HGHarinath Garudadri

Harinath Garudadri

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Harinath Garudadri has a total of 73 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A functional test for hearing aids outcomes assessment

    by Harinath Garudadri, Martin Hunt, Aadyanjali Daita, Anusha Yellamsetty, Varsha H. Rallapalli

    We present a functional test for speech understanding called hearing aids (HAs) objective outcomes – HO2 (pronounced as /hɑ:t/) app. It uses natural speech stimuli and generates word level accuracies, phonetic, and broad-phonetic confusion matrices. In the current best practices, hearing loss (HL) is diagnosed using pure tone audiometry (PTA). While PTA is also a functional test, it characterizes only sound detection ability of discrete pure tones, but not overall speech intelligibility due to cochlear impairments leading to sensorineural hearing loss. HO2 app stimuli are based on minimal contrast sets (MCS) of words in a given language. Each word within a subgroup of MCS words differ in a minimal set of (acoustic) phonetic features resulting in a different meaning—phonemics of the given language. The tool includes configuration parameters to include video and closed captions to minimize the role of higher level (cortical) language processes. Researchers can save HO2 app experimental conditions in a configuration file and share with others for repeatability and reproducibility. We present the feasibility of normal and hearing-impaired subjects (mild and moderate HL) to self-administer speech comprehension tests in multiple listening conditions using HO2 app. For the hearing-impaired subjects, results in unaided and aided conditions are presented.

  • Open Access

    Improved Bounds on Neural Complexity for Representing Piecewise Linear Functions

    by Kuan-Lin Chen, Harinath Garudadri, Bhaskar D. Rao

    A deep neural network using rectified linear units represents a continuous piecewise linear (CPWL) function and vice versa. Recent results in the literature estimated that the number of neurons needed to exactly represent any CPWL function grows exponentially with the number of pieces or exponentially in terms of the factorial of the number of distinct linear components. Moreover, such growth is amplified linearly with the input dimension. These existing results seem to indicate that the cost of representing a CPWL function is expensive. In this paper, we propose much tighter bounds and establish a polynomial time algorithm to find a network satisfying these bounds for any given CPWL function. We prove that the number of hidden neurons required to exactly represent any CPWL function is at most a quadratic function of the number of pieces. In contrast to all previous results, this upper bound is invariant to the input dimension. Besides the number of pieces, we also study the number of distinct linear components in CPWL functions. When such a number is also given, we prove that the quadratic complexity turns into bilinear, which implies a lower neural complexity because the number of distinct linear components is always not greater than the minimum number of pieces in a CPWL function. When the number of pieces is unknown, we prove that, in terms of the number of distinct linear components, the neural complexities of any CPWL function are at most polynomial growth for low-dimensional inputs and factorial growth for the worst-case scenario, which are significantly better than existing results in the literature.

  • Unsupervised Sequence Alignment between Video and Human Center of Pressure

    by Shiwei Jin, Minh Vo, Chen Du, Harinath Garudadri, Allison Py, David J. Moore, Kristine M. Erlandson, Raeanne C. Moore, Truong Nguyen

    Center of pressure (COP) estimation with images/videos as input achieves accurate precision with the development of the human skeleton joint extraction tasks. As a supervised learning task, correct labels acquired from COP with regard to the input images/videos are significant. Thus, synchronization between these two different types of sequences is necessary. If these two different modalities are misaligned, the downstream tasks’ precision is affected significantly due to the inaccurate labels from the COP sequence. In this paper, we used a synchronized dataset and unsupervised deep learning to train an Alignment Network to align video and COP sequences on another unsynchronized dataset where each sequence starts at a different time and has different frame rates. On the synchronized dataset, the Alignment Network removes 84.4% of temporal offset. On the unsynchronized dataset, we proposed a simple yet effective Differential Network to simulate one practical downstream task. We used the differential Network to estimate the sway level of COP. Results show that this method achieved significant improvement (over 20% improvement on three sway level cases) over the misaligned dataset.

  • Open Access

    Artifacts Mitigation in Sensors for Spasticity Assessment

    by Çağrı Yalçın, Mathew Sam, Yifeng Bu, Moran Amit, Andrew J. Skalsky, Michael Yip, Tse Nga Ng, Harinath Garudadri

    Spasticity is a pathological condition that can occur in people with neuromuscular disorders. Objective, repeatable metrics are needed for evaluation to provide appropriate treatment and to monitor patient condition. Herein, an instrumented bimodal glove with force and movement sensors for spasticity assessment is presented. To mitigate noise artifacts, machine learning techniques are used, specifically a multitask neural network, to calibrate the instrumented glove signals against the ground truth from sensors integrated in a robotic arm. The motorized robotic arm system offers adjustable resistance to simulate different levels of muscle stiffness in spasticity, and the sensors on the robot provide ground‐truth measurements of angular displacement and force applied during flexion and extension maneuvers. The robotic sensor measurements are used to train the instrumented glove data through multitask learning. After processing through the neural network, the Pearson correlation coefficients between the processed signals and the ground truth are above 0.92, demonstrating successful signal calibration and noise mitigation.


  • Improved Gait Speed Calculation via Modulation Spectral Analysis of Noisy Accelerometer Data

    by Diana P. Tobon V., Harinath Garudadri, Job G. Godino, Suneeta Godbole, Kevin Patrick, Tiago H. Falk

    Chronic diseases among older adults carry a heavy burden on a country's healthcare system and economy. As such, there is a critical need for the development of cost-effective, technology-based tools that can be scaled to meet the needs of older adults. Gait speed, for example, is an important predictor of change in functional status and health outcomes in older adults. There is no universally accepted method for measuring gait speed in clinical practice and research, and differences in methods may influence the observed associations between gait speed and health. Moreover, existing methods are sensitive to artifacts, which are present in burgeoning low-cost wearable devices. To overcome this limitation, this paper proposes an artifact-robust gait speed calculation method using spectro-temporal signal processing of accelerometer data. To this end, a new so-called modulation domain gait speed (MD-GS) metric is proposed and tested on data collected from forty older adults performing a 400-meter walk test with a sensor placed on a waist-worn belt. Average gait speed calculation is performed for each participant. Experimental results showed the proposed method achieved very high correlation (ρ = 0.98) with ground truth gait speeds, as well as low errors and error variability (0.05± 0.14) m/s, thus substantially outperforming gait speed calculation using a well-known kinematic model. The increased robustness against artifacts, make it a promising solution for aging-in-home applications based on low-cost wearable devices.


  • Flexible Pressure Sensors for Objective Assessment of Motor Disorders

    by Moran Amit, Leanne Chukoskie, Andrew J. Skalsky, Harinath Garudadri, Tse Nga Ng

    Monitoring body motion is relevant to motor control disorders as well as assessment of fine motor skills in child development. Furthermore, motion tracking is necessary for rehabilitation monitoring and injury prevention and benefits both sick and healthy individuals. Flexible pressure sensors based on resistors, capacitors, inductors, or transistors are reviewed in the context of healthcare measurements, ranging from physiological signals to body movement characteristics such as grip and gait. To demonstrate the use of flexible pressure sensors for motor assessment, a touch sensing glove that evaluates fine motor skills in autism research is developed. The results show that autistic children perform fewer taps per minute compared to typically developing children, with larger variations in tap durations. In a second example, a force and motion sensing glove is developed to assess spasticity, a neuromuscular disorder that causes muscle stiffness/resistance and jerky movement. Analyses of force versus velocity show movement‐dependent muscle resistance in a patient with spasticity. Through these flexible sensor systems, the shift from subjective scores to objective measurement will promote better diagnosis and dramatically improve the accuracy in tracking patient response to therapy.


  • Open Access

    A Wearable, Extensible, Open-Source Platform for Hearing Healthcare Research

    by Louis Pisha, Julian Warchall, Tamara Zubatiy, Sean Hamilton, Ching-Hua Lee, Ganz Chockalingam, Patrick P. Mercier, Rajesh Gupta, Bhaskar D. Rao, Harinath Garudadri

    Hearing loss is one of the most common conditions affecting older adults worldwide. Frequent complaints from the users of modern hearing aids include poor speech intelligibility in noisy environments and high cost, among other issues. However, the signal processing and audiological research needed to address these problems has long been hampered by proprietary development systems, underpowered embedded processors, and the difficulty of performing tests in real-world acoustical environments. To facilitate existing research in hearing healthcare and enable new investigations beyond what is currently possible, we have developed a modern, open-source hearing research platform, Open Speech Platform (OSP). This paper presents the system design of the complete OSP wearable platform, from hardware through firmware and software to user applications. The platform provides a complete suite of basic and advanced hearing aid features which can be adapted by researchers. It serves web apps directly from a hotspot on the wearable hardware, enabling users and researchers to control the system in real time. In addition, it can simultaneously acquire high-quality electroencephalography (EEG) or other electrophysiological signals closely synchronized to the audio. All of these features are provided in a wearable form factor with enough battery life for hours of operation in the field.


  • Robust Biopotential Acquisition via a Distributed Multi-Channel FM-ADC

    by Julian Warchall, Paul Theilmann, Yuxuan Ouyang, Harinath Garudadri, Patrick P. Mercier

    This contribution presents an active electrode system for biopotential acquisition using a distributed multi-channel FM-modulated analog front-end and ADC architecture. Each electrode captures one biopotential signal and converts to a frequency modulated signal using a VCO tuned to a unique frequency. Each electrode then buffers its output onto a shared analog line that aggregates all of the FM-modulated channels. This aggregation results in rugged, wearable form factor by eliminating wire clutter of traditional systems. A gateway integrated circuit then digitizes the composite FM signal and transmits for further processing. The coding gain due to bandwidth expansion of FM provides a large usable dynamic range (DR) and the single ADC for multiple channels results in significant power savings. Finally, the use of FM signals between the transducers and ADC provides resilience to motion and EMI artifacts. The system is implemented in 65 nm silicon using two distinct 1 mm square chip designs. Six-channel operation is demonstrated using FM channels with center frequencies around 15 MHz and the system achieves a usable DR of over 100 dB, while achieving figure of merit competitive with state of the art prior works using traditional approaches.


  • 22.2 A Rugged Wearable Modular ExG Platform Employing a Distributed Scalable Multi-Channel FM-ADC Achieving 101dB Input Dynamic Range and Motion-Artifact Resilience

    by Julian Warchall, Paul Theilmann, Yuxuan Ouyang, Harinath Garudadri, Patrick P. Mercier

    Wearable ExG biopotential acquisition systems can potentially capture a wealth of clinically useful diagnostic information during activities of daily life. In practice, however, motions from common activities introduce large artifacts that can easily saturate traditional analog front-ends (AFEs) designed to sense biopotentials on the micro- to milli-volt scale. In addition, the wires that connect each electrode to an array of high-impedance AFEs can easily pick up interference and large, potentially saturating artifacts. For these reasons, many-channel monolithic biopotential sensing systems are often fragile and difficult to use in ambulatory environments. While active electrodes can be used to combat interference picked up by high-impedance wires, they require power-hungry drivers to deliver high-fidelity signals across relevant anatomy to an array of ADCs. Placing an ADC on each active electrode followed by a digital bus driver can eliminate analog driver power, resulting in a per-channel power consumption of 104μW in [1]. However, the 12b SAR ADC in [1] could not tolerate significant motion artifacts, and further increasing the ADC resolution to accommodate a larger dynamic range (DR) would require a quadratic increase in per-channel ADC power consumption.


  • A printed wireless fluidic pressure sensor

    by Yichen Zhai, Jiyeon Lee, Quyen Hoang, Dan Sievenpipper, Harinath Garudadri, Tse Nga Ng

    An inkjet-printed inductor–capacitor (LC) resonator is demonstrated for wireless monitoring of pressure in aqueous environments. The sensing mechanism is based on a compressible capacitor that modulates the LC circuit resonant frequency depending on the applied pressure. The trace conductivity and geometric designs of inductors are improved to increase mutual inductive coupling between the sensor and the readout coil. The dielectric porosity in the capacitive sensors are tuned to enhance pressure sensitivity. The encapsulated sensor showed a linear response to pressure between 30 and 170 mmHg (4–23 kPa) with respect to atmospheric pressure and a resolution of 3 mmHg. The sensor temporal response is up to 6 Hz and capable of capturing typical heart-pulse waveforms as a proof-of-concept demonstration.