HKHyeongbeom Kim

Hyeongbeom Kim

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Hyeongbeom Kim has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Quantitative measurement of optical properties and Hb concentration in a rodent model of inflammatory Meibomian gland dysfunction using spatial frequency domain imaging

    by Hyeongbeom Kim, Kyong Jin Cho, Anthony J. Durkin, Bruce J. Tromberg, Ilyong Park

    Herein, to investigate a new diagnostic method for Meibomian gland dysfunction (MGD) induced by eyelid inflammation, optical properties and deoxy-hemoglobin (Hb) concentrations in rodent eyelid tissues, including Meibomian glands(MGs), were measured using spatial frequency domain imaging (SFDI). Complete Freund’s adjuvant solutions were injected into the eyelid margins of Sprague–Dawley rats to induce MGD. After three weeks, the optical properties and Hb of the MG and non-MG regions of the eyelids were measured ex–vivo using an SFDI system. The comparison of Hb showed that the MGD group exhibited significantly higher values than those of the control group in both regions. The optical properties at 730 and 850 nm for the MG regions in the MGD group were significantly different from those in the control group. In addition, the 630 nm absorption coefficients of both regions were significantly higher in the MGD group than in the control group. Thus, the SFDI technique can detect the increased Hb concentration and changes in the optical properties of the eyelids due to inflammatory MGD in a noncontact manner and has the potential to be used as a novel quantitative diagnostic method for the occurrence of MGD.


  • The application of SFDI and LSI system to evaluate the blood perfusion in skin flap mouse model

    by Lele Lyu, Hyeongbeom Kim, Jun-Sang Bae, Cheng Hua, Jie Hye Kim, Eun-Hee Kim, Ji-Hun Mo, Ilyong Park

    The aim of this study is to evaluate whether the blood perfusion to tissues for detecting ischemic necrosis can be quantitatively monitored by spatial frequency domain imaging (SFDI) and laser speckle imaging (LSI) in a skin flap mouse model. Skin flaps were made on Institute of Cancer Research (ICR) mice. Using SFDI and LSI, the following parameters were estimated: oxyhemoglobin (HbO2), deoxyhemoglobin (Hb), total hemoglobin (THb), tissue oxygen saturation (StO2), and speckle flow index (SFI). Histologically, epithelium thickness, collagen deposition, and blood vessel count of skin flap tissues were analyzed. Then, the correlation of SFDI and histological results was assessed by application of Spearman rank correlation method. As the result, the number of blood vessels and the percentage of collagen areas showed significant difference between the necrotic tissue group and the non-necrotic one. Especially, the necrotic tissue had a complete epithelial loss and loses its normal structure. We identified that SFDI/LSI parameters were significantly different between non-necrotic and necrotic tissue groups. Especially, all SFDI and LSI parameters measured on the 1st day after surgery showed significant difference between necrotic tissue and non-necrotic tissue. In addition, the number of blood vessel and percentage of collagen area were positively correlated with HbO2 and StO2 among SFDI/LSI parameters. Meanwhile, the number of blood vessel and percentage of collagen area showed the negative correlation with Hb. By applying SFDI and LSI simultaneously to the skin flap, we could quantitatively monitor the blood perfusion and the tissue condition which can help us to detect ischemic necrosis objectively in early stage.


  • Multimodal sensor-based weight drop spinal cord impact system for large animals

    by Hyeongbeom Kim, Jong-Wan Kim, Jung Keun Hyun, Ilyong Park