Mohamad Dakroub
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Mohamad Dakroub has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Nils A. Loewen
Department of Ophthalmology, University of Würzburg, Würzburg, Germany
9 shared publications - Raoul Verma-Fuehring
University Hospital Würzburg Josef-Schneider-Str. 11
8 shared publications Jost Hillenkamp
1-5Department of Ophthalmology, University Eye Hospital of Wuerzburg, Wuerzburg, Germany
6 shared publications- Alicja Strzalkowska
Augenklinik und Poliklinik, Universitätsmedizin der Johannes Gutenberg-Universität Mainz, Mainz, Deutschland
3 shared publications Hong Han
Department of Ophthalmology, University Hospital Wuerzburg, Wuerzburg, Bavaria, 97080, Germany
3 shared publications- Ahmed Bamousa2 shared publications
Latest Publications
- Open Access
- 13 May 2023
- Published by Jaypee Brothers Medical Publishing in Journal of Current Glaucoma Practice
- Vol. 17 (1) , 9-14
Coarsened Exact Matching of Excisional to Plasma-ablative Ab Interno Trabeculectomy
To compare ab interno trabeculectomy by trabecular meshwork (TM) excision to plasma-mediated ablation in primary open-angle glaucoma (POAG) patients. Retrospectively collected data of TrabEx+ (TEx) (n = 56) and Trabectome (T) (n = 99) patients were compared by coarsened exact matching to reduce confounding and matched based on baseline intraocular pressure (IOP) and age. The primary outcomes were IOP and the number of glaucoma medications. Complications and the need for additional glaucoma surgery were assessed. Patients were followed for up to 1 year. A total of 53 TEx could be matched to T. Baseline IOP was 16.5 ± 4.6 mm Hg in both; age was 73.7 ± 8.8 and 71.5 ± 9.9 years in TEx and T, respectively. TEx was taking more medications than T (p < 0.001). IOP was reduced to 14.8 ± 4.3 in TEx and to 13.4 ± 3.4 in T at 6 months, and to 14.9 ± 6.0 (p = 0.13) in TEx and to 14.1 ± 3.8 mm Hg (all p < 0.05) in T at 12 months. Medications were reduced at both 6 and 12 months (p < 0.05). No differences were seen between TEx and T at 6 and 12 months. In TEx, only one serious complication occurred, and two patients required further glaucoma surgery. Although both groups had a baseline IOP considered low for ab interno trabeculectomy, IOP and medications were reduced further at 6 and 12 months. IOP reduction did not reach significance in TEx at 12 months. The intergroup comparison did not reveal any significant differences. Both had a low complication rate. This study investigated subtle differences between a plasma-ablative device, the T, and an excisional device, the TEx, by applying coarsened exact matching. IOP and medications were reduced in both groups at 6 and 12 months, although IOP reduction did not reach significance in TEx at 12 months. The intergroup comparison did not reveal any significant differences, with both devices having a low complication rate. Dakroub M, Verma-Fuehring R, Strzalkowska A, et al. Coarsened Exact Matching of Excisional to Plasma-ablative Ab Interno Trabeculectomy. J Curr Glaucoma Pract 2023;17(1):9-14.
- 13 May 2023
- Published by Jaypee Brothers Medical Publishing in Journal of Current Glaucoma Practice
- Vol. 17 (1) , 9-14
Open AccessCoarsened Exact Matching of Excisional to Plasma-ablative Ab Interno Trabeculectomy
To compare ab interno trabeculectomy by trabecular meshwork (TM) excision to plasma-mediated ablation in primary open-angle glaucoma (POAG) patients. Retrospectively collected data of TrabEx+ (TEx) (n = 56) and Trabectome (T) (n = 99) patients were compared by coarsened exact matching to reduce confounding and matched based on baseline intraocular pressure (IOP) and age. The primary outcomes were IOP and the number of glaucoma medications. Complications and the need for additional glaucoma surgery were assessed. Patients were followed for up to 1 year. A total of 53 TEx could be matched to T. Baseline IOP was 16.5 ± 4.6 mm Hg in both; age was 73.7 ± 8.8 and 71.5 ± 9.9 years in TEx and T, respectively. TEx was taking more medications than T (p < 0.001). IOP was reduced to 14.8 ± 4.3 in TEx and to 13.4 ± 3.4 in T at 6 months, and to 14.9 ± 6.0 (p = 0.13) in TEx and to 14.1 ± 3.8 mm Hg (all p < 0.05) in T at 12 months. Medications were reduced at both 6 and 12 months (p < 0.05). No differences were seen between TEx and T at 6 and 12 months. In TEx, only one serious complication occurred, and two patients required further glaucoma surgery. Although both groups had a baseline IOP considered low for ab interno trabeculectomy, IOP and medications were reduced further at 6 and 12 months. IOP reduction did not reach significance in TEx at 12 months. The intergroup comparison did not reveal any significant differences. Both had a low complication rate. This study investigated subtle differences between a plasma-ablative device, the T, and an excisional device, the TEx, by applying coarsened exact matching. IOP and medications were reduced in both groups at 6 and 12 months, although IOP reduction did not reach significance in TEx at 12 months. The intergroup comparison did not reveal any significant differences, with both devices having a low complication rate. Dakroub M, Verma-Fuehring R, Strzalkowska A, et al. Coarsened Exact Matching of Excisional to Plasma-ablative Ab Interno Trabeculectomy. J Curr Glaucoma Pract 2023;17(1):9-14.
- Open Access
- 2 August 2022
- Published by MDPI AG in Preprints.org
Difference in Nycthemeral IOP Variation and Outflow Facility after Filtering Microshunt versus Canal-Based Ab Interno Glaucoma Surgery
Purpose: We hypothesized that a recently introduced epibulbar micro-shunt (PRESERFLO, P) produces nycthemeral (24h) intraocular pressure (IOP) profiles different from ab-interno trabeculectomy (Trabectome, T). P is a flow restrictor that drains fluid into the sub-tenon space. In contrast, T increases conventional outflow, which is limited by episcleral venous pressure. Methods: In this prospective cohort, we analyzed 68 patients (34 P and 34 T) who presented for 24-h IOP monitoring 6 to 12 months after surgery. IOP and tonographic outflow facility were measured in the habitual position using a pneumatonometer. The IOP variation was considered the primary outcome measure. Glaucoma medications were also compared. Results: P had a higher baseline IOP than T (24.8±10.0 vs. 17.3±7.9 mmHg, p=0.001). Postoperatively, P and T had similar nycthemeral IOP profiles, but IOP in P was significantly lower than in T, except at 4 pm. P had a lower absolute IOP variation than T (5.8±2.6 vs. 7.1±2.7 mmHg, p=0.049). The relative IOP variation was similar in both (34.8±13.2 vs. 37.2±13.1, p=0.45) as was the tonographic outflow facility (0.35±0.23 vs. 0.26±0.18 µl/min/mmHg, p=0.097). Conclusion: Nycthemeral IOP profiles of P and T were similar, but P had lower IOPs and less variation than T. This could reflect how T, unlike P, is more impacted by habitual, positional factors, especially at night.
- 2 August 2022
- Published by MDPI AG in Preprints.org
Open AccessDifference in Nycthemeral IOP Variation and Outflow Facility after Filtering Microshunt versus Canal-Based Ab Interno Glaucoma Surgery
Purpose: We hypothesized that a recently introduced epibulbar micro-shunt (PRESERFLO, P) produces nycthemeral (24h) intraocular pressure (IOP) profiles different from ab-interno trabeculectomy (Trabectome, T). P is a flow restrictor that drains fluid into the sub-tenon space. In contrast, T increases conventional outflow, which is limited by episcleral venous pressure. Methods: In this prospective cohort, we analyzed 68 patients (34 P and 34 T) who presented for 24-h IOP monitoring 6 to 12 months after surgery. IOP and tonographic outflow facility were measured in the habitual position using a pneumatonometer. The IOP variation was considered the primary outcome measure. Glaucoma medications were also compared. Results: P had a higher baseline IOP than T (24.8±10.0 vs. 17.3±7.9 mmHg, p=0.001). Postoperatively, P and T had similar nycthemeral IOP profiles, but IOP in P was significantly lower than in T, except at 4 pm. P had a lower absolute IOP variation than T (5.8±2.6 vs. 7.1±2.7 mmHg, p=0.049). The relative IOP variation was similar in both (34.8±13.2 vs. 37.2±13.1, p=0.45) as was the tonographic outflow facility (0.35±0.23 vs. 0.26±0.18 µl/min/mmHg, p=0.097). Conclusion: Nycthemeral IOP profiles of P and T were similar, but P had lower IOPs and less variation than T. This could reflect how T, unlike P, is more impacted by habitual, positional factors, especially at night.
- Open Access
- 26 April 2022
- Published by MDPI AG in Preprints.org
Comparison of PRESERFLO Implantation Techniques using a New Small Posterior Incision versus a Standard Anterior Peritomy
Purpose: To compare the standard implantation technique of a new ab externo microshunt (PRESERFLO) to a posterior technique with a small incision. The standard anterior approach (A) requires a relatively large, 6-8 mm perilimbal peritomy. In contrast, the posterior approach (P) involves only a 2-3 mm snip incision 2 mm posterior to the limbus. Methods: Charts of 126 PRESERFLO patients (54 A and 72 P) were retrospectively analyzed. Follow-up was 270 days. We compared the surgical time, intraocular pressure (IOP), number of medications, and complications. Results: The preoperative IOP in A was 21.8±8.5 mmHg and 23.9±8.1 mmHg in P (p=0.08). The surgical time for A was 26±0.8 minutes and 10±0.4 minutes for B (p 0.08). There were no inter-group differences in IOP at any visit (all p-values > 0.3). Patients in A and P took 3.2 ± 1.3 and 3.3 ± 1.0 pressure-lowering medications at baseline, respectively (p=0.4). These values declined to 0.2 ± 0.6 in A and 0.3 ± 0.7 in P at 270 days. Both groups had a similar number of revisions (13 (10.3%) versus 10 (7.9%, p=0.14)) and complications (26 (20.8%) versus 31 (24.6%, all p>0.25). Conclusion: The posterior PRESERFLO insertion technique was 2.6 times faster than the standard anterior technique and yielded similar results with a large reduction in IOP and medications and a safety profile favorable over traditional filtering surgery.
- 26 April 2022
- Published by MDPI AG in Preprints.org
Open AccessComparison of PRESERFLO Implantation Techniques using a New Small Posterior Incision versus a Standard Anterior Peritomy
Purpose: To compare the standard implantation technique of a new ab externo microshunt (PRESERFLO) to a posterior technique with a small incision. The standard anterior approach (A) requires a relatively large, 6-8 mm perilimbal peritomy. In contrast, the posterior approach (P) involves only a 2-3 mm snip incision 2 mm posterior to the limbus. Methods: Charts of 126 PRESERFLO patients (54 A and 72 P) were retrospectively analyzed. Follow-up was 270 days. We compared the surgical time, intraocular pressure (IOP), number of medications, and complications. Results: The preoperative IOP in A was 21.8±8.5 mmHg and 23.9±8.1 mmHg in P (p=0.08). The surgical time for A was 26±0.8 minutes and 10±0.4 minutes for B (p 0.08). There were no inter-group differences in IOP at any visit (all p-values > 0.3). Patients in A and P took 3.2 ± 1.3 and 3.3 ± 1.0 pressure-lowering medications at baseline, respectively (p=0.4). These values declined to 0.2 ± 0.6 in A and 0.3 ± 0.7 in P at 270 days. Both groups had a similar number of revisions (13 (10.3%) versus 10 (7.9%, p=0.14)) and complications (26 (20.8%) versus 31 (24.6%, all p>0.25). Conclusion: The posterior PRESERFLO insertion technique was 2.6 times faster than the standard anterior technique and yielded similar results with a large reduction in IOP and medications and a safety profile favorable over traditional filtering surgery.
- Open Access
- 9 February 2022
- Published by F1000 Research Ltd in F1000Research
- Vol. 10, 525
Impact of freeze-thaw cytoablation on aqueous outflow patterns in ex vivo anterior chamber perfusion cultures and whole eyes
Background: Porcine eyes have been widely used as ex vivo models in glaucoma research, as they share similar features with human eyes. Freeze-thawing is a non-invasive technique that has been used to obliterate living cells in anterior segment ex vivo cultures, to prepare them for further research such as cellular repopulation. This technique has previously been shown to reduce the intraocular pressure (IOP) in porcine eyes. The aim of this study was to investigate whether freeze-thaw cytoablation causes corresponding canalogram outflow changes in perfused anterior segment cultures (AFT) and whole porcine eyes (WFT). We hypothesized that the known IOP drop in AFT after trabecular meshwork ablation by freeze-thaw would be accompanied by a similarly large change in the distal outflow pattern. Methods: Two-dye (fluorescein and Texas red) reperfusion canalograms were used to compare the outflow time before and after two -80°C cycles of freeze-thaw. We assigned 28 freshly enucleated porcine eyes to four groups: perfused anterior segment dye controls (ACO, n = 6), perfused whole eye dye controls (WCO, n = 6), freeze-thaw treated anterior segment cultures (AFT, n = 10), and freeze-thaw treated whole eyes (WFT, n = 6). Results: In control groups ACO and WCO, the two different dyes had similar filling times. In AFT, the outflow pattern and filling times were unchanged. In WFT, the temporal superior quadrant filled more slowly (p = 0.042) while all others remained unchanged. The qualitative appearance of distal outflow spaces was altered only in some eyes. Conclusions: Freeze-thaw cytoablation caused neither loss nor leakage of distal outflow structures. Surprisingly, the loss of an intact trabecular meshwork over the entire circumference did not result in a general acceleration of quadrant outflow times. The results validate freeze-thawing as a method to generate an extracellular matrix without major structural changes.
- 9 February 2022
- Published by F1000 Research Ltd in F1000Research
- Vol. 10, 525
Open AccessImpact of freeze-thaw cytoablation on aqueous outflow patterns in ex vivo anterior chamber perfusion cultures and whole eyes
Background: Porcine eyes have been widely used as ex vivo models in glaucoma research, as they share similar features with human eyes. Freeze-thawing is a non-invasive technique that has been used to obliterate living cells in anterior segment ex vivo cultures, to prepare them for further research such as cellular repopulation. This technique has previously been shown to reduce the intraocular pressure (IOP) in porcine eyes. The aim of this study was to investigate whether freeze-thaw cytoablation causes corresponding canalogram outflow changes in perfused anterior segment cultures (AFT) and whole porcine eyes (WFT). We hypothesized that the known IOP drop in AFT after trabecular meshwork ablation by freeze-thaw would be accompanied by a similarly large change in the distal outflow pattern. Methods: Two-dye (fluorescein and Texas red) reperfusion canalograms were used to compare the outflow time before and after two -80°C cycles of freeze-thaw. We assigned 28 freshly enucleated porcine eyes to four groups: perfused anterior segment dye controls (ACO, n = 6), perfused whole eye dye controls (WCO, n = 6), freeze-thaw treated anterior segment cultures (AFT, n = 10), and freeze-thaw treated whole eyes (WFT, n = 6). Results: In control groups ACO and WCO, the two different dyes had similar filling times. In AFT, the outflow pattern and filling times were unchanged. In WFT, the temporal superior quadrant filled more slowly (p = 0.042) while all others remained unchanged. The qualitative appearance of distal outflow spaces was altered only in some eyes. Conclusions: Freeze-thaw cytoablation caused neither loss nor leakage of distal outflow structures. Surprisingly, the loss of an intact trabecular meshwork over the entire circumference did not result in a general acceleration of quadrant outflow times. The results validate freeze-thawing as a method to generate an extracellular matrix without major structural changes.
- Open Access
- 20 September 2021
- Published by MDPI AG in Preprints.org
A Predictive Test of Outflow Enhancement by Ab Interno Trabeculectomy
Purpose: To investigate trabeculopuncture (TP) for predicting the outcome of ab interno trabeculectomy (AIT). AIT is an effective, low-risk procedure for open angle glaucoma. Despite widespread utilization, it fails in patients with an unidentified distal outflow resistance. Methods: We bisected 81 enucleated porcine eyes and perfused them for 72 hours. They were assigned to two groups: trial (n=42) and control (n=39). Intraocular pressure (IOP) was measured continuously. At 24 hours, four YAG-laser trabeculopunctures on the nasal trabecular meshwork were performed, followed by a 180° AIT at the same site at 48 hours. Eyes were divided into TP and AIT responders and non-responders; the proportion of TP responders between both AIT groups was compared. Results: Both post-TP and post-AIT IOPs were lower than baseline IOP (p=0.015 and p<0.01, respectively). The success rates of TP and AIT were 69% and 85.7%, respectively. The proportion of TP responders among AIT responders was greater than that of AIT non-responders (p20% IOP decrease) of 180° AIT in porcine eyes.
- 20 September 2021
- Published by MDPI AG in Preprints.org
Open AccessA Predictive Test of Outflow Enhancement by Ab Interno Trabeculectomy
Purpose: To investigate trabeculopuncture (TP) for predicting the outcome of ab interno trabeculectomy (AIT). AIT is an effective, low-risk procedure for open angle glaucoma. Despite widespread utilization, it fails in patients with an unidentified distal outflow resistance. Methods: We bisected 81 enucleated porcine eyes and perfused them for 72 hours. They were assigned to two groups: trial (n=42) and control (n=39). Intraocular pressure (IOP) was measured continuously. At 24 hours, four YAG-laser trabeculopunctures on the nasal trabecular meshwork were performed, followed by a 180° AIT at the same site at 48 hours. Eyes were divided into TP and AIT responders and non-responders; the proportion of TP responders between both AIT groups was compared. Results: Both post-TP and post-AIT IOPs were lower than baseline IOP (p=0.015 and p<0.01, respectively). The success rates of TP and AIT were 69% and 85.7%, respectively. The proportion of TP responders among AIT responders was greater than that of AIT non-responders (p20% IOP decrease) of 180° AIT in porcine eyes.
- Open Access
- 14 September 2021
- Published by MDPI AG in Preprints.org
Coarsened Exact Matching of Excisional to Plasma-Ablative Ab Interno Trabeculectomy
Purpose: To compare ab interno trabeculectomy by trabecular meshwork excision to plasma-mediated ablation in primary open-angle glaucoma. Methods: Retrospectively collected data of TrabEx+ (TEx, n=56) and Trabectome (T, n=99) were compared by coarsened exact matching to reduce confounding and matched based on baseline IOP and age. Primary outcomes were IOP and number of glaucoma medications. Complications and need for additional glaucoma surgery were assessed. Patients were followed for up to one year. Results: 53 TEx could be matched to T. Baseline IOP was 16.5±4.6 mmHg in both; age was 73.7±8.8 and 71.5±9.9 years in TEx and T, respectively. TEx were taking more medications than T (p<0.001). IOP was reduced to 14.8±4.3 in TEx and to 13.4±3.4 in T at 6 months, and to 14.9±6.0 (p=0.13) in TEx and to 14.1±3.8 mmHg (all p<0.05) in T at 12 months. Medications were reduced at both 6 and 12 months (p< 0.05). No differences were seen between TEx and T at 6 and 12 months. In TEx, only one serious complication occurred, and two patients required further glaucoma surgery. Conclusion: Although both groups had a baseline IOP considered low for ab-interno trabeculectomy, IOP and medications were reduced further at 6 and 12 months. IOP reduction did not reach significance in TEx at 12 months. The inter-group comparison did not reveal any significant differences. Both had a low complication rate.
- 14 September 2021
- Published by MDPI AG in Preprints.org
Open AccessCoarsened Exact Matching of Excisional to Plasma-Ablative Ab Interno Trabeculectomy
Purpose: To compare ab interno trabeculectomy by trabecular meshwork excision to plasma-mediated ablation in primary open-angle glaucoma. Methods: Retrospectively collected data of TrabEx+ (TEx, n=56) and Trabectome (T, n=99) were compared by coarsened exact matching to reduce confounding and matched based on baseline IOP and age. Primary outcomes were IOP and number of glaucoma medications. Complications and need for additional glaucoma surgery were assessed. Patients were followed for up to one year. Results: 53 TEx could be matched to T. Baseline IOP was 16.5±4.6 mmHg in both; age was 73.7±8.8 and 71.5±9.9 years in TEx and T, respectively. TEx were taking more medications than T (p<0.001). IOP was reduced to 14.8±4.3 in TEx and to 13.4±3.4 in T at 6 months, and to 14.9±6.0 (p=0.13) in TEx and to 14.1±3.8 mmHg (all p<0.05) in T at 12 months. Medications were reduced at both 6 and 12 months (p< 0.05). No differences were seen between TEx and T at 6 and 12 months. In TEx, only one serious complication occurred, and two patients required further glaucoma surgery. Conclusion: Although both groups had a baseline IOP considered low for ab-interno trabeculectomy, IOP and medications were reduced further at 6 and 12 months. IOP reduction did not reach significance in TEx at 12 months. The inter-group comparison did not reveal any significant differences. Both had a low complication rate.
- Open Access
- 30 August 2021
- Published by MDPI AG in Preprints.org
Inter-Eye Correlation Analysis of 24-hour IOPs and Glaucoma Progression
Purpose: To determine whether 24-hour IOP monitoring can be a predictor for glaucoma progression and to analyze the inter-eye relationship of IOP, perfusion and progression parameters. Methods: We extracted data from manually drawn IOP curves with HIOP-Reader, a software suite we developed. The relationship between measured IOPs and mean ocular perfusion pressures (MOPP) to retinal nerve fiber layer (RNFL) thickness was analyzed. We determined the ROC curves for peak IOP (Tmax), average IOP (Tavg), IOP variation (IOPvar) and historical IOP cut-off levels to detect glaucoma progression (rate of RNFL loss). Bivariate analysis was conducted to check for various inter-eye relationships. Results: 217 eyes were included. The average IOP was 14.8±3.5 mmHg, with a 24-hour variation of 5.2±2.9 mmHg. 52% of eyes with RNFL data showed disease progression. There was no significant difference in Tmax, Tavg and IOPvar between progressors and non-progressors (all p>0.05). Except for Tavg and the temporal RNFL, there was no correlation between disease progression in any quadrant, Tmax, Tavg and IOPvar. 24-hour and outpatient IOP variables had poor sensitivities and specificities in detecting disease progression. The correlation of inter-eye parameters was moderate; correlation with disease progression was weak. Conclusion: In line with our previous study, IOP data obtained during a single visit (outpatient or inpatient monitoring) make for a poor diagnostic tool, no matter the method deployed. Glaucoma progression and perfusion pressure in left and right eyes correlated weakly to moderately with each other.
- 30 August 2021
- Published by MDPI AG in Preprints.org
Open AccessInter-Eye Correlation Analysis of 24-hour IOPs and Glaucoma Progression
Purpose: To determine whether 24-hour IOP monitoring can be a predictor for glaucoma progression and to analyze the inter-eye relationship of IOP, perfusion and progression parameters. Methods: We extracted data from manually drawn IOP curves with HIOP-Reader, a software suite we developed. The relationship between measured IOPs and mean ocular perfusion pressures (MOPP) to retinal nerve fiber layer (RNFL) thickness was analyzed. We determined the ROC curves for peak IOP (Tmax), average IOP (Tavg), IOP variation (IOPvar) and historical IOP cut-off levels to detect glaucoma progression (rate of RNFL loss). Bivariate analysis was conducted to check for various inter-eye relationships. Results: 217 eyes were included. The average IOP was 14.8±3.5 mmHg, with a 24-hour variation of 5.2±2.9 mmHg. 52% of eyes with RNFL data showed disease progression. There was no significant difference in Tmax, Tavg and IOPvar between progressors and non-progressors (all p>0.05). Except for Tavg and the temporal RNFL, there was no correlation between disease progression in any quadrant, Tmax, Tavg and IOPvar. 24-hour and outpatient IOP variables had poor sensitivities and specificities in detecting disease progression. The correlation of inter-eye parameters was moderate; correlation with disease progression was weak. Conclusion: In line with our previous study, IOP data obtained during a single visit (outpatient or inpatient monitoring) make for a poor diagnostic tool, no matter the method deployed. Glaucoma progression and perfusion pressure in left and right eyes correlated weakly to moderately with each other.
- Open Access
- 1 July 2021
- Published by MDPI AG in Preprints.org
HIOP-Reader: Automated Data Extraction for the Analysis of Manually Recorded Nycthemeral IOPs and Glaucoma Progression
Purpose: Nycthemeral (24-hour) glaucoma inpatient intraocular pressure (IOP) monitoring has been used in Europe for more than 100 years to detect peaks missed during regular office hours. Data supporting this practice is lacking, partially because it is difficult to correlate manually drawn IOP curves to objective glaucoma progression. To address this, we deployed automated IOP data extraction tools and tested for a correlation to a progressive retinal nerve fiber layer loss on spectral-domain optical coherence tomography (SDOCT). Methods: We created and deployed a machine-learning image analysis software to extract IOP data from hand-drawn, nycthemeral IOP curves of 225 retrospectively identified glaucoma patients. The relationship between demographic parameters, IOP and mean ocular perfusion pressure (MOPP) data to SDOCT data was analyzed. Sensitivities and specificities for the historical cut-off values of 15 mmHg and 22 mmHg in detecting glaucoma progression were calculated. Results: IOP data could be extracted efficiently. The IOP average was 15.2±4.0 mmHg, nycthemeral IOP variation was 6.9±4.2 mmHg, and MOPP was 59.1±8.9 mmHg. Peak IOP occurred at 10 AM and trough at 9 PM. Disease progression occurred mainly in the temporal-superior and -inferior SDOCT sectors. No correlation could be established between demographic, IOP, or MOPP parameters and SDOCT disease progression. The sensitivity and specificity of both cut-off points (15 and 22 mmHg) were insufficient to be clinically useful. Outpatient IOPs were non-inferior to nycthemeral IOPs. Conclusion: IOP data obtained during a single visit make for a poor diagnostic tool, no matter whether obtained using nycthemeral measurements or during outpatient hours.
- 1 July 2021
- Published by MDPI AG in Preprints.org
Open AccessHIOP-Reader: Automated Data Extraction for the Analysis of Manually Recorded Nycthemeral IOPs and Glaucoma Progression
Purpose: Nycthemeral (24-hour) glaucoma inpatient intraocular pressure (IOP) monitoring has been used in Europe for more than 100 years to detect peaks missed during regular office hours. Data supporting this practice is lacking, partially because it is difficult to correlate manually drawn IOP curves to objective glaucoma progression. To address this, we deployed automated IOP data extraction tools and tested for a correlation to a progressive retinal nerve fiber layer loss on spectral-domain optical coherence tomography (SDOCT). Methods: We created and deployed a machine-learning image analysis software to extract IOP data from hand-drawn, nycthemeral IOP curves of 225 retrospectively identified glaucoma patients. The relationship between demographic parameters, IOP and mean ocular perfusion pressure (MOPP) data to SDOCT data was analyzed. Sensitivities and specificities for the historical cut-off values of 15 mmHg and 22 mmHg in detecting glaucoma progression were calculated. Results: IOP data could be extracted efficiently. The IOP average was 15.2±4.0 mmHg, nycthemeral IOP variation was 6.9±4.2 mmHg, and MOPP was 59.1±8.9 mmHg. Peak IOP occurred at 10 AM and trough at 9 PM. Disease progression occurred mainly in the temporal-superior and -inferior SDOCT sectors. No correlation could be established between demographic, IOP, or MOPP parameters and SDOCT disease progression. The sensitivity and specificity of both cut-off points (15 and 22 mmHg) were insufficient to be clinically useful. Outpatient IOPs were non-inferior to nycthemeral IOPs. Conclusion: IOP data obtained during a single visit make for a poor diagnostic tool, no matter whether obtained using nycthemeral measurements or during outpatient hours.
- Open Access
- 1 July 2021
- Published by F1000 Research Ltd in F1000Research
- Vol. 10, 525
Impact of freeze-thaw cytoablation on aqueous outflow patterns in ex vivo anterior chamber perfusion cultures and whole eyes
Background: Porcine eyes have been widely used as ex vivo models in glaucoma research, as they share similar features with human eyes. Freeze-thawing is a non-invasive technique that has been used to obliterate living cells in anterior segment ex vivo cultures, to prepare them for further research such as cellular repopulation. This technique has previously been shown to reduce the intraocular pressure (IOP) in porcine eyes. The aim of this study was to investigate whether freeze-thaw cytoablation causes corresponding canalogram outflow changes in perfused anterior segment cultures (AFT) and whole porcine eyes (WFT). We hypothesized that the known IOP drop in AFT after trabecular meshwork ablation by freeze-thaw would be accompanied by a similarly large change in the distal outflow pattern. Methods: Two-dye (fluorescein and Texas red) reperfusion canalograms were used to compare the outflow time before and after two -80°C cycles of freeze-thaw. We assigned 28 freshly enucleated porcine eyes to four groups: perfused anterior segment dye controls (ACO, n = 6), perfused whole eye dye controls (WCO, n = 6), freeze-thaw treated anterior segment cultures (AFT, n = 10), and freeze-thaw treated whole eyes (WFT, n = 6). Results: In control groups ACO and WCO, the two different dyes had similar filling times. In AFT, the outflow pattern and filling times were unchanged. In WFT, the temporal superior quadrant filled more slowly (p = 0.042) while all others remained unchanged. The qualitative appearance of distal outflow spaces was altered only in some eyes. Conclusions: Freeze-thaw cytoablation caused neither loss nor leakage of distal outflow structures. Surprisingly, the loss of an intact trabecular meshwork over the entire circumference did not result in a general acceleration of quadrant outflow times. The results validate freeze-thawing as a method to generate an extracellular matrix without major structural changes.
- 1 July 2021
- Published by F1000 Research Ltd in F1000Research
- Vol. 10, 525
Open AccessImpact of freeze-thaw cytoablation on aqueous outflow patterns in ex vivo anterior chamber perfusion cultures and whole eyes
Background: Porcine eyes have been widely used as ex vivo models in glaucoma research, as they share similar features with human eyes. Freeze-thawing is a non-invasive technique that has been used to obliterate living cells in anterior segment ex vivo cultures, to prepare them for further research such as cellular repopulation. This technique has previously been shown to reduce the intraocular pressure (IOP) in porcine eyes. The aim of this study was to investigate whether freeze-thaw cytoablation causes corresponding canalogram outflow changes in perfused anterior segment cultures (AFT) and whole porcine eyes (WFT). We hypothesized that the known IOP drop in AFT after trabecular meshwork ablation by freeze-thaw would be accompanied by a similarly large change in the distal outflow pattern. Methods: Two-dye (fluorescein and Texas red) reperfusion canalograms were used to compare the outflow time before and after two -80°C cycles of freeze-thaw. We assigned 28 freshly enucleated porcine eyes to four groups: perfused anterior segment dye controls (ACO, n = 6), perfused whole eye dye controls (WCO, n = 6), freeze-thaw treated anterior segment cultures (AFT, n = 10), and freeze-thaw treated whole eyes (WFT, n = 6). Results: In control groups ACO and WCO, the two different dyes had similar filling times. In AFT, the outflow pattern and filling times were unchanged. In WFT, the temporal superior quadrant filled more slowly (p = 0.042) while all others remained unchanged. The qualitative appearance of distal outflow spaces was altered only in some eyes. Conclusions: Freeze-thaw cytoablation caused neither loss nor leakage of distal outflow structures. Surprisingly, the loss of an intact trabecular meshwork over the entire circumference did not result in a general acceleration of quadrant outflow times. The results validate freeze-thawing as a method to generate an extracellular matrix without major structural changes.