JDJohn D. D'AMore

John D. D'AMore

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


John D. D'AMore has a total of 47 co-authors. Here are the top co-authors by number of shared publications:

  • Adam Wright

    Department of Biomedical Informatics, Vanderbilt University Medical Center, Nashville, Tennessee, USA

    4 shared publications
  • Allison B. McCoy

    Department of Biomedical Informatics, Vanderbilt University Medical Center, Nashville, TN, USA

    2 shared publications
  • Chun Li

    Informatics Department, Diameter Health, Farmington, Connecticut, USA

    2 shared publications
  • Dean F. Sittig

    School of Biomedical Informatics, University of Texas-Memorial Hermann Center for Healthcare Quality and Safety, University of Texas Health Science Center, Houston, Texas, United States

    2 shared publications
  • Ashley Swain

    Lantana Consulting Group, LLC, East Thetford, Vermont, USA

    1 shared publication
  • B. J. Bacskai

    Neurology Service (JDDs'A, STK, MEM, BJB, EAS, BTH), Massachusetts General Hospital, Harvard Medical School, Charlestown, Massachusetts

    1 shared publication

Latest Publications

  • Open Access

    From Pandemic Response to Kill the Clipboard: Patient-Controlled Sharing of Health Data Using International Patient Summary (IPS) and QR codes

    by John D. D'AMore, Estar Rani Vallapu, Lipika Samal, Bryant T. Karras, William B. Lober

    Despite advances in interoperability, patient-supplied medical histories commonly use paper-based forms. Dissatisfaction with this inefficiency has led to the “Kill the Clipboard” initiative from the Centers for Medicare & Medicaid Services to advance digital alternatives. During the coronavirus disease 2019 (COVID-19) pandemic, patient-controlled vaccination record sharing demonstrated that Quick Response (QR) codes and digital data standards provide an effective option. Building on this, several nations are using three standards to securely view and exchange medical data: Fast Healthcare Interoperability Resources, the International Patient Summary, and SMART Health Links. This case report explores the use of QR codes and medical data standards in patient-mediated workflows to share medical histories, describing implementation experiences from four such implementations. We describe standards and developer community experience with global initiatives and implementations across the United States, Canada, and the Hajj pilgrimage, which all support the use of QR codes in patient-mediated data exchange. We report on technical readiness, patient adoption, and reported improvements to emergency preparedness using QR codes to share patient summaries. Advancing patient-mediated exchange with these technologies aligns with initiatives to “Kill the Clipboard.” Preliminary evidence suggests this novel approach can better inform care. These four case studies demonstrate the viability of this approach and the lessons learned from this digital transition.

  • Open Access

    Clinical data sharing improves quality measurement and patient safety

    by John D D’amore, Laura K McCrary, Jody Denson, Chun Li, Christopher J Vitale, Priyaranjan Tokachichu, Dean F Sittig, Allison B McCoy, Adam Wright

    Accurate and robust quality measurement is critical to the future of value-based care. Having incomplete information when calculating quality measures can cause inaccuracies in reported patient outcomes. This research examines how quality calculations vary when using data from an individual electronic health record (EHR) and longitudinal data from a health information exchange (HIE) operating as a multisource registry for quality measurement. Data were sampled from 53 healthcare organizations in 2018. Organizations represented both ambulatory care practices and health systems participating in the state of Kansas HIE. Fourteen ambulatory quality measures for 5300 patients were calculated using the data from an individual EHR source and contrasted to calculations when HIE data were added to locally recorded data. A total of 79% of patients received care at more than 1 facility during the 2018 calendar year. A total of 12 994 applicable quality measure calculations were compared using data from the originating organization vs longitudinal data from the HIE. A total of 15% of all quality measure calculations changed (P < .001) when including HIE data sources, affecting 19% of patients. Changes in quality measure calculations were observed across measures and organizations. These results demonstrate that quality measures calculated using single-site EHR data may be limited by incomplete information. Effective data sharing significantly changes quality calculations, which affect healthcare payments, patient safety, and care quality. Federal, state, and commercial programs that use quality measurement as part of reimbursement could promote more accurate and representative quality measurement through methods that increase clinical data sharing.


    • 5 December 2018
      • Vol. 2018, 358-367

    Interoperability Progress and Remaining Data Quality Barriers of Certified Health Information Technologies.

    by John D'Amore, Omar Bouhaddou, Sandra Mitchell, Chun Li, Russell Leftwich, Todd Turner, Matthew Rahn, Margaret Donahue, Jonathan Nebeker

    The Consolidated Clinical Document Architecture (C-CDA) is the primary standard for clinical document exchange in the United States. While document exchange is prevalent today, prior research has documented challenges to high quality, effective interoperability using this standard. Many electronic health records (EHRs) have recently been certified to a new version of the C-CDA standard as part of federal programs for EHR adoption. This renewed certification generated example documents from 52 health information technologies that have been made publicly available. This research applies automated tooling and manual inspection to evaluate conformance and data quality of these testing artifacts. It catalogs interoperability progress as well as remaining barriers to effective data exchange. Its findings underscore the importance of programs that evaluate data quality beyond schematron conformance to enable the high quality and safe exchange of clinical data.


  • Open Access

    Using Clinical Data Standards to Measure Quality: A New Approach

    by John D. D'Amore, Chun Li, Laura McCrary, Jonathan M. Niloff, Dean F. Sittig, Allison B. McCoy, Adam Wright

    Background Value-based payment for care requires the consistent, objective calculation of care quality. Previous initiatives to calculate ambulatory quality measures have relied on billing data or individual electronic health records (EHRs) to calculate and report performance. New methods for quality measure calculation promoted by federal regulations allow qualified clinical data registries to report quality outcomes based on data aggregated across facilities and EHRs using interoperability standards. Objective This research evaluates the use of clinical document interchange standards as the basis for quality measurement. Methods Using data on 1,100 patients from 11 ambulatory care facilities and 5 different EHRs, challenges to quality measurement are identified and addressed for 17 certified quality measures. Results Iterative solutions were identified for 14 measures that improved patient inclusion and measure calculation accuracy. Findings validate this approach to improving measure accuracy while maintaining measure certification. Conclusion Organizations that report care quality should be aware of how identified issues affect quality measure selection and calculation. Quality measure authors should consider increasing real-world validation and the consistency of measure logic in respect to issues identified in this research.


  • Open Access

    Implementation of a scalable, web-based, automated clinical decision support risk-prediction tool for chronic kidney disease using C-CDA and application programming interfaces

    by Lipika Samal, John D D’aMore, David W Bates, Adam Wright

    Background and Objective: Clinical decision support tools for risk prediction are readily available, but typically require workflow interruptions and manual data entry so are rarely used. Due to new data interoperability standards for electronic health records (EHRs), other options are available. As a clinical case study, we sought to build a scalable, web-based system that would automate calculation of kidney failure risk and display clinical decision support to users in primary care practices. Materials and Methods: We developed a single-page application, web server, database, and application programming interface to calculate and display kidney failure risk. Data were extracted from the EHR using the Consolidated Clinical Document Architecture interoperability standard for Continuity of Care Documents (CCDs). EHR users were presented with a noninterruptive alert on the patient’s summary screen and a hyperlink to details and recommendations provided through a web application. Clinic schedules and CCDs were retrieved using existing application programming interfaces to the EHR, and we provided a clinical decision support hyperlink to the EHR as a service. Results: We debugged a series of terminology and technical issues. The application was validated with data from 255 patients and subsequently deployed to 10 primary care clinics where, over the course of 1 year, 569 533 CCD documents were processed. Conclusions: We validated the use of interoperable documents and open-source components to develop a low-cost tool for automated clinical decision support. Since Consolidated Clinical Document Architecture–based data extraction extends to any certified EHR, this demonstrates a successful modular approach to clinical decision support.


  • Open Access

    Are Meaningful Use Stage 2 certified EHRs ready for interoperability? Findings from the SMART C-CDA Collaborative

    by John D D'AMore, Joshua C Mandel, David A Kreda, Ashley Swain, George A Koromia, Sumesh Sundareswaran, Liora Alschuler, Robert H Dolin, Kenneth D Mandl, Isaac S Kohane, et al.

    Background and objective Upgrades to electronic health record (EHR) systems scheduled to be introduced in the USA in 2014 will advance document intero


  • How the Continuity of Care Document Can Advance Medical Research and Public Health

    by John D. D’amore, Dean F. Sittig, Roberta B. Ness

    Electronic health records in the United States currently isolate digital information in proprietary, institutional databases. Experts have identified inadequate data exchange as a leading challenge to advancements in care quality and efficiency. Recent federal health information technology incentives adopt an extensible standard, called the Continuity of Care Document (CCD), as a new basis for digital interoperability. Although this instrument was designed for individual provider communications, the CCD can be effectively reused for population-based research and public health. Three examples in this commentary demonstrate the potential of CCD aggregation and highlight required changes to existing public health and research practices. Transitioning to the use of this new interoperability standard should be a priority for public health investment, research, and development.


    • 22 October 2011
      • Vol. 2011, 285-94

    The promise of the CCD: challenges and opportunity for quality improvement and population health.

    by John D D'Amore, Dean F Sittig, Adam Wright, M Sriram Iyengar, Roberta B Ness

    Interoperability is a requirement of recent electronic health record (EHR) adoption incentive programs in the United States. One approved structure for clinical data exchange is the continuity of care document (CCD). While primarily designed to promote communication between providers during care transitions, coded data in the CCD can be re-used to aggregate data from different EHRs. This provides an opportunity for provider networks to measure quality and improve population health from a consolidated database. To evaluate such potential, this research collected CCDs from 14 organizations and developed a computer program to parse and aggregate them. In total, 139 CCDs were parsed yielding 680 data in the core content modules of problems, medications, allergies and results. Challenges to interoperability were catalogued and potential quality metrics evaluated based on available content. This research highlights the promise of CCDs for population health and recommends changes for future interoperability standards.


  • Does Telephone Follow-up Predict Patient Satisfaction and Readmission?

    by John D'AMore, John Murray, Helen Powers, Craig Johnson

    Nursing telephone calls after hospital discharge are commonly adopted as a tool to improve patient satisfaction and continuity of care. Previous research, however, has been inconclusive on the impact of telephone follow-up. The purpose of this study was to comparatively examine patients who received telephone follow-up for response differences on a mail satisfaction survey and 30-day readmission rates for a large health system in southeast Texas. Telephone follow-up, patient satisfaction, and administrative billing data from 2008 to 2009 were retrospectively examined across 10 nursing units that routinely performed calls after patient discharge. Patients eligible to receive a nursing call ( N = 10,559) were categorized based on responses to nursing questions or if no contact was made. Logistic regression was used to evaluate whether call data significantly predicted survey response and 30-day readmission rates. Nonparametric analysis was used to evaluate whether survey ratings varied between groups. Completion of telephone follow-up was a significant ( P < 0.01) predictor of patient response to the mail survey, with 62% more patients returning surveys after contact. Completion of a nursing call with a patient who reported a physician appointment was a significant predictor ( P = 0.04) of lower 30-day readmissions. Readmission rates were 10.8% for patients who did not receive telephone follow-up compared to 9.5% for patients who received a call and who had a scheduled physician appointment. Mean nursing and overall satisfaction scores varied minimally between groups and telephone follow-up was not a significant predictor of patient satisfaction. Telephone follow-up shows significant predictive value for mail survey response and 30-day readmission rates but does not correlate with patient satisfaction scores in the hospital setting. ( Population Health Management 2011;14:249–255)


  • Open Access

    In Vivo Multiphoton Imaging of a Transgenic Mouse Model of Alzheimer Disease Reveals Marked Thioflavine-S-Associated Alterations in Neurite Trajectories

    by J. D. D'AMore, S. T. Kajdasz, M. E. McLellan, B. J. Bacskai, E. A. Stern, B. T. Hyman

    Postmortem analyses of senile plaques reveal numerous dystrophic processes in their vicinity. We used in vivo multiphoton microscopy of a transgenic model of Alzheimer disease (AD) to simultaneously image senile plaques and nearby neuronal processes. Plaques were labeled by immunofluorescent staining or thioflavine-S and neuronal processes were labeled with a fluorescent dextran conjugate. Imaging of 3-dimensional volumes in the vicinity of plaques revealed subtle changes in neurite geometry in or near diffuse plaques. By contrast, disruptions in neurite morphology, including dystrophic neurites immediately surrounding plaques as well as major alterations in neurite trajectories, were seen in association with thioflavine-S-positive plaques. Nearly half of all labeled processes that came within 50 μm of a thioflavine-S-positive plaque were altered, suggesting a fairly large “halo” of neuropil alterations that extend beyond the discrete border of a thioflavine-S plaque. These results support the hypothesis that compact thioflavine-S-positive plaques disrupt the neuropil in AD.