Rigoberto Vazquez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Rigoberto Vazquez has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Aleksey Gokadze
Kings Eye Medical Care PC, New York, NY
1 shared publication - Alexander Movshovich
Weill Cornell Medicine, New York, NY
1 shared publication - Andres Barrado
Power Electronics Systems Group, Carlos III University of Madrid, 28911 Leganes, Spain
1 shared publication - Antonio Lazaro
Power Electronics Systems Group, Universidad Carlos III de Madrid, Legans, Spain
1 shared publication - Ariella Shikanov
Department of Obstetrics and Gynecology, University of Michigan, United States
1 shared publication - Brian James Love
Department of Materials Science and Engineering, University of Michigan, Ann Arbor, MI 48109, USA
1 shared publication
Latest Publications
- 31 July 2026
- Published by Wolters Kluwer Health in Cornea
- Vol. 45 (11) , 1427-1431
MRI Safety of Iron Oxide–Containing Pigments in Keratopigmentation
Purpose: To evaluate the magnetic resonance imaging (MRI) safety of iron oxide–containing pigments previously used in femtosecond laser–assisted keratopigmentation (KTP). Methods: Twelve pigment formulations were initially screened using MRI to identify the most magnetically reactive sample. Standardized pigment amounts equivalent to clinical use were measured with a precision microbalance. Temperature changes were monitored with fiber optic thermometry in porcine corneas with and without pigment after femtosecond laser tunnel creation during a standard MRI protocol. Pigment motility was assessed by suspending impregnated filter paper in MRI-safe glass jars and observing potential movement within the bore. MRI sequences were analyzed for image distortion. Results: No measurable temperature increase was observed in pigment-containing or control porcine corneas during MRI exposure. No pigment movement was detected; the impregnated filter paper remained stable without displacement, deflection, or torque. MRI revealed a localized signal at the pigment site, causing mild distortion limited to the corneal region, with no interference in adjacent or posterior ocular structures. Conclusions: Iron oxide–containing pigments (Biotic Phocea, France) used in KTP did not cause heating, motility, or clinically significant imaging artifacts during MRI. Although localized corneal signal distortion was noted, it did not hinder the visualization of deeper eye tissues. These findings support the safety of MRI in patients with prior KTP using iron oxide pigments, including those who had initial pigments implanted.
- 31 July 2026
- Published by Wolters Kluwer Health in Cornea
- Vol. 45 (11) , 1427-1431
MRI Safety of Iron Oxide–Containing Pigments in Keratopigmentation
Purpose: To evaluate the magnetic resonance imaging (MRI) safety of iron oxide–containing pigments previously used in femtosecond laser–assisted keratopigmentation (KTP). Methods: Twelve pigment formulations were initially screened using MRI to identify the most magnetically reactive sample. Standardized pigment amounts equivalent to clinical use were measured with a precision microbalance. Temperature changes were monitored with fiber optic thermometry in porcine corneas with and without pigment after femtosecond laser tunnel creation during a standard MRI protocol. Pigment motility was assessed by suspending impregnated filter paper in MRI-safe glass jars and observing potential movement within the bore. MRI sequences were analyzed for image distortion. Results: No measurable temperature increase was observed in pigment-containing or control porcine corneas during MRI exposure. No pigment movement was detected; the impregnated filter paper remained stable without displacement, deflection, or torque. MRI revealed a localized signal at the pigment site, causing mild distortion limited to the corneal region, with no interference in adjacent or posterior ocular structures. Conclusions: Iron oxide–containing pigments (Biotic Phocea, France) used in KTP did not cause heating, motility, or clinically significant imaging artifacts during MRI. Although localized corneal signal distortion was noted, it did not hinder the visualization of deeper eye tissues. These findings support the safety of MRI in patients with prior KTP using iron oxide pigments, including those who had initial pigments implanted.
- Open Access
Stretchable Sensor Materials Applicable to Radiofrequency Coil Design in Magnetic Resonance Imaging: A Review
Wearable sensors are rapidly gaining influence in the diagnostics, monitoring, and treatment of disease, thereby improving patient outcomes. In this review, we aim to explore how these advances can be applied to magnetic resonance imaging (MRI). We begin by (i) introducing limitations in current flexible/stretchable RF coils and then move to the broader field of flexible sensor technology to identify translatable technologies. To this goal, we discuss (ii) emerging materials currently used for sensor substrates, (iii) stretchable conductive materials, (iv) pairing and matching of conductors with substrates, and (v) implementation of lumped elements such as capacitors. Applicable (vi) fabrication methods are presented, and the review concludes with a brief commentary on (vii) the implementation of the discussed sensor technologies in MRI coil applications. The main takeaway of our research is that a large body of work has led to exciting new sensor innovations allowing for stretchable wearables, but further exploration of materials and manufacturing techniques remains necessary, especially when applied to MRI diagnostics.
Open AccessStretchable Sensor Materials Applicable to Radiofrequency Coil Design in Magnetic Resonance Imaging: A Review
Wearable sensors are rapidly gaining influence in the diagnostics, monitoring, and treatment of disease, thereby improving patient outcomes. In this review, we aim to explore how these advances can be applied to magnetic resonance imaging (MRI). We begin by (i) introducing limitations in current flexible/stretchable RF coils and then move to the broader field of flexible sensor technology to identify translatable technologies. To this goal, we discuss (ii) emerging materials currently used for sensor substrates, (iii) stretchable conductive materials, (iv) pairing and matching of conductors with substrates, and (v) implementation of lumped elements such as capacitors. Applicable (vi) fabrication methods are presented, and the review concludes with a brief commentary on (vii) the implementation of the discussed sensor technologies in MRI coil applications. The main takeaway of our research is that a large body of work has led to exciting new sensor innovations allowing for stretchable wearables, but further exploration of materials and manufacturing techniques remains necessary, especially when applied to MRI diagnostics.
- Open Access
- 1 July 2021
- Published by Wiley in Health Science Reports
- Vol. 4 (3) , e318
Re‐evaluating expanding intravenous catheters in medical practice
Background: Intravenous catheters are common and essential devices within medical practice. Their placement can be difficult, leading to application of several technologies to improve success. Functionally expanding catheters were once an exciting technology, derailed clinically by hypersensitivity reactions. The exact cause of reactions, attributed to Aquavene catheter materials, remains unknown.Aims: To reinvestigate functionally expanding intravenous catheters.Materials and Methods: The history of the functionally expanding intravenous catheter is presented here along with its utility in current medical practice, potential for further investigation, and possible redesign of these once promising devices.Results: This review demonstrates clinical utility and a lack of definitive cause for failure of the previous functionally expanding intravenous catheter design. As Aquavene materials themselves are commonly considered the cause of hypersensitivity reactions which removed expanding intravenous catheters from the market, this review found several possible substitutes for this material for use in any redesign.Discussion and Conclusion: The functionally expanding intravenous catheter failed due to hypersensitivity reactions in patients. Alternative materials exist for a possible redesign on this once promising clinical product.
- 1 July 2021
- Published by Wiley in Health Science Reports
- Vol. 4 (3) , e318
Open AccessRe‐evaluating expanding intravenous catheters in medical practice
Background: Intravenous catheters are common and essential devices within medical practice. Their placement can be difficult, leading to application of several technologies to improve success. Functionally expanding catheters were once an exciting technology, derailed clinically by hypersensitivity reactions. The exact cause of reactions, attributed to Aquavene catheter materials, remains unknown.Aims: To reinvestigate functionally expanding intravenous catheters.Materials and Methods: The history of the functionally expanding intravenous catheter is presented here along with its utility in current medical practice, potential for further investigation, and possible redesign of these once promising devices.Results: This review demonstrates clinical utility and a lack of definitive cause for failure of the previous functionally expanding intravenous catheter design. As Aquavene materials themselves are commonly considered the cause of hypersensitivity reactions which removed expanding intravenous catheters from the market, this review found several possible substitutes for this material for use in any redesign.Discussion and Conclusion: The functionally expanding intravenous catheter failed due to hypersensitivity reactions in patients. Alternative materials exist for a possible redesign on this once promising clinical product.
- 23 December 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 58 (9) , 3976-3987
Modulation Technique for Low Frequency Harmonic Cancellation in Auxiliary Railway Power Supplies
The auxiliary railway power supply (ARPS) is needed in order to provide low and medium voltages to the onboard systems from the catenary high voltage. The outputs of the ARPS can be dc (24 V dc ÷100 V dc ) or ac (400 V ac ). In the case of ac voltage generation, the ac output voltage is under very restrictive total harmonic distortion specifications even in the presence of nonlinear loads which draw low-frequency current harmonics. Along the present paper, a new modulation technique is proposed under the name of harmonic cancellation technique. It is based on the proper pre-distortion of the inverter output voltage in order to generate a controlled fundamental harmonic as well as a set of low-frequency harmonics which cancel out the harmonic pollution due to the nonlinear load performance. The theoretical background needed to implement the modulation technique is provided as well as the experimental validation of the proposed modulation technique through a scale-down prototype.
- 23 December 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 58 (9) , 3976-3987
Modulation Technique for Low Frequency Harmonic Cancellation in Auxiliary Railway Power Supplies
The auxiliary railway power supply (ARPS) is needed in order to provide low and medium voltages to the onboard systems from the catenary high voltage. The outputs of the ARPS can be dc (24 V dc ÷100 V dc ) or ac (400 V ac ). In the case of ac voltage generation, the ac output voltage is under very restrictive total harmonic distortion specifications even in the presence of nonlinear loads which draw low-frequency current harmonics. Along the present paper, a new modulation technique is proposed under the name of harmonic cancellation technique. It is based on the proper pre-distortion of the inverter output voltage in order to generate a controlled fundamental harmonic as well as a set of low-frequency harmonics which cancel out the harmonic pollution due to the nonlinear load performance. The theoretical background needed to implement the modulation technique is provided as well as the experimental validation of the proposed modulation technique through a scale-down prototype.