Michael Skutek
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Michael Skutek has a total of 74 co-authors. Here are the top co-authors by number of shared publications:
U. Bosch
Labor für Histologie und Zellbiologie, Unfallchirurgische Klinik, Medizinische Hochschule Hannover
11 shared publications- Martijn van Griensven
Department of Cell Biology-Inspired Tissue Engineering, MERLN Institute for Technology-Inspired Regenerative Medicine, Maastricht University, Maastricht, The Netherlands
8 shared publications Ulrich Bosch
Laboratory of Histology and Cell Biology Department of Traumasurgery Hannover Medical School Hannover Germany
8 shared publicationsJohannes Zeichen
7 shared publicationsJ. Zeichen
Labor für Histologie und Zellbiologie, Unfallchirurgische Klinik, Medizinische Hochschule Hannover
4 shared publications- Nils Wirries
Department of Orthopaedic Surgery At Diakovere Annastift (Hannover Medical School), Hannover, Germany
4 shared publications
Latest Publications
- Open Access
- 13 July 2021
- Published by Hindawi Limited in Case Reports in Orthopedics
- Vol. 2021, 1-4
One-Stage Implant-Retaining Revision for Simultaneous Bilateral Infected Total Knee Arthroplasty: A Report of a Rare Case
There is little information on the management of simultaneous infected total knee arthroplasties in the same patient. Although general principles of management for periprosthetic joint infection apply, there might be certain aspects worth to be considered. We present a case of a 78-year-old patient, who was referred in preseptic conditions 10 years following bilateral TKA. The onset of symptoms was less than one week, proposing an acute hematogenous infection. Analysis of joint fluid revealed that both of his TKAs were infected with Streptococcus sanguinis. Diagnostic algorithms, surgical principles, and the course of the patients following bilateral revision are being described. The reasons for an implant-retaining procedure with irrigation and debridement including the exchange of the polyethylene liners are being discussed as well as possible principles of management of bilateral periprosthetic joint infections.
- 13 July 2021
- Published by Hindawi Limited in Case Reports in Orthopedics
- Vol. 2021, 1-4
Open AccessOne-Stage Implant-Retaining Revision for Simultaneous Bilateral Infected Total Knee Arthroplasty: A Report of a Rare Case
There is little information on the management of simultaneous infected total knee arthroplasties in the same patient. Although general principles of management for periprosthetic joint infection apply, there might be certain aspects worth to be considered. We present a case of a 78-year-old patient, who was referred in preseptic conditions 10 years following bilateral TKA. The onset of symptoms was less than one week, proposing an acute hematogenous infection. Analysis of joint fluid revealed that both of his TKAs were infected with Streptococcus sanguinis. Diagnostic algorithms, surgical principles, and the course of the patients following bilateral revision are being described. The reasons for an implant-retaining procedure with irrigation and debridement including the exchange of the polyethylene liners are being discussed as well as possible principles of management of bilateral periprosthetic joint infections.
- 1 September 2020
- Published by Elsevier in Journal of Orthopaedics
- Vol. 21, 10-13
Proceeding from direct lateral to anterolateral approach in total hip arthroplasty: A closer look on radiological and clinical aspects
- 1 September 2020
- Published by Elsevier in Journal of Orthopaedics
- Vol. 21, 10-13
Proceeding from direct lateral to anterolateral approach in total hip arthroplasty: A closer look on radiological and clinical aspects
- Open Access
- 22 April 2020
- Published by Open Medical Publishing in Orthopedic Reviews
- Vol. 12 (1) , 8-11
Allogenic bone graft for femoral defect augmentation in hip revision arthroplasty: A case series
Cortical bone loss in revision hip arthroplasty requires an adequate stabilization to achieve a durable implant fixation. This case series shall illustrate possible indications for the use of allogenic grafts in revision hip arthroplasty. Twelve patients with femoral bone loss were treated with allografts. In addition to established clinical scores, the radiological follow-ups were analyzed for hints of implants loosening and the osteointegration of the allografts. After a mean follow-up of 3.0 years the mHHS was 61.3 points and the UCLA 3.8. One patient showed a non-progressive radiolucency around the hip implant. The osteointegration of all allogenic grafts happened on time. Up to the last follow-up no revision surgery of the hip implants and the associated femoral bone graft was observed. Allogenic bone grafts present a method for biological stabilization in situations of large femoral cortical bone defects in revision hip arthroplasty.
- 22 April 2020
- Published by Open Medical Publishing in Orthopedic Reviews
- Vol. 12 (1) , 8-11
Open AccessAllogenic bone graft for femoral defect augmentation in hip revision arthroplasty: A case series
Cortical bone loss in revision hip arthroplasty requires an adequate stabilization to achieve a durable implant fixation. This case series shall illustrate possible indications for the use of allogenic grafts in revision hip arthroplasty. Twelve patients with femoral bone loss were treated with allografts. In addition to established clinical scores, the radiological follow-ups were analyzed for hints of implants loosening and the osteointegration of the allografts. After a mean follow-up of 3.0 years the mHHS was 61.3 points and the UCLA 3.8. One patient showed a non-progressive radiolucency around the hip implant. The osteointegration of all allogenic grafts happened on time. Up to the last follow-up no revision surgery of the hip implants and the associated femoral bone graft was observed. Allogenic bone grafts present a method for biological stabilization in situations of large femoral cortical bone defects in revision hip arthroplasty.
- 1 September 2019
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 34 (9) , 2022-2029
Osteointegrative Sleeves for Metaphyseal Defect Augmentation in Revision Total Knee Arthroplasty: Clinical and Radiological 5-Year Follow-Up
- 1 September 2019
- Published by Elsevier in The Journal of Arthroplasty
- Vol. 34 (9) , 2022-2029
Osteointegrative Sleeves for Metaphyseal Defect Augmentation in Revision Total Knee Arthroplasty: Clinical and Radiological 5-Year Follow-Up
- Open Access
- 27 June 2016
- Published by Open Medical Publishing in Orthopedic Reviews
- Vol. 8 (2) , 6379
Hip arthroplasty in obese patients: rising prevalence – standard procedures?
We examined our experience and, in particular, complications associated with total hip arthroplasty in obese and morbidly obese patients. We prospectively gathered 50 patients in a matched control series including 25 obese and morbidly obese patients. All patients were operated using the direct lateral approach and standard postoperative protocols. Operating room time, complications, dislocations, blood loss, cup position and clinical parameters using the Harris Hip Score and the Western Ontario and McMaster Universities Arthritis Index results were compared. Although there were some significant differences in clinical outcomes, standard procedures yielded good overall results and an acceptable rate of complications. Details approaching this patient entity are being discussed.
- 27 June 2016
- Published by Open Medical Publishing in Orthopedic Reviews
- Vol. 8 (2) , 6379
Open AccessHip arthroplasty in obese patients: rising prevalence – standard procedures?
We examined our experience and, in particular, complications associated with total hip arthroplasty in obese and morbidly obese patients. We prospectively gathered 50 patients in a matched control series including 25 obese and morbidly obese patients. All patients were operated using the direct lateral approach and standard postoperative protocols. Operating room time, complications, dislocations, blood loss, cup position and clinical parameters using the Harris Hip Score and the Western Ontario and McMaster Universities Arthritis Index results were compared. Although there were some significant differences in clinical outcomes, standard procedures yielded good overall results and an acceptable rate of complications. Details approaching this patient entity are being discussed.
- 8 December 2012
- Published by Springer Nature in Zeitschrift für Rheumatologie
- Vol. 72 (3) , 270-278
Synovialitis vom arthrofibrotischen Typ
- 8 December 2012
- Published by Springer Nature in Zeitschrift für Rheumatologie
- Vol. 72 (3) , 270-278
Synovialitis vom arthrofibrotischen Typ
- 29 April 2011
- Published by Springer Nature in Der Pathologe
- Vol. 32 (3) , 210-219
Gelenkendoprothesenpathologie
- 29 April 2011
- Published by Springer Nature in Der Pathologe
- Vol. 32 (3) , 210-219
Gelenkendoprothesenpathologie
- 1 April 2007
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 89 (4) , 814-818
The Twenty to Twenty-five-Year Outcomes of the Harris Design-2 Matte-Finished Cemented Total Hip Replacement
We previously reported the ten to fifteen-year results for 195 matte-finished Harris Design-2 total hip replacements that had been inserted with cement by two surgeons in 166 patients with osteoarthritis. The purpose of the present report is to update that study and report the twenty to twenty-five-year outcomes. The patients were followed prospectively on the basis of clinical assessment with use of the Harris hip score and radiographic analysis. One hundred and forty-nine patients (90%) had a functioning implant at the time of death or, if living, at twenty to twenty-five years of follow-up. A total of ten patients (ten hips; 5%) underwent a revision because of aseptic loosening of the acetabular component (two hips; 1%), the femoral component (four hips; 2%), or both components (four hips; 2%). At twenty-five years, Kaplan-Meier analysis revealed a survival rate of 83% ± 6% with revision for any reason as the end point. The survival rate was 86% ± 6% for the femoral component and 93% ± 3% for the acetabular component with aseptic loosening as the end point. Level of Evidence: Therapeutic Level IV. See Instructions to Authors for a complete description of levels of evidence.
- 1 April 2007
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 89 (4) , 814-818
The Twenty to Twenty-five-Year Outcomes of the Harris Design-2 Matte-Finished Cemented Total Hip Replacement
We previously reported the ten to fifteen-year results for 195 matte-finished Harris Design-2 total hip replacements that had been inserted with cement by two surgeons in 166 patients with osteoarthritis. The purpose of the present report is to update that study and report the twenty to twenty-five-year outcomes. The patients were followed prospectively on the basis of clinical assessment with use of the Harris hip score and radiographic analysis. One hundred and forty-nine patients (90%) had a functioning implant at the time of death or, if living, at twenty to twenty-five years of follow-up. A total of ten patients (ten hips; 5%) underwent a revision because of aseptic loosening of the acetabular component (two hips; 1%), the femoral component (four hips; 2%), or both components (four hips; 2%). At twenty-five years, Kaplan-Meier analysis revealed a survival rate of 83% ± 6% with revision for any reason as the end point. The survival rate was 86% ± 6% for the femoral component and 93% ± 3% for the acetabular component with aseptic loosening as the end point. Level of Evidence: Therapeutic Level IV. See Instructions to Authors for a complete description of levels of evidence.
- 1 January 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2, 8 pp.
A precrash system based on sensor data fusion of laser scanner and short range radars
The growing interest toward active safety systems leads to a rapid development of different sensors and systems. One key aspect for all systems is the knowledge about the car environment. This knowledge is essential for safety applications such as PreCrash. A PreCrash system generates information about location, moving direction and relative velocity of critical objects in the car environment immediately before an imminent and inevitable accident happens. Different types of actuators can benefit from this information for in-time deployment and the choice of the right deployment energy. In this paper a PreCrash system is proposed, which uses two short range radars and a laser scanner to obtain the required environmental data. The short range radars and the laser scanner will be mounted in the front of a test vehicle. The sensors are able to observe multiple targets within a field of view in front of the car. To develop a highly reliable environment sensing system, competitive fusion approaches using different types of sensors are appropriate. The challenge in realizing such a fusion system is the optimal utilization of the detection performance of each sensor type and the developing of a fast architecture for using it in the automotive environment. As two examples for such a fusion strategy a commonly utilized decision level fusion approach is discussed and a newly developed grid fusion approach is introduced. It is based on a virtual grid in front of the car in which the sensor readings are mapped into. The architecture of the grid is directly adapted to the requirements of the application and the sensor specifications. The data extraction out of the grid is based on simple and well known strategies. Decision strategies to increase the certainty of object identity are also proposed in this paper.
- 1 January 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2, 8 pp.
A precrash system based on sensor data fusion of laser scanner and short range radars
The growing interest toward active safety systems leads to a rapid development of different sensors and systems. One key aspect for all systems is the knowledge about the car environment. This knowledge is essential for safety applications such as PreCrash. A PreCrash system generates information about location, moving direction and relative velocity of critical objects in the car environment immediately before an imminent and inevitable accident happens. Different types of actuators can benefit from this information for in-time deployment and the choice of the right deployment energy. In this paper a PreCrash system is proposed, which uses two short range radars and a laser scanner to obtain the required environmental data. The short range radars and the laser scanner will be mounted in the front of a test vehicle. The sensors are able to observe multiple targets within a field of view in front of the car. To develop a highly reliable environment sensing system, competitive fusion approaches using different types of sensors are appropriate. The challenge in realizing such a fusion system is the optimal utilization of the detection performance of each sensor type and the developing of a fast architecture for using it in the automotive environment. As two examples for such a fusion strategy a commonly utilized decision level fusion approach is discussed and a newly developed grid fusion approach is introduced. It is based on a virtual grid in front of the car in which the sensor readings are mapped into. The architecture of the grid is directly adapted to the requirements of the application and the sensor specifications. The data extraction out of the grid is based on simple and well known strategies. Decision strategies to increase the certainty of object identity are also proposed in this paper.
- 1 May 2004
- Published by Wiley in Arthroscopy
- Vol. 20 (5) , 469-473
Screening for arthrofibrosis after anterior cruciate ligament reconstruction: Analysis of association with human leukocyte antigen
Purpose: Arthrofibrosis represents a severe complication of trauma and reconstructive joint surgery because of generalized connective tissue proliferation resulting in painful joint stiffness. It often appears stereotypical in terms of its clinical and pathologic features, comprising excess deposition of extracellular matrix proteins such as collagen type I, III, and VI and proliferation of fibroblasts. However, trauma and surgery around joints does not always lead to fibrosis, suggesting a genetic predisposition. For a number of autoimmune diseases, strong associations have been described. The objective of the study was to investigate whether an association of HLA (human leukocyte antigen) with primary arthrofibrosis exists. Type of Study: Retrospective cohort study. Methods: Seventeen patients with primary arthrofibrosis after autologous anterior cruciate ligament (ACL) reconstruction were identified and clinically reviewed. Blood samples were taken, and DNA was isolated by column extraction method. DNA samples were typed for the loci HLA‐A, ‐B, ‐C, ‐DRB1, and ‐DQB1. Results were compared with the frequencies of allelic groups as determined for the caucasoid population. Results: HLA‐Cw∗07 was significantly less often found in the patient group than in the general population ( P = .022). The opposite effect was seen for Cw∗08, which was found in 17.6% of the patient group but only in 3.8% of the reference group ( P = .045). A significant difference was also seen for DQB1∗06, because 23.5% of the patients but 48.6% of the reference group possessed an allelic variant of this group ( P = .048). However, according to the relatively small number of patients, a statistical bias cannot be excluded. Conclusions: A possible link may exist between arthrofibrosis and HLA‐Cw∗07‐ and DQB1∗06‐negative as well as Cw∗08‐positive individuals. Further investigation is necesessary to confirm or vitiate the possible association. Level of Evidence: Level IV.
- 1 May 2004
- Published by Wiley in Arthroscopy
- Vol. 20 (5) , 469-473
Screening for arthrofibrosis after anterior cruciate ligament reconstruction: Analysis of association with human leukocyte antigen
Purpose: Arthrofibrosis represents a severe complication of trauma and reconstructive joint surgery because of generalized connective tissue proliferation resulting in painful joint stiffness. It often appears stereotypical in terms of its clinical and pathologic features, comprising excess deposition of extracellular matrix proteins such as collagen type I, III, and VI and proliferation of fibroblasts. However, trauma and surgery around joints does not always lead to fibrosis, suggesting a genetic predisposition. For a number of autoimmune diseases, strong associations have been described. The objective of the study was to investigate whether an association of HLA (human leukocyte antigen) with primary arthrofibrosis exists. Type of Study: Retrospective cohort study. Methods: Seventeen patients with primary arthrofibrosis after autologous anterior cruciate ligament (ACL) reconstruction were identified and clinically reviewed. Blood samples were taken, and DNA was isolated by column extraction method. DNA samples were typed for the loci HLA‐A, ‐B, ‐C, ‐DRB1, and ‐DQB1. Results were compared with the frequencies of allelic groups as determined for the caucasoid population. Results: HLA‐Cw∗07 was significantly less often found in the patient group than in the general population ( P = .022). The opposite effect was seen for Cw∗08, which was found in 17.6% of the patient group but only in 3.8% of the reference group ( P = .045). A significant difference was also seen for DQB1∗06, because 23.5% of the patients but 48.6% of the reference group possessed an allelic variant of this group ( P = .048). However, according to the relatively small number of patients, a statistical bias cannot be excluded. Conclusions: A possible link may exist between arthrofibrosis and HLA‐Cw∗07‐ and DQB1∗06‐negative as well as Cw∗08‐positive individuals. Further investigation is necesessary to confirm or vitiate the possible association. Level of Evidence: Level IV.