David Mills
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
David Mills has a total of 56 co-authors. Here are the top co-authors by number of shared publications:
- Soumya Ghose
GE HealthCare, Niskayuna, NY 12309, USA
3 shared publications - Aaron Dentinger
GE HealthCare Technology & Innovation Center, Niskayuna, NY, 12309, USA
2 shared publications - Guan Xu
University of Michigan
2 shared publications - Janggun Jo
Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI 48109, USA
2 shared publications - Jianwei Qiu
GE HealthCare Technology and Innovation Center, Niskayuna, New York, USA
2 shared publications L. Scott Smith
GE Global Research, Niskayuna, NY 12309, United States
2 shared publications
Latest Publications
- Open Access
- 24 June 2026
- Published by Elsevier in Photoacoustics
- Vol. 50, 100849
An intelligent point-of-care photoacoustic and ultrasound dual-modality imaging system for Rheumatoid arthritis in fingers: Technical development and initial clinical test
- 24 June 2026
- Published by Elsevier in Photoacoustics
- Vol. 50, 100849
Open AccessAn intelligent point-of-care photoacoustic and ultrasound dual-modality imaging system for Rheumatoid arthritis in fingers: Technical development and initial clinical test
- Open Access
- 5 April 2025
- Published by MDPI AG in Bioengineering
- Vol. 12 (4) , 390
SwinDAF3D: Pyramid Swin Transformers with Deep Attentive Features for Automated Finger Joint Segmentation in 3D Ultrasound Images for Rheumatoid Arthritis Assessment
Rheumatoid arthritis (RA) is a chronic autoimmune disease that can cause severe joint damage and functional impairment. Ultrasound imaging has shown promise in providing real-time assessment of synovium inflammation associated with the early stages of RA. Accurate segmentation of the synovium region and quantification of inflammation-specific imaging biomarkers are crucial for assessing and grading RA. However, automatic segmentation of the synovium in 3D ultrasound is challenging due to ambiguous boundaries, variability in synovium shape, and inhomogeneous intensity distribution. In this work, we introduce a novel network architecture, Swin Transformers with Deep Attentive Features for 3D segmentation (SwinDAF3D), which integrates Swin Transformers into a Deep Attentive Features framework. The developed architecture leverages the hierarchical structure and shifted windows of Swin Transformers to capture rich, multi-scale and attentive contextual information, improving the modeling of long-range dependencies and spatial hierarchies in 3D ultrasound images. In a six-fold cross-validation study with 3D ultrasound images of RA patients’ finger joints (n = 72), our SwinDAF3D model achieved the highest performance with a Dice Score (DSC) of 0.838 ± 0.013, an Intersection over Union (IoU) of 0.719 ± 0.019, and Surface Dice Score (SDSC) of 0.852 ± 0.020, compared to 3D UNet (DSC: 0.742 ± 0.025; IoU: 0.589 ± 0.031; SDSC: 0.661 ± 0.029), DAF3D (DSC: 0.813 ± 0.017; IoU: 0.689 ± 0.022; SDSC: 0.817 ± 0.013), Swin UNETR (DSC: 0.808 ± 0.025; IoU: 0.678 ± 0.032; SDSC: 0.822 ± 0.039), UNETR++ (DSC: 0.810 ± 0.014; IoU: 0.684 ± 0.018; SDSC: 0.829 ± 0.027) and TransUNet (DSC: 0.818 ± 0.013; IoU: 0.692 ± 0.017; SDSC: 0.815 ± 0.016) models. This ablation study demonstrates the effectiveness of combining a Swin Transformers feature pyramid with a deep attention mechanism, improving the segmentation accuracy of the synovium in 3D ultrasound. This advancement shows great promise in enabling more efficient and standardized RA screening using ultrasound imaging.
- 5 April 2025
- Published by MDPI AG in Bioengineering
- Vol. 12 (4) , 390
Open AccessSwinDAF3D: Pyramid Swin Transformers with Deep Attentive Features for Automated Finger Joint Segmentation in 3D Ultrasound Images for Rheumatoid Arthritis Assessment
Rheumatoid arthritis (RA) is a chronic autoimmune disease that can cause severe joint damage and functional impairment. Ultrasound imaging has shown promise in providing real-time assessment of synovium inflammation associated with the early stages of RA. Accurate segmentation of the synovium region and quantification of inflammation-specific imaging biomarkers are crucial for assessing and grading RA. However, automatic segmentation of the synovium in 3D ultrasound is challenging due to ambiguous boundaries, variability in synovium shape, and inhomogeneous intensity distribution. In this work, we introduce a novel network architecture, Swin Transformers with Deep Attentive Features for 3D segmentation (SwinDAF3D), which integrates Swin Transformers into a Deep Attentive Features framework. The developed architecture leverages the hierarchical structure and shifted windows of Swin Transformers to capture rich, multi-scale and attentive contextual information, improving the modeling of long-range dependencies and spatial hierarchies in 3D ultrasound images. In a six-fold cross-validation study with 3D ultrasound images of RA patients’ finger joints (n = 72), our SwinDAF3D model achieved the highest performance with a Dice Score (DSC) of 0.838 ± 0.013, an Intersection over Union (IoU) of 0.719 ± 0.019, and Surface Dice Score (SDSC) of 0.852 ± 0.020, compared to 3D UNet (DSC: 0.742 ± 0.025; IoU: 0.589 ± 0.031; SDSC: 0.661 ± 0.029), DAF3D (DSC: 0.813 ± 0.017; IoU: 0.689 ± 0.022; SDSC: 0.817 ± 0.013), Swin UNETR (DSC: 0.808 ± 0.025; IoU: 0.678 ± 0.032; SDSC: 0.822 ± 0.039), UNETR++ (DSC: 0.810 ± 0.014; IoU: 0.684 ± 0.018; SDSC: 0.829 ± 0.027) and TransUNet (DSC: 0.818 ± 0.013; IoU: 0.692 ± 0.017; SDSC: 0.815 ± 0.016) models. This ablation study demonstrates the effectiveness of combining a Swin Transformers feature pyramid with a deep attention mechanism, improving the segmentation accuracy of the synovium in 3D ultrasound. This advancement shows great promise in enabling more efficient and standardized RA screening using ultrasound imaging.
- 1 July 2021
- Published by Elsevier in Physica Medica
- Vol. 88, 104-110
First-in-human imaging using a MR-compatible e4D ultrasound probe for motion management of radiotherapy
- 1 July 2021
- Published by Elsevier in Physica Medica
- Vol. 88, 104-110
First-in-human imaging using a MR-compatible e4D ultrasound probe for motion management of radiotherapy
- 16 March 2020
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11315, 113150J-18
Automatic brain structure-guided registration of pre and intra-operative 3D ultrasound for neurosurgery
Image guidance aids neurosurgeons in making critical clinical decisions of safe maximal resection of diseased tissue. The brain however undergoes significant non-linear structural deformation on account of dura opening and tumor resection. Deformable registration of pre-operative ultrasound to intra-operative ultrasound may be used in mapping of pre-operative planning MRI to intraoperative ultrasound. Such mapping may aid in determining tumor resection margins during surgery. In this work, brain structures visible in pre- and intra-operative 3D ultrasound were used for automatic deformable registration. A Gaussian mixture model was used to automatically segment structures of interest in pre- and intra-operative ultrasound and patch-based normalized cross-correlation was used to establish correspondences between segmented structures. An affine registration based on correspondences was followed by B-spline based deformable registration to register pre- and intra-operative ultrasound. Manually labelled landmarks in pre- and intra-operative ultrasound were used to quantify the mean target registration error. We achieve a mean target registration error of 1.43±0.8 mm when validated with 17 pre- and intra-operative ultrasound image volumes of a public dataset.
- 16 March 2020
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11315, 113150J-18
Automatic brain structure-guided registration of pre and intra-operative 3D ultrasound for neurosurgery
Image guidance aids neurosurgeons in making critical clinical decisions of safe maximal resection of diseased tissue. The brain however undergoes significant non-linear structural deformation on account of dura opening and tumor resection. Deformable registration of pre-operative ultrasound to intra-operative ultrasound may be used in mapping of pre-operative planning MRI to intraoperative ultrasound. Such mapping may aid in determining tumor resection margins during surgery. In this work, brain structures visible in pre- and intra-operative 3D ultrasound were used for automatic deformable registration. A Gaussian mixture model was used to automatically segment structures of interest in pre- and intra-operative ultrasound and patch-based normalized cross-correlation was used to establish correspondences between segmented structures. An affine registration based on correspondences was followed by B-spline based deformable registration to register pre- and intra-operative ultrasound. Manually labelled landmarks in pre- and intra-operative ultrasound were used to quantify the mean target registration error. We achieve a mean target registration error of 1.43±0.8 mm when validated with 17 pre- and intra-operative ultrasound image volumes of a public dataset.
- 1 October 2007
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 122 (4) , 2203-2214
Developing standards for distortion product otoacoustic emission measurements
Characteristics of distortion product otoacoustic emission (DPOAE) measurements were investigated by comparing responses from two different emission measurement systems in 40 volunteers (78 ears) and making test-retest measurements of each system in 20 ears. For transformation of results between systems, it was shown that the minimum data set consisted of input-output (growth) functions obtained by stepping stimulus levels across a wide range, for each set of stimulus frequencies (1-8 kHz). Linear transformations were considered which involved either recalibration of the emission amplitude (vertical transformation) or of the stimulus levels (horizontal transformation). Horizontal transformations provided better agreement between growth functions from the two systems. For frequencies 4-8 kHz, the means of the horizontal shifts required ranged from 8 to 14 dB, clearly exceeding test-retest variability. The optimal horizontal transformation was derived and applied uniformly to all emission measurements; correlations r=0.81-0.89 were found between transformed emission amplitudes. To minimize the necessity for such transformations and to reduce the variability found both within and between systems, development of standardized equipment and methods is suggested for DPOAE measurements, including: (1) an optimized in-ear probe assembly; (2) use of intensity calibration; and (3) a focus on emission "threshold" measurement and analysis.
- 1 October 2007
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 122 (4) , 2203-2214
Developing standards for distortion product otoacoustic emission measurements
Characteristics of distortion product otoacoustic emission (DPOAE) measurements were investigated by comparing responses from two different emission measurement systems in 40 volunteers (78 ears) and making test-retest measurements of each system in 20 ears. For transformation of results between systems, it was shown that the minimum data set consisted of input-output (growth) functions obtained by stepping stimulus levels across a wide range, for each set of stimulus frequencies (1-8 kHz). Linear transformations were considered which involved either recalibration of the emission amplitude (vertical transformation) or of the stimulus levels (horizontal transformation). Horizontal transformations provided better agreement between growth functions from the two systems. For frequencies 4-8 kHz, the means of the horizontal shifts required ranged from 8 to 14 dB, clearly exceeding test-retest variability. The optimal horizontal transformation was derived and applied uniformly to all emission measurements; correlations r=0.81-0.89 were found between transformed emission amplitudes. To minimize the necessity for such transformations and to reduce the variability found both within and between systems, development of standardized equipment and methods is suggested for DPOAE measurements, including: (1) an optimized in-ear probe assembly; (2) use of intensity calibration; and (3) a focus on emission "threshold" measurement and analysis.
- 19 April 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2, 1025-1029
A multirow single crystal phased array for wideband ultrasound imaging
- 19 April 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2, 1025-1029
A multirow single crystal phased array for wideband ultrasound imaging