Ke Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ke Zhang has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Yanling Jia
College of Advanced Materials Engineering, Jiaxing Nanhu University, Jiaxing 314000, China
4 shared publications Jiajie Yu
Key Laboratory of Intelligent Sensing Materials and Chip Integration Technology of Zhejiang Province, Hangzhou Innovation Institute, Beihang University, Hangzhou 310052, People’s Republic of China
3 shared publicationsJie Yang
School of Energy & Power Engineering
3 shared publicationsSicheng Wu
Key Laboratory of Intelligent Sensing Materials and Chip Integration Technology of Zhejiang Province, Hangzhou Innovation Institute, Beihang University, Hangzhou 310052, People’s Republic of China
3 shared publicationsShuai Zhang
Key Laboratory of Intelligent Sensing Materials and Chip Integration Technology of Zhejiang Province Hangzhou Innovation Institute Beihang University Hangzhou 310052 P. R. China
2 shared publicationsChangbo Liu
Key Laboratory of Intelligent Sensing Materials and Chip Integration Technology of Zhejiang Province Hangzhou Innovation Institute Beihang University Hangzhou 310052 P. R. China
1 shared publication
Latest Publications
- Open Access
- 17 March 2025
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 15 (11) , 8764-8776
A facile and green one-step synthesis of Ag/reduced graphene oxide and its application in catalysts and SERS
Herein, we present a facile one-step approach for synthesizing Ag/reduced graphene oxide (Ag–rGO) through synchronous reduction and in situ coagulation of graphene oxide (GO) and silver nitrate (AgNO3) under a nitrogen atmosphere.
- 17 March 2025
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 15 (11) , 8764-8776
Open AccessA facile and green one-step synthesis of Ag/reduced graphene oxide and its application in catalysts and SERS
Herein, we present a facile one-step approach for synthesizing Ag/reduced graphene oxide (Ag–rGO) through synchronous reduction and in situ coagulation of graphene oxide (GO) and silver nitrate (AgNO3) under a nitrogen atmosphere.
- 8 March 2025
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 17 (11) , 16479-16488
A Soft Patch for Dynamic Myocardial Infarction Monitoring
Wearable electronics for cardiac monitoring have been widely developed in the field of routine vital sign monitoring and arrhythmia determination due to their convenience and continuity. However, there are very few reports on the demonstration of a stretchable multilead electrocardiogram (ECG) patch integrated with myocardial infarction (MI) location capability. Here, we first propose a wearable dynamic cardiac monitoring patch, which can acquire seven-lead ECG signals continuously. A novel stretchable bioelectrode is mounted on the patch, which is strain-insensitive in the 100% tensile strain range. Moreover, the bioelectrode maintains good adhesion to the skin at more than 0.4 N/cm. This soft and wireless multilead ECG patch is designed for long-term, all-round real-time cardiac monitoring. For MI classification, a machine learning model for MI identification and location is trained with accuracy (99.93%) and sensitivity (99.98%). In addition, we also propose a new framework for the automated annotation of MI abnormal segments, which simultaneously addresses the recognition of abnormal waveforms and the integration of interlead relationships. This study contributes to the realization of personalized medical monitoring and intervention as well as early warning for MI.
- 8 March 2025
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 17 (11) , 16479-16488
A Soft Patch for Dynamic Myocardial Infarction Monitoring
Wearable electronics for cardiac monitoring have been widely developed in the field of routine vital sign monitoring and arrhythmia determination due to their convenience and continuity. However, there are very few reports on the demonstration of a stretchable multilead electrocardiogram (ECG) patch integrated with myocardial infarction (MI) location capability. Here, we first propose a wearable dynamic cardiac monitoring patch, which can acquire seven-lead ECG signals continuously. A novel stretchable bioelectrode is mounted on the patch, which is strain-insensitive in the 100% tensile strain range. Moreover, the bioelectrode maintains good adhesion to the skin at more than 0.4 N/cm. This soft and wireless multilead ECG patch is designed for long-term, all-round real-time cardiac monitoring. For MI classification, a machine learning model for MI identification and location is trained with accuracy (99.93%) and sensitivity (99.98%). In addition, we also propose a new framework for the automated annotation of MI abnormal segments, which simultaneously addresses the recognition of abnormal waveforms and the integration of interlead relationships. This study contributes to the realization of personalized medical monitoring and intervention as well as early warning for MI.
- Open Access
- 10 April 2024
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 14 (17) , 11758-11770
A direct one-step synthesis of a smart graphene/silica nanocomposite and its application for improving the acid resistance and corrosion resistance properties of waterborne epoxy coatings
A smart BTA@SN-rGO nanocomposite was obtained via a one-step synthetic method and can provide remarkable long-term corrosion protection on metal.
- 10 April 2024
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 14 (17) , 11758-11770
Open AccessA direct one-step synthesis of a smart graphene/silica nanocomposite and its application for improving the acid resistance and corrosion resistance properties of waterborne epoxy coatings
A smart BTA@SN-rGO nanocomposite was obtained via a one-step synthetic method and can provide remarkable long-term corrosion protection on metal.
- 14 November 2023
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry C
- Vol. 11 (47) , 16757-16765
Industrially-friendly rapid printing of stretchable liquid metal circuits for patch-mode wearable healthcare devices
Gallium-based liquid metals stand out as promising candidate materials for constructing stretchable conductive paths in soft electronics, but they are limited by high-cost laboratorial means of processing and exhibit poor wettability with most substrates. Here, we demonstrate a rapid, economical and industrially-friendly pattern technology, sponge-roller assisted liquid metal printing (SALP), which divides, extracts, transfers and integrates liquid metal droplets for patterning by its 3D grid structure and external pressure. SALP also provides universal high-adhesion by selective regulation of Ga2O3. High resolution (<50 μm) and low resistance change stretchable circuits could be realized by SALP under a prestretched platform. In addition, a stretchable reflectance oximeter patch composed of SALP-prepared circuits and rigid sensors is fabricated to monitor oxygen saturation and heart rate by sticking to fingertips, wrists and earlobes. This indicates that SALP technology is very competitive for industrial high-throughput fabrication of stretchable circuit boards.
- 14 November 2023
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry C
- Vol. 11 (47) , 16757-16765
Industrially-friendly rapid printing of stretchable liquid metal circuits for patch-mode wearable healthcare devices
Gallium-based liquid metals stand out as promising candidate materials for constructing stretchable conductive paths in soft electronics, but they are limited by high-cost laboratorial means of processing and exhibit poor wettability with most substrates. Here, we demonstrate a rapid, economical and industrially-friendly pattern technology, sponge-roller assisted liquid metal printing (SALP), which divides, extracts, transfers and integrates liquid metal droplets for patterning by its 3D grid structure and external pressure. SALP also provides universal high-adhesion by selective regulation of Ga2O3. High resolution (<50 μm) and low resistance change stretchable circuits could be realized by SALP under a prestretched platform. In addition, a stretchable reflectance oximeter patch composed of SALP-prepared circuits and rigid sensors is fabricated to monitor oxygen saturation and heart rate by sticking to fingertips, wrists and earlobes. This indicates that SALP technology is very competitive for industrial high-throughput fabrication of stretchable circuit boards.
- 10 August 2023
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 56 (45) , 455103
An in-situ integrated material distinction sensor based on density and heat capacity
Material distinction via artificial intelligence (AI) has been studied extensively and demonstrates strong capacity. However, a high-performance sensor and accurate theoretical model remain necessary to assist AI in precise identification. Here, we developed an in-situ integrated material distinction sensor, which depends on the density (ρ) and heat capacity (C) of measured matter. The device is fabricated using an outer nickel (Ni) thermistor and an inner laser-induced graphene (LIG) heater on a polyimide substrate. When a sample is placed on the surface of the sensor and a certain voltage is applied to the LIG heater, the Ni thermistor will perceive the temperature changing trends, which can reflect the heat absorption and conduction ability of the placed material. Notably, finite element analysis was conducted and the simulation results are perfectly combined with the experimental results, which implied that the ρ and C of the sample together determined the temperature distribution, instead of the thermal conductivity (κ). By establishing a heat absorption model, each kind of material can be identified with a feature value. A novel sensor and corresponding physical model are provided to perceive the material properties, improving the range and accuracy of material identification based on a contact-mode sensing mechanism.
- 10 August 2023
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 56 (45) , 455103
An in-situ integrated material distinction sensor based on density and heat capacity
Material distinction via artificial intelligence (AI) has been studied extensively and demonstrates strong capacity. However, a high-performance sensor and accurate theoretical model remain necessary to assist AI in precise identification. Here, we developed an in-situ integrated material distinction sensor, which depends on the density (ρ) and heat capacity (C) of measured matter. The device is fabricated using an outer nickel (Ni) thermistor and an inner laser-induced graphene (LIG) heater on a polyimide substrate. When a sample is placed on the surface of the sensor and a certain voltage is applied to the LIG heater, the Ni thermistor will perceive the temperature changing trends, which can reflect the heat absorption and conduction ability of the placed material. Notably, finite element analysis was conducted and the simulation results are perfectly combined with the experimental results, which implied that the ρ and C of the sample together determined the temperature distribution, instead of the thermal conductivity (κ). By establishing a heat absorption model, each kind of material can be identified with a feature value. A novel sensor and corresponding physical model are provided to perceive the material properties, improving the range and accuracy of material identification based on a contact-mode sensing mechanism.
- 14 January 2022
- Published by Wiley in Chemnanomat
- Vol. 8 (4)
Ultrawide Range and High‐precision Temperature Monitoring based on NiO/Polyimide Hybrid Nanomaterials
The need for temperature observation appears in all aspects of our lives. With the development of science and technology, higher requirements are put forward for the combination of high‐accuracy and wide detection range of the sensor. In this study, a facile strategy method was developed to prepare a NiO slurry and realize a wide‐range and high‐precision thermistor based on NiO. By dispersing NiO nanoparticles in polyimide (PI) to afford the NiO slurry, a thermistor was obtained by spin coating, thermal curing, and electrode preparation, which can operate in a very wide range from 220 K to 470 K, as well as exhibited an outstanding thermal sensitivity (B) with a value exceeding 5400 K. Moreover, the sensor shows very high detection accuracy and can detect small temperature differences up to 0.05 K. Notably, through brushing the mixture onto the PI substrate or peeling off from the substrate, a flexible, or free‐stand sensor was obtained, which displayed great mechanical properties and stabilities. This allows the sensor to be used on various curved surfaces and other objects with complex shapes, which greatly increases potential applications and the scope of the temperature sensor.
- 14 January 2022
- Published by Wiley in Chemnanomat
- Vol. 8 (4)
Ultrawide Range and High‐precision Temperature Monitoring based on NiO/Polyimide Hybrid Nanomaterials
The need for temperature observation appears in all aspects of our lives. With the development of science and technology, higher requirements are put forward for the combination of high‐accuracy and wide detection range of the sensor. In this study, a facile strategy method was developed to prepare a NiO slurry and realize a wide‐range and high‐precision thermistor based on NiO. By dispersing NiO nanoparticles in polyimide (PI) to afford the NiO slurry, a thermistor was obtained by spin coating, thermal curing, and electrode preparation, which can operate in a very wide range from 220 K to 470 K, as well as exhibited an outstanding thermal sensitivity (B) with a value exceeding 5400 K. Moreover, the sensor shows very high detection accuracy and can detect small temperature differences up to 0.05 K. Notably, through brushing the mixture onto the PI substrate or peeling off from the substrate, a flexible, or free‐stand sensor was obtained, which displayed great mechanical properties and stabilities. This allows the sensor to be used on various curved surfaces and other objects with complex shapes, which greatly increases potential applications and the scope of the temperature sensor.
- 27 June 2021
- Published by Wiley in Advanced Materials Technologies
- Vol. 6 (9) , 2100262
Facile Fabrication of Robust and Reusable PDMS Supported Graphene Dry Electrodes for Wearable Electrocardiogram Monitoring
Graphene‐based epidermal dry electrodes have generated wide interests in electrocardiography (ECG) monitoring to screen cardiovascular diseases in time. Nevertheless, the poor stability, mechanical strength, and integration are significant obstacles hindering further product marketing of graphene electrodes in health care. Herein, robust, reusable, and patterned graphene‐based wearable dry electrodes are fabricated based on laser writing technology and supported by polydimethylsiloxane (PDMS) layers. After bending tests over 10 000 cycles and high‐power ultrasonic treatments (5 h), graphene/PDMS electrodes are demonstrated to have excellent stability and reusability for ECG recording. Taking the advantages of the designable and efficient CO2 laser production technique, a “staff‐shape” graphene electrode consisting of six chest‐lead electrodes and corresponding lead lines can be facilely customized and fabricated according to users’ somatotype to greatly simplify the acquisition procedure of 12‐lead ECG, realizing the acquisition of V1–V6 ECGs for all‐round cardiac monitoring. After thorough analysis of ECG patterns, the integrated chest electrode exhibits desirable sensitivity and reliability comparable to wet Ag/AgCl electrodes. The reusable graphene/PDMS electrodes are suitable for long‐term ECG monitoring and the integrated electrode presents a novel strategy to wearable 12‐ECG recording.
- 27 June 2021
- Published by Wiley in Advanced Materials Technologies
- Vol. 6 (9) , 2100262
Facile Fabrication of Robust and Reusable PDMS Supported Graphene Dry Electrodes for Wearable Electrocardiogram Monitoring
Graphene‐based epidermal dry electrodes have generated wide interests in electrocardiography (ECG) monitoring to screen cardiovascular diseases in time. Nevertheless, the poor stability, mechanical strength, and integration are significant obstacles hindering further product marketing of graphene electrodes in health care. Herein, robust, reusable, and patterned graphene‐based wearable dry electrodes are fabricated based on laser writing technology and supported by polydimethylsiloxane (PDMS) layers. After bending tests over 10 000 cycles and high‐power ultrasonic treatments (5 h), graphene/PDMS electrodes are demonstrated to have excellent stability and reusability for ECG recording. Taking the advantages of the designable and efficient CO2 laser production technique, a “staff‐shape” graphene electrode consisting of six chest‐lead electrodes and corresponding lead lines can be facilely customized and fabricated according to users’ somatotype to greatly simplify the acquisition procedure of 12‐lead ECG, realizing the acquisition of V1–V6 ECGs for all‐round cardiac monitoring. After thorough analysis of ECG patterns, the integrated chest electrode exhibits desirable sensitivity and reliability comparable to wet Ag/AgCl electrodes. The reusable graphene/PDMS electrodes are suitable for long‐term ECG monitoring and the integrated electrode presents a novel strategy to wearable 12‐ECG recording.