RERobert A. Eder

Robert A. Eder

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Robert A. Eder has a total of 50 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Contrast‐Enhanced Cardiac Magnetic Resonance Imaging With a Manganese‐Based Alternative to Gadolinium for Tissue Characterization of Acute Myocardial Infarction

    by Benjamin P. Bonner, Salva R. Yurista, Jaume Coll‐Font, Shi Chen, Robert A. Eder, Anna N. Foster, Khoi D. Nguyen, Peter Caravan, Eric M. Gale, Christopher Nguyen

    Background: Late gadolinium enhancement cardiac magnetic resonance imaging is an effective and reproducible method for characterizing myocardial infarction. However, gadolinium‐based contrast agents are contraindicated in patients with acute and chronic renal insufficiency. In addition, several recent studies have noted tissue deposition of free gadolinium in patients who have undergone serial contrast‐enhanced magnetic resonance imaging. There is a clinical need for alternative forms of magnetic resonance imaging contrast agents that are acceptable in the setting of renal insufficiency. Methods and Results: Three days after 80 minutes of ischemia/reperfusion of the left anterior descending coronary artery, cardiac magnetic resonance imaging was performed to assess myocardial lesion burden using both contrast agents. Late gadolinium enhancement cardiac magnetic resonance imaging was examined 10 and 15 minutes after contrast injection. Contrast agents were administered in alternating manner with a 2‐ to 3‐hour washout period between contrast agent injections. Lesion evaluation and image processing were performed using Segment Medviso software. Mean infarct size and transmurality, measured using RVP‐001, were not different compared with those measured using late gadolinium enhancement images. Bland‐Altman analysis demonstrated a nominal bias of 0.13 mL (<1% of average total lesion volume) for RVP‐001 in terms of gross infarct size measurement. Conclusions: The experimental manganese‐based contrast agent RVP‐001 appears to be an effective agent for assessment of myocardial infarction location, size, and transmurality, and it may be useful as an alternative to gadolinium‐based agents.


  • A soft robotic sleeve mimicking the haemodynamics and biomechanics of left ventricular pressure overload and aortic stenosis

    by Luca Rosalia, Caglar Ozturk, Jaume Coll-Font, Yiling Fan, Yasufumi Nagata, Manisha Singh, Debkalpa Goswami, Adam Mauskapf, Shi Chen, Robert A. Eder, et al.

    Preclinical models of aortic stenosis can induce left ventricular pressure overload and coarsely control the severity of aortic constriction. However, they do not recapitulate the haemodynamics and flow patterns associated with the disease. Here we report the development of a customizable soft robotic aortic sleeve that can mimic the haemodynamics and biomechanics of aortic stenosis. By allowing for the adjustment of actuation patterns and blood-flow dynamics, the robotic sleeve recapitulates clinically relevant haemodynamics in a porcine model of aortic stenosis, as we show via in vivo echocardiography and catheterization studies, and a combination of in vitro and computational analyses. Using in vivo and in vitro magnetic resonance imaging, we also quantified the four-dimensional blood-flow velocity profiles associated with the disease and with bicommissural and unicommissural defects re-created by the robotic sleeve. The design of the sleeve, which can be adjusted on the basis of computed tomography data, allows for the design of patient-specific devices that may guide clinical decisions and improve the management and treatment of patients with aortic stenosis.


  • Open Access

    Author Correction: Exercise-induced CITED4 expression is necessary for regional remodeling of cardiac microstructural tissue helicity

    by Robert A. Eder, Maaike van Den Boomen, Salva R. Yurista, Yaiel G. Rodriguez-Aviles, Mohammad Rashedul Islam, Yin-Ching Iris Chen, Lena Trager, Jaume Coll-Font, Leo Cheng, Haobo Li, et al.


  • Magnetic resonance imaging of cardiac metabolism in heart failure: how far have we come?

    by Salva R Yurista, Robert A Eder, Deborah H Kwon, Christian T Farrar, Yi Fen Yen, W H Wilson Tang, Christopher T Nguyen

    As one of the highest energy consumer organs in the body, the heart requires tremendous amount of adenosine triphosphate (ATP) to maintain its continuous mechanical work. Fatty acids, glucose, and ketone bodies are the primary fuel source of the heart to generate ATP with perturbations in ATP generation possibly leading to contractile dysfunction. Cardiac metabolic imaging with magnetic resonance imaging (MRI) plays a crucial role in understanding the dynamic metabolic changes occurring in the failing heart, where the cardiac metabolism is deranged. Also, targeting and quantifying metabolic changes in vivo noninvasively is a promising approach to facilitate diagnosis, determine prognosis, and evaluate therapeutic response. Here, we summarize novel MRI techniques used for detailed investigation of cardiac metabolism in heart failure including magnetic resonance spectroscopy (MRS), hyperpolarized MRS, and chemical exchange saturation transfer based on evidence from preclinical and clinical studies and to discuss the potential clinical application in heart failure.


  • Open Access

    Exercise-induced CITED4 expression is necessary for regional remodeling of cardiac microstructural tissue helicity

    by Robert A. Eder, Maaike van Den Boomen, Salva R. Yurista, Yaiel G. Rodriguez-Aviles, Mohammad Rashedul Islam, Yin-Ching Iris Chen, Lena Trager, Jaume Coll-Font, Leo Cheng, Haobo Li, et al.

    Both exercise-induced molecular mechanisms and physiological cardiac remodeling have been previously studied on a whole heart level. However, the regional microstructural tissue effects of these molecular mechanisms in the heart have yet to be spatially linked and further elucidated. We show in exercised mice that the expression of CITED4, a transcriptional co-regulator necessary for cardioprotection, is regionally heterogenous in the heart with preferential significant increases in the lateral wall compared with sedentary mice. Concordantly in this same region, the heart’s local microstructural tissue helicity is also selectively increased in exercised mice. Quantification of CITED4 expression and microstructural tissue helicity reveals a significant correlation across both sedentary and exercise mouse cohorts. Furthermore, genetic deletion of CITED4 in the heart prohibits regional exercise-induced microstructural helicity remodeling. Taken together, CITED4 expression is necessary for exercise-induced regional remodeling of the heart’s microstructural helicity revealing how a key molecular regulator of cardiac remodeling manifests into downstream local tissue-level changes.


  • Accelerated in Vivo Cardiac Diffusion-Tensor MRI Using Residual Deep Learning–based Denoising in Participants with Obesity

    by Kellie Phipps, Maaike van de Boomen, Robert Eder, Sam Allen Michelhaugh, Aferdita Spahillari, Joan Kim, Shestruma Parajuli, Timothy G. Reese, Choukri Mekkaoui, Saumya Das, et al.

    A deep learning denoising algorithm was developed to accelerate diffusion-tensor MRI (DT-MRI) data acquisition to preserve image quality and cardiac DT-MRI parameter quantification. Purpose To develop and assess a residual deep learning algorithm to accelerate in vivo cardiac diffusion-tensor MRI (DT-MRI) by reducing the number of averages while preserving image quality and DT...