Letian Huang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Letian Huang has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Qian Wang
National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei 230029, China
3 shared publications - Liuxu Zong
Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, China
2 shared publications - Qing Luo
School of Nuclear Science and Technology, University of Science and Technology of China, Hefei, CHINA
2 shared publications Baogen Sun
National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei 230026, China
1 shared publication- Baogen Sun
National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei, China
1 shared publication Chuhan Wang
National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei, China
1 shared publication
Latest Publications
- 1 July 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (7)
Cavity-based non-destructive diagnostics of beam quadrupole moment and energy spread.
A non-destructive diagnostic system based on the TM220 mode of a rectangular cavity has been developed for beam quadrupole moment measurements, and its application to indirect beam energy spread diagnostics is demonstrated for the first time. By installing the cavity downstream of a bending magnet, variations in beam energy spread lead to changes in the transverse beam distribution and the quadrupole moment, which can be measured via the TM220 mode. Motivated by the requirements of high-repetition-rate superconducting free-electron laser facilities and high-charge, high-current linear accelerators (linacs), where screen-based diagnostics become impractical, the cavity-based approach offers a narrowband response and a significantly improved signal-to-noise ratio compared with a conventional eight strip line monitor (ESM). The cavity design, fabrication, and radio frequency (RF) characterization are described, along with the electronics architecture and the implementation of online tests. Beam experiments demonstrated the capability of monitoring quadrupole moment and energy spread. For the cavity monitor, a quadrupole moment measurement uncertainty of 0.034 mm2 was achieved at 350 pC. Based on the measured quadrupole moment uncertainty and machine optics parameters of the present experiment, an energy spread resolution better than 10-5 is estimated, significantly outperforming the ESM under identical conditions. Furthermore, by correlating the cavity-based measurements with the RF accelerating phase, the feasibility of using the cavity for phase feedback was demonstrated. The observed phase dependence indicates the potential for high-resolution RF phase monitoring and feedback under practical operating conditions.
- 1 July 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (7)
Cavity-based non-destructive diagnostics of beam quadrupole moment and energy spread.
A non-destructive diagnostic system based on the TM220 mode of a rectangular cavity has been developed for beam quadrupole moment measurements, and its application to indirect beam energy spread diagnostics is demonstrated for the first time. By installing the cavity downstream of a bending magnet, variations in beam energy spread lead to changes in the transverse beam distribution and the quadrupole moment, which can be measured via the TM220 mode. Motivated by the requirements of high-repetition-rate superconducting free-electron laser facilities and high-charge, high-current linear accelerators (linacs), where screen-based diagnostics become impractical, the cavity-based approach offers a narrowband response and a significantly improved signal-to-noise ratio compared with a conventional eight strip line monitor (ESM). The cavity design, fabrication, and radio frequency (RF) characterization are described, along with the electronics architecture and the implementation of online tests. Beam experiments demonstrated the capability of monitoring quadrupole moment and energy spread. For the cavity monitor, a quadrupole moment measurement uncertainty of 0.034 mm2 was achieved at 350 pC. Based on the measured quadrupole moment uncertainty and machine optics parameters of the present experiment, an energy spread resolution better than 10-5 is estimated, significantly outperforming the ESM under identical conditions. Furthermore, by correlating the cavity-based measurements with the RF accelerating phase, the feasibility of using the cavity for phase feedback was demonstrated. The observed phase dependence indicates the potential for high-resolution RF phase monitoring and feedback under practical operating conditions.
- Open Access
- 1 April 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (04) , P04004
A study of baseline correction of ICT signals using a Whittaker smoothing-based method for accelerator bunch charge measurements
The integrating current transformer (ICT) is widely used for non-interceptive charge measurements of ultra-short bunches in particle accelerators. However, in practical operation, ICT output signals are susceptible to electromagnetic interference, which introduces baseline drift and low-frequency fluctuations, thereby increasing the charge measurement error and degrading the measurement resolution. A baseline correction method based on Whittaker smoothing (WS) is developed. By employing a regularized least-squares model with a second-order difference penalty, the method adaptively reconstructs the baseline without assuming any predefined functional form. Analysis of measured ICT baseline signals shows that the WS-based method reduces the baseline reconstruction error by approximately 70% and exhibits more stable performance across varying baseline shapes compared with conventional polynomial fitting. Offline tests and beam experiments further demonstrate that WS-based correction significantly reduces charge measurement error, improves measurement resolution, and preserves good linearity. The proposed method provides an effective and practically applicable solution for ICT-based charge diagnostics under interference conditions.
- 1 April 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (04) , P04004
Open AccessA study of baseline correction of ICT signals using a Whittaker smoothing-based method for accelerator bunch charge measurements
The integrating current transformer (ICT) is widely used for non-interceptive charge measurements of ultra-short bunches in particle accelerators. However, in practical operation, ICT output signals are susceptible to electromagnetic interference, which introduces baseline drift and low-frequency fluctuations, thereby increasing the charge measurement error and degrading the measurement resolution. A baseline correction method based on Whittaker smoothing (WS) is developed. By employing a regularized least-squares model with a second-order difference penalty, the method adaptively reconstructs the baseline without assuming any predefined functional form. Analysis of measured ICT baseline signals shows that the WS-based method reduces the baseline reconstruction error by approximately 70% and exhibits more stable performance across varying baseline shapes compared with conventional polynomial fitting. Offline tests and beam experiments further demonstrate that WS-based correction significantly reduces charge measurement error, improves measurement resolution, and preserves good linearity. The proposed method provides an effective and practically applicable solution for ICT-based charge diagnostics under interference conditions.
- 30 October 2024
- Published by World Scientific Pub Co Pte Ltd in Modern Physics Letters A
- Vol. 39 (40)
Cavity-based bunch length measurement study for the Super Tau-Charm Facility transport line
In this paper, a nondestructive cavity-based scheme is proposed to achieve high-resolution bunch length measurement in the Super Tau-Charm Facility (STCF) transport line. By extracting the TM010 and TM020 mode signals excited by the beam within a single pillbox cavity, a beam spectrum can be obtained to deduce the Root-Mean-Square (RMS) bunch length. This scheme is more spatially compact compared to the traditional method using double cavities. In this study, the basic principles of the cavity-based bunch length measurement method are explained, the monitor layout is introduced, and the design methods for the cavity and electronics are described. A prototype cavity was machined. Offline tests demonstrate that the eigenmodes in the cavity meet the design requirements and can be used for the bunch length measurements. Based on the online signal characteristics of the Cavity Beam Position Monitors (CBPMs) and the beam parameters of the STCF, the performance of this measurement method is evaluated. For picosecond-level bunches in the STCF transport line, this scheme can provide a bunch length measurement resolution of 233.5 fs at 1.5 nC.
- 30 October 2024
- Published by World Scientific Pub Co Pte Ltd in Modern Physics Letters A
- Vol. 39 (40)
Cavity-based bunch length measurement study for the Super Tau-Charm Facility transport line
In this paper, a nondestructive cavity-based scheme is proposed to achieve high-resolution bunch length measurement in the Super Tau-Charm Facility (STCF) transport line. By extracting the TM010 and TM020 mode signals excited by the beam within a single pillbox cavity, a beam spectrum can be obtained to deduce the Root-Mean-Square (RMS) bunch length. This scheme is more spatially compact compared to the traditional method using double cavities. In this study, the basic principles of the cavity-based bunch length measurement method are explained, the monitor layout is introduced, and the design methods for the cavity and electronics are described. A prototype cavity was machined. Offline tests demonstrate that the eigenmodes in the cavity meet the design requirements and can be used for the bunch length measurements. Based on the online signal characteristics of the Cavity Beam Position Monitors (CBPMs) and the beam parameters of the STCF, the performance of this measurement method is evaluated. For picosecond-level bunches in the STCF transport line, this scheme can provide a bunch length measurement resolution of 233.5 fs at 1.5 nC.
- 2 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 68 (8) , 2239-2248
Development of a High-Resolution Digital Beam Position Processor for the Hefei Advanced Light Facility Preresearch Project
A digital beam position processor (DBPP) with high resolution is required and developed for the Hefei Advanced Light Facility Preresearch Project to measure the orbit information and control the beam orbit jitter within one-tenth of the beam size. In this article, the design of the developed processor is presented in detail. Special attention is given to the analog part of the processor for a small noise figure and the calibration method for acceptable long-term stability. Different from the traditional calibration method using only the quasi-crossbar switch, our method combines temperature compensation attenuators, static digital attenuators, and the quasi-crossbar switch to a compound dynamic calibration method. In addition, a design of a switchable amplification stage is adopted to reduce the noise figure. A test stand, specially designed for the calibration and tests of the processor, is described. The initial laboratory tests show that the DBPP has a resolution of ~500 nm for turn-by-turn position, ~90 nm for fast acquisition at 5.03 kS/s rate, and ~30 nm for slow acquisition at 9.83-S/s rate, at a simulated beam current of about 500 mA. The alternative tests of the processor at Hefei light source-II verify the performance.
- 2 July 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 68 (8) , 2239-2248
Development of a High-Resolution Digital Beam Position Processor for the Hefei Advanced Light Facility Preresearch Project
A digital beam position processor (DBPP) with high resolution is required and developed for the Hefei Advanced Light Facility Preresearch Project to measure the orbit information and control the beam orbit jitter within one-tenth of the beam size. In this article, the design of the developed processor is presented in detail. Special attention is given to the analog part of the processor for a small noise figure and the calibration method for acceptable long-term stability. Different from the traditional calibration method using only the quasi-crossbar switch, our method combines temperature compensation attenuators, static digital attenuators, and the quasi-crossbar switch to a compound dynamic calibration method. In addition, a design of a switchable amplification stage is adopted to reduce the noise figure. A test stand, specially designed for the calibration and tests of the processor, is described. The initial laboratory tests show that the DBPP has a resolution of ~500 nm for turn-by-turn position, ~90 nm for fast acquisition at 5.03 kS/s rate, and ~30 nm for slow acquisition at 9.83-S/s rate, at a simulated beam current of about 500 mA. The alternative tests of the processor at Hefei light source-II verify the performance.