Ana Lores-Padín
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ana Lores-Padín has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Beatriz Fernández
Department of Physical and Analytical Chemistry, University of Oviedo, Julián Clavería 8, 33006 Oviedo, Spain
5 shared publications - Héctor González-Iglesias
Instituto de Productos Lácteos de Asturias, Consejo Superior de Investigaciones Científicas (IPLA-CSIC), Oviedo, Spain; Instituto de Investigación Sanitaria del Principado de Asturias (ISPA), Oviedo, Spain
5 shared publications - Frank Vanhaecke
Atomic & Mass Spectrometry-A&MS Research Group, Department of Chemistry, Ghent University, Campus Sterre, Krijgslaan 281-S12, 9000 Ghent, Belgium
4 shared publications - Rosario Pereiro
University of Oviedo
4 shared publications Olivier De Wever
Ghent University
3 shared publications- Thibaut Van Acker
Ghent University Campus SterreBuilding S12, De Pintelaan 270
3 shared publications
Latest Publications
- 19 November 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
Assessing the Representativeness of Cell Sampling in Single Cell-ICP-MS Using Ru-Based Cell Size Markers and LA-ICP-MS
Single cell-inductively coupled plasma-time-of-flightmass spectrometry (SC-ICP-TOF-MS) enables high-throughput quantitative assay of endogenous and exogenous elements in individual cells. However, the low transport efficiency, inversely proportional to the cell size, raises a question: does SC-ICP-MS provide representative sampling of the original cell population, or are smaller cells preferentially measured? In this work, the occurrence and degree of size-dependent sampling bias were evaluated using laser ablation (LA)-ICP-TOF-MS, which enables cell size determination prior to analysis and achieves 100% cell transport efficiency. First, tagging protocols with Ruthenium red (RR) and ASCQ_Ruthenium (ASCQ_Ru) were thoroughly optimized to enable cell size estimation in SC-ICP-MS. To verify that both tags accurately capture size information, an automated LA-ICP-MS data processing pipeline was developed, revealing that the optically measured cell size distribution can be reliably predicted solely from the Ru cell content. This was verified across 4 distinct human cell types of different sizes (10−40 μm) and by analyzing up to 1000 cells per sample. While both tags successfully revealed cell size, ASCQ_Ru produced cleaner transient signals and did not influence the content of endogenous elements (i.e., P, S, Ca, Fe, Cu and Zn), whereas RR produced low-intensity non-cellular events and induced partial losses of Ca and Zn. Finally, the comparison of cell sizes based on LA-SC-ICP-MS and SC-ICP-MS revealed the existence of a slight size-dependent bias with a higher fraction of large cells observed by the former. These findings should be accounted for when developing novel SC-ICP-MS applications to ensure that reliable information is obtained.
- 19 November 2026
- Published by American Chemical Society (ACS) in Analytical Chemistry
Assessing the Representativeness of Cell Sampling in Single Cell-ICP-MS Using Ru-Based Cell Size Markers and LA-ICP-MS
Single cell-inductively coupled plasma-time-of-flightmass spectrometry (SC-ICP-TOF-MS) enables high-throughput quantitative assay of endogenous and exogenous elements in individual cells. However, the low transport efficiency, inversely proportional to the cell size, raises a question: does SC-ICP-MS provide representative sampling of the original cell population, or are smaller cells preferentially measured? In this work, the occurrence and degree of size-dependent sampling bias were evaluated using laser ablation (LA)-ICP-TOF-MS, which enables cell size determination prior to analysis and achieves 100% cell transport efficiency. First, tagging protocols with Ruthenium red (RR) and ASCQ_Ruthenium (ASCQ_Ru) were thoroughly optimized to enable cell size estimation in SC-ICP-MS. To verify that both tags accurately capture size information, an automated LA-ICP-MS data processing pipeline was developed, revealing that the optically measured cell size distribution can be reliably predicted solely from the Ru cell content. This was verified across 4 distinct human cell types of different sizes (10−40 μm) and by analyzing up to 1000 cells per sample. While both tags successfully revealed cell size, ASCQ_Ru produced cleaner transient signals and did not influence the content of endogenous elements (i.e., P, S, Ca, Fe, Cu and Zn), whereas RR produced low-intensity non-cellular events and induced partial losses of Ca and Zn. Finally, the comparison of cell sizes based on LA-SC-ICP-MS and SC-ICP-MS revealed the existence of a slight size-dependent bias with a higher fraction of large cells observed by the former. These findings should be accounted for when developing novel SC-ICP-MS applications to ensure that reliable information is obtained.
- 17 October 2026
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1427
Advancing LA-ICP-TOF-MS multi-elemental mapping: The bidirectional scanning approach
- 17 October 2026
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1427
Advancing LA-ICP-TOF-MS multi-elemental mapping: The bidirectional scanning approach
- Open Access
- 6 October 2025
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 40 (11) , 3192-3209
LA-ICP-TOF-MS for quantitative mapping of biogenic carbonate samples using matrix-matched nanoparticulate pressed powder pellets
A robust methodology for high-resolution, quantitative multi-elemental 2D-mapping of carbonate samples using LA-ICP-TOF-MS with nano-pellets as matrix-matched standards was developed for unlocking new insights into sclerochronological studies.
- 6 October 2025
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 40 (11) , 3192-3209
Open AccessLA-ICP-TOF-MS for quantitative mapping of biogenic carbonate samples using matrix-matched nanoparticulate pressed powder pellets
A robust methodology for high-resolution, quantitative multi-elemental 2D-mapping of carbonate samples using LA-ICP-TOF-MS with nano-pellets as matrix-matched standards was developed for unlocking new insights into sclerochronological studies.
- Open Access
- 27 June 2022
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1221, 340128
Real matrix-matched standards for quantitative bioimaging of cytosolic proteins in individual cells using metal nanoclusters as immunoprobes-label: A case study using laser ablation ICP-MS detection
- 27 June 2022
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1221, 340128
Open AccessReal matrix-matched standards for quantitative bioimaging of cytosolic proteins in individual cells using metal nanoclusters as immunoprobes-label: A case study using laser ablation ICP-MS detection
- Open Access
- 9 March 2022
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1203, 339701
Gold nanoclusters as elemental label for the sequential quantification of apolipoprotein E and metallothionein 2A in individual human cells of the retinal pigment epithelium using single cell-ICP-MS
- 9 March 2022
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1203, 339701
Open AccessGold nanoclusters as elemental label for the sequential quantification of apolipoprotein E and metallothionein 2A in individual human cells of the retinal pigment epithelium using single cell-ICP-MS
- 19 October 2019
- Published by Springer Nature in Microchimica Acta
- Vol. 186 (11) , 705
Bimodal determination of immunoglobulin E by fluorometry and ICP-MS by using platinum nanoclusters as a label in an immunoassay
The authors describe the use of platinum nanoclusters (PtNCs) as bimodal labels in a competitive immunoassay for immunoglobulin E (IgE). Both fluorometry and inductively coupled plasma – mass spectrometry (ICP-MS) are used. Optimization of the PtNCs synthesis using lipoic acid as ligand was carried out. The time for synthesis and the effect of NaOH added to the PtNCs precursor mixture was optimized with the aim to obtain PtNCs with strong red fluorescence and low size dispersity. Maximal fluorescence was obtained at excitation/emission wavelengths of 455/620 nm. The average diameter (1.5 nm) and crystal structure (face-centered cubic structure) of the PtNCs were determined by HR-TEM. It was calculated that each PtNC contains 116 Pt atoms at average. Labelling of the antibody (Ab) against IgE with PtNCs was optimized in terms of recognition capabilities and fluorescence intensity. A molar ratio (Ab:PtNCs) of 1:11 is found to be best. A competitive immunoassay for IgE was developed and detection was carried out by using both ICP-MS (by measuring 195Pt) and fluorometry. The limit of detection (LOD) of the fluoroimmunoassay is 0.6 ng mL−1 of IgE. The LOD of the ICP-MS method is as low as 0.08 ng mL−1. The method was evaluated by analyzing four (spiked) serum samples by ICP-MS. No sample pretreatment excepting dilution is needed. Results compared favorably with those obtained by a commercial ELISA kit.
- 19 October 2019
- Published by Springer Nature in Microchimica Acta
- Vol. 186 (11) , 705
Bimodal determination of immunoglobulin E by fluorometry and ICP-MS by using platinum nanoclusters as a label in an immunoassay
The authors describe the use of platinum nanoclusters (PtNCs) as bimodal labels in a competitive immunoassay for immunoglobulin E (IgE). Both fluorometry and inductively coupled plasma – mass spectrometry (ICP-MS) are used. Optimization of the PtNCs synthesis using lipoic acid as ligand was carried out. The time for synthesis and the effect of NaOH added to the PtNCs precursor mixture was optimized with the aim to obtain PtNCs with strong red fluorescence and low size dispersity. Maximal fluorescence was obtained at excitation/emission wavelengths of 455/620 nm. The average diameter (1.5 nm) and crystal structure (face-centered cubic structure) of the PtNCs were determined by HR-TEM. It was calculated that each PtNC contains 116 Pt atoms at average. Labelling of the antibody (Ab) against IgE with PtNCs was optimized in terms of recognition capabilities and fluorescence intensity. A molar ratio (Ab:PtNCs) of 1:11 is found to be best. A competitive immunoassay for IgE was developed and detection was carried out by using both ICP-MS (by measuring 195Pt) and fluorometry. The limit of detection (LOD) of the fluoroimmunoassay is 0.6 ng mL−1 of IgE. The LOD of the ICP-MS method is as low as 0.08 ng mL−1. The method was evaluated by analyzing four (spiked) serum samples by ICP-MS. No sample pretreatment excepting dilution is needed. Results compared favorably with those obtained by a commercial ELISA kit.