Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Christoph Braig has a total of 49 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Experimental verification of soft X-ray imaging and RIXS mapping with a reflection zone plate

    by Jens Rehanek, Christoph Braig, Heike Löchel, Felix Marschall, Martin Beye, Dirk Raiser, Sreevidya Thekku Veedu, Benedikt Rösner, Florian Döring, Jens Buck, et al.

    We demonstrate two-dimensional (2-D) imaging and resonant inelastic X-ray scattering (RIXS) spectroscopy in the hν 2 “mapping” scheme using a reflection zone plate (RZP) at soft X-rays. Experiments at the PETRA III storage ring (DESY) around the N K α line (392.4 eV) verify that an RZP can be used in the paraxial regime combined with the 1-D line scanning mode for time-efficient full-field imaging of an extended object with an angular size of 2.5 mrad at low aberrations, even for off-design energies, at a spatial resolution of (14–24) μ m. A similar setup collects the RIXS spectra of acetonitrile within (388.6–401.8) eV for a variable incident photon energy between 399 eV and 400 eV, at a potential resolution of (0.3 ± 0.1) eV. RZPs with their precise manufacturability, efficiency, and strong dispersion can serve as advantageous diffractive optical elements in soft X-ray microscopy or “photon-in vs. photon-out” spectroscopy.

  • Open Access

    Diffractive wavefront correction for Fe L -edge spectroscopy on the meV scale

    by Christoph Braig, Andrey Sokolov, Frank Siewert, Christian Seifert

    We propose a wavelength-dispersive instrument for high-resolution soft X-ray spectroscopy at large-scale facilities like synchrotron radiation sources or free-electron lasers. Demonstrated by simulations at the Fe L -edge in the range from 700 eV to 730 eV, an energy resolution of (12–15) meV is enabled by a wavefront-corrected reflection zone plate (RZP) with an aperture of 40 mm × 190 mm on a spherical Si substrate (radius 69 m). Its tangential slope error and deformation are measured on-axis along the RZP to ±0.1 arcsec (r.m.s.) and ±6.1 nm (r.m.s.), respectively, and simulated at off-axis positions of the substrate with a similar amplitude. The surface waviness is compensated around the design energy of 715 eV by a two-dimensional, adapted grating groove distribution. As a benefit, the diffracted beam is collimated to a one-dimensional focal line whose length of 40 mm nearly equals the sagittal detector size (50 mm): no photons in the +1st diffraction order with an efficiency of 6.4% are lost, and the acceptance solid angle of 16 mrad × 3.3 mrad provides a high transmission of the signal from the source.

  • Open Access

    A reflection zone plate for parallelized soft x-ray spectroscopy at the Fe L3-edge

    by C. Braig, A. Fernández Herrero, M. Brzhezinskaya, J. Probst, C. Seifert

    We design an advanced reflective–diffractive optical element (DOE) for high-resolution, parallelized soft x-ray spectroscopy of, e.g., transition metals, here optimized for the Fe L3-edge around 706.8 eV, and demonstrate its functionality in simulations. Based on a “hybrid” reflection zone plate (RZP) on a spherical substrate, which maintains aberration-corrected focusing under a wide angular acceptance of 8.5 msr, slightly slanted grating grooves transpose the wavelength dispersion in the (−1)st diffraction order from the vertical (z) direction partially into the horizontal (y) direction, and the signal can be read out at MHz rates from a pixelated (50 μm) line detector behind an exit slit. As an advantage over conventional variable line-space gratings of equal aperture, constant resolving power is achieved across the full range of 695–715 eV. The transmission efficiency Pt and the energy resolution ΔE scale in proportion to the adjustable slit width Δh. For a source of (1.0 × 0.3) μm2 in size and Δh = 5 μm, we expect from simulations Pt ≈ 0.3% and ΔE ≈ 0.26 eV, with great potential for their ratio Pt/ΔE to be tuned. The substrate curvature of 4.5 m and the line densities ≲7.19 × 102 mm−1 are compatible with the fabrication of the Ni-coated RZP by laser lithography. In-vacuum and tabletop operation are supported by an optical path length of 490 mm. We derive the vector field of the DOE, simulate its optical function, and characterize the performance for a variable source size. Conceptual extensions for laboratories and large-scale facilities are discussed.

  • Open Access

    Soft X-ray wavefront sensing at an ellipsoidal mirror shell

    by Christoph Braig, Jürgen Probst, Heike Löchel, Ladislav Pina, Thomas Krist, Christian Seifert

    A reliable `in situ' method for wavefront sensing in the soft X-ray domain is reported, developed for the characterization of rotationally symmetric optical elements, like an ellipsoidal mirror shell. In a laboratory setup, the mirror sample is irradiated by an electron-excited (4.4 keV), micrometre-sized (∼2 µm) fluorescence source (carbonKα, 277 eV). Substantially, the three-dimensional intensity distributionI(r) is recorded by a CCD camera (2048 × 512 pixels of 13.5 µm) at two positions along the optical axis, symmetrically displaced by ±21–25% from the focus. The transport-of-intensity equation is interpreted in a geometrical sense from plane to plane and implemented as a ray tracing code, to retrieve the phase Φ(r) from the radial intensity gradient on a sub-pixel scale. For reasons of statistical reliability, five intra-/extra-focal CCD image pairs are evaluated and averaged to an annular two-dimensional map of the wavefront error {\cal W}. In units of the test wavelength (C Kα), an r.m.s. value \sigma_{\cal{W}} = ±10.9λ0and a peak-to-valley amplitude of ±31.3λ0are obtained. By means of the wavefront, the focus is first reconstructed with a result for its diameter of 38.4 µm, close to the direct experimental observation of 39.4 µm (FWHM). Secondly, figure and slope errors of the ellipsoid are characterized with an average of ±1.14 µm and ±8.8 arcsec (r.m.s.), respectively, the latter in reasonable agreement with the measured focal intensity distribution. The findings enable, amongst others, the precise alignment of axisymmetric X-ray mirrors or the design of a wavefront corrector for high-resolution X-ray science.

  • Collimation by a polycapillary half lens at 277 eV

    by Jürgen Probst, Heike Löchel, Markus Thiel, Semfira Bjeoumikhova, Christoph Braig, Christian Seifert

    We report on the efficient collimation of soft X-rays with an energy of 277 eV by a halved polycapillary lens (PCL), made of borosilicate glass. Using electron-excited, micro fluorescence emission in the focus of the PCL, experiments reveal an angular divergence of (6.9 +/- 0.2) mrad in the far field of the emitted beam. For a source of approximate to 5 mu m in size, that result is confirmed by simulations, obtained with a newly developed ray tracing code. An analytical fit model is proposed and applied to characterize the evolution of the measured as well as calculated, three-dimensional (3-D) intensity distribution. The photon flux density in a free-space propagation distance of (0.4 - 0.9) m from the PCL is enhanced by a factor of approximate to(30 - 90) in comparison to the direct, not collimated radiation, as it is detected through a mm-sized transmission slit. Our findings could help to establish the halved PCL as a versatile tool in the table-top metrology of optical elements, such as mirrors and gratings for soft X-rays.(c) 2023 Optica Publishing Group under the terms of the Optica Open Access Publishing Agreement

  • Open Access

    Polycapillary-boosted instrument performance in the extreme ultraviolet regime for inverse photoemission spectroscopy: erratum

    by Christoph Braig, Andrey Sokolov, Regan G. Wilks, Xeniya Kozina, Thomas Kunze, Semfira Bjeoumikhova, Markus Thiel, Alexei Erko, Marcus Bär

    We correct values and figures for the resolution of the spectrometer, as proposed in [ Opt. Express 25, 31840 (2017)10.1364/OE.25.031840 OPEXFF 1094-4087 ]. The new results take into account previously unknown, incoherent phase fluctuations, caused by the polycapillary lens (PCL), and estimate the realistic performance of the instrument.

  • Open Access

    Broadband Time-Delay and Chirp Compensator for X-ray Pulses

    by Christoph Braig, Alexei Erko

    A new type of aberration-corrected time-delay compensating monochromator (TDCM) for soft X-rays is presented. Composed of two identical reflection zone plates (RZPs) on spherical substrates and an intermediate flat mirror for band-pass selection, the TDCM can operate in a wide energy range of about ±20% around the design energy of 410eV. Assuming a source size of 50μm and an angular acceptance of 1 mrad, the spectral resolving power may reach 6×102, at a pulse length as short as 4.3femtoseconds(fs). In the case of μm-sized sources, the resolution can be better than 0.1eV and the sub-fs regime could become accessible. The overall transmission efficiency varies within (4.2–6.0)% across the energy range (310–510) eV. In the complementary mode, chirped-pulse compression works as well. Depending on the properties of the source, simulations predict an up to 9-fold reduction in pulse duration, whereas ≤50% of the peak intensity is maintained.


  • Open Access

    Highly efficient soft x-ray spectrometer for transient absorption spectroscopy with broadband table-top high harmonic sources

    by Carlo Kleine, Maria Ekimova, Marc-Oliver Winghart, Sebastian Eckert, Oliver Reichel, Heike Löchel, Jürgen Probst, Christoph Braig, Christian Seifert, Alexei Erko, et al.

    We present a novel soft x-ray spectrometer for ultrafast absorption spectroscopy utilizing table-top femtosecond high-order harmonic sources. Where most commercially available spectrometers rely on spherical variable line space gratings with a typical efficiency on the order of 3% in the first diffractive order, this spectrometer, based on a Hettrick–Underwood design, includes a reflective zone plate as a dispersive element. An improved efficiency of 12% at the N K-edge is achieved, accompanied by a resolving power of 890. The high performance of the soft x-ray spectrometer is further demonstrated by comparing nitrogen K-edge absorption spectra from calcium nitrate in aqueous solution obtained with our high-order harmonic source to previous measurements performed at the electron storage ring facility BESSY II.


  • Open Access

    Flat Field Soft X-ray Spectrometry with Reflection Zone Plates on a Curved Substrate

    by Jürgen Probst, Christoph Braig, Alexei Erko

    We report on the first experimental results obtained with a newly designed instrument for high-resolution soft X-ray spectroscopy, using reflection zone plates (RZPs) on a spherical substrate. The spectrometer was tested with a fluorescence source. High-resolution flat field spectra within ±50% around the design energies were measured at an interval of 150–750 eV, using only two RZPs: the first RZP, with its design energy of 277 eV, covered the band of 150–370 eV, and the second RZP, with a design energy of 459 eV, covered the band of 350–750 eV, where the upper boundary of this energy range was defined by the Ni coating of the RZPs. The absolute quantum efficiency of the spectrometer, including the optical element and the detector, was, on average, above 10%, and reached 20% at the designed energies of the RZPs. The resolving power E/∆E exceeded 600 for energies E inside the core range of 200–550 eV.


  • Carbon-based Fresnel optics for hard x-ray astronomy

    by Christoph Braig, Ivo Zizak

    We investigate the potential of large-scale diffractive-refractive normal-incidence transmission lenses for the development of space-based hard x-ray telescopes with an angular resolution in the range of (10−6–10−3) arcsec over a field of view that is restricted by the available detector size. Coherently stepped achromatic lenses with diameters up to 5 m for compact apertures and 13 m in the case of segmentation provide an access to spectrally resolved imaging within keV-wide bands around the design energy between 10 and 30 keV. Within an integration time of 106 s, a photon-limited 5σ sensitivity down to (10−9–10−7) s−1 cm−2 keV−1 can be achieved depending on the specific design. An appropriate fabrication strategy, feasible nowadays with micro-optical technologies, is considered and relies on the availability of high-purity carbon or polymer membranes. X-ray fluorescence measurements of various commercially available carbon-based materials prove for most of them the existence of a virtually negligible contamination by critical trace elements such as transition metals on the ppm level.