Lekhramsingh Latchoomun
Lekhramsingh Latchoomun has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
D. Mawooa
Electromechanical Automation Engineering Dept., Faculty of Sustainable Development Engineering, Universit des Mascareignes, Roche-Brunes, Mauritius
3 shared publicationsK. Busawon
University of Northumbria
3 shared publications- Krishna Busawon
Department of Mechanical Engineering University of Northumbria Newcastle UK
2 shared publications R.T.F. Ah King
2 shared publications- Robert Tat Fung Ah King
University of Mauritius
2 shared publications A. Dhunnoo
1 shared publication
Latest Publications
- 16 April 2021
- Published by Springer Nature
- p. 763-776
Fault Detection and Isolation in a Leaky Water Distribution Network Using Fuzzy Logic Control Based on Residual Pressure Analysis
- 16 April 2021
- Published by Springer Nature
- p. 763-776
Fault Detection and Isolation in a Leaky Water Distribution Network Using Fuzzy Logic Control Based on Residual Pressure Analysis
- 9 May 2019
- Published by Springer Nature
- p. 45-59
Efficiency of VFD Coupled Induction Motors Operating in the Scalar Mode with Different Types of Loads
- 9 May 2019
- Published by Springer Nature
- p. 45-59
Efficiency of VFD Coupled Induction Motors Operating in the Scalar Mode with Different Types of Loads
- 1 September 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
An Overview of Wave Energy Technologies in the Mauritian Context
Small Island developing states like Mauritius are very vulnerable to climate change as well as to fluctuating fossil fuels prices in the international market. Mauritius is targeting 35% mixed renewable energy generation by 2025. This work will focus on different types of wave energy converter (WEC) that can be used to supplement the existing local electrical energy grid. The key dimensions of a WEC are analyzed with respect to their ocean environment, namely, shore, nearshore and offshore and coupled to their working principles. Furthermore, the pros and cons of such devices are considered and much efforts have also been made to summarize the current status and future potentials of wave as an alternative renewable energy option for Mauritius.
- 1 September 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
An Overview of Wave Energy Technologies in the Mauritian Context
Small Island developing states like Mauritius are very vulnerable to climate change as well as to fluctuating fossil fuels prices in the international market. Mauritius is targeting 35% mixed renewable energy generation by 2025. This work will focus on different types of wave energy converter (WEC) that can be used to supplement the existing local electrical energy grid. The key dimensions of a WEC are analyzed with respect to their ocean environment, namely, shore, nearshore and offshore and coupled to their working principles. Furthermore, the pros and cons of such devices are considered and much efforts have also been made to summarize the current status and future potentials of wave as an alternative renewable energy option for Mauritius.
- 21 January 2017
- Published by Springer Nature in Lecture Notes in Electrical Engineering
- p. 107-118
Quantifying the Pumping Energy Loss Associated with Different Types of Leak in a Piping System
- 21 January 2017
- Published by Springer Nature in Lecture Notes in Electrical Engineering
- p. 107-118
Quantifying the Pumping Energy Loss Associated with Different Types of Leak in a Piping System
- Open Access
- 1 January 2015
- Published by Elsevier in Procedia Engineering
- Vol. 119, 690-699
A new approach to model development of water distribution networks with high leakage and burst rates
- 1 January 2015
- Published by Elsevier in Procedia Engineering
- Vol. 119, 690-699
Open AccessA new approach to model development of water distribution networks with high leakage and burst rates
- Open Access
- 1 January 2015
- Published by Elsevier in Procedia Engineering
- Vol. 119, 91-100
Laboratory Investigation of the Leakage Characteristics of Unburied HDPE Pipes
- 1 January 2015
- Published by Elsevier in Procedia Engineering
- Vol. 119, 91-100
Open AccessLaboratory Investigation of the Leakage Characteristics of Unburied HDPE Pipes
- 1 June 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 207-211
A low cost automated scheme to avoid load shedding during simultaneous start-up of single and three-phase aplit air-conditioning units
There is a very large number of split air conditioners without inverter in operation in Mauritius and despite the various advantages that inverter-equipped air conditioners offer, traditional air conditioners are still being widely installed in the country because there is no legislation regarding the use of energy efficient equipment at present. In this paper, we design a low cost automated scheme to avoid load shedding during simultaneous start-up of single and three phase split air-conditioning units. The main idea is to give customers the flexibility of extending their plant's load without bothering too much about load-shedding when starting all their equipment at a time. The design strategy is based on a PLC which interfaces the indoor with the outdoor unit of every split air conditioner. Furthermore, the possibility of reducing the maximum kilovolt-ampere (KVA) demand with this strategy is also possible. Finally, the design is tested and implemented on a sample of three such single phase units based in Mauritius. Analysis of the results of this scheme clearly shows its superiority compared to the simultaneous start-up of three units normally in terms of the peak apparent power consumption.
- 1 June 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 207-211
A low cost automated scheme to avoid load shedding during simultaneous start-up of single and three-phase aplit air-conditioning units
There is a very large number of split air conditioners without inverter in operation in Mauritius and despite the various advantages that inverter-equipped air conditioners offer, traditional air conditioners are still being widely installed in the country because there is no legislation regarding the use of energy efficient equipment at present. In this paper, we design a low cost automated scheme to avoid load shedding during simultaneous start-up of single and three phase split air-conditioning units. The main idea is to give customers the flexibility of extending their plant's load without bothering too much about load-shedding when starting all their equipment at a time. The design strategy is based on a PLC which interfaces the indoor with the outdoor unit of every split air conditioner. Furthermore, the possibility of reducing the maximum kilovolt-ampere (KVA) demand with this strategy is also possible. Finally, the design is tested and implemented on a sample of three such single phase units based in Mauritius. Analysis of the results of this scheme clearly shows its superiority compared to the simultaneous start-up of three units normally in terms of the peak apparent power consumption.