Ehsan Gatavi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ehsan Gatavi has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
Ali Hellany
School of Engineering, Western Sydney University, Sydney, Australia
5 shared publicationsJamal Rizk
School of Engineering, Western Sydney University, Sydney, Australia
5 shared publicationsMahmood Nagrial
School of Engineering, Western Sydney University, Sydney, Australia
5 shared publications- Abdul Rashid Husain
Universiti Teknologi Malaysia
2 shared publications A. Hellany
School of Computing, Engineering and Mathematics Western Sydney University Australia
1 shared publicationA.H. Shirdel
1 shared publication
Latest Publications
- Open Access
- 6 November 2025
- Published by MDPI AG in World Electric Vehicle Journal
- Vol. 16 (11) , 610
Feasibility Analysis and Optimisation of Vehicle-Integrated Photovoltaic (VIPV) Systems for Sustainable Transportation
This paper investigates the feasibility of vehicle-integrated photovoltaic (VIPV) systems for light vehicles by developing and simulating an intelligent solar integration design based on the Tesla Model 3. The proposed system incorporates roof and bonnet-mounted photovoltaic modules, each managed by independent buck converters employing maximum power point tracking (MPPT) for optimal energy extraction. A novel fuzzy logic controller was designed to dynamically allocate auxiliary battery charging between the traction battery and the solar subsystem, using real-time irradiance and state-of-charge (SOC) inputs. The system was implemented in MATLAB/Simulink with location-specific data for Melbourne, Australia. Simulation results demonstrate high converter efficiencies of 94–95%, stable MPPT convergence within 0.5 s and an estimated annual solar contribution of 930 kWh, confirming effective control and energy management under varying conditions. This work highlights the innovative application of adaptive fuzzy control and dual MPPT coordination within VIPV systems and provides a validated basis for future optimisation and real-world integration.
- 6 November 2025
- Published by MDPI AG in World Electric Vehicle Journal
- Vol. 16 (11) , 610
Open AccessFeasibility Analysis and Optimisation of Vehicle-Integrated Photovoltaic (VIPV) Systems for Sustainable Transportation
This paper investigates the feasibility of vehicle-integrated photovoltaic (VIPV) systems for light vehicles by developing and simulating an intelligent solar integration design based on the Tesla Model 3. The proposed system incorporates roof and bonnet-mounted photovoltaic modules, each managed by independent buck converters employing maximum power point tracking (MPPT) for optimal energy extraction. A novel fuzzy logic controller was designed to dynamically allocate auxiliary battery charging between the traction battery and the solar subsystem, using real-time irradiance and state-of-charge (SOC) inputs. The system was implemented in MATLAB/Simulink with location-specific data for Melbourne, Australia. Simulation results demonstrate high converter efficiencies of 94–95%, stable MPPT convergence within 0.5 s and an estimated annual solar contribution of 930 kWh, confirming effective control and energy management under varying conditions. This work highlights the innovative application of adaptive fuzzy control and dual MPPT coordination within VIPV systems and provides a validated basis for future optimisation and real-world integration.
- 1 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 162-167
Improved HVDC Reactive Power Control Using Fuzzy PI
With the growing use of alternate power generation sources such as wind and solar, HVDC systems are an important enabler for power distribution between grids and enable a range of alternate sources connecting to the grid. Unlike AC systems, the HVDC system does not suffer from reactive power losses providing greater efficiency for power transmission. Minimizing reactive power, therefore, increases efficiency. However, in a transmission system, reactive power is useful in maintaining a stable voltage and improving fault recovery within the system. Due to DC transmission requiring the use of power electronics, especially in the area of Voltage Source Converters (VSC) HVDC converters, the controllability of DC allows for full control over the transmitted active and reactive power independently. In this paper, combining the fast responsive nature of the PI controller with the robust damping capabilities of the fuzzy logic controller is applied to gain better control when clearing faults.
- 1 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 162-167
Improved HVDC Reactive Power Control Using Fuzzy PI
With the growing use of alternate power generation sources such as wind and solar, HVDC systems are an important enabler for power distribution between grids and enable a range of alternate sources connecting to the grid. Unlike AC systems, the HVDC system does not suffer from reactive power losses providing greater efficiency for power transmission. Minimizing reactive power, therefore, increases efficiency. However, in a transmission system, reactive power is useful in maintaining a stable voltage and improving fault recovery within the system. Due to DC transmission requiring the use of power electronics, especially in the area of Voltage Source Converters (VSC) HVDC converters, the controllability of DC allows for full control over the transmitted active and reactive power independently. In this paper, combining the fast responsive nature of the PI controller with the robust damping capabilities of the fuzzy logic controller is applied to gain better control when clearing faults.
- 16 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 847-851
Decentralised Fault Tolerant Model Predictive Control for a Class of Interconnected System
A decentralised fault tolerant control is presented in this paper for a class of interconnected system. The bounded control technique is applied to address the interconnection effects and the dynamic changes due to the faults. Multiple local controllers are designed as part of decentralised algorithm to guarantee the system stability during the fault period. In this case, the system can deal with the fault with large magnitude. To illustrate the effectiveness the proposed scheme, the system is tested for the case that multiple fault occurred in different local subsystems.
- 16 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 847-851
Decentralised Fault Tolerant Model Predictive Control for a Class of Interconnected System
A decentralised fault tolerant control is presented in this paper for a class of interconnected system. The bounded control technique is applied to address the interconnection effects and the dynamic changes due to the faults. Multiple local controllers are designed as part of decentralised algorithm to guarantee the system stability during the fault period. In this case, the system can deal with the fault with large magnitude. To illustrate the effectiveness the proposed scheme, the system is tested for the case that multiple fault occurred in different local subsystems.
- 1 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Chinese Journal of Electrical Engineering
- Vol. 5 (4) , 1-14
An integrated reactive power control strategy for improving low voltage ride-through capability
- 1 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Chinese Journal of Electrical Engineering
- Vol. 5 (4) , 1-14
An integrated reactive power control strategy for improving low voltage ride-through capability
- 1 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Advanced Reactive Power Control Strategy for Better LVRT Capability for DFIG-based Wind Farm
A new reactive power control strategy is presented in this paper for voltage stability and improvement of low voltage ride through (LVRT) capability. Both rotor side converter (RSC) and grid side converter (GSC) are taken into account for the purpose of voltage stability and improvement of system's robustness. In this algorithm, the required reactive power is optimally managed at an individual point of common coupling (PCC) by using linear matrix inequality (LMI) technique. Jacobian matrix (J R ) is also employed to have better accuracy and realize the required bound of injected reactive power. To minimize the system's conservative nature, dynamic couplings of the system are considered, unlike the existing methods. Results and simulations are discussed in more details to illustrate the effectiveness of the proposed method.
- 1 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Advanced Reactive Power Control Strategy for Better LVRT Capability for DFIG-based Wind Farm
A new reactive power control strategy is presented in this paper for voltage stability and improvement of low voltage ride through (LVRT) capability. Both rotor side converter (RSC) and grid side converter (GSC) are taken into account for the purpose of voltage stability and improvement of system's robustness. In this algorithm, the required reactive power is optimally managed at an individual point of common coupling (PCC) by using linear matrix inequality (LMI) technique. Jacobian matrix (J R ) is also employed to have better accuracy and realize the required bound of injected reactive power. To minimize the system's conservative nature, dynamic couplings of the system are considered, unlike the existing methods. Results and simulations are discussed in more details to illustrate the effectiveness of the proposed method.
- 1 April 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Improved Low Voltage Ride-Through capability of DFIG-based wind turbine with breaking resistor and converter control
This paper presents a control strategy to improve Low Voltage Ride-Through (LVRT) capability by integrating Series Dynamic Braking Resistor (SDBR) into the converter control algorithm. The required reactive power is controlled by employing Model Predictive Control (MPC) and incorporating the voltage and the current constraints to the control task to avoid losing active and reactive power control. A model of Wind Turbine (WT) equipped with Doubly Fed Induction Generator (DFIG) is also presented in this paper. A numerical example is simulated in MATLAB to illustrate the effectiveness of the proposed method.
- 1 April 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Improved Low Voltage Ride-Through capability of DFIG-based wind turbine with breaking resistor and converter control
This paper presents a control strategy to improve Low Voltage Ride-Through (LVRT) capability by integrating Series Dynamic Braking Resistor (SDBR) into the converter control algorithm. The required reactive power is controlled by employing Model Predictive Control (MPC) and incorporating the voltage and the current constraints to the control task to avoid losing active and reactive power control. A model of Wind Turbine (WT) equipped with Doubly Fed Induction Generator (DFIG) is also presented in this paper. A numerical example is simulated in MATLAB to illustrate the effectiveness of the proposed method.
- 1 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Dynamic reactive power in compliance with low voltage ride-through enhancement for DFIG-based wind turbine
Wind power plant is regarded as a large-scale system where the interconnections between each subsystem cannot be neglected, otherwise the control strategy cannot guarantee the robustness and system satisfactory efficiency over a wide range of operation. Moreover, voltage stability is the most important ancillary service to preserve doubly fed induction generator (DFIG) connected to the grid during fault, known as Low Voltage Ride-Through (LVRT). In this paper, multiple local controller strategy is introduced to improve LVRT capability and to guarantee the system-wise stability. However, voltage at individual point of common coupling (PCC) is controlled to minimize the risk of instability because of high flow reactive power. Unlike classical decentralized methods, all energy and material flows are bounded by real constraints in this paper. A model of wind farm equipped with DFIG is also introduced to illustrate the effectiveness of proposed algorithm.
- 1 October 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Dynamic reactive power in compliance with low voltage ride-through enhancement for DFIG-based wind turbine
Wind power plant is regarded as a large-scale system where the interconnections between each subsystem cannot be neglected, otherwise the control strategy cannot guarantee the robustness and system satisfactory efficiency over a wide range of operation. Moreover, voltage stability is the most important ancillary service to preserve doubly fed induction generator (DFIG) connected to the grid during fault, known as Low Voltage Ride-Through (LVRT). In this paper, multiple local controller strategy is introduced to improve LVRT capability and to guarantee the system-wise stability. However, voltage at individual point of common coupling (PCC) is controlled to minimize the risk of instability because of high flow reactive power. Unlike classical decentralized methods, all energy and material flows are bounded by real constraints in this paper. A model of wind farm equipped with DFIG is also introduced to illustrate the effectiveness of proposed algorithm.
- 1 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 23, 1-6
Low voltage ride-through enhancement in DFIG-based wind turbine
Wind farms are regarded as large-scale power plants with interconnected systems, where all systems interact with each other to improve the efficiency of the plant and thus enhance the quality of the output power. However, the conventional centralized controller is inappropriate for such plants. Accordingly, the plant-wise controller is an alternative solution to be plant-wise decentralized, by designing the separate local controller of each subsystem. Moreover, voltage stability plays a significant role to preserve the Doubly Fed Induction Generator (DFIG) based Wind Farms (WF) connected to the grid, which is known as Low-Voltage-Ride-Through (LVRT), in the period of fault appearance. This paper describes a critical review on the existing control methods of the LVRT enhancement in DFIG-based WTs, and also presents the significance of the LVRT capacity improvement to enhance the power quality and guarantee the plant-wise stability during the grid faults.
- 1 October 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 23, 1-6
Low voltage ride-through enhancement in DFIG-based wind turbine
Wind farms are regarded as large-scale power plants with interconnected systems, where all systems interact with each other to improve the efficiency of the plant and thus enhance the quality of the output power. However, the conventional centralized controller is inappropriate for such plants. Accordingly, the plant-wise controller is an alternative solution to be plant-wise decentralized, by designing the separate local controller of each subsystem. Moreover, voltage stability plays a significant role to preserve the Doubly Fed Induction Generator (DFIG) based Wind Farms (WF) connected to the grid, which is known as Low-Voltage-Ride-Through (LVRT), in the period of fault appearance. This paper describes a critical review on the existing control methods of the LVRT enhancement in DFIG-based WTs, and also presents the significance of the LVRT capacity improvement to enhance the power quality and guarantee the plant-wise stability during the grid faults.
- 22 October 2014
- Published by ASME International
Model Predictive Control of DFIG-Based Wind Turbine
This paper presents a centralized multivariable control strategy for the control of the DFIG wind turbine. Model of one-mass wind turbine with DFIG is represented by a third-order model. Model predictive control is applied in order to compensate inaccuracies and measurement noise. The optimization problem is recast as a Quadratic Program (QP) which is highly robust and efficient. In order to bring the problematic voltages as closely as possible to the desired values, multi-step optimization is introduced. The effectiveness of the proposed algorithm is demonstrated for a variable speed wind turbine.
- 22 October 2014
- Published by ASME International
Model Predictive Control of DFIG-Based Wind Turbine
This paper presents a centralized multivariable control strategy for the control of the DFIG wind turbine. Model of one-mass wind turbine with DFIG is represented by a third-order model. Model predictive control is applied in order to compensate inaccuracies and measurement noise. The optimization problem is recast as a Quadratic Program (QP) which is highly robust and efficient. In order to bring the problematic voltages as closely as possible to the desired values, multi-step optimization is introduced. The effectiveness of the proposed algorithm is demonstrated for a variable speed wind turbine.
- 1 April 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
On the design of output feedback sliding mode control for a class of uncertain system
In this study, output feedback sliding mode control (OFSMC) is proposed for a class of system with the uncertainties present in its output matrix. The uncertain output exist in practical system is mainly due to measurement error contributed by sensor noise or low measurement resolution. Sliding Mode Control (SMC) approach is able to provide a promisable solution due to its robustness toward system uncertainties and disturbances, However, OFSMC has imposed a greater challenge due to inaccessibility to all of the system states. In this work, an OFSMC is designed in which the actual system output will follow the desired trajectory in spite of the presence of uncertainties. The control law is designed based on Lyapunov function which the proposed controller guarantees the asymptotic convergence of the output. The sliding surface is formulated such that stability of the reduced-order system is maintained and the convex formulation of the problem is solved by using Linear Matrix Inequality (LMI). Simulation result based on a numerical example is obtained to demonstrate the efficacy of proposed method.
- 1 April 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
On the design of output feedback sliding mode control for a class of uncertain system
In this study, output feedback sliding mode control (OFSMC) is proposed for a class of system with the uncertainties present in its output matrix. The uncertain output exist in practical system is mainly due to measurement error contributed by sensor noise or low measurement resolution. Sliding Mode Control (SMC) approach is able to provide a promisable solution due to its robustness toward system uncertainties and disturbances, However, OFSMC has imposed a greater challenge due to inaccessibility to all of the system states. In this work, an OFSMC is designed in which the actual system output will follow the desired trajectory in spite of the presence of uncertainties. The control law is designed based on Lyapunov function which the proposed controller guarantees the asymptotic convergence of the output. The sliding surface is formulated such that stability of the reduced-order system is maintained and the convex formulation of the problem is solved by using Linear Matrix Inequality (LMI). Simulation result based on a numerical example is obtained to demonstrate the efficacy of proposed method.