. Material and methods. A prospective study included 96 patients who underwent T-inverted augmentation mastopexy between May 2023 and March 2025. Patients were divided into two groups: the SFGF group (n=47) and the control group (n=49) with classical technique without autologous tissue support. Both groups were comparable in age, body mass index, and implant volume. The follow-up period was 12 months. The incidence of implant-associated complications (ptosis recurrence, bottoming-out, protrusion, implant migration, inframammary fold asymmetry) and dynamics of nipple-to-inframammary fold distance (N-IMF) were assessed. Results. In early postoperative period, no differences in N-IMF were found between groups (p>0.05). After the 3rd month, there were significant between-group differences (p<0.001) that persisted until 12 months. N-IMF increment over the follow-up period was +0.8 and +2.5 cm in both groups, respectively. The overall complication rate was lower in the SFGF group — 4 (8.5%) vs 19 (38.8%) in the control group (p<0.001). Lower pole stability was achieved in 91.5% and 63.3% of patients, respectively (p=0.001). Conclusion. Split-thickness fascioglandular flap is associated with greater lower pole stability and lower complication rate. These results require confirmation in larger studies with long-term follow-up.
- 21 May 2026
- Published by Media Sphere Publishing Group in Plastic Surgery and Aesthetic Medicine
- No. 2
Comparison of Breast-Q scores following T-inverted augmentation mastopexy using split-thickness fascioglandular flap and standard technique: a prospective study
Objective. To compare satisfaction with breasts, sexual and physical well-being using the BREAST-Q questionnaire in 12 months after T-inverted augmentation mastopexy with and without split-thickness fascioglandular flap. Material and methods. A single-center prospective study included 85 patients who underwent T-inverted augmentation mastopexy with (n=40) and without (n=45) split-thickness fascioglandular flap. Before surgery and 12 months after procedure, patients were assessed using the BREAST-Q questionnaire on three scales: satisfaction with breast, sexual and physical well-being. Data are presented as median and interquartile range. The Mann—Whitney test was used for between-group comparisons and the Wilcoxon test for within-group comparisons. The effect size was estimated using r coefficient. Results. No significant between-group differences were observed preoperatively across all scales. At 12 months, both groups demonstrated improvement in BREAST-Q scores compared to baseline. However, postoperative values for all three scales were higher in split-thickness fascioglandular flap group: satisfaction with breasts — 85.0 [77.0; 91.0] versus 74.0 [68.0; 80.0] points (p<0.001), sexual well-being — 79.0 [73.0; 90.0] versus 71.0 [64.0; 77.0] points (p<0.001), physical well-being — 73.5 [64.5; 85.3] versus 67.0 [60.0; 73.0] points (p=0.003). Effect sizes for satisfaction with breasts and sexual well-being scales were large in both groups, while effect size for physical well-being was moderate. Conclusion. T-inverted augmentation mastopexy was associated with better BREAST-Q scores in both groups. However, split-thickness fascioglandular flap was associated with higher postoperative scores across all scales at 12 months following surgery.
- 21 May 2026
- Published by Media Sphere Publishing Group in Plastic Surgery and Aesthetic Medicine
- No. 2
Comparison of Breast-Q scores following T-inverted augmentation mastopexy using split-thickness fascioglandular flap and standard technique: a prospective study
Objective. To compare satisfaction with breasts, sexual and physical well-being using the BREAST-Q questionnaire in 12 months after T-inverted augmentation mastopexy with and without split-thickness fascioglandular flap. Material and methods. A single-center prospective study included 85 patients who underwent T-inverted augmentation mastopexy with (n=40) and without (n=45) split-thickness fascioglandular flap. Before surgery and 12 months after procedure, patients were assessed using the BREAST-Q questionnaire on three scales: satisfaction with breast, sexual and physical well-being. Data are presented as median and interquartile range. The Mann—Whitney test was used for between-group comparisons and the Wilcoxon test for within-group comparisons. The effect size was estimated using r coefficient. Results. No significant between-group differences were observed preoperatively across all scales. At 12 months, both groups demonstrated improvement in BREAST-Q scores compared to baseline. However, postoperative values for all three scales were higher in split-thickness fascioglandular flap group: satisfaction with breasts — 85.0 [77.0; 91.0] versus 74.0 [68.0; 80.0] points (p<0.001), sexual well-being — 79.0 [73.0; 90.0] versus 71.0 [64.0; 77.0] points (p<0.001), physical well-being — 73.5 [64.5; 85.3] versus 67.0 [60.0; 73.0] points (p=0.003). Effect sizes for satisfaction with breasts and sexual well-being scales were large in both groups, while effect size for physical well-being was moderate. Conclusion. T-inverted augmentation mastopexy was associated with better BREAST-Q scores in both groups. However, split-thickness fascioglandular flap was associated with higher postoperative scores across all scales at 12 months following surgery.
- 21 May 2026
- Published by Media Sphere Publishing Group in Plastic Surgery and Aesthetic Medicine
- No. 2
Outcomes of surgical correction for congenital breast asymmetry
Objective. To compare the effectiveness of symmetrical mastopexy with different-sized Mentor and Motiva implants versus asymmetric surgical techniques in correction of congenital breast asymmetry. Material and methods. A prospective cohort study included 28 patients with congenital breast asymmetry who underwent surgery in 2021—2025. The main group (n=20) underwent symmetrical mastopexy (identical procedure on both breasts) with different-sized implants. The control group (n=8) underwent asymmetric procedures (different types of mastopexy and/or incisions) also with different-sized implants. Morphometric parameters (sternal notch-to-nipple distance, nipple-to-inframammary fold distance, midline-to-nipple distance, areola diameter, breast footprint width), patient satisfaction (BREAST-Q), complication and redo surgery rates were assessed. Nonparametric methods (Mann—Whitney U test, Wilcoxon signed-rank test) were used. Data were presented as median and interquartile range Me [Q1; Q3]. Results. In the main group, postoperative absolute differences between sides were 0—0.1 cm for all parameters. The control group retained residual differences in nipple-to-inframammary fold distance (0.3 [0.1; 0.7] cm) and midline-to-nipple distance (0.2 [0.1; 0.4] cm) (p<0.05). The median BREAST-Q score at 6 months was 99.0 [98.0; 100] and 89.0 [85.0; 93.0], respectively (p<0.01). Redo surgeries were performed in 5 (25.0%) and 3 (37.5%) patients, respectively. Areola corrections dominated in the main group (4 out of 5). In the control group, implant exchange and areola corrections were carried out in 1 and 2 cases, respectively. No capsular contracture or infectious complications occurred. Conclusion. Symmetrical mastopexy with different-sized implants provides more accurate restoration of symmetry compared to asymmetric procedures with comparable satisfaction and acceptable redo surgery rate.
- 21 May 2026
- Published by Media Sphere Publishing Group in Plastic Surgery and Aesthetic Medicine
- No. 2
Outcomes of surgical correction for congenital breast asymmetry
Objective. To compare the effectiveness of symmetrical mastopexy with different-sized Mentor and Motiva implants versus asymmetric surgical techniques in correction of congenital breast asymmetry. Material and methods. A prospective cohort study included 28 patients with congenital breast asymmetry who underwent surgery in 2021—2025. The main group (n=20) underwent symmetrical mastopexy (identical procedure on both breasts) with different-sized implants. The control group (n=8) underwent asymmetric procedures (different types of mastopexy and/or incisions) also with different-sized implants. Morphometric parameters (sternal notch-to-nipple distance, nipple-to-inframammary fold distance, midline-to-nipple distance, areola diameter, breast footprint width), patient satisfaction (BREAST-Q), complication and redo surgery rates were assessed. Nonparametric methods (Mann—Whitney U test, Wilcoxon signed-rank test) were used. Data were presented as median and interquartile range Me [Q1; Q3]. Results. In the main group, postoperative absolute differences between sides were 0—0.1 cm for all parameters. The control group retained residual differences in nipple-to-inframammary fold distance (0.3 [0.1; 0.7] cm) and midline-to-nipple distance (0.2 [0.1; 0.4] cm) (p<0.05). The median BREAST-Q score at 6 months was 99.0 [98.0; 100] and 89.0 [85.0; 93.0], respectively (p<0.01). Redo surgeries were performed in 5 (25.0%) and 3 (37.5%) patients, respectively. Areola corrections dominated in the main group (4 out of 5). In the control group, implant exchange and areola corrections were carried out in 1 and 2 cases, respectively. No capsular contracture or infectious complications occurred. Conclusion. Symmetrical mastopexy with different-sized implants provides more accurate restoration of symmetry compared to asymmetric procedures with comparable satisfaction and acceptable redo surgery rate.
- 22 February 2024
- Published by Media Sphere Publishing Group in Plastic Surgery and Aesthetic Medicine
- No. 1
Breast implant removal: indications and technical considerations
Objective. To analyze the technical approaches to breast implant removal with optimal aesthetic results. Material and methods. We assessed the indications for this surgery and surgical techniques depending on duration of implantation, admissibility of mastopexy and preferences of surgeons. Results. There were a few complications and high patient satisfaction with postoperative aesthetic results. Conclusion. We developed the optimal approaches for aesthetic problems in patients undergoing breast implant removal.
- 22 February 2024
- Published by Media Sphere Publishing Group in Plastic Surgery and Aesthetic Medicine
- No. 1
Breast implant removal: indications and technical considerations
Objective. To analyze the technical approaches to breast implant removal with optimal aesthetic results. Material and methods. We assessed the indications for this surgery and surgical techniques depending on duration of implantation, admissibility of mastopexy and preferences of surgeons. Results. There were a few complications and high patient satisfaction with postoperative aesthetic results. Conclusion. We developed the optimal approaches for aesthetic problems in patients undergoing breast implant removal.
- 7 December 2023
- Published by Media Sphere Publishing Group in Plastic Surgery and Aesthetic Medicine
- No. 4
Correction of combined breast asymmetry using symmetrical mastopexy and implants of different dimensions and designs
Breast asymmetry is defined as a discrepancy between the shape, volume, position of mammary glands or nipple-areolar complex, as well as combination of these abnormalities. According to the literature, approximately 88% of women have certain breast asymmetry. For many women, asymmetry per se can be an obvious aesthetic problem impairing quality of life. Optimal methods and algorithms for surgical correction of breast asymmetry have been developed for many years. To date, different approaches are used depending on the type of asymmetry. However, there is still no consensus on optimal approach and their combination for a particular issue. We present a patient with congenital breast asymmetry who underwent symmetrical mastopexy with implants of different sizes and designs. Preoperative and postoperative morphometry was performed to assess preoperative asymmetry and achievement of symmetry after surgery. Breast asymmetry is a serious problem for plastic surgeons. Our strategy implies symmetrical procedure for each gland while correction of different volumes is performed by implants of different sizes and designs.
- 7 December 2023
- Published by Media Sphere Publishing Group in Plastic Surgery and Aesthetic Medicine
- No. 4
Correction of combined breast asymmetry using symmetrical mastopexy and implants of different dimensions and designs
Breast asymmetry is defined as a discrepancy between the shape, volume, position of mammary glands or nipple-areolar complex, as well as combination of these abnormalities. According to the literature, approximately 88% of women have certain breast asymmetry. For many women, asymmetry per se can be an obvious aesthetic problem impairing quality of life. Optimal methods and algorithms for surgical correction of breast asymmetry have been developed for many years. To date, different approaches are used depending on the type of asymmetry. However, there is still no consensus on optimal approach and their combination for a particular issue. We present a patient with congenital breast asymmetry who underwent symmetrical mastopexy with implants of different sizes and designs. Preoperative and postoperative morphometry was performed to assess preoperative asymmetry and achievement of symmetry after surgery. Breast asymmetry is a serious problem for plastic surgeons. Our strategy implies symmetrical procedure for each gland while correction of different volumes is performed by implants of different sizes and designs.
- Open Access
- 20 May 2021
- Published by Research Institute of Microsurgery in Issues of Reconstructive and Plastic Surgery
- Vol. 24 (1) , 61-72
Microsurgery training: for whom and how?
Проанализировав достоинства и недостатки существующих курсов обучения микрохирургии, сотрудники кафедры пластической хирургии Сеченовского Университета в 2011 г. организовали трехэтапные микрохирургические курсы по принципу от простого к сложному, интегрировав в практическую подготовку теоретический материал, необходимый для формирования микрохирургического кругозора. Разделение процесса обучения на краткосрочные этапы, по мнению авторов, позволяет обучающимся постепенно погружаться в микрохирургический мир, при этом самим регулировать периодичность, частоту обучения и необходимость дальнейшего совершенствования навыков. Этапность делает обучение более доступным и позволяет популяризировать микрохирургию как универсальный метод для решения хирургических задач.
- 20 May 2021
- Published by Research Institute of Microsurgery in Issues of Reconstructive and Plastic Surgery
- Vol. 24 (1) , 61-72
Open AccessMicrosurgery training: for whom and how?
Проанализировав достоинства и недостатки существующих курсов обучения микрохирургии, сотрудники кафедры пластической хирургии Сеченовского Университета в 2011 г. организовали трехэтапные микрохирургические курсы по принципу от простого к сложному, интегрировав в практическую подготовку теоретический материал, необходимый для формирования микрохирургического кругозора. Разделение процесса обучения на краткосрочные этапы, по мнению авторов, позволяет обучающимся постепенно погружаться в микрохирургический мир, при этом самим регулировать периодичность, частоту обучения и необходимость дальнейшего совершенствования навыков. Этапность делает обучение более доступным и позволяет популяризировать микрохирургию как универсальный метод для решения хирургических задач.
- 6 June 2020
- Published by Oxford University Press (OUP) in Aesthetic Surgery Journal
- Vol. 41 (6) , 697-704
Three-Dimensional Description of the Angular Artery in the Nasolabial Fold
Due to its arterial vasculature, the nasolabial sulcus is one of the most challenging facial regions to treat when trying to ameliorate the signs of facial aging. The objective of the present study is to provide data on the three-dimensional course of the angular artery within the nasolabial sulcus in relationship to age, gender, and body mass index (BMI) to increase safety during minimally-invasive treatments. Thee hundred nasolabial sulci obtained from 75 males and 75 females with Russian Caucasian ethnic background (mean age, 45.7 ± 18.7 years; mean BMI, 25.14 ± 4.9 kg/m2) were analysed. Bilateral multi-planar measurements were based on contrast-enhanced cranial CT-scans. Up to three arteries could be identified within the nasolabial sulcus: ~ 90% contained one arterial trunk, ~9% had two trunks and ~1% had three trunks; females had more arteries than men. The artery is located at mean depth of 21.6mm at the oral commissure and of 8.9mm at the nasal ala. In 100% of the cases, the angular artery was lateral to the nasolabial sulcus; the smallest distance was at the oral commissure (11.91 ± 7.9mm) and the greatest was at the nasal ala 13.73 ± 3.9. In contrast to current concepts, the angular artery is not located strictly subdermal to the nasolabial sulcus but at a variable depth, and in 100% of the investigated cases lateral to the nasolabial sulcus. With increasing age, the depth and lateral distance between arteries and sulci reduces significantly, underscoring the need for special caution when injecting this site in older patients.
- 6 June 2020
- Published by Oxford University Press (OUP) in Aesthetic Surgery Journal
- Vol. 41 (6) , 697-704
Three-Dimensional Description of the Angular Artery in the Nasolabial Fold
Due to its arterial vasculature, the nasolabial sulcus is one of the most challenging facial regions to treat when trying to ameliorate the signs of facial aging. The objective of the present study is to provide data on the three-dimensional course of the angular artery within the nasolabial sulcus in relationship to age, gender, and body mass index (BMI) to increase safety during minimally-invasive treatments. Thee hundred nasolabial sulci obtained from 75 males and 75 females with Russian Caucasian ethnic background (mean age, 45.7 ± 18.7 years; mean BMI, 25.14 ± 4.9 kg/m2) were analysed. Bilateral multi-planar measurements were based on contrast-enhanced cranial CT-scans. Up to three arteries could be identified within the nasolabial sulcus: ~ 90% contained one arterial trunk, ~9% had two trunks and ~1% had three trunks; females had more arteries than men. The artery is located at mean depth of 21.6mm at the oral commissure and of 8.9mm at the nasal ala. In 100% of the cases, the angular artery was lateral to the nasolabial sulcus; the smallest distance was at the oral commissure (11.91 ± 7.9mm) and the greatest was at the nasal ala 13.73 ± 3.9. In contrast to current concepts, the angular artery is not located strictly subdermal to the nasolabial sulcus but at a variable depth, and in 100% of the investigated cases lateral to the nasolabial sulcus. With increasing age, the depth and lateral distance between arteries and sulci reduces significantly, underscoring the need for special caution when injecting this site in older patients.
- Open Access
- 1 May 2019
- Published by Wolters Kluwer Health in Plastic and Reconstructive Surgery - Global Open
- Vol. 7 (5) , e2190
Deep Inferior Epigastric Artery Perforator Flap Breast Reconstruction in a Patient with a History of Toxic Epidermal Necrosis
Summary: Breast reconstruction is a procedure that is in increased demand due to high incidence of breast cancer. To provide high-quality esthetic and functional results, each patient should be properly managed. Patients with comorbid conditions have become more common and account for higher difficulty in perioperative patient management. Despite the ongoing diversification of comorbidities in patients undergoing breast reconstruction, it is the patient’s right to receive this final stage in rehabilitation after a mastectomy. We present a clinical vignette of a patient with a severe comorbid hypersensitivity disorder undergoing breast reconstruction with the deep inferior epigastric artery perforator flap. Despite early postoperative complications, our brigade managed to maintain flap viability without the use of surgical or pharmacological assistance in a patient with a history of toxic epidermal necrosis syndrome.
- 1 May 2019
- Published by Wolters Kluwer Health in Plastic and Reconstructive Surgery - Global Open
- Vol. 7 (5) , e2190
Open AccessDeep Inferior Epigastric Artery Perforator Flap Breast Reconstruction in a Patient with a History of Toxic Epidermal Necrosis
Summary: Breast reconstruction is a procedure that is in increased demand due to high incidence of breast cancer. To provide high-quality esthetic and functional results, each patient should be properly managed. Patients with comorbid conditions have become more common and account for higher difficulty in perioperative patient management. Despite the ongoing diversification of comorbidities in patients undergoing breast reconstruction, it is the patient’s right to receive this final stage in rehabilitation after a mastectomy. We present a clinical vignette of a patient with a severe comorbid hypersensitivity disorder undergoing breast reconstruction with the deep inferior epigastric artery perforator flap. Despite early postoperative complications, our brigade managed to maintain flap viability without the use of surgical or pharmacological assistance in a patient with a history of toxic epidermal necrosis syndrome.