Suyane Maria Luna-Cruz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Suyane Maria Luna-Cruz has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Bruno Carvalho de Vasconcelos
Post-graduate Program in Dentistry, Faculty of Pharmacy, Dentistry and Nursing, Federal University of Ceará, Fortaleza, CE, Brazil
5 shared publications - Marco Antonio Hungaro Duarte
University of São Paulo
4 shared publications - Bernardo Almeida Aguiar
Department of Endodontics, Faculty of Dentistry, University of Fortaleza, 587 Dr. Valmir Pontes Avenue, Edson Queiroz, Fortaleza, Ceará, 60812-020, Brazil
3 shared publications - Rodrigo Ricci Vivan
University of São Paulo
3 shared publications - Joana Lia Freitas Furtado
Federal University of Ceará Fortaleza Ceará Brazil
2 shared publications - Mirlyn de Souza Dias
Postgraduate Program in Dentistry, Federal University of Ceará, 1273 Monsenhor Furtado St., Rodolfo Teófilo, Fortaleza 60455-730, CE, Brazil
2 shared publications
Latest Publications
- Open Access
Modified Formulations of Silicate-Based Cements: Comparative Study of Physicochemical Properties
This study aimed to prepare experimental calcium silicate repair cements (ERCs) incorporating zirconium (Ca3ZrSi2O9; CZS) or strontium substitution (Sr5(PO4)2SiO4; SPS), and to compare their physicochemical properties with white MTA-Angelus (WMTA), grey MTA-Angelus (GMTA), and Biodentine (BD). After synthesizing the CZS and SPS phases, powder–liquid cements were formulated. The setting time and radiopacity were assessed according to ISO 6876/12 and ASTM C266, the volumetric solubility by micro-CT, the pH by a pH meter, and the calcium/strontium ion release by FAAS/ICP-OES. Data were analyzed using ANOVA and Tukey’s tests (5%). The initial setting time was 11 min for SPS and 6 min for CZS (p < 0.05), while the final setting was significantly longer for SPS (49 min). Both ERCs showed radiopacity above the 3.0 mm Al minimum, with higher values for CZS (4.58 mm Al). The solubility remained controlled, with CZS presenting the highest value (3.09%). Both materials exhibited an alkaline pH, peaking at 24 h (CZS: 9.70; SPS: 10.04) and decreasing until 168 h (CZS: 7.80; SPS: 8.31). Sustained ionic release was observed: CZS showed intermediate calcium release (25.96 mg/L at 3 h), whereas SPS displayed lower values (10.95 mg/L at 168 h), without significant difference from WMTA (p > 0.05). Under these conditions, the experimental ERCs demonstrated adequate physicochemical performance comparable with commercial materials.
Open AccessModified Formulations of Silicate-Based Cements: Comparative Study of Physicochemical Properties
This study aimed to prepare experimental calcium silicate repair cements (ERCs) incorporating zirconium (Ca3ZrSi2O9; CZS) or strontium substitution (Sr5(PO4)2SiO4; SPS), and to compare their physicochemical properties with white MTA-Angelus (WMTA), grey MTA-Angelus (GMTA), and Biodentine (BD). After synthesizing the CZS and SPS phases, powder–liquid cements were formulated. The setting time and radiopacity were assessed according to ISO 6876/12 and ASTM C266, the volumetric solubility by micro-CT, the pH by a pH meter, and the calcium/strontium ion release by FAAS/ICP-OES. Data were analyzed using ANOVA and Tukey’s tests (5%). The initial setting time was 11 min for SPS and 6 min for CZS (p < 0.05), while the final setting was significantly longer for SPS (49 min). Both ERCs showed radiopacity above the 3.0 mm Al minimum, with higher values for CZS (4.58 mm Al). The solubility remained controlled, with CZS presenting the highest value (3.09%). Both materials exhibited an alkaline pH, peaking at 24 h (CZS: 9.70; SPS: 10.04) and decreasing until 168 h (CZS: 7.80; SPS: 8.31). Sustained ionic release was observed: CZS showed intermediate calcium release (25.96 mg/L at 3 h), whereas SPS displayed lower values (10.95 mg/L at 168 h), without significant difference from WMTA (p > 0.05). Under these conditions, the experimental ERCs demonstrated adequate physicochemical performance comparable with commercial materials.
- 20 November 2025
- Published by Sciencedomain International in Journal of Advances in Medicine and Medical Research
- Vol. 37 (12) , 176-186
Use of Endoguide in Accessing a Calcified Maxillary Canine Using CBCT Guided: A Case Report
Aims: To describe the endodontic treatment of a tooth with extensive calcification in the pulp chamber, using the guided endodontic technique (Endoguide). Case Report: A 36-year-old female patient, with normal systemic function, presented to the Dental Clinic of UFC - Sobral Campus for evaluation. After anamnesis, clinical and radiographic examinations, endodontic treatment was deemed necessary for tooth 13, which presented with necrosis and periapical rarefaction. The same radiographic examination identified that the tooth presented with pulpal calcification extending to the middle third of the root. As a complementary examination, a cone-beam computed tomography scan was requested, which guided the fabrication of the guide. With this guide and the aid of a specific drill operated at low speed, access to the root canal was achieved without major difficulties. Odontometry and instrumentation of the canal were then performed with instruments from the Reciproc system (R25 and R40); subsequently, calcium hydroxide paste was applied and remained in place for 21 days. The root canal obturation was performed with Hydro Sealer endodontic cement and gutta-percha using the modified Tagger Hybrid technique. Conclusion: The Endoguide proved to be an efficient and easy-to-use tool, acting as a facilitator during the endodontic treatment of the reported case, minimizing the risk of accidents and increasing the predictability of the procedure.
- 20 November 2025
- Published by Sciencedomain International in Journal of Advances in Medicine and Medical Research
- Vol. 37 (12) , 176-186
Use of Endoguide in Accessing a Calcified Maxillary Canine Using CBCT Guided: A Case Report
Aims: To describe the endodontic treatment of a tooth with extensive calcification in the pulp chamber, using the guided endodontic technique (Endoguide). Case Report: A 36-year-old female patient, with normal systemic function, presented to the Dental Clinic of UFC - Sobral Campus for evaluation. After anamnesis, clinical and radiographic examinations, endodontic treatment was deemed necessary for tooth 13, which presented with necrosis and periapical rarefaction. The same radiographic examination identified that the tooth presented with pulpal calcification extending to the middle third of the root. As a complementary examination, a cone-beam computed tomography scan was requested, which guided the fabrication of the guide. With this guide and the aid of a specific drill operated at low speed, access to the root canal was achieved without major difficulties. Odontometry and instrumentation of the canal were then performed with instruments from the Reciproc system (R25 and R40); subsequently, calcium hydroxide paste was applied and remained in place for 21 days. The root canal obturation was performed with Hydro Sealer endodontic cement and gutta-percha using the modified Tagger Hybrid technique. Conclusion: The Endoguide proved to be an efficient and easy-to-use tool, acting as a facilitator during the endodontic treatment of the reported case, minimizing the risk of accidents and increasing the predictability of the procedure.
- 1 November 2025
- Published by Sciencedomain International in Archives of Current Research International
- Vol. 25 (11) , 77-85
Effect of Three Endodontic Sealers and Ultrasonic Agitation on Tooth Discoloration: An in vitro Study
Aims: To evaluate the color change (ΔE) induced by the endodontic cements: Endofill (EF), Sealer 26 (S26) and MTA Fillapex (MTAF); as well as to investigate the impact of ultrasonic agitation (UA) on the degree of discoloration produced. Methodology: Sixty bovine incisor blocks were prepared, in which circular cavities were created on the palatal surfaces, preserving a 2.0 mm thick dentin remnant. The specimens were distributed into six groups according to the endodontic cement and treatment employed. When present, ultrasonic agitation (UA) was performed using a smooth insert coupled to a piezoelectric device. Color parameter measurements were obtained using a Vita Easyshade spectrophotometer immediately after material insertion and restoration (T0), and subsequently at 7 (T1), 30 (T2), 60 (T3), 90 (T4), and 180 days (T5). Throughout the experimental period, the specimens remained immersed in 2 mL of saline solution and stored in an incubator at 37 °C. The statistical analysis of the data was conducted using the Kruskal-Wallis and Dunn tests, adopting a significance level of 5%. Results: It was found that, at 7 and 30 days, only the Endofill (EF) group without ultrasonic agitation (UA) exhibited ΔE values greater than 3.7 (the limit considered clinically perceptible for color change). After 60 days, all cements evaluated showed ΔE above this threshold, indicating perceptible discoloration in all groups. Comparative analysis revealed statistically significant differences in discoloration among Endofill, Sealer 26 and MTA Fillapex, indicating that color alteration progressed consistently over time (P < 0.05). Conclusion: The results of this study showed that, although only Endofill (EF) cement exhibited a perceptible color change in the initial periods, by the end of the evaluation all materials tested showed some degree of darkening. Furthermore, the use of ultrasonic agitation (UA) did not have a significant impact on the observed color variations.
- 1 November 2025
- Published by Sciencedomain International in Archives of Current Research International
- Vol. 25 (11) , 77-85
Effect of Three Endodontic Sealers and Ultrasonic Agitation on Tooth Discoloration: An in vitro Study
Aims: To evaluate the color change (ΔE) induced by the endodontic cements: Endofill (EF), Sealer 26 (S26) and MTA Fillapex (MTAF); as well as to investigate the impact of ultrasonic agitation (UA) on the degree of discoloration produced. Methodology: Sixty bovine incisor blocks were prepared, in which circular cavities were created on the palatal surfaces, preserving a 2.0 mm thick dentin remnant. The specimens were distributed into six groups according to the endodontic cement and treatment employed. When present, ultrasonic agitation (UA) was performed using a smooth insert coupled to a piezoelectric device. Color parameter measurements were obtained using a Vita Easyshade spectrophotometer immediately after material insertion and restoration (T0), and subsequently at 7 (T1), 30 (T2), 60 (T3), 90 (T4), and 180 days (T5). Throughout the experimental period, the specimens remained immersed in 2 mL of saline solution and stored in an incubator at 37 °C. The statistical analysis of the data was conducted using the Kruskal-Wallis and Dunn tests, adopting a significance level of 5%. Results: It was found that, at 7 and 30 days, only the Endofill (EF) group without ultrasonic agitation (UA) exhibited ΔE values greater than 3.7 (the limit considered clinically perceptible for color change). After 60 days, all cements evaluated showed ΔE above this threshold, indicating perceptible discoloration in all groups. Comparative analysis revealed statistically significant differences in discoloration among Endofill, Sealer 26 and MTA Fillapex, indicating that color alteration progressed consistently over time (P < 0.05). Conclusion: The results of this study showed that, although only Endofill (EF) cement exhibited a perceptible color change in the initial periods, by the end of the evaluation all materials tested showed some degree of darkening. Furthermore, the use of ultrasonic agitation (UA) did not have a significant impact on the observed color variations.
- 6 December 2024
- Published by Wiley in Australian Endodontic Journal
- Vol. 51 (1) , 103-114
In vitro evaluation of the influence of ultrasonic activation on physicochemical properties of three endodontic repair materials
The influence of ultrasonic activation (UA) on the physicochemical properties of setting time (n = 5), volumetric stability (n = 10), alkalizing activity/calcium ions release (pH/Ca2+) (n = 10) and calcium/phosphate‐rich substance formation in simulated body fluid (Hank's balanced salt solution; HBSS) of three cements was evaluated: white MTA‐Angelus (MTA), MTA Repair HP (MTAHP) and Biodentine (BIO). It was observed that UA influenced the setting times (min) distinctly, delaying the initial setting time of MTA (40.8/64.6) and accelerating that of BIO (35.6/22.4). The final setting time of MTAHP (154.4/114.6) and BIO (64.4/42.4) were also accelerated (p < 0.05). Volumetric reduction was observed in all groups, with MTA/UA being the most volumetrically stable (0.98%); UA did not influence volumetric stability (p > 0.05). All groups exhibited an alkaline pH, with a disadvantage for MTAHP and MTAHP/UA at 24 h, 72 h and 168 h (p < 0.05). All groups showed Ca2+ release. The tested cements exhibited a favourable Ca/P ratio on their surface after 28 days.
- 6 December 2024
- Published by Wiley in Australian Endodontic Journal
- Vol. 51 (1) , 103-114
In vitro evaluation of the influence of ultrasonic activation on physicochemical properties of three endodontic repair materials
The influence of ultrasonic activation (UA) on the physicochemical properties of setting time (n = 5), volumetric stability (n = 10), alkalizing activity/calcium ions release (pH/Ca2+) (n = 10) and calcium/phosphate‐rich substance formation in simulated body fluid (Hank's balanced salt solution; HBSS) of three cements was evaluated: white MTA‐Angelus (MTA), MTA Repair HP (MTAHP) and Biodentine (BIO). It was observed that UA influenced the setting times (min) distinctly, delaying the initial setting time of MTA (40.8/64.6) and accelerating that of BIO (35.6/22.4). The final setting time of MTAHP (154.4/114.6) and BIO (64.4/42.4) were also accelerated (p < 0.05). Volumetric reduction was observed in all groups, with MTA/UA being the most volumetrically stable (0.98%); UA did not influence volumetric stability (p > 0.05). All groups exhibited an alkaline pH, with a disadvantage for MTAHP and MTAHP/UA at 24 h, 72 h and 168 h (p < 0.05). All groups showed Ca2+ release. The tested cements exhibited a favourable Ca/P ratio on their surface after 28 days.
- Open Access
- 1 January 2024
- Published by FapUNIFESP (SciELO) in Brazilian Oral Research
- Vol. 38, e136
Physicochemical properties of silicate tricalcium-based cement for use as pulp capping or repair material
This study evaluated some physicochemical properties of an experimental tricalcium silicate-based cement (ETSC) indicated for use as pulp capping or endodontic repair material; Biodentine (BD) and White MTA-Angelus (MTA) cements served as comparators. Setting time, radiopacity, sorption, and solubility were determined according to ISO 6876/2012 and compressive strength according to ISO 9917-1/2019. pH and calcium ion release capacity were also assessed. Data were analyzed using ANOVA and Tukey tests or Kruskal-Wallis and Dunn tests with α = 0.05. BD (15’) and ETSC (17.3’) exhibited the shortest initial setting times, with BD (29’) having the shortest final setting time; MTA showed longer times in both analyses (p < 0.05). ETSC and MTA showed the highest radiopacity (6.1 mm Al and 5.7 mm Al), while BD showed the lowest (3.0 mm Al) (p < 0.05). BD exhibited the highest compressive strength (88.8 MPa), significantly higher than the others (p < 0.05). BD presented the lowest values for sorption, 0.12% (24 h) and 0.48% (28 d), which differed significantly from MTA (p < 0.05). The lowest values for solubility were shown for ETSC, 0.26% (24 h), and BD, 0.52% (28 d), which differed significantly from MTA (p2+ analysis, BD provided the highest values in all periods; differences were only significant compared to MTA (3h/24h) (p <0 .05). Considering the study conditions, it can be concluded that ETSC exhibited characteristics similar or better properties than the commercial cements tested, except for compressive strength.
- 1 January 2024
- Published by FapUNIFESP (SciELO) in Brazilian Oral Research
- Vol. 38, e136
Open AccessPhysicochemical properties of silicate tricalcium-based cement for use as pulp capping or repair material
This study evaluated some physicochemical properties of an experimental tricalcium silicate-based cement (ETSC) indicated for use as pulp capping or endodontic repair material; Biodentine (BD) and White MTA-Angelus (MTA) cements served as comparators. Setting time, radiopacity, sorption, and solubility were determined according to ISO 6876/2012 and compressive strength according to ISO 9917-1/2019. pH and calcium ion release capacity were also assessed. Data were analyzed using ANOVA and Tukey tests or Kruskal-Wallis and Dunn tests with α = 0.05. BD (15’) and ETSC (17.3’) exhibited the shortest initial setting times, with BD (29’) having the shortest final setting time; MTA showed longer times in both analyses (p < 0.05). ETSC and MTA showed the highest radiopacity (6.1 mm Al and 5.7 mm Al), while BD showed the lowest (3.0 mm Al) (p < 0.05). BD exhibited the highest compressive strength (88.8 MPa), significantly higher than the others (p < 0.05). BD presented the lowest values for sorption, 0.12% (24 h) and 0.48% (28 d), which differed significantly from MTA (p < 0.05). The lowest values for solubility were shown for ETSC, 0.26% (24 h), and BD, 0.52% (28 d), which differed significantly from MTA (p2+ analysis, BD provided the highest values in all periods; differences were only significant compared to MTA (3h/24h) (p <0 .05). Considering the study conditions, it can be concluded that ETSC exhibited characteristics similar or better properties than the commercial cements tested, except for compressive strength.
- Open Access
- 10 June 2021
- Published by Research, Society and Development in Research, Society and Development
- Vol. 10 (7)
Análise do pH e da atividade antimicrobiana de um novo medicamento intracanal biocerâmico Bio-C Temp
As medicações intracanais com atividade antimicrobiana são importantes como coadjuvantes na desinfecção do sistema de canais radiculares. Diante disso, esse estudo avaliou, in vitro, o pH e a atividade antimicrobiana de um novo medicamento intracanal biocerâmico (Bio-C Temp) em comparação com medicações a base de hidróxido de cálcio (HC). A determinação do pH foi realizada por meio de um pHmetro nos períodos de 30 minutos, 3, 24, 72 e 168 horas. As medicações Ultracal®XS, Hidróxido de cálcio com soro (HC/Soro), Hidróxido de cálcio com propilenoglicol (HC/PG) e Bio-C Temp (biocerâmico) foram testadas contra biofilmes de duas cepas de Enterococcus faecalis (ATCCs 29212 e 4083) usando os testes de contato direto (TCD) e restrito por membrana (TRM). A sobrevivência bacteriana foi determinada pela contagem das unidades formadoras de colônias (UFCs) e os dados foram comparados estatisticamente (P < 0,05). A pasta Bio-C Temp apresentou o menor valor de pH nos tempos avaliados. Os grupos HC/Soro e HC/PG apresentaram maior ação frente ao controle no TCD (P < 0,05) contra as duas cepas testadas. Ainda, o HC/PG mostrou maior atividade antibacteriana que o Bio-C Temp (P < 0,05). Todos os grupos apresentaram diferença ante o grupo controle no TRM contra a cepa 29212, e somente o HC/PG mostrou diferença significativa frente ao controle contra biofilmes da cepa 4083. O Bio-C Temp mostrou ação antibacteriana similar ao Ultracal®XS, no entanto apresentou menor ação em relação ao HC/PG. A pasta de hidróxido de cálcio associada com propilenoglicol mostrou vantagens em relação às demais testadas.
- 10 June 2021
- Published by Research, Society and Development in Research, Society and Development
- Vol. 10 (7)
Open AccessAnálise do pH e da atividade antimicrobiana de um novo medicamento intracanal biocerâmico Bio-C Temp
As medicações intracanais com atividade antimicrobiana são importantes como coadjuvantes na desinfecção do sistema de canais radiculares. Diante disso, esse estudo avaliou, in vitro, o pH e a atividade antimicrobiana de um novo medicamento intracanal biocerâmico (Bio-C Temp) em comparação com medicações a base de hidróxido de cálcio (HC). A determinação do pH foi realizada por meio de um pHmetro nos períodos de 30 minutos, 3, 24, 72 e 168 horas. As medicações Ultracal®XS, Hidróxido de cálcio com soro (HC/Soro), Hidróxido de cálcio com propilenoglicol (HC/PG) e Bio-C Temp (biocerâmico) foram testadas contra biofilmes de duas cepas de Enterococcus faecalis (ATCCs 29212 e 4083) usando os testes de contato direto (TCD) e restrito por membrana (TRM). A sobrevivência bacteriana foi determinada pela contagem das unidades formadoras de colônias (UFCs) e os dados foram comparados estatisticamente (P < 0,05). A pasta Bio-C Temp apresentou o menor valor de pH nos tempos avaliados. Os grupos HC/Soro e HC/PG apresentaram maior ação frente ao controle no TCD (P < 0,05) contra as duas cepas testadas. Ainda, o HC/PG mostrou maior atividade antibacteriana que o Bio-C Temp (P < 0,05). Todos os grupos apresentaram diferença ante o grupo controle no TRM contra a cepa 29212, e somente o HC/PG mostrou diferença significativa frente ao controle contra biofilmes da cepa 4083. O Bio-C Temp mostrou ação antibacteriana similar ao Ultracal®XS, no entanto apresentou menor ação em relação ao HC/PG. A pasta de hidróxido de cálcio associada com propilenoglicol mostrou vantagens em relação às demais testadas.