D. A. Zavalishin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
D. A. Zavalishin has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
M. Yu. Belyaev
Korolev Rocket and Space Corporation Energiya
4 shared publicationsV. V. Sazonov
Russian Academy of Sciences
4 shared publicationsA. F. Glukhov
Perm State University
2 shared publicationsA. I. Ivanov
Central Scientific Research Institute of Machine Building
2 shared publicationsG. F. Putin
Perm State University
2 shared publicationsI. A. Babushkin
Perm State University
2 shared publications
Latest Publications
- 22 July 2017
- Published by Pleiades Publishing Ltd in Cosmic Research
- Vol. 55 (4) , 263-269
Experiments with the DAKON-M convection sensor
We have described an express technique for processing the results of experiments with a DAKON-M convection sensor on board the Service Module of the International Space Station (ISS) in 2011. The technique uses a certain rule to compare the sensor measurements with the calculated data on the quasistatic component of microacceleration at the point of installation. The sensor experiments have been conducted during shuttle docking and undocking, when low-frequency microaccelerations on the ISS were significant. The microaccelerations have been calculated using measurement data of the MAMS low-frequency accelerometer installed in the Lab module and the telemetry data on the ISS rotational motion. This has made it possible to convert the MAMS measurement data to the DAKON-M convection sensor installation point. A comparison of sensor readings with calculated microaccelerations has revealed fairly good agreement between them.
- 22 July 2017
- Published by Pleiades Publishing Ltd in Cosmic Research
- Vol. 55 (4) , 263-269
Experiments with the DAKON-M convection sensor
We have described an express technique for processing the results of experiments with a DAKON-M convection sensor on board the Service Module of the International Space Station (ISS) in 2011. The technique uses a certain rule to compare the sensor measurements with the calculated data on the quasistatic component of microacceleration at the point of installation. The sensor experiments have been conducted during shuttle docking and undocking, when low-frequency microaccelerations on the ISS were significant. The microaccelerations have been calculated using measurement data of the MAMS low-frequency accelerometer installed in the Lab module and the telemetry data on the ISS rotational motion. This has made it possible to convert the MAMS measurement data to the DAKON-M convection sensor installation point. A comparison of sensor readings with calculated microaccelerations has revealed fairly good agreement between them.
- 1 January 2017
- Published by Akademizdatcenter Nauka in Kosmičeskie issledovaniâ
- No. 4,p. 278-284
ЭКСПЕРИМЕНТЫ С ДАТЧИКОМ КОНВЕКЦИИ ДАКОН-М, "Космические исследования"
- 1 January 2017
- Published by Akademizdatcenter Nauka in Kosmičeskie issledovaniâ
- No. 4,p. 278-284
ЭКСПЕРИМЕНТЫ С ДАТЧИКОМ КОНВЕКЦИИ ДАКОН-М, "Космические исследования"
- 19 July 2013
- Published by Pleiades Publishing Ltd in Cosmic Research
- Vol. 51 (4) , 261-269
Study of vibration microaccelerations onboard the International Space Station
The results of studying vibration microaccelerations aboard the International Space Station are presented. The study was performed using the measurement data of the MAMS low-frequency and the SAMS high-frequency accelerometers. For the study, six intervals of measurements were selected, performed in 2005. During these intervals the station was flying in the standard orbital orientation, attitude control engines were not switched on, and the crew rested. Discrete and continuous spectra were analyzed on selected intervals. The most significant disturbances with the discrete spectrum (cyclic trends) have been found. Using the second order autoregression model, parameters of the most significant disturbances with the continuous spectrum were determined. This study was carried out as a part of the technical experiment “The ISS environment”.
- 19 July 2013
- Published by Pleiades Publishing Ltd in Cosmic Research
- Vol. 51 (4) , 261-269
Study of vibration microaccelerations onboard the International Space Station
The results of studying vibration microaccelerations aboard the International Space Station are presented. The study was performed using the measurement data of the MAMS low-frequency and the SAMS high-frequency accelerometers. For the study, six intervals of measurements were selected, performed in 2005. During these intervals the station was flying in the standard orbital orientation, attitude control engines were not switched on, and the crew rested. Discrete and continuous spectra were analyzed on selected intervals. The most significant disturbances with the discrete spectrum (cyclic trends) have been found. Using the second order autoregression model, parameters of the most significant disturbances with the continuous spectrum were determined. This study was carried out as a part of the technical experiment “The ISS environment”.
- 1 January 2013
- Published by Akademizdatcenter Nauka in Kosmičeskie issledovaniâ
- Vol. 51 (4) , 294-302
Исследование вибрационных микроускорений на бортуМеждународной космической станции
- 1 January 2013
- Published by Akademizdatcenter Nauka in Kosmičeskie issledovaniâ
- Vol. 51 (4) , 294-302
Исследование вибрационных микроускорений на бортуМеждународной космической станции
- 28 September 2012
- Published by Pleiades Publishing Ltd in Cosmic Research
- Vol. 50 (5) , 346-352
Study of microaccelerations onboard the International Space Station with the DAKON-M convection sensor
The results of experiments with the DAKON-M convection sensor onboard the Russian orbital segment of the International Space Station are described. A comparison of the sensor measurements with the results of calculation of the quasistatic microacceleration component at the point of installation is made. For this comparison we have used three measurement intervals of the experiments in 2009, during which spacecraft were docked with the station, undocked from it, and actuation of jet engines of the attitude control system took place. When calculating microacceleration, we use the measurement data of the low-frequency MAMS accelerometer, installed on the American segment, and the telemetry data on the ISS rotational motion. This information allowed one to convert the MAMS measurements to the point of installation of the DAKON-M convection sensor. A comparison of sensor measurements with calculated microaccelerations showed sufficiently accurate coincidence between the calculated and measured data.
- 28 September 2012
- Published by Pleiades Publishing Ltd in Cosmic Research
- Vol. 50 (5) , 346-352
Study of microaccelerations onboard the International Space Station with the DAKON-M convection sensor
The results of experiments with the DAKON-M convection sensor onboard the Russian orbital segment of the International Space Station are described. A comparison of the sensor measurements with the results of calculation of the quasistatic microacceleration component at the point of installation is made. For this comparison we have used three measurement intervals of the experiments in 2009, during which spacecraft were docked with the station, undocked from it, and actuation of jet engines of the attitude control system took place. When calculating microacceleration, we use the measurement data of the low-frequency MAMS accelerometer, installed on the American segment, and the telemetry data on the ISS rotational motion. This information allowed one to convert the MAMS measurements to the point of installation of the DAKON-M convection sensor. A comparison of sensor measurements with calculated microaccelerations showed sufficiently accurate coincidence between the calculated and measured data.
- 3 August 2010
- Published by Pleiades Publishing Ltd in Cosmic Research
- Vol. 48 (4) , 352-361
Determination of characteristic frequencies of elastic oscillations of the International Space Station construction
The results of investigating free oscillations of the International Space Station construction appearing during spacecraft docking and undocking are described. The study is carried out using the measurement data of the low-frequency MAMS accelerometer. Several intervals of measurements performed in 2005 and 2006 were chosen to be studied. For chosen intervals, only the data intervals corresponding to the process of free attenuation of the oscillations construction elements were analyzed. Characteristic frequencies of elastic oscillations of the station construction and attenuation coefficients corresponding to them are found. The comparative analysis of the results obtained for various docking ports (nodes) is carried out. The described study is performed as a part of the technical experiment “The ISS Environment” carried out onboard the station in accordance with the Russian program of scientific and engineering experiments.
- 3 August 2010
- Published by Pleiades Publishing Ltd in Cosmic Research
- Vol. 48 (4) , 352-361
Determination of characteristic frequencies of elastic oscillations of the International Space Station construction
The results of investigating free oscillations of the International Space Station construction appearing during spacecraft docking and undocking are described. The study is carried out using the measurement data of the low-frequency MAMS accelerometer. Several intervals of measurements performed in 2005 and 2006 were chosen to be studied. For chosen intervals, only the data intervals corresponding to the process of free attenuation of the oscillations construction elements were analyzed. Characteristic frequencies of elastic oscillations of the station construction and attenuation coefficients corresponding to them are found. The comparative analysis of the results obtained for various docking ports (nodes) is carried out. The described study is performed as a part of the technical experiment “The ISS Environment” carried out onboard the station in accordance with the Russian program of scientific and engineering experiments.
- 23 April 2009
- Published by Pleiades Publishing Ltd in Cosmic Research
- Vol. 47 (2) , 173-184
Estimation of dynamic characteristics of the International Space Station from measurements of microaccelerations
We describe the results of determining the mass of the International Space Station using the data of MAMS accelerometer taken during correction of the station orbit on August 20, 2004. The correction was made by approach and attitude control engines (ACE) of the Progress transporting spacecraft. The engines were preliminary calibrated in an autonomous flight using the onboard device for measuring apparent velocity increment. The method of calibration is described and its results are presented. The error in station mass determination is about 1%. The same data of MAMS and similar data obtained during the orbit correction on August 26, 2004 were used for the analysis of high-frequency vibrations of the station mainframe caused by operation of the ACE of Progress. Natural frequencies of the ACE are determined. They lie in the frequency band 0.024–0.11 Hz. ACE operation is demonstrated to result in a substantial increase of microaccelerations onboard the station in the frequency range 0–1 Hz. The frequencies are indicated at which disturbances increase by more than an order of magnitude. The study described was carried out as a part of the Tensor technological experiment.
- 23 April 2009
- Published by Pleiades Publishing Ltd in Cosmic Research
- Vol. 47 (2) , 173-184
Estimation of dynamic characteristics of the International Space Station from measurements of microaccelerations
We describe the results of determining the mass of the International Space Station using the data of MAMS accelerometer taken during correction of the station orbit on August 20, 2004. The correction was made by approach and attitude control engines (ACE) of the Progress transporting spacecraft. The engines were preliminary calibrated in an autonomous flight using the onboard device for measuring apparent velocity increment. The method of calibration is described and its results are presented. The error in station mass determination is about 1%. The same data of MAMS and similar data obtained during the orbit correction on August 26, 2004 were used for the analysis of high-frequency vibrations of the station mainframe caused by operation of the ACE of Progress. Natural frequencies of the ACE are determined. They lie in the frequency band 0.024–0.11 Hz. ACE operation is demonstrated to result in a substantial increase of microaccelerations onboard the station in the frequency range 0–1 Hz. The frequencies are indicated at which disturbances increase by more than an order of magnitude. The study described was carried out as a part of the Tensor technological experiment.