Mazen Ahmed Attia
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mazen Ahmed Attia has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Tamer E. Shokry
Head of Fixed Prosthodontics Department, Faculty of Oral and Dental Medicine, Al-Azhar Univerisity
4 shared publications - Mohamed Radwan
Lecturer, Department of Fixed Prosthodontics, Faculty of Dentistry, Beni-Suef University, Beni-Suef, Egypt
3 shared publications - Ahmed Arafa
Lecturer, Department of Fixed Prosthodontics, Faculty of Dentistry, Beni-Suef University, Beni-Suef, Egypt
2 shared publications - Tamer A. Hamza
Department of Fixed Prosthodontics, Faculty of Dentistry, Badr University in Cairo, Cairo, Egypt
2 shared publications Ahmed Abdelrahman
Faculty of Dentistry, MTI University, Cairo, Egypt
1 shared publicationAhmed Tawfik
PhD Researcher, EPSRC Future Advanced Metrology Hub, University of Huddersfield, Huddersfield, United Kingdom
1 shared publication
Latest Publications
- 6 January 2026
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 135 (6) , e132-e139
Effect of different fabrication techniques on the fracture resistance of polyetheretherketone implant-supported posterior crowns: An in vitro study
- 6 January 2026
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 135 (6) , e132-e139
Effect of different fabrication techniques on the fracture resistance of polyetheretherketone implant-supported posterior crowns: An in vitro study
- 5 October 2023
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 130 (6) , 908.e1-908.e8
Effect of different sintering protocols on the fracture strength of 3-unit monolithic gradient zirconia fixed partial dentures: An in vitro study
- 5 October 2023
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 130 (6) , 908.e1-908.e8
Effect of different sintering protocols on the fracture strength of 3-unit monolithic gradient zirconia fixed partial dentures: An in vitro study
- 1 August 2023
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 130 (2) , 242-249
Effect of dynamic loading on fracture resistance of gradient zirconia fixed partial denture frameworks
- 1 August 2023
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 130 (2) , 242-249
Effect of dynamic loading on fracture resistance of gradient zirconia fixed partial denture frameworks
- 16 April 2023
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 129 (6) , 906.e1-906.e10
Micro-CT analysis of marginal and internal fit of milled and pressed polyetheretherketone single crowns
- 16 April 2023
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 129 (6) , 906.e1-906.e10
Micro-CT analysis of marginal and internal fit of milled and pressed polyetheretherketone single crowns
- Open Access
- 1 April 2023
- Published by Egyptian Knowledge Bank in Egyptian Dental Journal
- Vol. 69 (2) , 1397-1407
Influence of surface treatment and thermocycling on porcelain bonding to two forms of titanium
Purpose. is investigate the influence of surface treatment and thermocycling on porcelain bonding to two forms of titanium. Material and methods. 40 specimens (25x3x0.5 mm) were machined by using wire-cut electric discharge machining (WEDM) technology and assigned into 2 groups as per the material form (n=20): Cp Ti grade 2 and Ti-6Al-4V alloy. The specimens were further assigned into 2 subgroups (n=10) as per the tested surface treatment: airborne-particle abrasion and hydrochloric acid treatment. Ni-Cr alloy specimens (n=10) were provided as a control. Ultra-low fusing porcelain was applied at the center of the treated titanium specimens. Half of the titanium specimens in each subgroup were subjected to 5000 cycles of thermocycling in water (n=5). Flexural bond strength measurements for all specimens were determined by using a universal testing machine . A representative specimen was observed by using a scanning electron microscope . Data were analyzed statistically by using 2-way ANOVA and the Student-Newman-Keuls (SNK) post hoc tests (α=.05). Results. No statistically significant difference in bond strength was found between both forms of titanium and the control group (P=.805). In addition, the effect of surface treatment and thermocycling on porcelain bonding to both forms of titanium was not statistically significant (P=.481 and .864). Conclusions. The bond strength of both forms of titanium (Cp Ti grade 2 and Ti-6Al-4V alloy) to ultra-low fusing porcelain was comparable to that of the control group. Both airborne-particle abrasion and hydrochloric acid treatment improved porcelain bonding to both forms of titanium.
- 1 April 2023
- Published by Egyptian Knowledge Bank in Egyptian Dental Journal
- Vol. 69 (2) , 1397-1407
Open AccessInfluence of surface treatment and thermocycling on porcelain bonding to two forms of titanium
Purpose. is investigate the influence of surface treatment and thermocycling on porcelain bonding to two forms of titanium. Material and methods. 40 specimens (25x3x0.5 mm) were machined by using wire-cut electric discharge machining (WEDM) technology and assigned into 2 groups as per the material form (n=20): Cp Ti grade 2 and Ti-6Al-4V alloy. The specimens were further assigned into 2 subgroups (n=10) as per the tested surface treatment: airborne-particle abrasion and hydrochloric acid treatment. Ni-Cr alloy specimens (n=10) were provided as a control. Ultra-low fusing porcelain was applied at the center of the treated titanium specimens. Half of the titanium specimens in each subgroup were subjected to 5000 cycles of thermocycling in water (n=5). Flexural bond strength measurements for all specimens were determined by using a universal testing machine . A representative specimen was observed by using a scanning electron microscope . Data were analyzed statistically by using 2-way ANOVA and the Student-Newman-Keuls (SNK) post hoc tests (α=.05). Results. No statistically significant difference in bond strength was found between both forms of titanium and the control group (P=.805). In addition, the effect of surface treatment and thermocycling on porcelain bonding to both forms of titanium was not statistically significant (P=.481 and .864). Conclusions. The bond strength of both forms of titanium (Cp Ti grade 2 and Ti-6Al-4V alloy) to ultra-low fusing porcelain was comparable to that of the control group. Both airborne-particle abrasion and hydrochloric acid treatment improved porcelain bonding to both forms of titanium.
- Open Access
- 1 October 2022
- Published by Egyptian Knowledge Bank in Egyptian Dental Journal
- Vol. 68 (4) , 3519-3530
Effect of staining solutions on color and translucency change of different monolithic CAD-CAM ceramic materials
Purpose: assess effect of staining solutions on color and translucency change of different monolithic CAD-CAM ceramic materials. Materials and methods: 66 rectangular-shaped specimens milled from different CAD-CAM ceramic materials and divided into 3 groups (n = 22): ZLS group, zirconia-reinforced lithium silicate; ZR group, 4 mol% yttria-stabilized tetragonal zirconia polycrystal (4Y-TZP); and LD group, lithium disilicate glass-ceramic. Each group subdivided into 2 subgroups (n = 11) according to staining solution used (coffee and distilled water). The specimens’ color and translucency parameter (TP) were evaluated at baseline and after staining procedures. Changes in color (ΔE) and translucency parameter (ΔTP) were calculated. One-way ANOVA followed by Tukey’s post hoc test used if ANOVA showed a significant p‑value (p < 0.05). Results: Staining solutions had a significant impact on color change (ΔE) and translucency parameter change (ΔTP) of all tested specimens. Coffee had the most significant effect on ΔE where LD group recorded the largest ΔE (13.07 ±1.49) and ZLS group showed the smallest ΔE (5.21 ±1.37). Also, coffee had the most significant effect on ΔTP where ZR group recorded the largest ΔTP (3.3 ±0.07) and LD group recorded the smallest ΔTP (-0.5 ±0.2). Conclusions: Color and translucency parameters of tested CAD-CAM ceramic materials were significantly influenced by staining solutions. ZLS group showed significantly least color change than ZR and LD groups. ZLS group showed significantly highest translucency parameter initially (baseline) and after staining procedures than ZR and LD groups while LD group revealed significantly least translucency change than ZR and ZLS groups.
- 1 October 2022
- Published by Egyptian Knowledge Bank in Egyptian Dental Journal
- Vol. 68 (4) , 3519-3530
Open AccessEffect of staining solutions on color and translucency change of different monolithic CAD-CAM ceramic materials
Purpose: assess effect of staining solutions on color and translucency change of different monolithic CAD-CAM ceramic materials. Materials and methods: 66 rectangular-shaped specimens milled from different CAD-CAM ceramic materials and divided into 3 groups (n = 22): ZLS group, zirconia-reinforced lithium silicate; ZR group, 4 mol% yttria-stabilized tetragonal zirconia polycrystal (4Y-TZP); and LD group, lithium disilicate glass-ceramic. Each group subdivided into 2 subgroups (n = 11) according to staining solution used (coffee and distilled water). The specimens’ color and translucency parameter (TP) were evaluated at baseline and after staining procedures. Changes in color (ΔE) and translucency parameter (ΔTP) were calculated. One-way ANOVA followed by Tukey’s post hoc test used if ANOVA showed a significant p‑value (p < 0.05). Results: Staining solutions had a significant impact on color change (ΔE) and translucency parameter change (ΔTP) of all tested specimens. Coffee had the most significant effect on ΔE where LD group recorded the largest ΔE (13.07 ±1.49) and ZLS group showed the smallest ΔE (5.21 ±1.37). Also, coffee had the most significant effect on ΔTP where ZR group recorded the largest ΔTP (3.3 ±0.07) and LD group recorded the smallest ΔTP (-0.5 ±0.2). Conclusions: Color and translucency parameters of tested CAD-CAM ceramic materials were significantly influenced by staining solutions. ZLS group showed significantly least color change than ZR and LD groups. ZLS group showed significantly highest translucency parameter initially (baseline) and after staining procedures than ZR and LD groups while LD group revealed significantly least translucency change than ZR and ZLS groups.
- 1 June 2022
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 127 (6) , 866-874
Effect of different surface treatments on the bond strength of milled polyetheretherketone posts
- 1 June 2022
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 127 (6) , 866-874
Effect of different surface treatments on the bond strength of milled polyetheretherketone posts
- 1 November 2020
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 124 (5) , 565.e1-565.e7
Effect of different fabrication techniques on the marginal precision of polyetheretherketone single-crown copings
- 1 November 2020
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 124 (5) , 565.e1-565.e7
Effect of different fabrication techniques on the marginal precision of polyetheretherketone single-crown copings
- Open Access
- 30 September 2020
- Published by Editora Cubo in Brazilian Dental Science
- Vol. 23 (4) , 9p
Effect of decontamination methods on shear bond strength of resin cement to translucent monolithic zirconia
Objective. The aim of this study was to evaluate the effect of decontamination methods on shear bond strength of resin cement to translucent monolithic zirconia. Material and Methods. Eighty 4-mol yttria-stabilized tetragonal zirconia polycrystal specimens were fabricated. All specimens were subjected to saliva contamination and divided into four groups (n=20) according to the decontamination methods: 70% isopropanol (AL); zirclean (ZC); 5.25% sodium ypochlorite (NaOCL); and no cleaning (NC). All specimens were bonded by using self-adhesive resin cement. Half of the specimens in each group (n=10) were subjected to thermocycling. All specimens were subjected to shear bond strength test in a universal testing machine. Failure modes were evaluated by using a scanning electron microscope (SEM). The data obtained were statistically analyzed by using one-way ANOVA followed by the HSD Tukey test (P < 0.05). Results. ANOVA test revealed a significant difference among the different decontamination methods (P < 0.05). No significant differences were found among NaOCL, ZC, and AL groups as revealed by the HSD Tukey test (P > 0.05). The effect of thermocycling was significantly different in all groups (P < 0.05); whereas, no significant difference was found in group ZC (P > 0.05). (SEM) analysis showed mixed failures in all groups except in group NC where only adhesive failure was observed. Conclusion. Saliva contamination during clinical evaluation significantly decreases the shear bond strength between self-adhesive resin cement and translucent monolithic zirconia. The cleaning gel has an impact on improving the bond strength between resin cement and translucent monolithic zirconia. KEYWORDS Monolithic zirconia; Resin cement; Shear bond strength test; Translucent zirconia; Zirclean.
- 30 September 2020
- Published by Editora Cubo in Brazilian Dental Science
- Vol. 23 (4) , 9p
Open AccessEffect of decontamination methods on shear bond strength of resin cement to translucent monolithic zirconia
Objective. The aim of this study was to evaluate the effect of decontamination methods on shear bond strength of resin cement to translucent monolithic zirconia. Material and Methods. Eighty 4-mol yttria-stabilized tetragonal zirconia polycrystal specimens were fabricated. All specimens were subjected to saliva contamination and divided into four groups (n=20) according to the decontamination methods: 70% isopropanol (AL); zirclean (ZC); 5.25% sodium ypochlorite (NaOCL); and no cleaning (NC). All specimens were bonded by using self-adhesive resin cement. Half of the specimens in each group (n=10) were subjected to thermocycling. All specimens were subjected to shear bond strength test in a universal testing machine. Failure modes were evaluated by using a scanning electron microscope (SEM). The data obtained were statistically analyzed by using one-way ANOVA followed by the HSD Tukey test (P < 0.05). Results. ANOVA test revealed a significant difference among the different decontamination methods (P < 0.05). No significant differences were found among NaOCL, ZC, and AL groups as revealed by the HSD Tukey test (P > 0.05). The effect of thermocycling was significantly different in all groups (P < 0.05); whereas, no significant difference was found in group ZC (P > 0.05). (SEM) analysis showed mixed failures in all groups except in group NC where only adhesive failure was observed. Conclusion. Saliva contamination during clinical evaluation significantly decreases the shear bond strength between self-adhesive resin cement and translucent monolithic zirconia. The cleaning gel has an impact on improving the bond strength between resin cement and translucent monolithic zirconia. KEYWORDS Monolithic zirconia; Resin cement; Shear bond strength test; Translucent zirconia; Zirclean.
- Open Access
- 1 April 2019
- Published by Egyptian Knowledge Bank in Egyptian Dental Journal
- Vol. 65 (2) , 1595-1608
The Clinical performance of all ceramic zirconia-veneered crowns after different surface treatments of zirconia framework: 30 months clinical assessment
Objective: To evaluate the clinical performance of zirconia-veneered crowns after different surface treatment of zirconia frameworks named as; no surface treatment, sandblasting, silicatization (CoJetTM sand) , Selective infiltration etching (SIE) and the novel acids mixture.Materials and methods: A total of 50 patients of age ranged from 20 to 35 years were presented with root canal-treated molar teeth that needed post-retained restorative treatment. They were divided into 5 groups according to surface treatment of zirconia frameworks (10cases each); Group S1: Zirconia frameworks received no surface treatment. Group S2: Zirconia frameworks received sandblasting with 110µm aluminum oxide airborne particle abrasives.GroupS3: Zirconia frameworks received CoJet sand surface treatment. Group S4: Zirconia frameworks received selective infiltration etching surface treatment. Group S5: Zirconia frameworks received a specially formulated mixture of hydrofluoric acid (HF 9 wt%) and nitric acid (HNO3 26 wt%) at a ratio of (4:1) for 5 min. All Zirconia frameworks received IPS e.max Ceram veneering porcelain. They received all ceramic zirconia based single crowns using Cerec in-Lab CAD/CAM technology for designing and milling zirconia frameworks. Teeth preparation was performed to achieve 2mm occlusal clearance, 1.5mm axial reduction and 1mm rounded shoulder subgingival finish line. Secondary impression was taken for each case using addition silicone rubber base impression material and poured using special reflective cerec stone (CAM Base) to facilitate scanning of the preparation using the in-Lab extra oral scanner “inEos”. 3D virtual models were obtained that were used for designing zirconia frameworks. Then, milling of zirconia blocks were performed using inLab Cerec 3 milling machine to obtain zirconia frameworks followed by sintering procedures for the zirconia frameworks. After try in of sintered zirconia frameworks in the patient’s mouth, they received different types of surface treatment. After that, porcelain build up was conducted by layering technique. All ceramic zirconia based crowns were then cemented using dual-cured resin cement (Multilink Auto Mix) and were subjected to a period of 6, 12, 18, 24 and 30 months clinical observation according to the modified USPHS criteria for indirect restorations, where prosthodontic results were recorded. Statistical analysis was performed using a commercially available software program (SPSS 19; SPSS, Chicago, IL, USA). Values were presented as number and percentages. Chi square test was used to compare categorical data.The level of significance was set at P < 0.05. Results: It was found that at 6 months, score A was recorded in all specimens of IPS e.max Ceram, with no statistically significant difference between different surface treatments (p=1). At 12 months, score A was recorded in all specimens, with no statistically significant difference between different surface treatments (p=1). At 18 months, score A was recorded in 100% specimens of CoJet and acid mixture surface treatment, in 90% of specimens of no treatment and in 80% of specimens of sandblasting and SIE; with no statistically significant difference between different surface treatments (p=0.815). At 24 months, score A was recorded in 80% specimens of sandblasting, CoJet and acid mixture surface treatment, in 66.7% of specimens of no treatment and in 22.2% of SIE; with a statistically significant difference between different surface treatments (p=0.045). At 30 months, score A was recorded in 80% specimens of sandblasting, 88.9% CoJet and 77.8% of acid mixture surface treatment, in 44.5% of specimens of no treatment and in 11.1% of SIE; with a statistically significant difference between different surface treatments (p=0.0024). Conclusions: (1) In all cases, the tested systems showed chipping of the comparable low-strength veneering ceramic but no fracture of the high-strength core or the natural tooth in clinical cases. (2) The treatment of the surface zirconia framework with Cojet system was able to maintain acceptable clinical performance at 24 months and 30 months recall periods. However, the other surface treatments showed lesser performance. (3)No direct correlation between zirconia framework surface treatments and long term bonding to veneering ceramic could be addressed; however, it could be multifactorial such as lack of proper framework support, internal defects, direction, magnitude and frequency of the applied load as well as the residual stresses induced by processing.
- 1 April 2019
- Published by Egyptian Knowledge Bank in Egyptian Dental Journal
- Vol. 65 (2) , 1595-1608
Open AccessThe Clinical performance of all ceramic zirconia-veneered crowns after different surface treatments of zirconia framework: 30 months clinical assessment
Objective: To evaluate the clinical performance of zirconia-veneered crowns after different surface treatment of zirconia frameworks named as; no surface treatment, sandblasting, silicatization (CoJetTM sand) , Selective infiltration etching (SIE) and the novel acids mixture.Materials and methods: A total of 50 patients of age ranged from 20 to 35 years were presented with root canal-treated molar teeth that needed post-retained restorative treatment. They were divided into 5 groups according to surface treatment of zirconia frameworks (10cases each); Group S1: Zirconia frameworks received no surface treatment. Group S2: Zirconia frameworks received sandblasting with 110µm aluminum oxide airborne particle abrasives.GroupS3: Zirconia frameworks received CoJet sand surface treatment. Group S4: Zirconia frameworks received selective infiltration etching surface treatment. Group S5: Zirconia frameworks received a specially formulated mixture of hydrofluoric acid (HF 9 wt%) and nitric acid (HNO3 26 wt%) at a ratio of (4:1) for 5 min. All Zirconia frameworks received IPS e.max Ceram veneering porcelain. They received all ceramic zirconia based single crowns using Cerec in-Lab CAD/CAM technology for designing and milling zirconia frameworks. Teeth preparation was performed to achieve 2mm occlusal clearance, 1.5mm axial reduction and 1mm rounded shoulder subgingival finish line. Secondary impression was taken for each case using addition silicone rubber base impression material and poured using special reflective cerec stone (CAM Base) to facilitate scanning of the preparation using the in-Lab extra oral scanner “inEos”. 3D virtual models were obtained that were used for designing zirconia frameworks. Then, milling of zirconia blocks were performed using inLab Cerec 3 milling machine to obtain zirconia frameworks followed by sintering procedures for the zirconia frameworks. After try in of sintered zirconia frameworks in the patient’s mouth, they received different types of surface treatment. After that, porcelain build up was conducted by layering technique. All ceramic zirconia based crowns were then cemented using dual-cured resin cement (Multilink Auto Mix) and were subjected to a period of 6, 12, 18, 24 and 30 months clinical observation according to the modified USPHS criteria for indirect restorations, where prosthodontic results were recorded. Statistical analysis was performed using a commercially available software program (SPSS 19; SPSS, Chicago, IL, USA). Values were presented as number and percentages. Chi square test was used to compare categorical data.The level of significance was set at P < 0.05. Results: It was found that at 6 months, score A was recorded in all specimens of IPS e.max Ceram, with no statistically significant difference between different surface treatments (p=1). At 12 months, score A was recorded in all specimens, with no statistically significant difference between different surface treatments (p=1). At 18 months, score A was recorded in 100% specimens of CoJet and acid mixture surface treatment, in 90% of specimens of no treatment and in 80% of specimens of sandblasting and SIE; with no statistically significant difference between different surface treatments (p=0.815). At 24 months, score A was recorded in 80% specimens of sandblasting, CoJet and acid mixture surface treatment, in 66.7% of specimens of no treatment and in 22.2% of SIE; with a statistically significant difference between different surface treatments (p=0.045). At 30 months, score A was recorded in 80% specimens of sandblasting, 88.9% CoJet and 77.8% of acid mixture surface treatment, in 44.5% of specimens of no treatment and in 11.1% of SIE; with a statistically significant difference between different surface treatments (p=0.0024). Conclusions: (1) In all cases, the tested systems showed chipping of the comparable low-strength veneering ceramic but no fracture of the high-strength core or the natural tooth in clinical cases. (2) The treatment of the surface zirconia framework with Cojet system was able to maintain acceptable clinical performance at 24 months and 30 months recall periods. However, the other surface treatments showed lesser performance. (3)No direct correlation between zirconia framework surface treatments and long term bonding to veneering ceramic could be addressed; however, it could be multifactorial such as lack of proper framework support, internal defects, direction, magnitude and frequency of the applied load as well as the residual stresses induced by processing.