Elumalai Natarajan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Elumalai Natarajan has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
M. M. Vijayalakshmi
Department of Building & Environment, Sathyabama Institute of Science & Technology 2 , Jeppiar Nagar, Rajiv Gandhi Salai, Chennai, Tamil Nadu 600119
4 shared publicationsDeepak Kumar Murugan
2 shared publicationsDillibabu Venugopal
Department of Mechanical Engineering RMK College of Engineering and Technology Anna University Chennai India
2 shared publications- Kalilur Rahiman Arshad Ahmed
Department of Mechanical Engineering, Institute for Energy Studies, Anna University, Chennai, India
2 shared publications - Kulasekharan Narasingamurthi
Dhanalakshmi Srinivasan Engineering College
2 shared publications Lakshmanan Thangavelu
Department of Mechanical Engineering S. A Engineering College Anna University Chennai India
2 shared publications
Latest Publications
- 1 November 2019
- Published by Elsevier in Applied Thermal Engineering
- Vol. 162
Thermal performance enhancement in a parabolic trough receiver tube with internal toroidal rings: A numerical investigation
- 1 November 2019
- Published by Elsevier in Applied Thermal Engineering
- Vol. 162
Thermal performance enhancement in a parabolic trough receiver tube with internal toroidal rings: A numerical investigation
- 1 January 2019
- Published by Centre for Evaluation in Education and Science (CEON/CEES) in FME Transactions
- Vol. 47 (3) , 591-598
A detailed mathematical modelling and experimental validation of top water cooled solar PV module
In this research article, an analytical model has been developed to examine the electrical and thermal behaviour of a solar photovoltaic module with top water cooling. Mathematical calculations have been performed under India, Chennai (latitude: 13.06° N and longitude: 80.11° E) prevailing weather conditions. Three modes of heat transfer mechanisms are considered in the thermal model and computed using improved correlations. The model validation against the experimental data exhibited a good agreement. Daily average electrical and overall thermal efficiency of a PV module with top water flow have been found to be 14.29% and 45.44% respectively. Water flows on top side of the PV module decreases the average module temperature of a day from 56.67°C to 39.44°C, and the average daily module electrical efficiency is increased up to 14.29%, compared to 12.74% efficiency of PV module without cooling.
- 1 January 2019
- Published by Centre for Evaluation in Education and Science (CEON/CEES) in FME Transactions
- Vol. 47 (3) , 591-598
A detailed mathematical modelling and experimental validation of top water cooled solar PV module
In this research article, an analytical model has been developed to examine the electrical and thermal behaviour of a solar photovoltaic module with top water cooling. Mathematical calculations have been performed under India, Chennai (latitude: 13.06° N and longitude: 80.11° E) prevailing weather conditions. Three modes of heat transfer mechanisms are considered in the thermal model and computed using improved correlations. The model validation against the experimental data exhibited a good agreement. Daily average electrical and overall thermal efficiency of a PV module with top water flow have been found to be 14.29% and 45.44% respectively. Water flows on top side of the PV module decreases the average module temperature of a day from 56.67°C to 39.44°C, and the average daily module electrical efficiency is increased up to 14.29%, compared to 12.74% efficiency of PV module without cooling.
- Open Access
- 1 January 2019
- Published by National Library of Serbia in Thermal Science
- Vol. 23 (2 Part B) , 1043-1053
Air and oxygen gasification simulation analysis of sawdust
Gasification is the conversion process of low-grade solid fuel into gaseous fuel by thermo-chemical reactions. In this paper air gasification and oxygen gasification simulation of sawdust is carried out using FACTSAGE 6.3 software. The effect of temperature and equivalence ratio (Φ) on producer gas composition is analysed. Combustible gas compositions (H2, CO and CH4) are found out at different operating conditions for air and oxygen gasification separately. Temperature range is 200-1200°C and Φ value varied from 0.3-0.6. Gas heating values (HHV & LHV) carbon conversion efficiency (CCE) and cold gas efficiency (CGE) are calculated. In air gasification, maximum HHV of 5.96 MJ/Nm3 is reached at 700°C for Φ=0.3 and in oxygen gasification, 9.85 MJ/Nm3 is attained at 800°C and Φ=0.3. The maximum cold gas efficiency of 84.37 and 84.73% reached by air and oxygen gasification respectively at 1200°C for Φ=0.3.
- 1 January 2019
- Published by National Library of Serbia in Thermal Science
- Vol. 23 (2 Part B) , 1043-1053
Open AccessAir and oxygen gasification simulation analysis of sawdust
Gasification is the conversion process of low-grade solid fuel into gaseous fuel by thermo-chemical reactions. In this paper air gasification and oxygen gasification simulation of sawdust is carried out using FACTSAGE 6.3 software. The effect of temperature and equivalence ratio (Φ) on producer gas composition is analysed. Combustible gas compositions (H2, CO and CH4) are found out at different operating conditions for air and oxygen gasification separately. Temperature range is 200-1200°C and Φ value varied from 0.3-0.6. Gas heating values (HHV & LHV) carbon conversion efficiency (CCE) and cold gas efficiency (CGE) are calculated. In air gasification, maximum HHV of 5.96 MJ/Nm3 is reached at 700°C for Φ=0.3 and in oxygen gasification, 9.85 MJ/Nm3 is attained at 800°C and Φ=0.3. The maximum cold gas efficiency of 84.37 and 84.73% reached by air and oxygen gasification respectively at 1200°C for Φ=0.3.
- 2 October 2018
- Published by ASTM International in Journal of Testing and Evaluation
- Vol. 48 (2) , 1031-1054
Energy Investigation in Serpentine Heat Exchanger Using Aluminum Oxide Nanofluid on Solar Photovoltaic/Thermal System
A solar photovoltaic thermal system (SPV/T) is a hybrid technology that produces electrical power and thermal energy simultaneously with better overall performance. The objective of this study is to evaluate the effects of utilizing a nanofluid as one of the coolants in the performance of an SPV/T system. The working fluids considered in this evaluation of the system are pure water and aluminum oxide (Al2O3) nanoparticles of φ = 0.1 % and 0.2 % concentration in (w/v)%, mixed in milli-Q water as the base fluid. The study focuses on the heat transfer characteristics of working fluids through a serpentine flow copper tube heat exchanger in comparison with water. This experimental setup consists of an SPV/T system with 100 W capacity and a collector area of 0.914622 m2. For the flow supplied by the pump to the SPV/T system for the nanofluids with φ = 0.1 % and 0.2 % and water at mass flow rates of 0.015, 0.0133, and 0.0117 kg/s, the electrical (PV) efficiency for water was between 10.82 % and 11.06 %—for Al2O3 0.1 %, 12.19 %–13.13 %, and for Al2O3 0.2 %, 12.47 %–13.41 %. The thermal efficiency for water was between 53.61 % and 54.07 %; for Al2O3 0.1 %, it was 69.45 %–69.67 %, and for Al2O3 0.2 %, it was 70.76 %–71.02 %, respectively.
- 2 October 2018
- Published by ASTM International in Journal of Testing and Evaluation
- Vol. 48 (2) , 1031-1054
Energy Investigation in Serpentine Heat Exchanger Using Aluminum Oxide Nanofluid on Solar Photovoltaic/Thermal System
A solar photovoltaic thermal system (SPV/T) is a hybrid technology that produces electrical power and thermal energy simultaneously with better overall performance. The objective of this study is to evaluate the effects of utilizing a nanofluid as one of the coolants in the performance of an SPV/T system. The working fluids considered in this evaluation of the system are pure water and aluminum oxide (Al2O3) nanoparticles of φ = 0.1 % and 0.2 % concentration in (w/v)%, mixed in milli-Q water as the base fluid. The study focuses on the heat transfer characteristics of working fluids through a serpentine flow copper tube heat exchanger in comparison with water. This experimental setup consists of an SPV/T system with 100 W capacity and a collector area of 0.914622 m2. For the flow supplied by the pump to the SPV/T system for the nanofluids with φ = 0.1 % and 0.2 % and water at mass flow rates of 0.015, 0.0133, and 0.0117 kg/s, the electrical (PV) efficiency for water was between 10.82 % and 11.06 %—for Al2O3 0.1 %, 12.19 %–13.13 %, and for Al2O3 0.2 %, 12.47 %–13.41 %. The thermal efficiency for water was between 53.61 % and 54.07 %; for Al2O3 0.1 %, it was 69.45 %–69.67 %, and for Al2O3 0.2 %, it was 70.76 %–71.02 %, respectively.
- Open Access
- 1 September 2018
- Published by Elsevier in Desalination and Water Treatment
- Vol. 125, 1-7
Experimental investigation on the time dependant behaviour of productivity of a stacked solar still
- 1 September 2018
- Published by Elsevier in Desalination and Water Treatment
- Vol. 125, 1-7
Open AccessExperimental investigation on the time dependant behaviour of productivity of a stacked solar still
- 25 May 2018
- Published by Walter de Gruyter GmbH in International Journal of Turbo & Jet-Engines
- Vol. 35 (2) , 193-201
Computational Investigations in Rectangular Convergent and Divergent Ribbed Channels
Computational investigations on the rib turbulated flow inside a convergent and divergent rectangular channel with square ribs of different rib heights and different Reynolds numbers (Re=20,000, 40,000 and 60,000). The ribs were arranged in a staggered fashion between the upper and lower surfaces of the test section. Computational investigations are carried out using computational fluid dynamic software ANSYS Fluent 14.0. Suitable solver settings like turbulence models were identified from the literature and the boundary conditions for the simulations on a solution of independent grid. Computations were carried out for both convergent and divergent channels with 0 (smooth duct), 1.5, 3, 6, 9 and 12 mm rib heights, to identify the ribbed channel with optimal performance, assessed using a thermo hydraulic performance parameter. The convergent and divergent rectangular channels show higher Nu values than the standard correlation values.
- 25 May 2018
- Published by Walter de Gruyter GmbH in International Journal of Turbo & Jet-Engines
- Vol. 35 (2) , 193-201
Computational Investigations in Rectangular Convergent and Divergent Ribbed Channels
Computational investigations on the rib turbulated flow inside a convergent and divergent rectangular channel with square ribs of different rib heights and different Reynolds numbers (Re=20,000, 40,000 and 60,000). The ribs were arranged in a staggered fashion between the upper and lower surfaces of the test section. Computational investigations are carried out using computational fluid dynamic software ANSYS Fluent 14.0. Suitable solver settings like turbulence models were identified from the literature and the boundary conditions for the simulations on a solution of independent grid. Computations were carried out for both convergent and divergent channels with 0 (smooth duct), 1.5, 3, 6, 9 and 12 mm rib heights, to identify the ribbed channel with optimal performance, assessed using a thermo hydraulic performance parameter. The convergent and divergent rectangular channels show higher Nu values than the standard correlation values.
- Open Access
- 1 January 2018
- Published by National Library of Serbia in Thermal Science
- Vol. 23 (00) , 68
Energy, exergy and sustainability analysis of rice husk air gasification process
Biomass is one of the renewable energy sources to produce power with zero carbon dioxide emission, biomass gasification process considered as a sustainable technology for energy conversion. This paper deals with rice husk air gasification simulation using non- stoichiometric equilibrium model based on Gibbs free energy minimisation. FACTSAGE 6.3 software used to calculate gas composition at temperature range 600-1000°C and equivalence ratio (Ф) range 0.15 - 0.55. Maximum gas mixture exergy of 9551.7 kJ per kg of rice husk is obtained at Ф=0.25 and 725°C. Chemical exergy contributes 89.90 - 94.85% of total gas mixture exergy, cold gas efficiency and exergetic efficiency varies in the range of 25.19 - 70.71% and 23.11 - 62.24% respectively in operating condition. Rice husk gasification process analysed by evaluating, sustainability index (SI) and environmental destruction factor (Ced).
- 1 January 2018
- Published by National Library of Serbia in Thermal Science
- Vol. 23 (00) , 68
Open AccessEnergy, exergy and sustainability analysis of rice husk air gasification process
Biomass is one of the renewable energy sources to produce power with zero carbon dioxide emission, biomass gasification process considered as a sustainable technology for energy conversion. This paper deals with rice husk air gasification simulation using non- stoichiometric equilibrium model based on Gibbs free energy minimisation. FACTSAGE 6.3 software used to calculate gas composition at temperature range 600-1000°C and equivalence ratio (Ф) range 0.15 - 0.55. Maximum gas mixture exergy of 9551.7 kJ per kg of rice husk is obtained at Ф=0.25 and 725°C. Chemical exergy contributes 89.90 - 94.85% of total gas mixture exergy, cold gas efficiency and exergetic efficiency varies in the range of 25.19 - 70.71% and 23.11 - 62.24% respectively in operating condition. Rice husk gasification process analysed by evaluating, sustainability index (SI) and environmental destruction factor (Ced).
- 27 November 2017
- Published by ASTM International in Journal of Testing and Evaluation
- Vol. 46 (2) , 783-797
Energy and Exergy Efficiency of Flat Plate PVT Collector With Forced Convection
This article presented the detailed energy and exergy analysis performed on 4 different configurations of solar photovoltaic thermal collectors under Chennai climatic conditions. A comparative performance study of all the four different configurations was performed considering two mass flow rates of air as 0.00847 and 0.01130 kg/s. The parameters such as PV temperature, inlet and outlet air flow temperatures in the cooling channels, solar radiation, and ambient temperature were analyzed and studied in detail. It was found that the collector performance enhanced with increase in air velocity with further increase in heat transfer coefficient between the absorber surface and air. The experimental results obtained from the present work and the experimental performances of previously published results are found to be in good agreement. The electrical efficiency was from 9.8 to 12.9 % for 0.00847 kg/s and from 10.3 to 13.9 % for mass flow rate of air 0.0113 kg/s. The maximum thermal efficiency lies between 4.3 and 12.4 % for the mass flow rate of air 0.00847 kg/s and from 6.5 to 15.9 % for mass flow rate of air 0.01130 kg/s, respectively. Similarly, the maximum exergy efficiency ranges from 11.2 to 38.6 % for mass flow rate of air 0.00847 kg/s, and it varies between 18.4 and 49.4 % for mass flow rate of air 0.01130 kg/s.
- 27 November 2017
- Published by ASTM International in Journal of Testing and Evaluation
- Vol. 46 (2) , 783-797
Energy and Exergy Efficiency of Flat Plate PVT Collector With Forced Convection
This article presented the detailed energy and exergy analysis performed on 4 different configurations of solar photovoltaic thermal collectors under Chennai climatic conditions. A comparative performance study of all the four different configurations was performed considering two mass flow rates of air as 0.00847 and 0.01130 kg/s. The parameters such as PV temperature, inlet and outlet air flow temperatures in the cooling channels, solar radiation, and ambient temperature were analyzed and studied in detail. It was found that the collector performance enhanced with increase in air velocity with further increase in heat transfer coefficient between the absorber surface and air. The experimental results obtained from the present work and the experimental performances of previously published results are found to be in good agreement. The electrical efficiency was from 9.8 to 12.9 % for 0.00847 kg/s and from 10.3 to 13.9 % for mass flow rate of air 0.0113 kg/s. The maximum thermal efficiency lies between 4.3 and 12.4 % for the mass flow rate of air 0.00847 kg/s and from 6.5 to 15.9 % for mass flow rate of air 0.01130 kg/s, respectively. Similarly, the maximum exergy efficiency ranges from 11.2 to 38.6 % for mass flow rate of air 0.00847 kg/s, and it varies between 18.4 and 49.4 % for mass flow rate of air 0.01130 kg/s.
- Open Access
- 1 January 2017
- Published by National Library of Serbia in Thermal Science
- Vol. 21 (6 Part B) , 2757-2768
Performance enhancement studies in a thermosyphon flat plate solar water heater with CuO nanofluid
Experiments were conducted on a thermosyphon type flat plate collector, inclined at 45?, for water heating application. Water and water based nanofluids were used as absorber fluid to gain heat from solar rays incident on the flat plate col-lector. Nanofluids were prepared by adding CuO nanoparticles of 40-50 nm size to the base fluid at 0.1, 0.2, 0.3, and 0.5 wt% (?). The hot absorber fluid was made to circulate in the shell side of a heat exchanger, placed at the top of the flat plate collector, where utility water was circulated inside a helically coiled Cu tube. Temperatures at strategic locations in the flat plate collector, working fluid, utility water inlet and outlet were measured. The nanofluid increases the collector efficiency with increasing ?. A highest efficiency enhancement of 5.7% was observed for the nanofluid with ? = 0.2 having a mass flow rate of 0.0033 kg/s. The 3-D, steady-state, conjugate heat transfer CFD analyses were carried out using the ANSYS FLUENT 15.0 software. Theoretically estimated buoyancy induced fluid flow rates were close with the CFD predictions and thus validates the computational methodology.
- 1 January 2017
- Published by National Library of Serbia in Thermal Science
- Vol. 21 (6 Part B) , 2757-2768
Open AccessPerformance enhancement studies in a thermosyphon flat plate solar water heater with CuO nanofluid
Experiments were conducted on a thermosyphon type flat plate collector, inclined at 45?, for water heating application. Water and water based nanofluids were used as absorber fluid to gain heat from solar rays incident on the flat plate col-lector. Nanofluids were prepared by adding CuO nanoparticles of 40-50 nm size to the base fluid at 0.1, 0.2, 0.3, and 0.5 wt% (?). The hot absorber fluid was made to circulate in the shell side of a heat exchanger, placed at the top of the flat plate collector, where utility water was circulated inside a helically coiled Cu tube. Temperatures at strategic locations in the flat plate collector, working fluid, utility water inlet and outlet were measured. The nanofluid increases the collector efficiency with increasing ?. A highest efficiency enhancement of 5.7% was observed for the nanofluid with ? = 0.2 having a mass flow rate of 0.0033 kg/s. The 3-D, steady-state, conjugate heat transfer CFD analyses were carried out using the ANSYS FLUENT 15.0 software. Theoretically estimated buoyancy induced fluid flow rates were close with the CFD predictions and thus validates the computational methodology.