Ki Hyun Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ki Hyun Lee has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Jeong Ho Kim
Department of Radiology, Gil Medical Center, Gachon University College of Medicine, Incheon, Republic of Korea
3 shared publications - Jung Han Hwang
Department of Radiology, Gil Medical Center, Gachon University College of Medicine, Incheon, Korea
3 shared publications - So Hyun Park
Department of Radiology, Gil Medical Center, Gachon University College of Medicine, Incheon, Korea
3 shared publications - Suyoung Park
Department of Radiology, Gil Medical Center, Gachon University College of Medicine, Incheon, Korea
3 shared publications - Bernhard Schmidt
Department of Computed Tomography, Siemens Healthcare, Forchheim, Germany
1 shared publication Ji Hoon Shin
Univ Ulsan, Coll Med, Asan Med Ctr, Dept Radiol, Seoul, South Korea
1 shared publication
Latest Publications
- Open Access
- 12 January 2023
- Published by Galenos Yayinevi in Diagnostic and Interventional Radiology
- Vol. 29 (1) , 175-182
Advanced virtual monoenergetic imaging algorithm for lower extremity computed tomography angiography: effects on image quality, artifacts, and peripheral arterial disease evaluation
PURPOSE To investigate the image quality of lower extremity computed tomography angiography (LE-CTA) using a reconstruction algorithm for monoenergetic images (MEIs) to evaluate peripheral arterial disease (PAD) at different kiloelectron volt (keV) levels. METHODS A total of 146 consecutive patients who underwent LE-CTA on a dual-energy scanner to obtain MEIs at 40, 50, 60, 70, and 80 keV were included. The overall image quality, segmental image quality of the arteries and PAD segments, venous contamination, and metal artifacts from prostheses, which may compromise quality, were analyzed. RESULTS The mean overall image quality of each MEI was 2.9 +/- 0.7, 3.6 +/- 0.6, 3.9 +/- 0.3, 4.0 +/- 0.2, and 4.0 +/- 0.2 from 40 to 80 keV, respectively. The segmental image quality gradually increased from 40 to 70-80 keV until reaching its highest value. Among 295 PAD segments in 68 patients, 40 (13.6%) were scored at 1-2 at 40 keV and 13 (4.4%) were scored at 2 at 50 keV, indicating unsatisfactory image quality due to the indistinguishability between high-contrast areas and arterial calcifications. The segments exhibiting metal artifacts and venous contamination were reduced at 70-80 keV (2.6 +/- 1.2, 2.7 +/- 0.5) compared with at 40 keV (2.4 +/- 1.1, 2.5 +/- 0.7). CONCLUSION The LE-CTA method using a reconstruction algorithm for MEIs at 70-80 keV can enhance the image quality for PAD evaluation and improve mitigate venous contamination and metal artifacts.
- 12 January 2023
- Published by Galenos Yayinevi in Diagnostic and Interventional Radiology
- Vol. 29 (1) , 175-182
Open AccessAdvanced virtual monoenergetic imaging algorithm for lower extremity computed tomography angiography: effects on image quality, artifacts, and peripheral arterial disease evaluation
PURPOSE To investigate the image quality of lower extremity computed tomography angiography (LE-CTA) using a reconstruction algorithm for monoenergetic images (MEIs) to evaluate peripheral arterial disease (PAD) at different kiloelectron volt (keV) levels. METHODS A total of 146 consecutive patients who underwent LE-CTA on a dual-energy scanner to obtain MEIs at 40, 50, 60, 70, and 80 keV were included. The overall image quality, segmental image quality of the arteries and PAD segments, venous contamination, and metal artifacts from prostheses, which may compromise quality, were analyzed. RESULTS The mean overall image quality of each MEI was 2.9 +/- 0.7, 3.6 +/- 0.6, 3.9 +/- 0.3, 4.0 +/- 0.2, and 4.0 +/- 0.2 from 40 to 80 keV, respectively. The segmental image quality gradually increased from 40 to 70-80 keV until reaching its highest value. Among 295 PAD segments in 68 patients, 40 (13.6%) were scored at 1-2 at 40 keV and 13 (4.4%) were scored at 2 at 50 keV, indicating unsatisfactory image quality due to the indistinguishability between high-contrast areas and arterial calcifications. The segments exhibiting metal artifacts and venous contamination were reduced at 70-80 keV (2.6 +/- 1.2, 2.7 +/- 0.5) compared with at 40 keV (2.4 +/- 1.1, 2.5 +/- 0.7). CONCLUSION The LE-CTA method using a reconstruction algorithm for MEIs at 70-80 keV can enhance the image quality for PAD evaluation and improve mitigate venous contamination and metal artifacts.
- Open Access
- 25 September 2022
- Published by The Korean Society of Radiology in Journal of the Korean Society of Radiology
- Vol. 83 (5) , 1032-1045
Imaging Findings of Peripheral Arterial Disease on Lower-Extremity CT Angiography Using a Virtual Monoenergetic Imaging Algorithm
김준성, et al. J Korean Soc Radiol. 2022 Sep;83(5):1032-1045. https://doi.org/10.3348/jksr.2021.0191
- 25 September 2022
- Published by The Korean Society of Radiology in Journal of the Korean Society of Radiology
- Vol. 83 (5) , 1032-1045
Open AccessImaging Findings of Peripheral Arterial Disease on Lower-Extremity CT Angiography Using a Virtual Monoenergetic Imaging Algorithm
김준성, et al. J Korean Soc Radiol. 2022 Sep;83(5):1032-1045. https://doi.org/10.3348/jksr.2021.0191
- Open Access
- 16 June 2021
- Published by The Korean Society of Radiology in Journal of the Korean Society of Radiology
- Vol. 82 (4) , 851-861
Imaging Features and Interventional Treatment for Liver Injuries and Their Complications
유성현, et al. J Korean Soc Radiol. 2021 Jun;82:e76. https://doi.org/10.3348/jksr.2020.0157
- 16 June 2021
- Published by The Korean Society of Radiology in Journal of the Korean Society of Radiology
- Vol. 82 (4) , 851-861
Open AccessImaging Features and Interventional Treatment for Liver Injuries and Their Complications
유성현, et al. J Korean Soc Radiol. 2021 Jun;82:e76. https://doi.org/10.3348/jksr.2020.0157