Sophia Sakellariou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Sophia Sakellariou has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Vassilis Charissis
Glasgow Caledonian University
7 shared publications Ben M. Ward
University of Edinburgh
2 shared publicationsDavid Chanock
Ayr Hospital
2 shared publicationsPaul Anderson
University of Glasgow/ Glasgow School of Art, Digital Design Studio
2 shared publicationsW. Chan
2 shared publicationsAbigail Ingham
University of Glasgow, Glasgow, United Kingdom
1 shared publication
Latest Publications
- 1 May 2022
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 95 (1133) , 20211241
Wireless localisation of breast lesions with MagSeed. A radiological perspective of 300 cases
Objectives: The purpose of this article is to review the technical and radiological aspects of MagSeed® localisation, to assess its accuracy based on post-localisation mammograms and excision specimen X-rays and to discuss the radiological experience of our institutions. Methods: Two-year data were collected retrospectively from three NHS boards from the West of Scotland. A total of 309 MagSeeds® were inserted under mammographic or ultrasonographic guidance in 300 women with unifocal, multifocal and/or bilateral breast lesions at the day of surgery or up to 30 days prior to it. Radiological review of post-localisation mammograms and intraoperative specimen X-rays as well as a review of the surgical outcomes were performed to assess the accuracy and efficacy of the method. Our experience relating to the technique’s strengths and downsides were also noted. Results: The MagSeeds® were inserted on average 7.2 days before surgery. The localisation technique was straight forward for the radiologists. In 99% of the cases, the MagSeed® was successfully deployed and 100% of the successfully localised lesions were excised at surgery. There was no difference in the accuracy of the localisation whether this was mammographically or ultrasonographically guided. On post-localisation mammograms, the MagSeed® was radiologically accurately positioned in 97.3% of the cases. No delayed MagSeed® migration was observed. On the specimen X-rays, the lesion was centrally positioned in 45.1%, eccentric within more than 1 mm from the margin in 35.7% and in 14.8% it was at the specimen’s margin. The re-excision rate was 18.3%. Conclusion: The MagSeed® is an accurate and reliable localisation method in breast conserving surgery with good surgical outcomes. Advances in knowledge: To our knowledge, the radiological aspects of MagSeed® localisation have not been widely described in peer-reviewed journals thus far.
- 1 May 2022
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 95 (1133) , 20211241
Wireless localisation of breast lesions with MagSeed. A radiological perspective of 300 cases
Objectives: The purpose of this article is to review the technical and radiological aspects of MagSeed® localisation, to assess its accuracy based on post-localisation mammograms and excision specimen X-rays and to discuss the radiological experience of our institutions. Methods: Two-year data were collected retrospectively from three NHS boards from the West of Scotland. A total of 309 MagSeeds® were inserted under mammographic or ultrasonographic guidance in 300 women with unifocal, multifocal and/or bilateral breast lesions at the day of surgery or up to 30 days prior to it. Radiological review of post-localisation mammograms and intraoperative specimen X-rays as well as a review of the surgical outcomes were performed to assess the accuracy and efficacy of the method. Our experience relating to the technique’s strengths and downsides were also noted. Results: The MagSeeds® were inserted on average 7.2 days before surgery. The localisation technique was straight forward for the radiologists. In 99% of the cases, the MagSeed® was successfully deployed and 100% of the successfully localised lesions were excised at surgery. There was no difference in the accuracy of the localisation whether this was mammographically or ultrasonographically guided. On post-localisation mammograms, the MagSeed® was radiologically accurately positioned in 97.3% of the cases. No delayed MagSeed® migration was observed. On the specimen X-rays, the lesion was centrally positioned in 45.1%, eccentric within more than 1 mm from the margin in 35.7% and in 14.8% it was at the specimen’s margin. The re-excision rate was 18.3%. Conclusion: The MagSeed® is an accurate and reliable localisation method in breast conserving surgery with good surgical outcomes. Advances in knowledge: To our knowledge, the radiological aspects of MagSeed® localisation have not been widely described in peer-reviewed journals thus far.
- Open Access
- 10 April 2019
- Published by MDPI AG in Multimodal Technologies and Interaction
- Vol. 3 (2) , 24
Exploring the Development Requirements for Virtual Reality Gait Analysis
The hip joint is highly prone to traumatic and degenerative pathologies resulting in irregular locomotion. Monitoring and treatment depend on high-end technology facilities requiring physician and patient co-location, thus limiting access to specialist monitoring and treatment for populations living in rural and remote locations. Telemedicine offers an alternative means of monitoring, negating the need for patient physical presence. In addition, emerging technologies, such as virtual reality (VR) and immersive technologies, offer potential future solutions through virtual presence, where the patient and health professional can meet in a virtual environment (a virtual clinic). To this end, a prototype asynchronous telemedicine VR gait analysis system was designed, aiming to transfer a full clinical facility within the patients’ local proximity. The proposed system employs cost-effective alternative motion capture combined with the system’s immersive 3D virtual gait analysis clinic. The user interface and the tools in the application offer health professionals asynchronous, objective, and subjective analyses. This paper investigates the requirements for the design of such a system and discusses preliminary comparative data of its performance evaluation against a high-fidelity gait analysis clinical application.
- 10 April 2019
- Published by MDPI AG in Multimodal Technologies and Interaction
- Vol. 3 (2) , 24
Open AccessExploring the Development Requirements for Virtual Reality Gait Analysis
The hip joint is highly prone to traumatic and degenerative pathologies resulting in irregular locomotion. Monitoring and treatment depend on high-end technology facilities requiring physician and patient co-location, thus limiting access to specialist monitoring and treatment for populations living in rural and remote locations. Telemedicine offers an alternative means of monitoring, negating the need for patient physical presence. In addition, emerging technologies, such as virtual reality (VR) and immersive technologies, offer potential future solutions through virtual presence, where the patient and health professional can meet in a virtual environment (a virtual clinic). To this end, a prototype asynchronous telemedicine VR gait analysis system was designed, aiming to transfer a full clinical facility within the patients’ local proximity. The proposed system employs cost-effective alternative motion capture combined with the system’s immersive 3D virtual gait analysis clinic. The user interface and the tools in the application offer health professionals asynchronous, objective, and subjective analyses. This paper investigates the requirements for the design of such a system and discusses preliminary comparative data of its performance evaluation against a high-fidelity gait analysis clinical application.
- 8 October 2016
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 38 (12) , 1426-1433
Rôle of contrast media viscosity in altering vessel wall shear stress and relation to the risk of contrast extravasations
Iodinated contrast media (CM) are the most commonly used injectables in radiology today. A range of different media are commercially available, combining various physical and chemical characteristics (ionic state, osmolality, viscosity) and thus exhibiting distinct in vivo behaviour and safety profiles. In this paper, numerical simulations of blood flow with contrast media were conducted to investigate the effects of contrast viscosity on generated vessel wall shear stress and vessel wall pressure to elucidate any possible relation to extravasations. Five different types of contrast for Iodine fluxes ranging at 1.5-2.2gI/s were modelled through 18G and 20G cannulae placed in an ideal vein at two different orientation angles. Results demonstrate that the least viscous contrast media generate the least maximum wall shear stress as well as the lowest total pressure for the same flow rate. This supports the empirical clinical observations and hypothesis that more viscous contrast media are responsible for a higher percentage of contrast extravasations. In addition, results support the clinical hypothesis that a catheter tip directed obliquely to the vein wall always produces the highest maximum wall shear stress and total pressure due to impingement of the contrast jet on the vessel wall.
- 8 October 2016
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 38 (12) , 1426-1433
Rôle of contrast media viscosity in altering vessel wall shear stress and relation to the risk of contrast extravasations
Iodinated contrast media (CM) are the most commonly used injectables in radiology today. A range of different media are commercially available, combining various physical and chemical characteristics (ionic state, osmolality, viscosity) and thus exhibiting distinct in vivo behaviour and safety profiles. In this paper, numerical simulations of blood flow with contrast media were conducted to investigate the effects of contrast viscosity on generated vessel wall shear stress and vessel wall pressure to elucidate any possible relation to extravasations. Five different types of contrast for Iodine fluxes ranging at 1.5-2.2gI/s were modelled through 18G and 20G cannulae placed in an ideal vein at two different orientation angles. Results demonstrate that the least viscous contrast media generate the least maximum wall shear stress as well as the lowest total pressure for the same flow rate. This supports the empirical clinical observations and hypothesis that more viscous contrast media are responsible for a higher percentage of contrast extravasations. In addition, results support the clinical hypothesis that a catheter tip directed obliquely to the vein wall always produces the highest maximum wall shear stress and total pressure due to impingement of the contrast jet on the vessel wall.
- 1 January 2013
- Published by Springer Nature
- p. 50-59
Asynchronous Telemedicine Diagnosis of Musculoskeletal Injuries through a Prototype Interface in Virtual Reality Environment
- 1 January 2013
- Published by Springer Nature
- p. 50-59
Asynchronous Telemedicine Diagnosis of Musculoskeletal Injuries through a Prototype Interface in Virtual Reality Environment
- 1 January 2011
- Published by Springer Nature
- p. 54-63
Virtual Reality as Knowledge Enhancement Tool for Musculoskeletal Pathology
- 1 January 2011
- Published by Springer Nature
- p. 54-63
Virtual Reality as Knowledge Enhancement Tool for Musculoskeletal Pathology
- 4 February 2010
- Published by SPIE-Intl Soc Optical Eng
- p. 752506-752506-10
Exploring the simulation requirements for virtual regional anesthesia training
This paper presents an investigation towards the simulation requirements for virtual regional anaesthesia training. To this end we have developed a prototype human-computer interface designed to facilitate Virtual Reality (VR) augmenting educational tactics for regional anaesthesia training. The proposed interface system, aims to compliment nerve blocking techniques methods. The system is designed to operate in real-time 3D environment presenting anatomical information and enabling the user to explore the spatial relation of different human parts without any physical constrains. Furthermore the proposed system aims to assist the trainee anaesthetists so as to build a mental, three-dimensional map of the anatomical elements and their depictive relationship to the Ultra-Sound imaging which is used for navigation of the anaesthetic needle. Opting for a sophisticated approach of interaction, the interface elements are based on simplified visual representation of real objects, and can be operated through haptic devices and surround auditory cues. This paper discusses the challenges involved in the HCI design, introduces the visual components of the interface and presents a tentative plan of future work which involves the development of realistic haptic feedback and various regional anaesthesia training scenarios.
- 4 February 2010
- Published by SPIE-Intl Soc Optical Eng
- p. 752506-752506-10
Exploring the simulation requirements for virtual regional anesthesia training
This paper presents an investigation towards the simulation requirements for virtual regional anaesthesia training. To this end we have developed a prototype human-computer interface designed to facilitate Virtual Reality (VR) augmenting educational tactics for regional anaesthesia training. The proposed interface system, aims to compliment nerve blocking techniques methods. The system is designed to operate in real-time 3D environment presenting anatomical information and enabling the user to explore the spatial relation of different human parts without any physical constrains. Furthermore the proposed system aims to assist the trainee anaesthetists so as to build a mental, three-dimensional map of the anatomical elements and their depictive relationship to the Ultra-Sound imaging which is used for navigation of the anaesthetic needle. Opting for a sophisticated approach of interaction, the interface elements are based on simplified visual representation of real objects, and can be operated through haptic devices and surround auditory cues. This paper discusses the challenges involved in the HCI design, introduces the visual components of the interface and presents a tentative plan of future work which involves the development of realistic haptic feedback and various regional anaesthesia training scenarios.
- 1 January 2009
- Published by Springer Nature
- p. 605-614
Design and Implementation of Augmented Reality Environment for Complex Anatomy Training: Inguinal Canal Case Study
- 1 January 2009
- Published by Springer Nature
- p. 605-614
Design and Implementation of Augmented Reality Environment for Complex Anatomy Training: Inguinal Canal Case Study
- 1 January 2009
- Published by Springer Nature
- p. 550-559
A Novel Approach to CT Scans’ Interpretation via Incorporation into a VR Human Model
- 1 January 2009
- Published by Springer Nature
- p. 550-559
A Novel Approach to CT Scans’ Interpretation via Incorporation into a VR Human Model