SHSascha Heinemann

Sascha Heinemann

*This is an algorithmically generated author record based on publicly available information.

Sascha Heinemann has a total of 42 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Investigation of the Adhesion Behavior of Calcium Phosphate Cement Depending on Geometric Parameters

    by Martin Pendzik, Bassem Moughnieh, Philipp Sembdner, Stefan Holtzhausen, Sascha Heinemann, Kristin Paetzold-Byhain

  • Open Access

    Poly(dl-lactide) Polymer Blended with Mineral Phases for Extrusion 3D Printing—Studies on Degradation and Biocompatibility

    by Corina Vater, Christian Bräuer, Stefanie Grom, Tatjana Fecht, Tilman Ahlfeld, Max von Witzleben, Anna-Maria Placht, Kathleen Schütz, Jan Marc Schehl, Tobias Wolfram, et al.

    A promising therapeutic option for the treatment of critical-size mandibular defects is the implantation of biodegradable, porous structures that are produced patient-specifically by using additive manufacturing techniques. In this work, degradable poly(DL-lactide) polymer (PDLLA) was blended with different mineral phases with the aim of buffering its acidic degradation products, which can cause inflammation and stimulate bone regeneration. Microparticles of CaCO3, SrCO3, tricalcium phosphates (α-TCP, β-TCP), or strontium-modified hydroxyapatite (SrHAp) were mixed with the polymer powder following processing the blends into scaffolds with the Arburg Plastic Freeforming 3D-printing method. An in vitro degradation study over 24 weeks revealed a buffer effect for all mineral phases, with the buffering capacity of CaCO3 and SrCO3 being the highest. Analysis of conductivity, swelling, microstructure, viscosity, and glass transition temperature evidenced that the mineral phases influence the degradation behavior of the scaffolds. Cytocompatibility of all polymer blends was proven in cell experiments with SaOS-2 cells. Patient-specific implants consisting of PDLLA + CaCO3, which were tested in a pilot in vivo study in a segmental mandibular defect in minipigs, exhibited strong swelling. Based on these results, an in vitro swelling prediction model was developed that simulates the conditions of anisotropic swelling after implantation.


  • Open Access

    Confirmation of Calcium Phosphate Cement Biodegradation after Jawbone Augmentation around Dental Implants Using Three-Dimensional Visualization and Segmentation Software

    by Qusai Alkhasawnah, Sera Elmas, Keywan Sohrabi, Sameh Attia, Sascha Heinemann, Thaqif El Khassawna, Christian Heiss

    The use of autologous bone graft for oral rehabilitation of bone atrophy is considered the gold standard. However, the available grafts do not allow a fast loading of dental implants, as they require a long healing time before full functionality. Innovative bioactive materials provide an easy-to-use solution to this problem. The current study shows the feasibility of calcium phosphate cement paste (Paste-CPC) in the sinus. Long implants were placed simultaneously with the cement paste, and provisional prosthetics were also mounted in the same sessions. Final prosthetics and the full loading took place within the same week. Furthermore, the study shows for the first time the possibility to monitor not only healing progression using Cone Beam Computer tomography (CBCT) but also material retention, over two years, on a case study example. The segmented images showed a 30% reduction of the cement size and an increased mineralized tissue in the sinus. Mechanical testing was performed qualitatively using reverse torque after insertion and cement solidification to indicate clinical feasibility. Both functional and esthetic satisfaction remain unchanged after one year. This flowable paste encourages the augmentation procedure with less invasive measure through socket of removed implants. However, this limitation can be addressed in future studies.


  • Open Access

    Performance of Calcium Phosphate Cements in the Augmentation of Sheep Vertebrae—An Ex Vivo Study

    by Raimund W. Kinne, Francesca Gunnella, Elke Kunisch, Sascha Heinemann, Berthold Nies, Stefan Maenz, Victoria Horbert, Bernhard Illerhaus, René Huber, Izabela Firkowska-Boden, et al.

    Oil-based calcium phosphate cement (Paste-CPC) shows not only prolonged shelf life and injection times, but also improved cohesion and reproducibility during application, while retaining the advantages of fast setting, mechanical strength, and biocompatibility. In addition, poly(L-lactide-co-glycolide) (PLGA) fiber reinforcement may decrease the risk for local extrusion. Bone defects (diameter 5 mm; depth 15 mm) generated ex vivo in lumbar (L) spines of female Merino sheep (2–4 years) were augmented using: (i) water-based CPC with 10% PLGA fiber reinforcement (L3); (ii) Paste-CPC (L4); or (iii) clinically established polymethylmethacrylate (PMMA) bone cement (L5). Untouched (L1) and empty vertebrae (L2) served as controls. Cement performance was analyzed using micro-computed tomography, histology, and biomechanical testing. Extrusion was comparable for Paste-CPC(-PLGA) and PMMA, but significantly lower for CPC + PLGA. Compressive strength and Young’s modulus were similar for Paste-CPC and PMMA, but significantly higher compared to those for empty defects and/or CPC + PLGA. Expectedly, all experimental groups showed significantly or numerically lower compressive strength and Young’s modulus than those of untouched controls. Ready-to-use Paste-CPC demonstrates a performance similar to that of PMMA, but improved biomechanics compared to those of water-based CPC + PLGA, expanding the therapeutic arsenal for bone defects. O, significantly lower extrusion of CPC + PLGA fibers into adjacent lumbar spongiosa may help to reduce the risk of local extrusion in spinal surgery.