Fareeha Hameed
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Fareeha Hameed has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
M. Zawisky
4 shared publicationsA. Rohatsch
Vienna University of Technology, Institute for Engineering Geology, Vienna, Austria
2 shared publicationsE. Dyrnjaja
Vienna University of Technology, Atomic Institute, Vienna, Austria
2 shared publicationsJ. Springer
Vienna University of Technology, Atomic Institute, Vienna, Austria
2 shared publicationsAbdalla Ahmad
1 shared publicationAbdel R. Hasoneh
1 shared publication
Latest Publications
- Open Access
- 6 October 2026
- Published by International Union of Crystallography (IUCr) in IUCrJ
- Vol. 13 (6) , 705-716
Lighting up materials with X-rays: advanced X-ray excited optical luminescence probe at the BM08-XAFS/XRF beamline, SESAME
A highly sensitive X-ray excited optical luminescence (XEOL) probe has been developed and commissioned at the end station of the BM08-XAFS/XRF beamline, SESAME, capable of measuring emission spectra in a broad wavelength range from 200 to 950 nm with optical resolution of ∼1.60 nm, under both X-ray beam and laser (UV–Vis/NIR) excitation sources. This experimental setup is equipped with a high-sensitivity spectrometer coupled to a customized sample environment via an optical fiber of 0.22 numerical aperture. The in-house-developed sample environment contains multiple entrance windows for the simultaneous X-ray beam and laser irradiations, and an exit window to a Basler camera coupled via a focusing lens. The real-time monitoring of the emission's spatial distribution in material under element-specific X-ray excitation and laser irradiation through an integrated XEOL camera, and acquisition of the emission spectra and two-dimensional hyperspectral mapping using an integrated spectrometer, provides a powerful probe for the development of homogeneous ionizing-radiation scintillators. Such materials are critically important for advanced imaging technologies, including X-ray computed tomography. XEOL studies and hyperspectral mapping were performed on selected representative systems/X-ray scintillators including Gd 3 Ga 5 O 12 :Eu 3+ (GGG:Eu), Gd 2 O 2 S:Tb 3+ , Gd 2 O 3 , semiconductor quantum dots, rare-earth ion (RE 3+ ) complexes and organic polymer/RE 3+ hybrid films to demonstrate the performance of the setup across a broad spectral range from the UV–Vis to NIR regions. The combination of XEOL with X-ray absorption spectroscopy at BM08 enables users to probe optical emission pathways in material and correlate them directly with the electronic structure and chemical environment of the photoemitting centers in the material.
- 6 October 2026
- Published by International Union of Crystallography (IUCr) in IUCrJ
- Vol. 13 (6) , 705-716
Open AccessLighting up materials with X-rays: advanced X-ray excited optical luminescence probe at the BM08-XAFS/XRF beamline, SESAME
A highly sensitive X-ray excited optical luminescence (XEOL) probe has been developed and commissioned at the end station of the BM08-XAFS/XRF beamline, SESAME, capable of measuring emission spectra in a broad wavelength range from 200 to 950 nm with optical resolution of ∼1.60 nm, under both X-ray beam and laser (UV–Vis/NIR) excitation sources. This experimental setup is equipped with a high-sensitivity spectrometer coupled to a customized sample environment via an optical fiber of 0.22 numerical aperture. The in-house-developed sample environment contains multiple entrance windows for the simultaneous X-ray beam and laser irradiations, and an exit window to a Basler camera coupled via a focusing lens. The real-time monitoring of the emission's spatial distribution in material under element-specific X-ray excitation and laser irradiation through an integrated XEOL camera, and acquisition of the emission spectra and two-dimensional hyperspectral mapping using an integrated spectrometer, provides a powerful probe for the development of homogeneous ionizing-radiation scintillators. Such materials are critically important for advanced imaging technologies, including X-ray computed tomography. XEOL studies and hyperspectral mapping were performed on selected representative systems/X-ray scintillators including Gd 3 Ga 5 O 12 :Eu 3+ (GGG:Eu), Gd 2 O 2 S:Tb 3+ , Gd 2 O 3 , semiconductor quantum dots, rare-earth ion (RE 3+ ) complexes and organic polymer/RE 3+ hybrid films to demonstrate the performance of the setup across a broad spectral range from the UV–Vis to NIR regions. The combination of XEOL with X-ray absorption spectroscopy at BM08 enables users to probe optical emission pathways in material and correlate them directly with the electronic structure and chemical environment of the photoemitting centers in the material.
- Open Access
- 21 February 2025
- Published by Elsevier in Tomography of Materials and Structures
- Vol. 7
Synchrotron computed tomography of 5000 years old faience beads from Southeastern Anatolia (Türkiye)
- 21 February 2025
- Published by Elsevier in Tomography of Materials and Structures
- Vol. 7
Open AccessSynchrotron computed tomography of 5000 years old faience beads from Southeastern Anatolia (Türkiye)
- Open Access
- 15 November 2021
- Published by MDPI AG in Journal of Imaging
- Vol. 7 (11) , 240
Analysis, Design and Realization of a Furnace for In Situ Wettability Experiments at High Temperatures under X-ray Microtomography
In this study, we analyzed the problem of a compact furnace, to be used for in situ experiments in a cone-beam X-ray microtomography commercial system. The design process was accomplished and outlined through its main steps, until the realization of a prototype. The furnace was conceived to carry out wettability experiments at temperatures up to 700 °C and under inert atmosphere on sessile droplets of a molten metal alloy, with a few millimeters diameter, posed on a thin ceramic substrate. X-ray imaging of the molten droplet is expected to permit an accurate three-dimensional reconstruction of the droplet profile and a robust estimation of the related quantities (such as the contact angle and the surface tension) utilized for the assessment of metal-ceramic joints by brazing. The challenges faced during this project, mostly related to the constraints of the setup, and the novel solutions implemented were discussed also with the support of analytical and numerical tools, in terms of interaction of X-rays with matter, geometry and working principle, heat transfer and insulation, material selection.
- 15 November 2021
- Published by MDPI AG in Journal of Imaging
- Vol. 7 (11) , 240
Open AccessAnalysis, Design and Realization of a Furnace for In Situ Wettability Experiments at High Temperatures under X-ray Microtomography
In this study, we analyzed the problem of a compact furnace, to be used for in situ experiments in a cone-beam X-ray microtomography commercial system. The design process was accomplished and outlined through its main steps, until the realization of a prototype. The furnace was conceived to carry out wettability experiments at temperatures up to 700 °C and under inert atmosphere on sessile droplets of a molten metal alloy, with a few millimeters diameter, posed on a thin ceramic substrate. X-ray imaging of the molten droplet is expected to permit an accurate three-dimensional reconstruction of the droplet profile and a robust estimation of the related quantities (such as the contact angle and the surface tension) utilized for the assessment of metal-ceramic joints by brazing. The challenges faced during this project, mostly related to the constraints of the setup, and the novel solutions implemented were discussed also with the support of analytical and numerical tools, in terms of interaction of X-rays with matter, geometry and working principle, heat transfer and insulation, material selection.
- Open Access
- 19 December 2019
- Published by Frontiers Media SA in Frontiers in Earth Science
- Vol. 7
Implementation of Dynamic Neutron Radiography and Integrated X-Ray and Neutron Tomography in Porous Carbonate Reservoir Rocks
The textural and geometrical properties of the pore networks (i.e. such as pore size distribution, pore shape, connectivity and tortuosity) provides a primary control on the fluid storage and migration of geofluids within porous carbonate reservoirs. These properties are highly variable because of primary depositional conditions, diagenetic processes and deformation. This issue represents an important challenge for the characterization and exploitation plan in this type of reservoirs. In this study, the complementary properties of neutrons and X-ray experiments are carried out to better understand the effects of pore network properties on the hydraulic behavior of porous carbonates. Neutrons have unique properties and are particularly suitable for this study due to the sensitivity of neutrons to hydrogen-based fluids. The used methodology combines dynamic neutron radiography (NR), integrated X-ray and neutron tomography (XCT, NCT), and computational fluid dynamics simulations (lattice-Boltzmann method) of porous carbonate reservoir analogues from central and southern Italy. Dynamic 2D NR images provide information regarding the fluid transport and the wetting front dynamics related to the effect of heterogeneities (e.g. fractures and deformation bands) at the microscale. The combination of NCT (dry and wet samples) and XCT (dry), generates more information regarding the effective pore space contribution to fluid flow. The fluid flow simulations generate information about the connected pore network and the permeability evaluated rock sample at saturated condition.
- 19 December 2019
- Published by Frontiers Media SA in Frontiers in Earth Science
- Vol. 7
Open AccessImplementation of Dynamic Neutron Radiography and Integrated X-Ray and Neutron Tomography in Porous Carbonate Reservoir Rocks
The textural and geometrical properties of the pore networks (i.e. such as pore size distribution, pore shape, connectivity and tortuosity) provides a primary control on the fluid storage and migration of geofluids within porous carbonate reservoirs. These properties are highly variable because of primary depositional conditions, diagenetic processes and deformation. This issue represents an important challenge for the characterization and exploitation plan in this type of reservoirs. In this study, the complementary properties of neutrons and X-ray experiments are carried out to better understand the effects of pore network properties on the hydraulic behavior of porous carbonates. Neutrons have unique properties and are particularly suitable for this study due to the sensitivity of neutrons to hydrogen-based fluids. The used methodology combines dynamic neutron radiography (NR), integrated X-ray and neutron tomography (XCT, NCT), and computational fluid dynamics simulations (lattice-Boltzmann method) of porous carbonate reservoir analogues from central and southern Italy. Dynamic 2D NR images provide information regarding the fluid transport and the wetting front dynamics related to the effect of heterogeneities (e.g. fractures and deformation bands) at the microscale. The combination of NCT (dry and wet samples) and XCT (dry), generates more information regarding the effective pore space contribution to fluid flow. The fluid flow simulations generate information about the connected pore network and the permeability evaluated rock sample at saturated condition.
- 1 September 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 108-113
Digital imaging in cultural heritage neutron tomography imaging of restored original samples from Austrian cultural heritage
The protection and conservation of our cultural heritage which is made of natural stone is of cultural and economic value. The interaction of natural stone-made surfaces with different chemical and physical, climatic controlled, weathering processes, leads to a rapidly increasing deterioration of these monuments. Several different methods are employed in order to conserve and restore these important structures. An effective technique of conservation and restoration is the use of chemical consolidants. One of the main tasks of stone consolidants is a deep penetration into the weakened fabric and the reconstruction of the grain binding strength. The three-dimensional distribution of the consolidants in weathered rock is important for the evaluation of this conservation procedure. Neutron Imaging due to the specific sensitivity of neutrons for hydrogen could be a very useful tool for non-destructive investigation of the chemical inside the restored sample. The method of neutron tomography gives a three dimensional (3D) mapping of the conservation agent in the sample. This paper presents the application of the method of neutron tomography for assessing the consolidation of valuable original samples from historical buildings and monuments in Austria.
- 1 September 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 108-113
Digital imaging in cultural heritage neutron tomography imaging of restored original samples from Austrian cultural heritage
The protection and conservation of our cultural heritage which is made of natural stone is of cultural and economic value. The interaction of natural stone-made surfaces with different chemical and physical, climatic controlled, weathering processes, leads to a rapidly increasing deterioration of these monuments. Several different methods are employed in order to conserve and restore these important structures. An effective technique of conservation and restoration is the use of chemical consolidants. One of the main tasks of stone consolidants is a deep penetration into the weakened fabric and the reconstruction of the grain binding strength. The three-dimensional distribution of the consolidants in weathered rock is important for the evaluation of this conservation procedure. Neutron Imaging due to the specific sensitivity of neutrons for hydrogen could be a very useful tool for non-destructive investigation of the chemical inside the restored sample. The method of neutron tomography gives a three dimensional (3D) mapping of the conservation agent in the sample. This paper presents the application of the method of neutron tomography for assessing the consolidation of valuable original samples from historical buildings and monuments in Austria.
- 1 June 2009
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 605 (1-2) , 150-153
Investigations of stone consolidants by neutron imaging
- 1 June 2009
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 605 (1-2) , 150-153
Investigations of stone consolidants by neutron imaging
- 28 August 2008
- Published by SPIE-Intl Soc Optical Eng
- p. 70800H-70800H-10
Neutron imaging of radioactive sources
Isotopic neutron sources have been available for more than six decades. At the Atomic Institute in Vienna, operating a 250 kW TRIGA reactor, different neutron sources are in use for instrument calibration and fast neutron applications but we have only little information about their construction and densities. The knowledge of source design is essential for a complete MCNP5 modeling of the experiments. Neutron radiography (NR) and neutron tomography (NT) are the best choices for the non-destructive inspection of the source geometry and homogeneity. From the transmission analysis we gain information about the shielding components and the densities of the radio-isotopes in the cores. Three neutron sources, based on (alpha, n) reaction, have been investigated, two 239PuBe sources and one 241AmBe source. In the NR images the internal structure was clearly revealed using high-resolving scintillation and imaging plate detectors. In one source tablet a crack was detected which causes asymmetric neutron emission. The tomography inspection of strong absorbing materials is more challenging due to the low beam intensity of 1.3x105 n/cm2s at our NT instrument, and due to the beam hardening effect which requires an extension of reconstruction software. The tomographic inspection of a PuBe neutron source and appropriate measures for background and beam hardening correction are presented.
- 28 August 2008
- Published by SPIE-Intl Soc Optical Eng
- p. 70800H-70800H-10
Neutron imaging of radioactive sources
Isotopic neutron sources have been available for more than six decades. At the Atomic Institute in Vienna, operating a 250 kW TRIGA reactor, different neutron sources are in use for instrument calibration and fast neutron applications but we have only little information about their construction and densities. The knowledge of source design is essential for a complete MCNP5 modeling of the experiments. Neutron radiography (NR) and neutron tomography (NT) are the best choices for the non-destructive inspection of the source geometry and homogeneity. From the transmission analysis we gain information about the shielding components and the densities of the radio-isotopes in the cores. Three neutron sources, based on (alpha, n) reaction, have been investigated, two 239PuBe sources and one 241AmBe source. In the NR images the internal structure was clearly revealed using high-resolving scintillation and imaging plate detectors. In one source tablet a crack was detected which causes asymmetric neutron emission. The tomography inspection of strong absorbing materials is more challenging due to the low beam intensity of 1.3x105 n/cm2s at our NT instrument, and due to the beam hardening effect which requires an extension of reconstruction software. The tomographic inspection of a PuBe neutron source and appropriate measures for background and beam hardening correction are presented.
- 1 March 2008
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 587 (2-3) , 342-349
Digitized neutron imaging with high spatial resolution at a low power research reactor: I. Analysis of detector performance
- 1 March 2008
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 587 (2-3) , 342-349
Digitized neutron imaging with high spatial resolution at a low power research reactor: I. Analysis of detector performance