RSRicardo Mandia Stenders

Ricardo Mandia Stenders

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ricardo Mandia Stenders has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • The activation mode of a dirty-bomb can modify the health risk estimation profile

    by Rocco Pascale Neto, Vitor W. L. Silva, William H. S. Profeta, Andrew Collinson, Ricardo M. Stenders, Rodrigo C. Curzio, Hélio C. Vital, Edson R. Andrade

    This study focuses on analytical computer simulations performed to investigate a hypothetical event where the activation of a radiological dispersion device (RDD) triggers a crisis. The methodology presents steps centered on the initial evaluation phase of the event (initial 100 hours), aiming to evaluate the radiological risks regarding the development of leukemia. Local environmental changes, sex, and age were also used to assess risks. It was also estimated that the sex of potentially affected individuals was irrelevant to decisions at the early phase of the event. In contrast, age and the moment of release (day or night) were the most important variables influencing individual radiological risk. Based on the calculated results, it was possible to conclude that the proposed methodology would significantly contribute to planning the allocation of human resources, reducing future risks.


  • Open Access

    Urban Operation Threat Assessment after a Multistage Radiological Dispersive Device Attack

    by Isabela S. Alves, Rodrigo C. Curzio, Carlos Eduardo S. Bonfim, Ricardo M. Stenders, Edson R. Andrade

    The urban environment may be a relevant setting for special military operations. Due to the options offered by urban infrastructure, this environment can be an essential catalyst for the proliferation of local asymmetric actions. These actions are triggered by extremist groups offering resistance to regular troops. Improvised weapons such as radiological dispersive devices (RDD) can be used to provoke even more threatening situations by increasing the risks of operations. This study is directed, via computer simulation using the Hot Spot Health Physics code, to a hypothetical context where a multistage RDD (RDD-M) is triggered in two non-simultaneous phases. This non-linear triggering causes overlapping contamination and impacts the coping strategy and the projections of variations in the size of the potentially affected population. In this study, the primary consideration is the contamination carried out at such a level that the association between human exposure and deterministic effects is feasible. The exposure to high doses of radiation at short distances about the triggering location of the device. The simulated data show that the threats are leveraged, and the environmental variables have a high value when assessing the criticality of the situation and establishing effective countermeasures.

  • Open Access

    Human and Environmental Bias Affecting Risk Perception in Military Radiological and Nuclear Operations

    by Edson Ramos Andrade, Isabela Santos Alves, Ricardo Mandia Stenders, André Luiz Queiroga Reis

    The urban military operating environment may offer favorable conditions for combat involving asymmetric actions or 4th generation warfare which includes the chemical, biological, radiological, or nuclear (CBRN) environment. The CBRN environment is characterized by threats and hazards capable of producing negative impacts to the operations. The detriment may be produced by intentional release of hazardous materials into the operational environment. This study deals with an environment deliberately contaminated by radioactive materials because of the activation of a radiological dispersive device (RDD). A computer simulation of the radioactive scenario was performed in order to produce useful information which in turn can be used to support decision-making. The main goal was to assess the risk of developing radio-induced solid cancer by studying the articulation between local environmental variables and a cognitive bias, the Dunning-Kruger effect. The findings highlight intuitive correlations between local atmospheric stability and cognitive bias affecting the threat level (radiation dose), the responsiveness and the perceived risk. The findings also allow us to infer that, especially in the military-operational context, the methodology proposed for the assessment of environment-human interactions may be decisive for correctly direct available resources, both human and material, reducing operational risk.


  • Open Access

    Radiological Consequences Modelling for a Land Based Operations Environment

    by Rodrigo Werner Silva, André Luiz Queiroga Reis, Ricardo M. Stenders, Edson Ramos Andrade

    Radiological Dispersive Devices (RDD) are often portrayed as weapons used by radical (asymmetric) forces, however they can also be used in a regular war. In this study, a hypothetical scenario where an asymmetric force contaminates the battlefield, by detonating an RDD prior to the soldier’s arrival without being detected, is simulated. The software HotSpot was used due to its speed and conservative results which can help inform the decisions made by the commanding officers. HotSpot performs a Gaussian simulation of the radioactive dispersion in the environment. The plumes that arise from the explosion are considered to be affected by the atmospheric conditions. In this study, those conditions are represented by the Pasquill-Gifford stability classes. The results of the simulation show that remaining stationary, if the contaminated area size is not affected by the PG class variation, may increase the radiological risk. It is better to move the soldiers around in order to avoid additional exposure, however that may also be a challenge for various reasons including changes in the shape of the contaminated area. Nevertheless, the variations in local PG classes gain importance as the distance from the release point increases.