David Williams
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
David Williams has a total of 48 co-authors. Here are the top co-authors by number of shared publications:
- Catherine A. Holt
Biomechanics & Bioengineering Centre Versus Arthritis, Cardiff University, Cardiff, United Kingdom; Cardiff School of Engineering, College of Physical Sciences and Engineering, Cardiff University, Cardiff, United Kingdom
3 shared publications - Gemma Marie Whatling
Cardiff University
2 shared publications - Lauren Welte
Department of Mechanical Engineering, Faculty of Engineering, College of Natural and Applied Sciences, University of Alberta, Edmonton, Canada
2 shared publications - Michael J. Rainbow
Department of Mechanical and Materials Engineering, Queen’s University, Kingston, Canada
2 shared publications - Alberto Leardini
Movement Analysis Laboratory and Functional Evaluation of Prostheses, IRCCS Istituto Ortopedico Rizzoli, Via di Barbiano 1/10, 40136 Bologna, Italy
1 shared publication - Amy L. Lenz
Department of Mechanical Engineering, University of Utah, Salt Lake City, USA
1 shared publication
Latest Publications
- Open Access
- 20 January 2026
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 147 (2) , 02NT01
Less is more: downsampling x-ray images improves pose estimation accuracy
Biplanar videoradiography (BVR) is a gold-standard technique for quantifying in vivo bone motion, yet the influence of x-ray image resolution on pose estimation accuracy remains unexplored. This study investigates how downsampling x-ray images impacts model-based pose estimation, using high-speed BVR data from a participant with implanted tantalum beads. Images were downsampled from 2048 × 2048 to 512 × 512 using bicubic and nearest-neighbour interpolation. Across multiple bones and varying perturbation levels, downsampling significantly reduced rotational and translational errors when compared to full-resolution images for both interpolation results. Bicubic interpolation led to slightly improved pose accuracy for certain bones, demonstrating enhanced edge clarity that benefits the optimisation algorithm. Pose estimates for full-resolution images exhibited more outliers and greater variability for all the bones investigated. These findings highlight that downsampling images improves pose estimation accuracy even for challenging anatomical areas such as the ankle. We recommend bicubic downsampling to 512 × 512 pixels as a best practice for BVR tracking of the ankle complex, when using both automated optimisation and manual workflows.
- 20 January 2026
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 147 (2) , 02NT01
Open AccessLess is more: downsampling x-ray images improves pose estimation accuracy
Biplanar videoradiography (BVR) is a gold-standard technique for quantifying in vivo bone motion, yet the influence of x-ray image resolution on pose estimation accuracy remains unexplored. This study investigates how downsampling x-ray images impacts model-based pose estimation, using high-speed BVR data from a participant with implanted tantalum beads. Images were downsampled from 2048 × 2048 to 512 × 512 using bicubic and nearest-neighbour interpolation. Across multiple bones and varying perturbation levels, downsampling significantly reduced rotational and translational errors when compared to full-resolution images for both interpolation results. Bicubic interpolation led to slightly improved pose accuracy for certain bones, demonstrating enhanced edge clarity that benefits the optimisation algorithm. Pose estimates for full-resolution images exhibited more outliers and greater variability for all the bones investigated. These findings highlight that downsampling images improves pose estimation accuracy even for challenging anatomical areas such as the ankle. We recommend bicubic downsampling to 512 × 512 pixels as a best practice for BVR tracking of the ankle complex, when using both automated optimisation and manual workflows.
- 3 December 2024
- Published by Elsevier in Foot and Ankle Clinics
- Vol. 30 (1) , 221-237
Standardizing 3 Dimensional Measurements in Foot and Ankle Imaging
- 3 December 2024
- Published by Elsevier in Foot and Ankle Clinics
- Vol. 30 (1) , 221-237
Standardizing 3 Dimensional Measurements in Foot and Ankle Imaging
- 11 April 2023
- Published by British Editorial Society of Bone & Joint Surgery in Orthopaedic Proceedings
- Vol. 105-B (SUPP_8) , 98
DEVELOPMENT OF AN IN VIVO ANKLE AND HINDFOOT KINEMATIC PROTOCOL TO INVESTIGATE ACTIVITIES OF DAILY LIVING
DEVELOPMENT OF AN IN VIVO ANKLE AND HINDFOOT KINEMATIC PROTOCOL TO INVESTIGATE ACTIVITIES OF DAILY LIVING
- 11 April 2023
- Published by British Editorial Society of Bone & Joint Surgery in Orthopaedic Proceedings
- Vol. 105-B (SUPP_8) , 98
DEVELOPMENT OF AN IN VIVO ANKLE AND HINDFOOT KINEMATIC PROTOCOL TO INVESTIGATE ACTIVITIES OF DAILY LIVING
DEVELOPMENT OF AN IN VIVO ANKLE AND HINDFOOT KINEMATIC PROTOCOL TO INVESTIGATE ACTIVITIES OF DAILY LIVING
- Open Access
- 1 November 2020
- Published by Elsevier in Journal of Biomechanics
- Vol. 112, 110042
The relationship between alignment, function and loading in total knee replacement: In-vivo analysis of a unique patient population
- 1 November 2020
- Published by Elsevier in Journal of Biomechanics
- Vol. 112, 110042
Open AccessThe relationship between alignment, function and loading in total knee replacement: In-vivo analysis of a unique patient population
- 1 April 2020
- Published by Elsevier in Osteoarthritis and Cartilage
- Vol. 28, S250-S251
Knee joint contact forces during gait for patients undergoing high tibial osteotomy
- 1 April 2020
- Published by Elsevier in Osteoarthritis and Cartilage
- Vol. 28, S250-S251
Knee joint contact forces during gait for patients undergoing high tibial osteotomy
- Open Access
- 1 September 2019
- Published by Taylor & Francis in Orthopedic Research and Reviews
- Vol. ume 11, 129-140
Comparison of gait, functional activities, and patient-reported outcome measures in patients with knee osteoarthritis and healthy adults using 3D motion analysis and activity monitoring: an exploratory case-control analysis
Objective: To examine functional performance differences using kinematic and kinetic analysis between participants with and without knee osteoarthritis (OA) to determine which outcomes best characterize persons with and without knee OA. Methods: Participants with unilateral moderate knee OA (Kellgren–Lawrence grades 2 or 3) and controls without knee pain were matched for age, gender, and body mass index. Primary outcomes included temporal parameters, joint rotations and moments, and ground reaction forces assessed via 3D motion capture during walking and ascending/descending stairs. Secondary outcomes included timed functional activities (sit to stand; tying shoelaces), 48 hrs lower limb activity monitoring, and patient-reported outcome measures (Knee Injury and Osteoarthritis Outcome Score, Western Ontario and McMaster Universities Osteoarthritis Index, European Quality of Life–5 Dimensions). Results: Eight matched pairs were analyzed. Compared with controls, OA participants exhibited significant reductions in peak frontal hip and sagittal knee moments, and decreased peak anterior ground reaction force with the affected limb while walking. Ascending stairs, OA participants had slower speed, fewer strides per minute, longer cycle and stance times, and increased trunk range of motion (ROM) in assessments of both limbs; longer swing time and reduced ankle ROM in the affected limb; and increased knee frontal ROM in the unaffected limb. Descending stairs, OA participants had fewer strides per minute and decreased trunk transverse ROM in assessments of both limbs; increased knee frontal ROM in the affected limb; and longer strides, shorter stance and cycle times, increased trunk sagittal and decreased knee transverse ROMs in the unaffected limbs vs controls. Compared with controls, OA participants had slower walking cadence (120–130 vs 100–110 steps/min, respectively), took significantly longer on timed functional measures, and had significantly worse scores in patient-reported outcomes. Conclusion: Several objectives and patient-reported measures examined in this study could potentially be considered as outcomes in pharmacologic or physical therapy OA trials.
- 1 September 2019
- Published by Taylor & Francis in Orthopedic Research and Reviews
- Vol. ume 11, 129-140
Open AccessComparison of gait, functional activities, and patient-reported outcome measures in patients with knee osteoarthritis and healthy adults using 3D motion analysis and activity monitoring: an exploratory case-control analysis
Objective: To examine functional performance differences using kinematic and kinetic analysis between participants with and without knee osteoarthritis (OA) to determine which outcomes best characterize persons with and without knee OA. Methods: Participants with unilateral moderate knee OA (Kellgren–Lawrence grades 2 or 3) and controls without knee pain were matched for age, gender, and body mass index. Primary outcomes included temporal parameters, joint rotations and moments, and ground reaction forces assessed via 3D motion capture during walking and ascending/descending stairs. Secondary outcomes included timed functional activities (sit to stand; tying shoelaces), 48 hrs lower limb activity monitoring, and patient-reported outcome measures (Knee Injury and Osteoarthritis Outcome Score, Western Ontario and McMaster Universities Osteoarthritis Index, European Quality of Life–5 Dimensions). Results: Eight matched pairs were analyzed. Compared with controls, OA participants exhibited significant reductions in peak frontal hip and sagittal knee moments, and decreased peak anterior ground reaction force with the affected limb while walking. Ascending stairs, OA participants had slower speed, fewer strides per minute, longer cycle and stance times, and increased trunk range of motion (ROM) in assessments of both limbs; longer swing time and reduced ankle ROM in the affected limb; and increased knee frontal ROM in the unaffected limb. Descending stairs, OA participants had fewer strides per minute and decreased trunk transverse ROM in assessments of both limbs; increased knee frontal ROM in the affected limb; and longer strides, shorter stance and cycle times, increased trunk sagittal and decreased knee transverse ROMs in the unaffected limbs vs controls. Compared with controls, OA participants had slower walking cadence (120–130 vs 100–110 steps/min, respectively), took significantly longer on timed functional measures, and had significantly worse scores in patient-reported outcomes. Conclusion: Several objectives and patient-reported measures examined in this study could potentially be considered as outcomes in pharmacologic or physical therapy OA trials.