Wei Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Wei Li has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Sherif A. Sherif
Department of Mechanical and Aerospace Engineering, University of Florida , 1064 Center Drive, 181 NEB Building, Gainesville, FL 32611
3 shared publications - Yanlong Cao
Zhejiang University
2 shared publications Bangmin Li
Science and Technology on Thermal Energy and Power Laboratory, Wuhan 430205, China
1 shared publication- Binlin Dou
School of Energy and Power Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China
1 shared publication - David John Kukulka
Department of Mechanical Engineering, State University of New York College at Buffalo, 1300 Elmwood Avenue, Buffalo, NY 14222, USA
1 shared publication Desong Yang
Department of Energy Engineering, Zhejiang University, 38 Zheda Road, Hangzhou 310027, China
1 shared publication
Latest Publications
- 7 March 2024
- Published by ASME International in Journal of Solar Energy Engineering
- Vol. 146 (4) , 1-13
Flow Boiling Heat Transfer in Enhanced Tubes With Composite Structure
To fill the research gaps in the study of flow boiling on composite surfaces, four heat exchange tubes with different structures were investigated: an enhanced tube with herringbone teeth (EHT_HB), a tube with a dimple structure (EHT_DIM), a tube with a composite herringbone tooth/dimple structure (EHT_HB/DIM), and a smooth tube as a baseline for comparison purposes. The experimental conditions were set as follows: saturation temperature 6°C, mass flux 50-205 kg/(m2.s), and vapor quality 0.2-0.8. After confirming the validity of the experimental results, the effects of the mass flux on the flow boiling heat transfer and pressure drop characteristics were examined. Results showed that the flow boiling heat transfer coefficient and pressure drop increase with the increase of the mass flux and the vapor quality in the tested tubes. The EHT_HB/DIM tube was found to combine the advantages of the two structures and to have the highest heat transfer coefficient. The average value of the heat transfer coefficient was found to be 43.75% higher than that of the smooth tube. Also, the average flow boiling heat transfer coefficients of the EHT_HB and the EHT_DIM tubes were found to be 15% and 35% higher that of the smooth tube, respectively. From the perspective of the frictional pressure drop, it was found that the EHT_HB/DIM tube exhibited the maximum frictional pressure drop. The optimum working conditions of the enhanced tubes were determined by introducing a performance factor that captures the combined effects of heat transfer and pressure drop.
- 7 March 2024
- Published by ASME International in Journal of Solar Energy Engineering
- Vol. 146 (4) , 1-13
Flow Boiling Heat Transfer in Enhanced Tubes With Composite Structure
To fill the research gaps in the study of flow boiling on composite surfaces, four heat exchange tubes with different structures were investigated: an enhanced tube with herringbone teeth (EHT_HB), a tube with a dimple structure (EHT_DIM), a tube with a composite herringbone tooth/dimple structure (EHT_HB/DIM), and a smooth tube as a baseline for comparison purposes. The experimental conditions were set as follows: saturation temperature 6°C, mass flux 50-205 kg/(m2.s), and vapor quality 0.2-0.8. After confirming the validity of the experimental results, the effects of the mass flux on the flow boiling heat transfer and pressure drop characteristics were examined. Results showed that the flow boiling heat transfer coefficient and pressure drop increase with the increase of the mass flux and the vapor quality in the tested tubes. The EHT_HB/DIM tube was found to combine the advantages of the two structures and to have the highest heat transfer coefficient. The average value of the heat transfer coefficient was found to be 43.75% higher than that of the smooth tube. Also, the average flow boiling heat transfer coefficients of the EHT_HB and the EHT_DIM tubes were found to be 15% and 35% higher that of the smooth tube, respectively. From the perspective of the frictional pressure drop, it was found that the EHT_HB/DIM tube exhibited the maximum frictional pressure drop. The optimum working conditions of the enhanced tubes were determined by introducing a performance factor that captures the combined effects of heat transfer and pressure drop.
- 1 January 2024
- Published by Begell House Inc. Publishers in Journal of Enhanced Heat Transfer
- Vol. 31 (5) , 99-114
CONDENSATION HEAT TRANSFER IN SMOOTH AND THREE-DIMENSIONAL DIMPLED TUBES OF VARIOUS MATERIALS
The heat transfer and pressure drop of R410A and R32 within a smooth and an enhanced dimpled tube were measured for mass fluxes from 100 to 400 kg m-2 s-1, average vapor qualities between 0.2 and 0.8, and saturation temperatures between 35°C and 45°C. The test section was 2 meters in length, and the outer and inner diameters of the tube were 9.52 and 8.32 mm, respectively. The inner surface of the enhanced tube was dimpled. Three dimpled tubes and three smooth tubes, differing by material (copper, aluminum, and stainless steel) were tested to examine the material effect. The measured condensation heat transfer coefficient (HTC) for the copper smooth tube was 1.10 to 1.16 times higher than that of the aluminum, and likewise, between 1.19 and 1.31 times higher than that of the stainless-steel tube. Similarly, the condensation HTC for the copper dimpled tube was 1.06 to 1.15 times higher than that of the aluminum dimpled tube, and 1.26 to 1.38 times higher than that of stainless-steel dimpled tube. In general, and the condensation HTC for R32 was greater than that for R410A, mainly due to the greater liquid thermal conductivity of R32. Flow patterns were observed for different vapor qualities and used to establish corresponding heat transfer mechanisms. Finally, a new correlation for dimpled tubes was proposed based a modified smooth tube correlation, which predicted the measurements within an error band of 20%.
- 1 January 2024
- Published by Begell House Inc. Publishers in Journal of Enhanced Heat Transfer
- Vol. 31 (5) , 99-114
CONDENSATION HEAT TRANSFER IN SMOOTH AND THREE-DIMENSIONAL DIMPLED TUBES OF VARIOUS MATERIALS
The heat transfer and pressure drop of R410A and R32 within a smooth and an enhanced dimpled tube were measured for mass fluxes from 100 to 400 kg m-2 s-1, average vapor qualities between 0.2 and 0.8, and saturation temperatures between 35°C and 45°C. The test section was 2 meters in length, and the outer and inner diameters of the tube were 9.52 and 8.32 mm, respectively. The inner surface of the enhanced tube was dimpled. Three dimpled tubes and three smooth tubes, differing by material (copper, aluminum, and stainless steel) were tested to examine the material effect. The measured condensation heat transfer coefficient (HTC) for the copper smooth tube was 1.10 to 1.16 times higher than that of the aluminum, and likewise, between 1.19 and 1.31 times higher than that of the stainless-steel tube. Similarly, the condensation HTC for the copper dimpled tube was 1.06 to 1.15 times higher than that of the aluminum dimpled tube, and 1.26 to 1.38 times higher than that of stainless-steel dimpled tube. In general, and the condensation HTC for R32 was greater than that for R410A, mainly due to the greater liquid thermal conductivity of R32. Flow patterns were observed for different vapor qualities and used to establish corresponding heat transfer mechanisms. Finally, a new correlation for dimpled tubes was proposed based a modified smooth tube correlation, which predicted the measurements within an error band of 20%.
- 3 November 2023
- Published by ASME International in Journal of Solar Energy Engineering
- Vol. 146 (3) , 1-27
Condensation Heat Transfer Experiments of R410A and R32 in Horizontal Smooth and Enhanced Tubes
A horizontal smooth copper tube and two enhanced tubes (a dimpled tube and a diamond-shaped tube) with a length of 2 m and an outer diameter of 9.52 mm were studied in a two-phase condensation experiment using R410A and R32 as heat transfer working fluids. The condensation heat transfer performance of different heat transfer tubes at various mass fluxes ranging from 150 to 400 kg/(m2s) and different vapor qualities ranging from 0.8 to 0.2 was studied experimentally. For R410A, the heat transfer coefficients (HTCs) of the dimpled tube and the diamond-shaped tube were found to be 1.39-1.52 times and 1.30-1.35 times higher than those of the smooth tube, respectively. For R32, the HTCs were found to be 1.46-1.59 times higher for the dimpled tube and 1.26-1.35 times higher for the diamond-shaped tube than for the smooth tube. The diamond-shaped tube was found to be effective in directing the flow of the liquid phase and in thinning the liquid film thickness. The dimpled tube was found to promote droplet entrainment and disturbance. Both of those effects contributed to improving the HTCs in the two enhanced tubes investigated. The HTCs of R410A were found to be lower than those of R32 because of the smaller specific heat capacity, smaller latent heat of condensation, and relatively poorer thermal conductivity of R410A. Taking the combined effect of heat transfer and pressure drop into account, a performance enhancement factor (PEF) was computed and was found to range from 0.9 to 1.51. Based on the experimental data collected, a new empirical correlation equation has been proposed with a maximum error band of 10%. Flow pattern maps for the tested tubes have also been generated and are presented in the paper. Both of the two enhanced tubes were found to promote the development of annular flow. The HTCs were found to be highest when the flow pattern was of the annular flow type.
- 3 November 2023
- Published by ASME International in Journal of Solar Energy Engineering
- Vol. 146 (3) , 1-27
Condensation Heat Transfer Experiments of R410A and R32 in Horizontal Smooth and Enhanced Tubes
A horizontal smooth copper tube and two enhanced tubes (a dimpled tube and a diamond-shaped tube) with a length of 2 m and an outer diameter of 9.52 mm were studied in a two-phase condensation experiment using R410A and R32 as heat transfer working fluids. The condensation heat transfer performance of different heat transfer tubes at various mass fluxes ranging from 150 to 400 kg/(m2s) and different vapor qualities ranging from 0.8 to 0.2 was studied experimentally. For R410A, the heat transfer coefficients (HTCs) of the dimpled tube and the diamond-shaped tube were found to be 1.39-1.52 times and 1.30-1.35 times higher than those of the smooth tube, respectively. For R32, the HTCs were found to be 1.46-1.59 times higher for the dimpled tube and 1.26-1.35 times higher for the diamond-shaped tube than for the smooth tube. The diamond-shaped tube was found to be effective in directing the flow of the liquid phase and in thinning the liquid film thickness. The dimpled tube was found to promote droplet entrainment and disturbance. Both of those effects contributed to improving the HTCs in the two enhanced tubes investigated. The HTCs of R410A were found to be lower than those of R32 because of the smaller specific heat capacity, smaller latent heat of condensation, and relatively poorer thermal conductivity of R410A. Taking the combined effect of heat transfer and pressure drop into account, a performance enhancement factor (PEF) was computed and was found to range from 0.9 to 1.51. Based on the experimental data collected, a new empirical correlation equation has been proposed with a maximum error band of 10%. Flow pattern maps for the tested tubes have also been generated and are presented in the paper. Both of the two enhanced tubes were found to promote the development of annular flow. The HTCs were found to be highest when the flow pattern was of the annular flow type.
- 13 January 2022
- Published by ASME International in Journal of Solar Energy Engineering
- Vol. 144 (2) , 1-13
Nonequilibrium Thermal Fluctuations of Flow in Thermal Systems
Fouling is detrimental to the heat transfer performance of concentrated solar power plant components where heat exchange takes place with the cooling tower water. Wave elements cause an expression of deep insight of the fouling formation. A new physical concept of wave element is proposed; it is the wave interface between two molecule groups with an infinitesimal temperature difference in fluid. It is generated by density difference, which results from temperature difference. Tiny temperature differences always exist everywhere in a fluid. When a fluid is in motion, wave elements are generated among molecule groups. Wave motion and Brownian motion can serve as the two basic forms of motion of the molecules in flow. Temperature controls Brownian motion. Temperature differences and the fluid's motion cause the wave elements. Nonequilibrium thermal fluctuations present as wave elements in a flow. A wave element appears as wave behavior along the space and time dimensions that are based on the continuity relation. The direct experimental evidence for wave elements cannot be directly established at the present scientific testing cap ability because the temperature difference of two molecule groups adjoining each other in a flow is infinitesimal. A series of “enlarged size” experiments are conducted involving the cooling tower water fouling to show the wave elements’ behaviors by tracing the molecules’ movement. The experimental study presents that the wave interface along the space and time dimensions simultaneously exists between two densities due to fluid motion. The experimental evidence and theoretical analysis support each other.
- 13 January 2022
- Published by ASME International in Journal of Solar Energy Engineering
- Vol. 144 (2) , 1-13
Nonequilibrium Thermal Fluctuations of Flow in Thermal Systems
Fouling is detrimental to the heat transfer performance of concentrated solar power plant components where heat exchange takes place with the cooling tower water. Wave elements cause an expression of deep insight of the fouling formation. A new physical concept of wave element is proposed; it is the wave interface between two molecule groups with an infinitesimal temperature difference in fluid. It is generated by density difference, which results from temperature difference. Tiny temperature differences always exist everywhere in a fluid. When a fluid is in motion, wave elements are generated among molecule groups. Wave motion and Brownian motion can serve as the two basic forms of motion of the molecules in flow. Temperature controls Brownian motion. Temperature differences and the fluid's motion cause the wave elements. Nonequilibrium thermal fluctuations present as wave elements in a flow. A wave element appears as wave behavior along the space and time dimensions that are based on the continuity relation. The direct experimental evidence for wave elements cannot be directly established at the present scientific testing cap ability because the temperature difference of two molecule groups adjoining each other in a flow is infinitesimal. A series of “enlarged size” experiments are conducted involving the cooling tower water fouling to show the wave elements’ behaviors by tracing the molecules’ movement. The experimental study presents that the wave interface along the space and time dimensions simultaneously exists between two densities due to fluid motion. The experimental evidence and theoretical analysis support each other.
- 23 November 2021
- Published by ASME International in Journal of Solar Energy Engineering
- Vol. 144 (2) , 1-27
Experimental Study on CaCO3 Fouling Characteristics During Falling Film Evaporation
Falling film evaporation is widely used in solar desalination systems. Fouling is an important problem to be addressed in many applications involving heat transfer including processes involving the utilization of solar energy in desalination applications. In the research upon which this paper partly reports, an experimental investigation was carried out on a vertical tube in falling film evaporation to determine the effects of temperature, velocity, the use of a porous-sintered tube, and the use of Teflon coating on calcium carbonate deposition characteristics. During the fouling experiments, the pressure inside the test tubes was maintained constant at 101.3kPa, and the inlet temperature was maintained at 373K, while allowing the water mass velocity to vary from 0.42-1.05kg m−1s−1. Results show that the fouling in the test tube becomes more serious as the temperature increases and the flow rate decreases. Compared with stainless steel tubes, porous-sintered tubes can significantly reduce fouling resistance, but at the same time they bring about a decrease in the heat transfer coefficient. The Teflon coating also has anti-fouling performance, but does not affect the heat transfer coefficient in stainless steel tubes. Through the weighing of local fouling deposits, it has been found that the mass of the fouling deposits in the lower part of the tested tubes is greater than that in the upper part.
- 23 November 2021
- Published by ASME International in Journal of Solar Energy Engineering
- Vol. 144 (2) , 1-27
Experimental Study on CaCO3 Fouling Characteristics During Falling Film Evaporation
Falling film evaporation is widely used in solar desalination systems. Fouling is an important problem to be addressed in many applications involving heat transfer including processes involving the utilization of solar energy in desalination applications. In the research upon which this paper partly reports, an experimental investigation was carried out on a vertical tube in falling film evaporation to determine the effects of temperature, velocity, the use of a porous-sintered tube, and the use of Teflon coating on calcium carbonate deposition characteristics. During the fouling experiments, the pressure inside the test tubes was maintained constant at 101.3kPa, and the inlet temperature was maintained at 373K, while allowing the water mass velocity to vary from 0.42-1.05kg m−1s−1. Results show that the fouling in the test tube becomes more serious as the temperature increases and the flow rate decreases. Compared with stainless steel tubes, porous-sintered tubes can significantly reduce fouling resistance, but at the same time they bring about a decrease in the heat transfer coefficient. The Teflon coating also has anti-fouling performance, but does not affect the heat transfer coefficient in stainless steel tubes. Through the weighing of local fouling deposits, it has been found that the mass of the fouling deposits in the lower part of the tested tubes is greater than that in the upper part.
- 27 July 2021
- Published by Wiley in Journal of Thermal Science and Engineering Applications
- Vol. 14 (3) , 1-20
Shell-Side Flow Condensation Heat Transfer on Three-Dimensional Enhanced Surface
An experimental investigation of shell-side flow condensation was performed on three-dimensional surface enhanced tubes, including a herringbone micro-fin tube and a newly developed 1-EHT tube. An equivalent plain tube was also tested for performance comparison. All the test tubes had similar geometry parameters, i.e., inner diameter 11.43 mm and outer diameter 12.7 mm. The outer shell diameter was 24.5 mm with a wall thickness of 0.6 mm. Tests were conducted using R410A as the working fluid at a dew point of 45 °C. The mass flux range of 10–55 kg/(m2 · s) with an inlet quality of 0.8 and an outlet quality of 0.1. Experimental results showed that the plain tube exhibited a better condensation heat transfer performance. Moreover, the mass flux had a significant influence on the heat transfer coefficient for shell-side condensation. A new prediction model based on the Cavallini’s equation was developed to predict the condensing coefficient where the mean absolute error is less than 4%.
- 27 July 2021
- Published by Wiley in Journal of Thermal Science and Engineering Applications
- Vol. 14 (3) , 1-20
Shell-Side Flow Condensation Heat Transfer on Three-Dimensional Enhanced Surface
An experimental investigation of shell-side flow condensation was performed on three-dimensional surface enhanced tubes, including a herringbone micro-fin tube and a newly developed 1-EHT tube. An equivalent plain tube was also tested for performance comparison. All the test tubes had similar geometry parameters, i.e., inner diameter 11.43 mm and outer diameter 12.7 mm. The outer shell diameter was 24.5 mm with a wall thickness of 0.6 mm. Tests were conducted using R410A as the working fluid at a dew point of 45 °C. The mass flux range of 10–55 kg/(m2 · s) with an inlet quality of 0.8 and an outlet quality of 0.1. Experimental results showed that the plain tube exhibited a better condensation heat transfer performance. Moreover, the mass flux had a significant influence on the heat transfer coefficient for shell-side condensation. A new prediction model based on the Cavallini’s equation was developed to predict the condensing coefficient where the mean absolute error is less than 4%.