Francesco Chessa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Francesco Chessa has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Amelio Ercolino
Division of Urology, IRCCS Azienda Ospedaliero-Universitaria di Bologna, Bologna, Italy
2 shared publications - Eugenio Brunocilla
Division of Urology, IRCCS Azienda Ospedaliero Universitaria di Bologna, 40138 Bologna, Italy
2 shared publications - Lorenzo Bianchi
Division of Urology, IRCCS Azienda Ospedaliero-Universitaria di Bologna, Bologna, Italy -
2 shared publications - Alessandro Bertaccini
Division of Urology, IRCCS Azienda Ospedaliero—Universitaria di Bologna, 40138 Bologna, Italy
1 shared publication - Angelo Mottaran
Division of Urology, IRCCS Azienda Ospedaliero-Universitaria di Bologna, Bologna, Italy
1 shared publication - Beniamino Corcioni
Department of Radiology, IRCCS Azienda Ospedaliero-Universitaria di Bologna, 40138 Bologna, Italy
1 shared publication
Latest Publications
- Open Access
Twenty Years’ Experience in Retroperitoneal Lymph Node Dissection for Testicular Cancer in a Tertiary Referral Center
Background and Objectives: The aim of this article is to present a single-surgeon, open retroperitoneal lymph node dissection (RPLND) series for testicular cancer in a high-volume center. Materials and Methods: We reviewed data from patients who underwent RPLND performed by an experienced surgeon at our institution between 2000 and 2019. We evaluated surgical and perioperative outcomes, complications, Recurrence-Free Survival (RFS), Overall Survival (OS), and Cancer-Specific Survival (CSS). Results: RPLND was performed in primary and secondary settings in 21 (32%) and 44 (68%) patients, respectively. Median operative time was 180 min. Median hospital stay was 6 days. Complications occurred in 23 (35%) patients, with 9 (14%) events reported as Clavien grade ≥ 3. Patients in the primary RPLND group were significantly younger, more likely to have NSGCT, had higher clinical N0 and M0, and had higher nerve-sparing RPLND (all p ≤ 0.04) compared to those in the secondary RPLND group. In the median follow-up of 120 (56–180) months, 10 (15%) patients experienced recurrence. Finally, 20-year OS, CSS, and RFS were 89%, 92%, and 85%, respectively, with no significant difference in survival rates between primary vs. secondary RPLND subgroups (p = 0.64, p = 0.7, and p = 0.31, respectively). Conclusions: Open RPLND performed by an experienced high-volume surgeon achieves excellent oncological and functional outcomes supporting the centralization of these complex procedures.
Open AccessTwenty Years’ Experience in Retroperitoneal Lymph Node Dissection for Testicular Cancer in a Tertiary Referral Center
Background and Objectives: The aim of this article is to present a single-surgeon, open retroperitoneal lymph node dissection (RPLND) series for testicular cancer in a high-volume center. Materials and Methods: We reviewed data from patients who underwent RPLND performed by an experienced surgeon at our institution between 2000 and 2019. We evaluated surgical and perioperative outcomes, complications, Recurrence-Free Survival (RFS), Overall Survival (OS), and Cancer-Specific Survival (CSS). Results: RPLND was performed in primary and secondary settings in 21 (32%) and 44 (68%) patients, respectively. Median operative time was 180 min. Median hospital stay was 6 days. Complications occurred in 23 (35%) patients, with 9 (14%) events reported as Clavien grade ≥ 3. Patients in the primary RPLND group were significantly younger, more likely to have NSGCT, had higher clinical N0 and M0, and had higher nerve-sparing RPLND (all p ≤ 0.04) compared to those in the secondary RPLND group. In the median follow-up of 120 (56–180) months, 10 (15%) patients experienced recurrence. Finally, 20-year OS, CSS, and RFS were 89%, 92%, and 85%, respectively, with no significant difference in survival rates between primary vs. secondary RPLND subgroups (p = 0.64, p = 0.7, and p = 0.31, respectively). Conclusions: Open RPLND performed by an experienced high-volume surgeon achieves excellent oncological and functional outcomes supporting the centralization of these complex procedures.
- Open Access
- 28 June 2021
- Published by PAGEPress Publications in Archivio Italiano di Urologia e Andrologia
- Vol. 93 (2) , 132-138
Diagnostic accuracy of the Novel 29 MHz micro-ultrasound “ExactVuTM” for the detection of clinically significant prostate cancer: A prospective single institutional study. A step forward in the diagnosis of prostate cancer
Introduction and Objective: ExactVuTM is a real-time micro-ultrasound system which provides, according to the Prostate Risk Identification Using Micro-Ultrasound protocol (PRI-MUS), a 300% higher resolution compared to conventional transrectal ultrasound. To evaluate the performance of ExactVuTM in the detection of Clinically significant Prostate Cancer (CsPCa). Materials and methods: Patients with Prostate Cancer diagnosed at fusion biopsy were imaged with ExactVuTM. CsPCa was defined as any Gleason Score ≥ 3+4. ExactVuTM examination was considered as positive when PRI-MUS score was ≥ 3. PRI-MUS scoring system was considered as correct when the fusion biopsy was positive for CsPCa. A transrectal fusion biopsy- proven CsPCa was considered as a gold standard. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and area under the receiver operator characteristic (ROC) curve (AUC) were calculated. Results: 57 patients out of 68 (84%) had a csPCa. PRI-MUS score was correctly assessed in 68% of cases. Regarding the detection of CsPCa, ExactVuTM ’s sensitivity, specificity, PPV, and NPV was 68%, 73%, 93%, and 31%, respectively and the AUC was 0.7 (95% CI 0.5-0-8). For detecting CsPCa in the transition/ anterior zone the sensitivity, specificity, PPV, and NPV was 45%, 66%, 83% and 25% respectively ant the AUC was 0.5 (95% CI 0.2-0.9). Accounting only the CsPCa located in the peripheral zone, sensitivity, specificity, PPV, and NPV raised up to 74%, 75%, 94%, 33%, respectively with AUC 0.75 (95% CI 0.5-0-9). Conclusions: ExactVuTM provides high resolution of the prostatic peripheral zone and could represent a step forward in the detection of CsPCa as a triage tool. Further studies are needed to confirm these promising results.
- 28 June 2021
- Published by PAGEPress Publications in Archivio Italiano di Urologia e Andrologia
- Vol. 93 (2) , 132-138
Open AccessDiagnostic accuracy of the Novel 29 MHz micro-ultrasound “ExactVuTM” for the detection of clinically significant prostate cancer: A prospective single institutional study. A step forward in the diagnosis of prostate cancer
Introduction and Objective: ExactVuTM is a real-time micro-ultrasound system which provides, according to the Prostate Risk Identification Using Micro-Ultrasound protocol (PRI-MUS), a 300% higher resolution compared to conventional transrectal ultrasound. To evaluate the performance of ExactVuTM in the detection of Clinically significant Prostate Cancer (CsPCa). Materials and methods: Patients with Prostate Cancer diagnosed at fusion biopsy were imaged with ExactVuTM. CsPCa was defined as any Gleason Score ≥ 3+4. ExactVuTM examination was considered as positive when PRI-MUS score was ≥ 3. PRI-MUS scoring system was considered as correct when the fusion biopsy was positive for CsPCa. A transrectal fusion biopsy- proven CsPCa was considered as a gold standard. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and area under the receiver operator characteristic (ROC) curve (AUC) were calculated. Results: 57 patients out of 68 (84%) had a csPCa. PRI-MUS score was correctly assessed in 68% of cases. Regarding the detection of CsPCa, ExactVuTM ’s sensitivity, specificity, PPV, and NPV was 68%, 73%, 93%, and 31%, respectively and the AUC was 0.7 (95% CI 0.5-0-8). For detecting CsPCa in the transition/ anterior zone the sensitivity, specificity, PPV, and NPV was 45%, 66%, 83% and 25% respectively ant the AUC was 0.5 (95% CI 0.2-0.9). Accounting only the CsPCa located in the peripheral zone, sensitivity, specificity, PPV, and NPV raised up to 74%, 75%, 94%, 33%, respectively with AUC 0.75 (95% CI 0.5-0-9). Conclusions: ExactVuTM provides high resolution of the prostatic peripheral zone and could represent a step forward in the detection of CsPCa as a triage tool. Further studies are needed to confirm these promising results.