JMJaruwan Mettakoonpitak

Jaruwan Mettakoonpitak

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jaruwan Mettakoonpitak has a total of 35 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Alcohol ink-modified microfluidic paper-based analytical devices for enhanced white detection in simultaneous determination of multiple water quality indicators

    by Jaruwan Mettakoonpitak, Patcharaporn Hatsakhun, Nichanun Sirasunthorn

    White detection remains a critical limitation in using colorimetry to determine substances with microfluidic paper-based analytical devices (µPADs). Here, we introduced a simple, safe alcohol ink-modified µPAD for the straightforward and facile detection of white color in precipitation reactions. Although absolute alcohol ink was found to cause device leakage, dilution of the ink with water was the key to successfully precoat wax-created µPADs. Device utility was demonstrated through simultaneous detection of sulfate, phosphate, and water hardness via precipitation reactions. While phosphate interfered with sulfate detection by Ba2+, in situ distance-based quantification of phosphate was implemented. Aside from anions, the modified µPADs could be extended to detect cationic analytes such as total hardness. The limits of detection (LODs) for sulfate, phosphate, and hardness were 0.005 mmol L−1, 0.005 mmol L−1, and 0.5 mmol L−1, respectively, with the linear ranges of 0.01–10.0 mmol L−1, 0.005–1.0 mmol L−1, and 0.001–0.5 mol L−1. The µPADs were applied to real water samples, demonstrating results that were consistent with standard methods at a 95% confidence level. By incorporating white detection, these alcohol ink-modified µPADs offer enhanced versatility for addressing a broader array of analytical challenges in real-world settings. Graphical Abstract


  • Microfluidic paper-based analytical devices for simple and nondestructive durian fruit maturity assessment

    by Jaruwan Mettakoonpitak, Atcha Chanthabun, Patcharaporn Hatsakhun, Nichanun Sirasunthorn, Atitaya Siripinyanond, Charles S. Henry


  • Open Access

    User-friendly diameter-based measurement paper sensor for chloride detection in water

    by Benjarat Tasangtong, Thanapit Pholsaptanakorn, Thanakorn Tapsawut, Nisakorn Wiwekwin, Jaruwan Mettakoonpitak, Piyaporn Na Nongkhai, Yupaporn Sameenoi


  • Microfluidic paper-based analytical devices for simultaneous detection of oxidative potential and copper in aerosol samples

    by Jaruwan Mettakoonpitak, Nalatthaporn Sawatdichai, Duangduean Thepnuan, Atitaya Siripinyanond, Charles S. Henry, Somporn Chantara

    The potential reach of point-of-care (POC) diagnostics into daily routines for exposure to reactive oxygen species (ROS) and Cu in aerosolized particulate matter (PM) demands that microfluidic paper-based analytical devices (μPADs) take into consideration the simple detection of these toxic PM components. Here, we propose μPADs with a dual-detection system for simultaneous ROS and Cu(II) detection. For colorimetric ROS detection, the glutathione (GSH) assay with a folding design to delay the reaction yielded complete ROS and GSH oxidation, and improved homogeneity of color development relative to using the lateral flow pattern. For electrochemical Cu(II) determination, 1,10-phenanthroline/Nafion modified graphene screen-printed electrodes showed ability to detect Cu(II) down to pg level being low enough to be applied to PM analysis. No intra- and inter-interference affecting both systems were found. The proposed μPADs obtained LODs for 1,4-naphthoquinone (1,4-NQ), used as the ROS representative, and Cu(II) of 8.3 ng and 3.6 pg, respectively and linear working ranges of 20 to 500 ng for ROS and 1 × 10−2 to 2 × 102 ng for Cu(II). Recovery of the method was between 81.4 and 108.3% for ROS and 80.5–105.3% for Cu(II). Finally, the sensors were utilized for simultaneous ROS and Cu(II) determination in PM samples and the results statistically agreed with those using the conventional methods at 95% confidence. Graphical abstract


  • An electrochemical paper-based analytical sensor for one-step latex protein detection

    by Jaruwan Mettakoonpitak, Preeyanuch Junkong, Aphiwan Saenonphut, Tanagorn Kwamman, Atitaya Siripinyanond, Charles S. Henry

    Exposure to natural rubber latex (NRL) can result in sensitivity to NRL protein with resulting allergic reactions. Low-cost, portable, simple, sensitive analytical tools for NRL protein measurements are needed for rapid and accurate assessments of allergenic risks at the point-of-care (POC) instead of using traditional methods that require large and expensive instruments, long-time analysis, and complex sample preparation steps. Here, an electrochemical paper-based analytical device (ePAD) is presented by combining sample preparation and electrochemical detection within a single device to offer a one-step NRL analysis. The lack of antibodies and/or enzymes against NRL makes POC analysis difficult. In this work, detection is based on electrochemical measurement of the remaining Cu after in situ protein complexation instead of more complex biological assays for the first time. Graphene screen-printed electrodes modified with 1,10-phenanthroline and Nafion were used in the ePAD to improve Cu signal 18-fold relative to unmodified carbon screen-printed electrodes. The optimum parameters including 1,10-phenanthroline concentration, reaction time between Cu and protein, and the starting Cu concentration were 5% w/v, 1 min, and 600 μg mL−1, respectively. In addition to short analysis time (4 min), the system selectivity indicated no other interfering species affecting protein detection. The proposed ePAD achieved an LOD of 3.0 mg dL−1 and a linear range of 10.0–200.0 mg dL−1. Finally, the proposed sensors were applied for NRL protein detection and the results were not significantly different from the traditional Lowry method at 95% confidence.


  • Janus Electrochemical Paper-Based Analytical Devices for Metals Detection in Aerosol Samples

    by Jaruwan Mettakoonpitak, John Volckens, Charles S. Henry

    Exposure to trace metals in airborne particulate matter (PM) has been linked to various adverse health effects. Quantifying metals in PM is important; however, current analytical tools tend to be bulky and expensive. A need therefore exists for more rapid, low-cost, portable tools for multiplexed determination of metals in PM. Electrochemical paper-based devices (ePADs) have been used for detecting metals in PM but require different devices and methods for different metals, making the systems more complicated than desired. Recently reported Janus ePADs offer a solution to this problem by allowing for multiple electrochemical experiments from a single sample. Here, we sought to determine if a Janus ePAD containing four independent channels and working electrodes could be used for simultaneous detection of multiple metals in PM. Online sample pretreatment in each channel during sample delivery yielded optimal conditions for each experiment. The design allows the device to conduct square-wave anodic stripping voltammetry (SWASV) and square-wave cathodic stripping voltammetry (SWCSV) for simultaneous detection of Cd, Pb, Cu, Fe, and Ni from a single sample. Two detection zones each with shared reference and counter electrodes were used for SWASV and SWCSV, respectively. The proposed sensors reached LODs down to 0.5, 0.5, 1.0, 0.5, 1.0 μg L-1, for Cd(II), Pb(II), Cu(II), Fe(II), and Ni(II), respectively. The linear working ranges were 0.5-400.0 μg L-1 for Cd(II), Pb(II), and Fe(II), 1.0-400.0 μg L-1 for Cu(II), and 0.5-200.0 μg L-1 for Ni(II). The devices were applied for Cd(II), Pb(II), Cu(II), Fe(II), and Ni(II) determination in PM samples and the results agreed with those using traditional ICP-MS analyses at 95% confidence.


  • Open Access

    Electrophoretic separations on Parafilm-paper-based analytical devices

    by Jaruwan Mettakoonpitak, Charles S. Henry


  • AgNP/Bi/Nafion‐modified Disposable Electrodes for Sensitive Zn(II), Cd(II), and Pb(II) Detection in Aerosol Samples

    by Jaruwan Mettakoonpitak, John Mehaffy, John Volckens, Charles S. Henry

    A new method for modifying electrodes with Ag nanoparticles (AgNPs) using electrospray deposition for sensitive, selective detection of Zn(II), Cd(II), and Pb(II) in aerosol samples when combined with Bismuth and Nafion coating and square‐wave anodic stripping voltammetry (SWASV) is reported. Carbon stencil‐printed electrodes (CSPEs) fabricated on a polyethylene transparency (PET) sheet were produced for an inexpensive, simple to fabricate, disposable sensor that can be used with the microliter sample volumes for analysis. Sensor performance was improved by modifying the electrode surface with electrospray‐deposited AgNPs. The use of electrospray deposition resulted in more uniform particle dispersion across the electrode surface when compared to drop‐casting. Using AgNP‐modified electrodes combined with Bi and Nafion, experimental detection limits (LODs) of 5.0, 0.5, and 0.1 μg L−1 for Zn(II), Cd(II), and Pb(II), respectively, were achieved. The linear working ranges were 5.0–400.0 μg L−1, 0.5–400.0 μg L−1, and 0.1–500.0 μg L−1 for Zn(II), Cd(II), and Pb(II), respectively. Interference studies showed Cu(II) was the only metal that interfered with this assay but inference could be eliminated with the addition of ferricyanide directly to the sample solution. This electrochemical sensor was applied for the simultaneous determination of Zn(II), Cd(II), and Pb(II) within source particulate matter (PM) samples collected on filters using an aerosol test chamber.